dolphin panel mounted electronic infrared tap

M23x1
170
155
550 MAX
52
Power
Source
DB400 / DB425
DOLPHIN PANEL MOUNTED ELECTRONIC INFRARED TAP
› WRAS Approved product
› Touch Free Tap – for ultimate hygiene – prevents cross contamination
› Quality polished or brushed chrome plated brass finishes available from stock – other
finishes available to special order
› Water Supply: Single inlet cold or pre-mixed – a TMV2 or TMV3 thermostatic mixing valve
is recommended for premixed applications
› Flow rate – 3.8 litres/minute with our standard fitted flow regulator at any pressure
between 0 and 6 bar (other flow rates available to special order – please enquire)
DIAMETER
PROJECTION
50
MM
170
MM
› Power Source: 6 x AA Battery / plug in 9v Transformer
› Power Connections: tap female, power source male
› Operating pressure 0.5 - 8.0 bar (7 - 116 PSI)
› Maximum water temperature 70ºC
› Flow time once user's hands are removed from the tap - 1 second (adjustable by using
remove control DB51)
› Interchangeable STD M22/24 Neoperl Aerator insert
› Tap settings may be adjusted by using remote control (DB51)
PRODUCT CODES
BATTERY POWERED
› Mandatory Hygiene Flush feature can be specified to combat Legionella
› Polished Chrome Plate
› 2 year manufacturer’s warranty
› Brushed (Satin) Chrome Plate
› Complies with SKA rating criteria
› To special order we can supply a threaded tail extension kit
› Our low flow taps are fully BREEAM compliant and contribute to up to five BREEAM WAT
1 credits.
› Listed on the Government's Water Technology List (WTL) as part of the Enhanced Capital
Allowance (ECA) scheme. This allows businesses purchasing these product to benefit from
100% first year capital allowances on this expenditure.
DB400C
DB400S-2
TRANSFORMER POWERED
› Polished Chrome Plate
› Brushed (Satin) Chrome Plate
DB425C
DB425S-2
TECHNIC AL HELPLINE
01424 202224
DOLPHINSOLUTIONS.CO.UK
Ø50
M23x1
170
Ø38
155
550 MAX
52
Power
Source
BELL-CHEM PRODUCTS COMPANY
DOLPHIN BLUE PANEL MOUNTED ELECTRONIC INFRARED TAP
DB400 / DB425
DB400 Dolphin Blue Panel Mounted Electronic
Infrared Tap
Spare parts can be obtained only by ordering the relevant kit. Spare parts cannot be ordered individually. In
order to locate the relevant spare part, please check the corresponding part and part number at the drawing at
the last page. When ordering spare parts (kits) please mention the corresponding catalog number (Cat. No.).
Quantity
Part Number Description
Cat. No.
-
Seals and Screws Kit
DB 07210015
1
2
O-ring
DB 04510193
1
5
O-ring
DB 04510078
1
4
O-Ring
DB 04510297
1
3
Screw
DB 05010405
1
6
Screw
DB 05010316
-
Self Adaptive Sensor Kit
DB 07220239
1
1
Self Adaptive Sensor
DB 08002325
1
2
O-ring
DB 04510193
-
Solenoid BS-Housing Kit/
DB 07231008/
Solenoid BS-Housing Kit USA
DB 07231009
1
7
Solenoid valve’s body
DB 07502019
1
8
Filter
DB 08530013
1
9
Nipple
DB 07025015/
DB 07025078
-
Solenoid Valve Kit
DB 07230017
1
11
Solenoid valve
DB 07500025
1
10
Diaphragm
DB 04500001
10
Diaphragm
DB 04500001
Haywood Way, Ivyhouse Ind Est,
Hastings, TN35 4PL
[email protected]
www.dolphindispensers.co.uk
DOLPHIN
Southpoint, Compass Park, Bodiam,
Robertsbridge TN32 5BS
[email protected]
www.dolphindispensers.co.uk
DOLPHIN
INSTALLATION AND MAINTENANCE GUIDE
Dolphin Blue
Infrared Taps
Saving water and energy
promoting hygiene
Panel mounted electronic tap for cold or premixed water
DB/L/XL 400 DB/L/XL 425 DB 450/475
Important:
Read carefully before installing product
DOLPHIN
Revision March 2013
CONTENTS
3
Technical Data
4-5
Pack Contents
6
Pre-Installation Information
7
Pre-Installation
8 - 10
Tap Installation DB/L/XL 400 + 425
11-13
Tap Installation DB 450 + 475
14-16
Setting Adjustment
17
Battery Replacement
To replace the battery of DB/L/XL 400 + 450 models
18
Maintenance
Filters cleaning instructions
Care and cleaning of chrome and special finshes
19
Spare Parts List
Limited Warranty
20
Trouble Shooting
2 | Dolphin Blue | 400 Series
TECHNICAL DATA
Wall mounted electronic tap for cold or premixed water
Power Supply
Battery a.
