EXD-2N, EXD-3N Express Deck Lavatory System – EXD-Series ® • ADA and TAS Compliant • Serves One to Three Users at a Time • Standard Lavatory Spacing on 30" Centers • Continuous Bowl is Constructed of Terreon® or Terreon®RE Solid Surface Material • Select a Bradley Faucet or faucet by others • Available in a variety of colors EXD-2N/WH (Wall-Hung Frame) shown with optional soap dispensers and optional Aerada™ 900 Series Futura Faucets Specifications Accommodates one to three users. Units handle washroom traffic quickly and economically, while providing each user with personal space. The Express® Deck System is designed with standard lavatory spacing positioned on 30" centers. Construction Bowl Constructed of Terreon, a densified solid surface material composed of polyester resin, or TerreonRE, a densified solid surface material composed of a bio-based resin and preconsumer recycled granules. Terreon and TerreonRE are resistant to chemicals, stains, burns and impact. Surface damage can be easily repaired with everyday cleansers or fine grit abrasives. Terreon and TerreonRE are certified by Home Innovation Lab to meet CSA B45.5/IAPMO Z124. Terreon and TerreonRE are GREENGUARD® certified as low-emitting materials. Access Panel Panel is composed of high impact polymer. Highly resistant to impact, abrasion and corrosion. The panel will not chip, peel or flake. Support Frame Bowl assembly and access panel are secured to a heavy gauge stainless steel support frame mounted to wall. Vandal Resistance Water supplies, valving, waste assembly and other optional items are concealed within the pedestal/frame. Code Compliance and Certifications EXD-3N/STD (Standard Frame) shown with optional soap dispensers and optional Aerada 900 Series Futura Faucets Standard Frame The standard frame on the Express® EXD-Series includes a scuff base and is designed to comply with all ADA guidelines on reaches, clearances and operation for adult users. ANSI Standards Terreon and TerreonRE are Home Innovation Lab certified to meet CSA/B45.5/IAPMO Z124. Wall-Hung Frame The wall-hung frame on the Express® EXD-Series (less scuff base above) is designed cUPC Approval to mount at different heights (adult and children) to comply with guidelines on reaches, Express Lavatory Systems are Uniform Plumbing Code (UPC), International Plumbing clearances and operation for various codes including, ADA Accessibility Guidelines Code (IPC) and National Plumbing Code of Canada (NPC) approved through the for Buildings and Facilities (ADAAG) and TAS (Texas Accessibility Standards). Always International Association of Plumbing and Mechanical Officials (IAPMO). Manufactured check your local and state codes. in compliance with IGC 156, CSA B45 Series (R08) & ASME A112.18.1/CSA B125.1. Standard Equipment This plumbing fixture is designed for hand washing only. It is not Intended to dispense water for human consumption through drinking or for preparation of food or beverages. Standard product selections contained within this document are third party CERTIFIED to NSF/ANSI 372 meeting the Lead-Free content requirement. Any product configured with custom options will be COMPLIANT with NSF/ ANSI 372 meeting the Lead-Free content requirement. Bowl with two or three lavatories, pedestal, stainless steel mounting frame (as described above), and the following fittings: P-trap; tailpiece. Certified to NSF/ANSI 372 F or more information on faucets, valves, transformers, cabinets, and the sensor-operated soap dispenser, please visit bradleycorp.com. Verify all rough-in dimensions prior to installation. Consult local and national codes. Conformity and compliance to local and national codes is the responsibility of the installer. Page 1 of 6 3/2/2017 