Confidential Sekisui # 2876 Page 1 of 6 EPT TECHNICAL REPORT ON PROPERTY TESTING OF FOIL COMPOSITE SAMPLE Client: Sekisui Pilon Pty Ltd 1-5 Parraweena Rd., Taren Point, NSW 2229 (ExcelPlas Job # 2876) 473 Warrigal Road (Rear factory) Moorabbin VIC 3189 www.excelplas.com 6 December 2012 COMMERCIAL-IN-CONFIDENCE EXCELPLAS POLYMER TECHNOLOGY Confidential Sekisui # 2876 Page 2 of 6 EPT 1. Objective The objective of this study is to measure the puncture resistance, tear resistance and tensile properties of a foil composite material. 2. Samples Supplied One sample of foil composite was supplied by Sekisui for property testing. The identification of the sample was: Client Reference: Thermobreak No-Clad Description: Reinforced Aluminium Foil Composite Colour: Silver Nominal Composition: PE Bonding Layer / Glass Cloth Reinforcement / Aluminium Foil / UV Protection 3. Testing Undertaken The following test methods were used: Puncture testing was undertaken according to ASTM D 4833 (Rod Puncture) Tear testing was undertaken according to ASTM D 751 Procedure B (Tongue Tear Method) Tensile testing was undertaken according to ASTM D 751 Procedure A (Grab Method) 4. Method of Sampling. Specimens were taken from across the entire sample. For the tear and tensile tests, specimens were taken in perpendicular directions in line with the edges of the sample, and assigned as Direction 1 and Direction 2. EXCELPLAS POLYMER TECHNOLOGY Confidential Sekisui # 2876 Page 3 of 6 5. Test Results 5.1 Rod Puncture Client: ExcelPlas Job Number: Sample: Method: Sekisui # 2876 Thermobreak No-Clad ASTM D 4833 Puncture Resistance Maximum Force (N) Specimen 1 475 Specimen 2 453 Specimen 3 417 Specimen 4 382 Specimen 5 431 Mean 432 Standard Deviation 35 EXCELPLAS POLYMER TECHNOLOGY EPT Confidential Sekisui # 2876 Page 4 of 6 5.2 Tear Testing (Tongue Tear Method) Client: ExcelPlas Job Number: Sample: Method: Direction 1 Sekisui # 2876 Thermobreak No-Clad ASTM D 751 Tearing Strength (Procedure B) Tearing Strength (N) Specimen 1 63.6 Specimen 2 70.3 Specimen 3 63.6 Specimen 4 53.6 Specimen 5 59.3 Mean 62.1 Standard Deviation 6.2 Client: ExcelPlas Job Number: Sample: Method: Direction 2 Sekisui # 2876 Thermobreak No-Clad ASTM D 751 Tearing Strength (Procedure B) Tearing Strength (N) Specimen 1 46.1 Specimen 2 44.4 Specimen 3 55.2 Specimen 4 54.8 Specimen 5 61.6 Mean 52.4 Standard Deviation 7.1 EXCELPLAS POLYMER TECHNOLOGY EPT Confidential Sekisui # 2876 Page 5 of 6 5.3 Tensile Testing (Breaking Strength – Grab Method) Client: ExcelPlas Job Number: Sample: Method: Direction 1 Sekisui # 2876 Thermobreak No-Clad ASTM D 751 Breaking Strength (Procedure A) Maximum Force (N) Specimen 1 711 Specimen 2 831 Specimen 3 684 Specimen 4 1040 Specimen 5 1280 Mean 909 Standard Deviation 250 Client: ExcelPlas Job Number: Sample: Method: Direction 2 Sekisui # 2876 Thermobreak No-Clad ASTM D 751 Breaking Strength (Procedure A) Maximum Force (N) Specimen 1 929 Specimen 2 1190 Specimen 3 969 Specimen 4 944 Specimen 5 1120 Mean 1030 Standard Deviation 120 EXCELPLAS POLYMER TECHNOLOGY EPT Confidential Sekisui # 2876 Page 6 of 6 EPT Matthew Matin, Senior Laboratory Technician, ExcelPlas Pty. Ltd. ExcelPlas Polymer Technology & Testing, Address: 473 Warrigal (Rear factory), Moorabbin, VIC 3189 Australia Email address: [email protected] p. +613-9532-2207 Terms & Conditions: The testing herein is based upon accepted industry practice as well as the test methods listed. Test results reported herein do not apply to samples other than those tested. ExcelPlas neither accepts responsibility for nor makes claim as to the final use and purpose of the material. It is up to the client to validate the suitability of any material recommendations contained in this report by conducting proper product field trials to establish 'fitness for purpose' to their satisfaction. ExcelPlas shall not be liable for any losses, costs, damages or expenses incurred by the recipient or any other person or entity resulting from the use of any information or interpretation given in this report. ExcelPlas observes and maintains client confidentiality. ExcelPlas limits reproduction of this report, except in full, without prior approval of ExcelPlas. ExcelPlas Pty. Ltd. is dedicated to Customer Service and welcomes your feedback. Please email [email protected] to send us your suggestions or comments. We thank you for your time. EXCELPLAS POLYMER TECHNOLOGY
© Copyright 2026 Paperzz