6x1.5AA battery (DB/L/XL 400 models)
Battery b.
1x9V (PP3) battery (model DB 450)
Transformer
9v transformer (DB/L/XL 425 + DB 475 models)
Recommended
0.5-8.0 bar (7-116 PSI)
Water Pressure
With water pressure of more than 8 bars
use a pressure reducing valve
Sensor range
Self adjusting sensor. Adjustable with remote control
Minimum sensor range
80mm
Maximum sensor range
300mm
Security time
90 seconds. Can be changed with the DB50 remote control
Hot water temperature
Max 70ºC
400 Series | Dolphin Blue | 3
PACK CONTENTS
DB/L/XL 400 DB/L/XL 425
1 x Spout and attachment (inc electronic unit)
1 x Wall rosette
1 x Tap base
1 x M4x6 screw
1 x Allen key
1 x Solenoid housing
kit with filter adaptor
DB/L/XL 400
4 | Dolphin Blue | 400 Series
DB/L/XL 425
PACK CONTENTS
DB 450 DB 475
1 x Spout and attachment (inc electronic unit)
1 x base with support
3 x screws
(6 x 11/2")
1 x wall
rosette
1 x Allen key
DB 450
DB 475
4 x screws
1 x panel
1 x temporary protective cover
Required (not supplied) rigid
pipe, cable sleeves
400 Series | Dolphin Blue | 5
PRE INSTALLATION INFORMATION
Check Contents
Separate all parts from the packaging and check you have each part according to the
pack contents section, pages 4-6. Pay attention to the variations of the different models.
Make sure all parts are accounted for before discarding any packaging material.
If any parts are missing, do not attempt to install your electronic tap.
Please call 0800 0723 404 immediately to notify us.
Warning
1) To avoid reflection problems keep a distance
of more than 300 mm. between the sink and the
spout.
2) This tap model, with an infrared sensor
pointing down, is not intended to be used
together with a sink of a reflective material such
as stainless steel.
3) If a sink strainer is straight below the tap
sensor, use a strainer with a non reflective finish
(do not use a chrome plated one).
Preparation for installation
Flush water supply lines thoroughly before installing the tap.
Do not allow dirt, Teflon tape or metal particles to enter the tap.
Shut off water supply.
Important
All plumbing is to be installed in accordance with applicable codes and regulations.
6 | Dolphin Blue | 400 Series
PRE INSTALLATION
Warning
● To
avoid reflection problems it is recommended to keep a distance of more
than 300mm between the sink and the spout. If the distance is below 300mm
a simple mock-up should be effected to confirm the tap functions as desired
in your application before final installation. You may require a Dolphin Blue
remote control to adjust the range.
● Do
not connect water or power supplies or remove the black label
covering the infra-red sensor until you have read and understood
these instructions. Please see page 13.
● It
is not recommended to use DB400 series with a polished stainless steel
sink. For this type of application a separate panel-mounted sensor should be
used – please speak to our technical sales team.
● Please
observe the guide to minimum cavity depths as shown in the table.
This is important because the water supply hose must not be kinked due to
lack of space. Please note we have provided this information as a guide and
cannot be held responsible for fundamental design errors. If your situation
differs to those shown below please call us on 0800 0723 404, and we will
provide you with a solution.
Panel thickness (A)
B
A
Minimum void (B)
10-15mm
80mm
16-25mm
70mm
26-35mm
60mm
400 Series | Dolphin Blue | 7
TAP INSTALLATION
Installation instructions for DB/L/XL 400 + DB/L/XL 425
Step 1 – Installing the tap
1. Shut off the water supply
2. Drill a hole (23 to 24 mm) at the place where you want to install the spout of the
tap.