This information is subject to change without notice. Bradley_Sink_Express_EXD-2N_3N © 2017 Bradley P.O. Box 309, Menomonee Falls, WI 53052-0309 800 BRADLEY (800 272 3539) +1 262 251 6000 bradleycorp.com EXD-2N, EXD-3N Express Deck Lavatory System – EXD-Series ® Dimensions (mm) 50" (1270) 3½" (89) EXD-2N – TOP VIEW 3" (76) 21" (533) 13¾" (349) 8" R (203) 10" R (254) EXD-3N – TOP VIEW 15" (381) 15" (381) 80" (2032) 3½" (89) 21" (533) 3" (76) 13¾" (349) 8" R (203) 10" R (254) 30" (762) EXD-2N – FRONT VIEW – STANDARD FRAME 30" (762) EXD-3N – FRONT VIEW – STANDARD FRAME 8" (203) 7" (178) 51¼" (1302) 21¼" (540) 30" (762) 36" (914) 64" (1626) EXD-2N – FRONT VIEW – WALL-HUNG FRAME EXD-3N – FRONT VIEW – WALL-HUNG FRAME 8" (203) 7" (203) 30" (762) 36" (914) Verify all rough-in dimensions prior to installation. Consult local and national codes. Conformity and compliance to local and national codes is the responsibility of the installer. Page 2 of 6 3/2/2017 This information is subject to change without notice. Bradley_Sink_Express_EXD-2N_3N 58" (1473) 58" (1473) 64" (1626) © 2017 Bradley P.O. Box 309, Menomonee Falls, WI 53052-0309 800 BRADLEY (800 272 3539) +1 262 251 6000 bradleycorp.com EXD-2N, EXD-3N Express Deck Lavatory System – EXD-Series ® Dimensions – Side View Standard Height (mm) 211⁄8" (537) Wall-Hung Mounted at Standard Height 11½" (292) 211⁄8" (537) 11½" (292) 34" (864) 34" (864) 30" (762) 85⁄8" (219) 30" (762) 3" (76) 13¼" (311) 13¼" (311) Scuff Base on Standard Height Only Wall-Hung Mounted at Juvenile Height: Ages 6 through 12 85⁄8" (219) 211⁄8" (537) 11½" (292) 31" (787) 85⁄8" (219) 27" (686) 10¼" (260) Wall-Hung Mounted at TAS Height: Grades 6 through 8 or 9 211⁄8" (537) 11½" (292) 32" (813) Wall-Hung Mounted at TAS Height: Grades Pre-K through 5 or 6 211⁄8" (537) 11½" (292) 30" (762) 85⁄8" (219) 28" (711) 11¼" (286) Verify all rough-in dimensions prior to installation. Consult local and national codes. Conformity and compliance to local and national codes is the responsibility of the installer. Page 3 of 6 3/2/2017 This information is subject to change without notice. Bradley_Sink_Express_EXD-2N_3N 85⁄8" (219) 26" (660) 9¼" (235) © 2017 Bradley P.O. Box 309, Menomonee Falls, WI 53052-0309 800 BRADLEY (800 272 3539) +1 262 251 6000 bradleycorp.com EXD-2N, EXD-3N Express Deck Lavatory System – EXD-Series ® Model EXD-2N – Mounting for Standard and Wall-Hung Heights are Shown (mm) 23½" (597) 23½" (597) 13¼" (337) 93⁄8" (264) 93⁄8" (264) A A 3" (76) B D 4" (102) 34" (864) Rim Height See Chart 1 D E 4" (102) F B Cold or Tempered Supply 32" (813) Hot Supply B 28¾" (730) B 25¾" (654) 20" (508) 15" (381) C 3½" (89) CHART 1 CHART 2 RIM HEIGHT VERTICAL HEIGHT ADJUSTMENTS A – H FIXTURE STYLE 34" None Standard Height 34" None Wall-Hung B 32" Subtract 2" TAS, Grades 6 through 8 or 9 C 31" Subtract 3" Juvenile Height 30" Subtract 4" TAS, Pre-K through 5 or 6 Verify all rough-in dimensions prior to installation. Consult local and national codes. Conformity and compliance to local and national codes is the responsibility of the installer. Page 4 of 6 3/2/2017 This information is subject to change without notice. Bradley_Sink_Express_EXD-2N_3N CODE DESCRIPTION QTY. ⁄8" Bowl Wall Anchors with a Min. Pull-Out Force of 1000 lbs. 2 ⁄8" Main Frame Wall Anchors with a Minimum Pull-Out Force of 1000 lbs. 4 ⁄8" Base Frame Wall Anchors with a Min. Pull-Out Force of 1000 lbs. Standard Frame Option Only. 2 D ½" Nominal Copper Tubing for Hot/Cold Supplies, Stub-Out 2" from Wall 2 E 1½" NPT Drain, Stub-Out 2" from Wall 1 F 110V GFCI Protected Elec. Outlet 1 A 3 3 3 © 2017 Bradley P.O. Box 309, Menomonee Falls, WI 53052-0309 800 BRADLEY (800 272 3539) +1 262 251 6000 bradleycorp.com EXD-2N, EXD-3N