Configuration Data Sheet: Rosemount 3051S MultiVariable

Rosemount 3051SMV
Configuration Data Sheet
May 2016
00806-0100-4853, Rev AB
Rosemount™ 3051S MultiVariable™ Configuration Data Sheet
with FOUNDATION™ Fieldbus protocol
 Select only one of the items provided
 One or more of the listed items can be selected
★ = Default
Customer information
Customer: ________________________________________________________
Contact name: ____________________________________________________
Phone no: _________________________________________________________
Fax no./email: _____________________________________________________
P.O./reference no.: __________________________________________________
P.O. line item: _____________________________________________________
Model no.: ____________________________________________________________________________________________________________________________
Customer sign-off: ______________________________________________________________________________________________________________________
Tagging
Hardware tag:
 Wire-on _______________________________________________________________________________________ (85 characters, A–Z, 0–9)
 Nameplate ____________________________________________________________________________________(120 characters, A–Z, 0–9)
Software tag:
_________________________________________________________________________________________________ (32 characters, A–Z, 0–9)
Transmitter information (optional)
Descriptor:
|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|(16 characters maximum)
|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|(16 characters)
Measurement type
Process measurements
1
Differential pressure/static pressure/process temperature
2
Differential pressure/static pressure
Based on the measurement type of the transmitter, complete only the necessary process measurements listed in the table above. For example, for measurement type 2
only fill out the differential pressure and static pressure units, LTV, and UTV.
Outputs
Differential pressure (inH2O @ 68 °F★)(1)
Units:
inH2O @ 60 °F★
Static pressure (psi★)(1)
Process temperature (°F★)(2)
psi★
°F★
Lower trim
Upper trim
Default values
Differential pressure:
______________________
______________________
0, USL
Static pressure:
______________________
______________________
Atm, USL
Process temperature:
______________________
______________________
LSL, USL
Transmitter sensor calibration:
1.
Options for differential pressure and static pressure: inH2O @ 60 °F, PA (Pascal), Torr, PSI, g/cm2, kPa, inH2O @ 68 °F, inH2O @ 4 °C, bar, mbar, atm, inHg,
ftH2O @ 4 °C, ftH2O @ 60 °C, ftH2O @ 68 °C, mmH2O, mmHg, Kg/cm2, MPa, mmH2O @ 4 °C, cmHg, cmH2O @ 4 °C, kg/m2, mHg, mH2O @ 4 °C, lb/ft2, hPa.
2.
Options for process temperature: °F, °C.
Rosemount 3051SMV
May 2016
Configuration defaults for Rosemount 3051S MultiVariable and Rosemount 3051SF Flowmeters(1)
Compensated mass flow measurement
Direct process variable measurement
Flowmeter type:
3051SF_1
3051SF_2
3051SF_5
3051SF_6
Transmitter type:
3051SMV_M1
3051SMV_M2
3051SMV_P1
3051SMV_P2
Lower sensor limit = –328 °F (–200 °C)
Temperature
configuration:(2)
Lower sensor limit = –328 °F (–200 °C)
Upper sensor limit = 1562 °F (850 °C)
Upper sensor limit = 1562 °F (850 °C)
Mode = Normal
Digital display:
DP, SP, PT, Mass flow
DP, SP, Mass flow
DP, SP, PT
DP, SP
Security switch(2):
Disable
Disable
Simulation switch(2):
Enable
Enable
Atmospheric pressure(1):
14.696 psia
14.696 psia
Low flow cutoff(2):
0.05 inH2O
N/A
SP = Static pressure (gage or absolute), DP = Differential pressure, ST = Sensor module temperature, PT = Process temperature, N/A = Not applicable
1.
For mass flow transmitters with a C2 option and DP Flowmeters, a DP Flow Configuration Data Sheet is also required.
2.
A C2 option is required if settings other than defaults are desired.
C2 option configuration information
Note
The following fields are only required if “M” mass flow option code is selected and apply for a C2 option.
Digital display information(1)
 Differential pressure
 Process temperature
 Gage pressure
 Flow rate(2)
1.
Choose a maximum of four options.
2.
Only available for mass flow transmitters - multivariable type: M on Rosemount 3051SMV.
