Figure 6010.511 - Rectangular Area Intake

1
Install four #4 diagonal bars at all pipe openings.
2
Cast-in-place base shown. If base is precast integral
Form Grade
SW-604 Type 6
Casting
with walls, the footprint of the base is not required
12’’
ope
Sl
to extend beyond the outer edge of the walls.
’ per foot
’
3
12 inch minimum wall height above all pipes.
4’’
4’’ 4’’
#4 bars
A
Adjustment
Rings
Location Station
SW-604 Type 6 Casting
3
12’’ min.
4"
#4 Bars at 15’’
o.c. Each Way
Invert
Diagonal Bar
1
Short Wall
2’-0’’
(typ.)
3’-0’’
2
Base
4’’
6’’ min.
8’’ min.
#4 Bars at 12’’
Short Wall
6’’
2’-0’’
A
o.c. Each Way
6’’
Long Wall
3’-0’’
3’-0’’
4’-0’’
PLAN
SECTION A-A
FIGURE 601
0.
511 SHEET 1
OF 1
REVISION
NEW
FIGURE 6010.511 STANDARD ROAD PLAN
04-21-09
SW-511
SHEET 1 of 1
MAXIMUM PIPE DIAMETERS
REVISIONS:New. Replaces SUDAS Area Type ’’M-H’’ Intake
Pipe
Precast
Cast-in-place
Location
Structure
Structure
Short Wall
15’’
18’’
Long Wall
24’’
30’’
SUDAS DIRECTOR
DESIGN METHODS ENGINEER
RECTANGULAR AREA INTAKE