3. If your model includes an optional anti-rotation pin, drill a small hole just above
the previous one for the anti-rotation pin.
M3
14.4
M23x1
51.0
4. Insert the tap and its attachments through the wall. The aerator at the tap spout
must face the washbasin.
5. Insert the anti-rotation pin into the small hole (if needed)
6. Fix the base behind the wall with the hexagonal nut and the disk.
8 | Dolphin Blue | 400 Series
TAP INSTALLATION
Step 2 – Connecting the Water Supply
1. Fit the flexible pipe coming from the Tap base to the
Water inlet
solenoid valve housing.
2. Fit the water supply inlet to the adapter at the
solenoid valve housing. Inlet and outlet should
follow the indicating arrow at the solenoid housing.
Filter
Note: Make sure the filter is located at the solenoid
inlet.
Water inlet
3. Connect the cable coming from the electronic unit
to the solenoid valve.
Important: Tap was supplied with a Self Adjusting Sensor. The ideal sensor range
for the specific location will be set automatically.
Before proceeding to step 3 check that
Now, remove the protecting
no objects are in front of the sensor
sticker that covers the sensor.
besides the washbasin.
400 Series | Dolphin Blue | 9
TAP INSTALLATION
Step 3 – Connecting the Power Source
1a. For DB/L/XL 400: Connect the other cable coming
from the electronic unit at the Tap base to the
battery box.
1b. For DB/L/XL 425: Connect the other cable coming
from the electronic unit at the Tap base to the
transformer. Plug the transformer into the
electricity socket.
2. After you have connected the power source
(Battery or Transformer) wait 15 seconds in order
to allow the system to set the ideal sensor range.
As an indication that the self adjusting is taking place, a red light in the sensor eye
will flash continuously. The solenoid valve will be opened and closed for 1 second
as an indication that the ideal sensor range was set and the product is ready for
use.
3. Turn on the central water supply. Check for leaks.
Note: This tap includes a special aerator that allows you to adjust the water
stream direction on site in order to prevent water splashing if needed. To change
the angle of the water stream, simply move the adjustable
tilting plate by pressing it smoothly.
4. If the automatically adjusted sensor range is not
satisfactory, please refer to the section entitled “Settings
adjustment”.’.
10 | Dolphin Blue | 400 Series
TAP INSTALLATION
Installation instructions for DB450 and DB 475
Step 1 – Installing the Tap
1. Shut off the water supply
2. Cut an adequate opening in the
wall according to the dimensions
of the tap box, the cables sleeve,
the rigid pipe and the tap base
with the support (at the place
where you want to install the
spout).
3. Cut two small holes for the tap
base support and drive the
anchors in.
4. Insert the tap box through the wall. Connect the water supply pipe to the nipple at
the bottom of the tap box.
5. Mount the tap base with the support through the wall opening, and secure the
base support to the two small holes using 2 screws.
Important: The tap base should be installed so that the outside surface of the
finished wall falls between the minimum and maximum lines marked at the base.
6. Assemble the rigid pipe from the nipple at the box to the inlet at the tap base.
7. Pull the wires of the power supply (transformer/battery) and sensor cable out of
the tap base.
8. Lead the wires through the cable sleeve.
9. Connect the electronic unit’s connector coming from the tap base to the solenoid’s
connector.
400 Series | Dolphin Blue | 11
TAP INSTALLATION
10.If your model is DB 475, connect the power supply connector from the electronic
unit coming from the tap base to the transformer.
11.Assemble the temporary protective cover panel to the tap box.
12.Once the works on electricity, plumbing and tiles have been finished, insert the
wall rosette through the tap base.
13.Connect the cable leading to the solenoid and the power supply cable at the spout
to those at the tap base. Fix the tap spout by inserting the nipple into the tap base.
Make sure that this area is clean before proceeding. Secure the screw with the
Allen key. Make sure that the aerator at the tap spout will be installed facing the
washbasin.
Step 2 – Connecting the power source
1. Remove the temporary protective cover panel.
Important: tap was supplied with A Self Adjusting
Sensor. The ideal sensor range for the specific
location will be set automatically. Right now, check
that no objects are in front of the sensor besides the
washbasin.