 Absolute pressure
 Sensor module temperature
Temperature sensor matching
 Pt 100 α = 0.00385 RTD per IEC 751★  Sensor matching α, β, δ
 Sensor matching A, B, C
Fill in Callendar-Van Dusen constants below for sensor matching α, β, δ or A, B, C.
Callendar-Van Dusen constants: _
Process temperature configuration:
R0: __________________________________________
A/α:___________________________________________
B/β: _________________________________________
C/δ: ___________________________________________
Lower sensor limit: _____________ (–328 °F [–200 °C]★)
Upper sensor limit: ________________(1562 °F [850 °C]★)
Variable damping (0–60 seconds)
Differential pressure: ___________________(0.40 sec.★)
Hardware configuration
Security:
 Enable
 Disable★
Simulation:
 Enable★
 Disable
2
Static pressure: _________________ (0.40 sec.★)
Process temperature: ______________ (5.00 sec.★)
Rosemount 3051SMV
May 2016
C2 option flow configuration information
Flow configuration unit of measure
 Grams/second
 Metric tons/second
 Pounds/day
 Normal cubic meters/second
 Standard cubic meters/minute
 Grams/minute
 Metric tons/minute
 Short tons/second
 Normal cubic meters/minute
 Standard cubic meters/hour
 Grams/hour
 Metric tons/hour
 Short tons/minute
 Normal cubic meters/hour
 Standard cubic meters/day
 Kilograms/second  Metric tons/day
 Short tons/hour
 Normal cubic meters/day
 Kilogram/minute
 Pounds/second★
 Short tons/day
 Thousands of Standard cubic feet/day
 Kilogram/hour
 Pounds/minute
 Standard cubic feet/minute  Millions of Standard cubic feet/day
 Kilogram/day
 Pounds/hour
 Standard cubic feet/hour
 Standard cubic meters/second
Flow configuration parameters/settings
Low flow cut-off:
DP = _______________________________ (0.05 inH2O★)
 Normal★
Temperature sensor
mode: ____
 Backup temperature value: ___________________________________________________________
 Fixed temperature value:_______ ______________________________________________________
3
Rosemount 3051SMV
Configuration Data Sheet
00806-0100-4853, Rev AB
May 2016
Global Headquarters
Emerson Process Management
6021 Innovation Blvd.
Shakopee, MN 55379, USA
+1 800 999 9307 or +1 952 906 8888
+1 952 949 7001
[email protected]
North America Regional Office
Emerson Process Management
8200 Market Blvd.
Chanhassen, MN 55317, USA
+1 800 999 9307 or +1 952 906 8888
+1 952 949 7001
[email protected]
Latin America Regional Office
Emerson Process Management
1300 Concord Terrace, Suite 400
Sunrise, FL 33323, USA
+1 954 846 5030
+1 954 846 5121
[email protected]
Europe Regional Office
Emerson Process Management Europe GmbH
Neuhofstrasse 19a P.O. Box 1046
CH 6340 Baar
Switzerland
+41 (0) 41 768 6111
+41 (0) 41 768 6300
[email protected]
Asia Pacific Regional Office
Emerson Process Management Asia Pacific Pte Ltd
1 Pandan Crescent
Singapore 128461
+65 6777 8211
+65 6777 0947
[email protected]
Middle East and Africa Regional Office
Emerson Process Management
Emerson FZE P.O. Box 17033
Jebel Ali Free Zone - South 2
Dubai, United Arab Emirates
+971 4 8118100
+971 4 8865465
[email protected]
Linkedin.com/company/Emerson-Process-Management
Twitter.com/Rosemount_News
Facebook.com/Rosemount
Youtube.com/user/RosemountMeasurement
Google.com/+RosemountMeasurement
Standard Terms and Conditions of Sale can be found at:
www.Emerson.com/en-us/pages/Terms-of-Use.aspx
The Emerson logo is a trademark and service mark of Emerson Electric Co.
MultiVariable, Rosemount, and Rosemount logotype are trademarks of Emerson
Process Management.
FOUNDATION Fieldbus is a trademark of the FieldComm Group.
All other marks are the property of their respective owners.
© 2016 Emerson Process Management. All rights reserved.