TAO-1.1 07-16-14 TAO TAO – Temperature Ambient Optimizer Floor Mounted Chilled Beam with Perimeter Heating Coil PATENT PENDING PATENT PENDING Basic Unit Configuration Check if provided Length □ 5 ft □ 6 ft Air Inlet Option □ Standard 6" Air Inlet □ Quick Connect 8" Oval Trunk Duct Vertical Safety Pan □ Removable Safety Pan □ No Safety Pan Piping Connection □ Smooth □ Male Pipe Thread General Description Floor Mounted, under the sill or fully exposed active chilled beam targets educational and health care facilities and hallways. Perfect for climate zones with heat loads greater than 250 Btuh per foot. Designed to meet the highest ventilation effectiveness required in schools and health care facilities while macimizing the hydronic system to handle the sensible load. Pencil proof grille Maximizes the displacement ventilation benefits and enhances the removal of space respiratory contaminants. Circular perforated front face for the return air. Ultra quiet operation. Dedicated heating coil to neutralize the thermal load of the window or perimeter wall. 2x2 pipe vertical mounted coil with removable condensate tray for cooling during summer and to provide supplemental heating for winter. Coils are factory leak tested at 300psi. Manual air vent provided as standard. Optional coil drain. Heavy gauge painted cabinet. ½” coil connections as standard. Pressure port for air-side balancing and flow verification. Available in 5 and 6 ft length to match different classroom spaces and loads. Optional integral primary air parallel duct connection to minimize air pressure drop, noise, and ease of installation. TAO-2.1 DIMENSIONS 07-16-14 TAO UNIT DIMENSIONS 6" ROUND INLET FOR STAND-ALONE APPLICATIONS Inlet Size Unit 6" Round 8" Oval 5 ft 6 ft Dimensions (Inches) A B C 60 30 43 3/4 72 30 55 3/4 8" OVAL INLET FOR MULTI-UNIT APPLICATIONS ALL DIMENSIONS ARE IN INCHES TAO-3.1 DIMENSIONS TAO UNIT DIMENSIONS Wall Mounting Inlet Size 6" Round 8" Oval Unit 5 ft 6 ft D 49 1/8 61 1/8 Duct Connections (Stand-alone configuration shown) ALL DIMENSIONS ARE IN INCHES 07-16-14 TAO-4.1 INSTALLATION 07-16-14 TAO Multiple Units Connected in Parallel Right hand unit with oval air inlet connection and outlet side open Right hand unit with oval air inlet connection and outlet side open Right hand unit with oval air inlet connection and outlet side closed Floor mounting bracket by others Field installed 8" oval duct coupling (optional) Units viewed from the back showing interconnection between units. Filler Panel & Bookshelf Details Filler Panel (optional) Bookshelf Filler Panel (Optional)
© Copyright 2025 Paperzz