2. Now remove the
protecting sticker that covers the sensor.
3. If your model is DB 450 the battery box is attached
to the cover panel. Connect the battery box
connector to the electronic unit connector.
4. If your model is DB 475, plug the transformer into
the electricity socket.
12 | Dolphin Blue | 400 Series
TAP INSTALLATION
5. After you have connected the power source
(Battery or Transformer) wait 15 seconds in order
to allow the system to set the ideal sensor range.
As an indication that the self adjusting is taking
place, a red light in the sensor eye will flash
continuously. The solenoid valve will be opened
and closed for 1 second as an indication that the
ideal sensor range was set and the product is
ready for use.
Step 3 - Connecting the water supply
1. Turn on the central water supply.
2. Check for leaks.
3. Assemble the wall cover panel by screwing the four screws.
Note: This tap includes a special aerator that allows you to adjust the water
stream direction on site in order to prevent water
splashing. To change the angle of the water stream, simply
move the adjustable tilting plate by pressing it smoothly.
4. If the automatically adjusted sensor range is not
satisfactory, please refer to the section entitled “Settings
adjustment”.
400 Series | Dolphin Blue | 13
SETTING ADJUSTMENT
Detection Range
Delay Out Time
Delay In Time
Temporary Off Function
Entrance to the Self
Adjustment Mode
Reset
Lock Out Time
24 Hour Hygiene Flush
Adjusting the settings with the remote control
If necessary, the sensor settings can be adjusted as following:
Shut off the water supply. In order to adjust the sensor with the remote control, hold
the remote control straight in front of the sensor in a distance of about 6-8”
(15-20cm). Choose the function you want to adjust by pressing once on one of the
function buttons. After pressing once on a specific function button, a quick flashing of
the red light at the front of the sensor will occur. At this stage, you can change the
setting by pressing the (+) or the (-) buttons, every push will increase or decrease one
level. After finishing the adjustment, turn the water supply back on.
14 | Dolphin Blue | 400 Series
SETTING ADJUSTMENT
DETECTION RANGE: This tap was supplied with a Self Adjusting Sensor.
The ideal detection range for the specific location will be set
automatically.
Only if necessary, use the remote control to adjust the sensor range as
follows: Press the RANGE button. Wait until a quick flashing of the red light of the
sensor eye is perceived. Then, press + to increase the delay out time and – to reduce it
every push will increase or decrease one level.
Note: Once you have changed the detection range with the remote control, this
distance will be remembered by the sensor, even if the power source is
disconnected. To get back to the self adjustment mode, use the ADJ button only.
ENTRANCE TO THE SELF ADJUSTMENT MODE: Check that no objects
are in front of the sensor. Press the ADJ button. Once a quick flashing of
the red light of the sensor eye is perceived, remove your hand holding the
remote control and move away from the sensor area. The ideal sensor range for the
specific location will be set automatically. Once the self adjustment has taken place
the solenoid valve will be opened and closed for 1 second as an indication that the
ideal sensor range was set and the product is ready for use.
SECURITY TIME: The Security time, prevents continuous running of
water due to reflections or vandalism. By default, if the sensor is
covered for more than 90 seconds the water flow will shut
automatically. To resume regular operation any obstruction must be removed.
Press the SEC button. Wait until a quick flashing of the red light of the sensor eye is
perceived. Then, press + to increase the security time and – to reduce it.
400 Series | Dolphin Blue | 15
SETTING ADJUSTMENT
DELAY IN TIME: It is recommended to change the delay in time for flush
valves for urinals or toilets only.
If required, the delay in time can also be modified in taps as follows:
Press the IN button. Wait until a quick flashing of the red light of the sensor eye is
perceived. Then, press + to increase the delay in time and – to reduce it.
DELAY OUT TIME: This button allows modifying the water flow time after
the user removes his hands from the tap. A delay out time close to 0 will
save more water. An increased delay out time will make the user
experience more comfortable. If required, the delay out time can be modified as
follows: Press the OUT button. Wait until a quick flashing of the red light of the sensor
eye is perceived. Then, press + to increase the delay out time and – to reduce it.
24 HOUR HYGIENE FLUSH: If you have a compatible model with a 24
hours hygiene flush it is possible to enable and disable it .