Express Deck Lavatory System – EXD-Series ® Model EXD-3N – Mounting for Standard and Wall-Hung Heights are Shown (mm) 38½" (978) 38½" (978) 243⁄8" (619) 243⁄8" (619) 13" (330) 8" (203) 10" (254) 4" (102) A 2¾" (70) B B F1 32" (813) 28¾" (730) D E D F Tempered Supply B A B B B 24" (610) 34" (864) Rim Height See Chart 1 55⁄8" (143) 15" (381) C C 3½" (89) CHART 2 CHART 1 RIM HEIGHT VERTICAL HEIGHT ADJUSTMENTS A – H FIXTURE STYLE 34" None Standard Height 34" None Wall-Hung B 32" Subtract 2" TAS, Grades 6 through 8 or 9 C 31" Subtract 3" Juvenile Height 30" Subtract 4" TAS, Pre-K through 5 or 6 Verify all rough-in dimensions prior to installation. Consult local and national codes. Conformity and compliance to local and national codes is the responsibility of the installer. Page 5 of 6 3/2/2017 This information is subject to change without notice. Bradley_Sink_Express_EXD-2N_3N CODE DESCRIPTION QTY. ⁄8" Bowl Wall Anchors with a Min. Pull-Out Force of 1000 lbs. 2 ⁄8" Main Frame Wall Anchors with a Minimum Pull-Out Force of 1000 lbs. 6 ⁄8" Base Frame Wall Anchors with a Min. Pull-Out Force of 1000 lbs. Standard Frame Option Only. 2 D ½" Nominal Copper Tubing for Hot/Cold Supplies, Stub-Out 2" from Wall 2 E 1½" NPT Drain, Stub-Out 2" from Wall 1 F 110V GFCI Protected Elec. Outlet 1 F1 110V GFCI Protected Elec. Outlet – OPTIONAL 1 A 3 3 3 © 2017 Bradley P.O. Box 309, Menomonee Falls, WI 53052-0309 800 BRADLEY (800 272 3539) +1 262 251 6000 bradleycorp.com EXD-2N, EXD-3N Express Deck Lavatory System – EXD-Series ® Models (Must select one) Model ¨EXD-2N ¨EXD-3N Description Express Deck Lavatory System, 2-Station Express Deck Lavatory System, 3-Station Standard Selections (Must select one from each category) Faucet Drilling* (select one) ¨4" SET4" Centerset (1-1/4" Drilling Only) ¨8" SET8" Centerset (1-1/4" Drilling Only) Pedestal (select one) ¨STD Standard Frame - 34" (With Scuff Base) Soap Dispenser (select one) ¨6324 16oz. Plastic Globe, 4" Spout ¨6324-6832oz. Plastic Globe, 4" Spout ¨6315 Sensor-Operated Soap Dispenser ¨SHANK Centershank (1-1/4" Drilling Only) ¨WH Wall-Hung Frame ¨SDOSoap Drilling Only ¨NSDNo Soap Dispenser For 6315 Dispenser (must order as separate line items) ¨P19-232B ¨P19-232A ¨P19-231F 1000-Shot or 27 oz. Lotion Soap with Moisturizer (4 Bottles per Case) 2000-Shot or 54 oz. Lotion Soap with Moisturizer (4 Bottles per Case) AC Adapter - 6315 Soap Dispenser Water Supply (select one) ¨TMA ¨TL ¨NONE Navigator® Thermostatic Mixing Assembly (Hot and Cold Supplies - supply hoses and shut-offs included) Single Tempered Line Assembly (supply hoses and shut-off included) No Valve Option Selected Color of Terreon® Bowl (select one) Standard Colors E-GRAY Empire Gray DS-WHTDesigner White COBBLE Cobblestone BONE Mesa Bone CHAR Charcoal Gray WHT-SAND White Sand PEP-WHT Peppered White GRAPH Graphite LONDON London Gray SAND Sandtrap LANNONLannonstone O-TAUPE Organic Taupe Designer Colors (available at an additional charge; non-cancelable, non-returnable) RIVER Riverstone ARC-CHIPArctic Chip COFFEE Coffee Bean TerreonRE Colors (available at an additional charge; non-cancelable, non-returnable) BIRCH-BARK Birch Bark MOONDUST Moon Dust DUSK Dusk OAT Oat Color of Access Panel (select one) COAL Coal Optional Selections P-Trap: ¨ S-CHROMESingle Chrome-Plated P-Trap Verify all rough-in dimensions prior to installation. Consult local and national codes. Conformity and compliance to local and national codes is the responsibility of the installer. Page 6 of 6 3/2/2017 This information is subject to change without notice. Bradley_Sink_Express_EXD-2N_3N © 2017 Bradley P.O. Box 309, Menomonee Falls, WI 53052-0309 800 BRADLEY (800 272 3539) +1 262 251 6000 bradleycorp.com
© Copyright 2025 Paperzz