MCMK 4-core Power cables 1 kV power cable with PVC insulated copper conductors Application Construction For fixed installation indoors, outdoors and underground as well as in building structures, e.g. directly in concrete. Not for installations subject to severe electrical interference (see MCCMK). CE, FI, S, EEI Conductor . . . . . .annealed copper; 1,5–6 mm2 – solid round; 10 and 16 mm2 – stranded, round (RM) Insulation . . . . . . .lead-free PVC Laying up . . . . . . .three phase conductors stranded together Filling . . . . . . . . . .filling compound PE conductor . . . .concentric layer of copper wires and an open helix of parallel copper wires Sheath . . . . . . . . .black, lead-free PVC compound Rated voltage Identification of cores U0/U=0,6/1kV,Um=1,2kV Colour marking . .brown, black, grey According to HD 308 S2:2002. Standards SFS 4880, HD 603-3F S1, IEC 60502-1, IEC 60332-1 Certificate/approval Temperature range Highest permissible conductor temperature: – in continuous operation . . . . . . . . . . . . . . . . . . . . . . . 70˚C – in a short circuit (duration up to 5 s) . . . . . . . . . . . 160˚C Lowest recommended temperature during laying. . . –15˚C Basic cable data EAN code Construction data External cable diameter (1) Weight (1) Delivery data Standard delivery length Drum Total weight (1) cable + drum Mechanical data (2) Min permissible bending radius during laying Min permissible bending radius at final installation (3) Max permissible pulling force, pulling by phase conductors Electrical data (2) Maximum DC resistance of conductor 20˚C Maximum AC resistance of conductor 70˚C Maximum DC resistance of PE conductor 20˚C Inductance (1) Operating capacitance (1) Current ratings (2) In ground conductor 70˚C In air conductor 70˚C Short circuit currents (2) Max permissible short circuit current for 1 second phase conductor (4) PE conductor (5) Manufacturer, product name, FI-mark, year and week of manufacture, meter marking MCMK MCMK MCMK 3x1,5/1,5 1 kV 3x2,5/2,5 1 kV 3x6/6 1 kV 06 021 52-9 06 021 53-6 06 021 55-0 MCMK MCMK 3x10/10 RM 1 kV 3x16/16 RM 1 kV 06 021 56-7 06 021 57-4 mm kg/km kg/km 12 54 190 13 88 240 17 212 450 20 357 680 23 570 970 m kg 1000 K8 220 1000 K9 290 500 K8 260 500 K9 390 500 K11 570 m m kN 0,15 0,10 0,22 0,16 0,11 0,37 0,21 0,15 0,90 0,24 0,16 1,5 0,28 0,19 2,4 Ω/km Ω/km Ω/km mH/km µF/km 12,1 14,5 12,1 0,34 0,25 7,41 8,87 7,41 0,32 0,30 3,08 3,69 3,08 0,30 0,35 1,83 2,19 1,83 0,28 0,40 1,15 1,38 1,15 0,26 0,40 A A 26 14 35 20 57 33 77 62 100 82 kA kA 0,18 0,24 0,30 0,42 0,7 1,0 1,1 1,7 1,8 2,7 64 100+ copper cable Marking 1) Approximate value. 2) See the basic assumptions at general information of products. 3) Final installation with careful single bending. 4) Initial temperature of conductor before short circuit 70˚C, final temperature of conductor after short circuit 160˚C. 5) Initial temperature of PE conductor before short circuit 60˚C, final temperature of PE conductor after short circuit 160˚C. AS Draka Keila Cables www.draka.ee Member of Prysmian Group www.prysmian.com Paldiski Road 31 76606 Keila, Estonia Phone +372 674 7466 Fax +372 674 7468 The technical specifications may change any time without prior notice.
© Copyright 2026 Paperzz