To activate the hygiene flush, press the clock button. Wait until a quick
flashing of the red light of the sensor eye is perceived. Then press + to activate the
hygiene flush or – to deactivate it.
TEMPORARY OFF FUNCTION: This function is ideal to perform any kind
of activity in front of the sensor without operating the system (for
example, cleaning).
The tap will remain shut for 1 minute when this button is pressed once. To cancel this
function and to return to normal operation press the On/Off button again or wait
1 minute.
RESET BUTTON: This function restores all the factory settings except for
the sensor range. If required, press the Reset button and without releasing
it, press the + button once.
Note: To enter the self adjusting mode, use the ADJ button. To change the sensor
range, use the RANGE button.
16 | Dolphin Blue | 400 Series
BATTERY REPLACEMENT
Battery models only
When the battery weakens, the red indicator light will blink at a constant
rate when the user’s hands are within the sensor range. The battery must
be replaced within two weeks.
To replace the battery (battery models only):
1. For DB/L/XL 400: Open carefully the batteries’ box and remove the old batteries.
Replace the used batteries with six new 1.5V AA batteries. Close the box.
2. For DB 450: Release the screws at the panel and remove it. The battery box is
located behind the panel. Open carefully the battery’s box and replace the used
battery with a new 9V battery (Lithium battery is recommended). Close the box
and re-assemble the wall cover panel.
Important: Tap was supplied with A Self Adjusting Sensor. The ideal sensor range
for the specific location will be set automatically again after changing the battery.
After you have
Check that there are no objects in
front of the sensor after the battery
replacement was completed.
replaced the battery,
move away from the
sensor range. Wait
15 seconds in order
to allow the system to set the ideal
sensor range. Then after the self
adjustment has taken place the
solenoid valve will be opened and
closed for 1 second as an indication
that the ideal sensor range was set and
the product is ready for use.
Important: Spent batteries should not be disposed of with normal
household waste. Contact your local authority for information on
waste disposal and recycling.
400 Series | Dolphin Blue | 17
MAINTENANCE
Filter Cleaning Instruction
This tap is provided with a stainless steel filter preventing foreign particles to enter
the lines. If the water flow has decreased, this may be because the filter is clogged.
The filter can be cleaned as follows:
1. For DB/X/XL 400 + 425:
a. Shut-off the water shut off valve.
b. Disconnect the water supply pipe from the adaptor and disassemble the filter
from it.
c. Wash the filter under running water.
d. Reassemble the parts.
e. Restore the incoming water supply.
f. Make sure that there is no water leakage.
2. For DB 450 + DB 475
a. Release the screws at the panel and remove it. Turn off the regulating valve.
b. Disassemble the solenoid valve by opening the nuts.
c. Remove the filter and wash it under running water.
d. Reassemble the filter.
e. Reassemble the solenoid valve.
f. Turn on the regulating valve and adjust the flow capacity.
g. Make sure that there is no water leakage. Re-assemble the wall cover panel.
Care and cleaning of chrome and special finishes
DO NOT use steel wool or cleansing agents containing alcohol, acid, abrasives, or the
like. Use of any prohibited cleaning or maintenance products or substances could
damage the surface of the tap. For surface cleaning of tap us ONLY soap and water,
then wipe dry with clean cloth or towel. When cleaning bathroom tile, the taps should
be protected from any splattering of harsh cleansers.
18 | Dolphin Blue | 400 Series
SPARE PARTS LIST
Self adjusting sensor kit ............................................................................. Cat.No. DB 07220056
Solenoid valve kit ............................................................................................ Cat.No. DB 07230017
Solenoid housing kit for DB/L/XL 400 + 425 ............................... Cat.No. DB 07231008
Transformer ......................................................................................................... Cat.No. DB 06522042
IP67 Battery box .............................................................................................. Cat.No. DB 06522020
Diaphragm ........................................................................................................... Cat.No. DB 04500001
Optional accessories
Remote control ................................................................................................. Cat.No. DB 07100005
Battery box for 1 x 9V battery ............................................................... Cat.No. DB 06530008
IP67 Transformer box with transformer .......................................... Cat.No. DB 06530021
Transformer junction box........................................................................... Cat.No. DB 06530013
Transformer junction box exit with
3 meter cable and male connector ..................................................... Cat.No. DB 06000084
Mixing valve ...................................................................................................... Cat.No. DB 200070
LIMITED WARRANTY
This product is covered by a limited warranty for two years from the date of purchase.
If a BCP product is determined by an authorised BCP technician to be defective either in
materials or in workmanship, BCP will replace or cover costs for repair of the product at
its own discretion. If replacement or repair is not feasible, BCP will refund the original
purchase price of the product.
This warranty does not cover products that have not been installed in accordance with
BCP’s installation guide, or products that have been damaged through abuse, misuse,
misapplication, wear and tear and battery or water compositions. This includes (but is
not limited to) the following:
• Incorrect installation, inversions of supply pipes.
• Pressures or temperatures exceeding recommended limits.
• Improper manipulations, tampering, bad or lapsed maintenance.
• Foreign bodies, dirt or scale introduced by the water supply.
400 Series | Dolphin Blue | 19
TROUBLE SHOOTING
PROBLEM
No water
coming
out of the
tap
INDICATOR
1. Sensor flashes
continuously when
user’s hands are within
the sensor’s range
2. Red light in the
sensor does not flash
when user’s hands are
within the sensor’s
range
3 Red light in the
sensor flashes when
user’s hands are within
the sensor’s range
Water flow
from spout
does not
stop
1 Sensor flashes when
user’s hands are
within the sensor’s
range
2 Red light in the
sensor does not flash
when user’s hands
are within the
sensor’s range
Water flow
diminished
CAUSE
Low battery
SOLUTION
Replace battery
1 Range is too short
2 Range is too long
3 Battery is completely used up
4 Unit is in ‘security mode’*
5 Sensor is picking up
reflections from the
washbasin or other objects
1 Connectors between the
electronic unit and solenoid
are disconnected
2 Debris or scale in solenoid
Increase the range
Decrease the range
The battery must be replaced
3 The central orifice in the
diaphragm is plugged or the
diaphragm is torn
4 The water supply pressure is
higher than 8 bar
Debris or scale in diaphragm
1 Sensor is dirty or covered
2 Sensor is picking up
reflections from the
washbasin or another object
Filter or aerator clogged
Eliminate cause of reflection
Connect the electronic unit
connectors to the solenoid
Unscrew solenoid, pull out
the plunger and the spring
from the solenoid and clean
them. Use scale remover
material if needed. When
replacing the plunger, please
make sure the spring is in
the vertical position.
Clean the orifice or replace
diaphragm
Reduce the supply water
pressure
Clean the orifice or replace
diaphragm
Clean or eliminate cause of
interference
Decrease the range or
eliminate cause of reflection
Remove, clean or re-install
*‘Security mode’: If the sensor is covered for longer than the specified security time, the tap will automatically shut off water flow.
To return to normal operation remove any blockage to re-establish operation
20 | Dolphin Blue | 400 Series
DOLPHIN
Soap
Dispensers
Page 5
Taps
DOLPHIN
Hot Air Hand Combination
Paper Towel Toilet
Dryers
Units
Tissue
Dispenser
Dispenser
Counter Mounte
d
105
100
142
135°
Ø45
Taps
Ø50
Grab Rails
Baby
Changing
Hotel Range
s
Consumable
Product
Families
Installation
Guide
• Touch Free Tap
– for ultimate hygiene
– prevents cross
contamination
• Quality polished
chrome plated brass
or lacquered nickel
plated brass finishes
available
• Water Supply:
Single inlet cold or
pre-mixed – a TMV2
TMV3 thermostatic
or
mixing valve is recommende
premixed applications.
d for
For 2 inlet hot and
cold feed see
page 183
• Flow rate – 6 litres/minute
(down to 1.89 litres/minute
please specify at
–
time of ordering)
• Neopearl Aerator
• Tap settings can
be adjusted manually
or by using remote
control (DB51 – see
page 188)
• Mandatory Hygiene
Flush feature can
be specified to
combat Legionella
– please specify at
time of orering
• WRAS Approved
Product
• 2 year manufacturer
’s warranty
• Maximum water
temperature 70ºC
• Operating pressure
0.5–8.0 bar (7–116
PSI)
Related items
Washroom
Accessories
Bins
Power
source
DB 200 / DB 225
Dolphin Blue Infrared
Tap
DB 200
page 178
178 Dolphin Dispensers
DBL 400
page 180
WP 106
page 11
Product Data
• H 142 x Ø 45 mm
• Projection 105mm
• Power Connections:
tap male, power
source female
• Counter hole Ø
28-34mm Min-max
thickness 2-27mm
• 3/8" BSP water
supply connector
• Power: Plug-in
9 volt transformers
or 9 volt battery (with
low battery warning)
– for other power
source options see
page 190-191
Product Codes
Polished chrome
finish
• Powered by 6
x AAA / 9v PP3 battery
• Powered by 9v
plug in transformer
Request your 320 page
catalogue today on
0800 0723 404
DB 200C
DB 225C
Brushed nickel finish
(designed to match
brushed stainless
steel)
• Powered by 6
x AAA / 9v PP3 battery
DB 200S
• Powered by 9v
plug in transformer
DB 225S
WP 208R
page 12
WP 112R
page 105
Technical helpline
BC 2006
page 159
01424 202224
Bell-Chem Products Company
Haywood Way, Hastings TN35 4PL
Tel: +44 (0)1424 202224
Fax: +44 (0)1424 205 200
[email protected]
www.dolphindispensers.co.uk
DB400 - DB 1400 series
Tap Solenoid Inspection Instructions
User Manual
Please read carefully before use
DOLPHIN
Tap Solenoid Inspection Instructions for Panel Mounted Taps
Turn off water supply before removing the solenoid.
Unplug the solenoid connector (red arrow)
Unscrew the solenoid (yellow arrow)
Please ensure that the flow direction arrow (green circle) is pointing towards the tap. The solenoid
WILL NOT WORK if the fitting is reverse plumbed! The tap will continuously flow at a reduced rate.
The diaphragm is then accessible.
It can be seen that leaking can be caused by very small particles. The larger the particle the faster
the tap will be leaking.
Remove the diaphragm and inspect very closely for particles on the surface, and clean.
Take care not to lose the piston in the centre of the solenoid housing.
The solenoid seating in the tap body should also be checked for particle ingress.
The piston should click and hold down when pushed into the solenoid. If the tap has been leaking a
steady stream of water it is very likely to be that the piston spring has become dislodged.
If the piston does not hold in the depressed position it should be carefully removed to reveal the
small spring beneath it. If it is lying on its side across the base, rather than standing upright as
shown, it should be removed with a small slotted screwdriver.
Do not deform the spring but allow the coils to grip the screwdriver blade.
Occasionally there is no debris causing the leak but the spring needs to be carefully stretched 1mm
to give increased pressure on the diaphragm. Take great care not to deform the spring.
Replace the piston with the spring inserted into the piston base.
Holding the solenoid housing upside down, and inserting the piston swiftly will assist this operation.
The solenoid housing should then be reassembled and replaced in the tap body.
If the tap is still leaking please recheck the diaphragm for particles as the smallest contamination will
cause leaking. Also wipe the diaphragm to remove any greasy deposits that may be present.
A new diaphragm should be fitted if the tap is still leaking after thorough inspection and cleaning.
Bell-Chem Products Company
Southpoint, Compass Park, Bodiam
Robertsbridge TN32 5BS
Tel: 01424 202224
Fax: 01424 205200
www: dolphindispensers.co.uk
[email protected]
DOLPHIN
Dolphin Blue Infrared Taps
The majority of Dolphin Infrared Taps are now equipped by
default with Neoperl Cascade PCA aerator which incorporates
a 3.8 litre per minute flow regulator.
Flow rate graph for Dolphin Blue Taps
8
Flow rate (Litres / Minute)
7
6
5
4
3
2
1
0
0
1
2
3
4
5
Line Pressure (Bar)
Pressure Range for Dolphin Blue Taps – 0.5 - 8.0 bar
(7-116 PSI).
Other flow rate regulators are available on request.
Please call the Dolphin Blue Technical Helpline on
01424 202224 for assistance.
Flow rate graph for Dolphin Blue Taps
8
7
Flow rate (Litres / Minute)
For areas where the pressure is greater than 8 bar,
use a pressure reducing valve.
6
5
4
3
2
1
0
0
1
2
3
4
5
Line Pressure (Bar)
A 6 L/M aerator and flow regulator is still
fitted to some models of the Dolphin Blue
infrared tap range.
DOLPHIN
Bell-Chem Products Co • Haywood Way • Hastings • East Sussex TN35 4PL
Tel: 01424 202224 • Fax: 01424 205 200
[email protected] • www.dolphindispensers.co.uk
Dolphin Blue
Infrared Systems Important Design Tips
DOLPHIN
Dolphin Blue Infrared Systems
Designing a washroom including Dolphin Blue Infrared Systems
Dolphin Blue Infrared Taps, Shower Controls and Urinal Flush Valves offer
significant water and energy savings. However, there are some simple
DO’s and DON’Ts and TIPs which will help avoid 99% of the situations
often associated with infrared systems for washrooms.
It should be noted that these details are not exhaustive but will help
eliminate 99% of situations. It is recommended that for larger projects
especially where design restraints will result in taps being set on minimum
or maximum settings, we would advise a very simple mock-up be set with
materials to be used to ensure infrared device operates as desired.
DO’s
Battery Back up
Pressure
DO include a battery back-up device when
installing a transformer powered infrared
tap in an accessible washroom.
DO ensure the static and dynamic pressure
at the Dolphin Blue device is within the
tolerances stated on the product literature /
data sheet (please ask if you cannot find it).
Most devices are tested to operate between
0.5 and 8 bar. If pressures are outside the
stated tolerances please contact the
Technical Helpline on 01424 20 22 24.
Security Time
DO ensure security time is set at
approximately 20 seconds on infrared taps
especially in locations susceptible to
vandalism. Also important: to be set at 20
seconds to comply with ECA/WTL
scheme.
Flow Rate
DO specify what flow rate is required when
placing your order.
Taps - 6 litre / minute is standard. 4 litre /
minute is readily available.
Filters
Do ensure filters supplied with the Dolphin
Blue device are installed. It may not be
sufficient to rely on the filters often included
with thermostatic mixing valves as the
gauge of the filter mesh may not be fine
enough. It is also important to ensure
pipes are flushed prior to connection and
filters are inspected on a regular basis.
Time between inspections will depend on
hardness and quality of water.
Shower head - 9 litres/ minute is standard,
8 litres / minute is available.
Distance from Transformer
Please speak to the Dolphin Technical
Helpline for other flow rates if required.
It is recommended you ensure the
maximum distance between a Dolphin
Blue Infrared Tap and its power source is 5
metres.
DON’Ts
Mirrors
Panel Mounted Infrared Taps
It is not advisable to locate a Dolphin Blue
Infrared device directly opposite a mirror
where the infrared eye faces the mirror in
such a way that it could reflect itself as this
can cause false activations
even if the mirror is 2-4 metres
away from the infrared eye.
It is very important to ensure the distance
between the sensor and the bottom of
basin when installing a panel mounted
Dolphin Blue Tap with an integral sensor is
a minimum of 300mm
above the bottom of the
basin.
Two Infrared Taps
It is not advisable to locate
infrared taps directly opposite
each other where the infrared
eyes face each other as this
can also cause false activations
even when there is a fair
distance between them.
TIPs
Minimum 300mm
distance critical
Polished Traps and
Sink Surfaces
When installing a Dolphin
Blue Panel Mounted Tap
with an integral sensor it is
recommended that you
avoid a highly polished
chrome trap or sink
surface –
it will act like a mirror to
the tap sensor, potentially
causing false activations
and wasted water
Avoid polished/
chrome strainers
High Visibility Clothing
‘Tall’ Version Taps and Spout Lengths
It is a feature of most infrared devices in
the washroom market that the reflective
strips on high visibility clothing may cause
the device to operate, even if someone just
walks past, with no intention of using it.
Consider the position of the water outlet /
aerator in relation to the basin.
The DB51 Dolphin Blue Remote Control
can be used to reduce the range of a
device to reduce these false activations
but may not eliminate the phenomena
completely.
Please feel free to discuss
spout lengths with the
Dolphin Technical Helpline on
01424 2022 24.
washrooms worth experiencing
0800 0723 404
Bell-Chem Products Company
Haywood Way, Hastings, TN35 4PL
[email protected]
www.dolphindispensers.co.uk
DOLPHIN