Rosemount 3051SMV Configuration Data Sheet May 2016 00806-0100-4853, Rev AB Rosemount™ 3051S MultiVariable™ Configuration Data Sheet with FOUNDATION™ Fieldbus protocol Select only one of the items provided One or more of the listed items can be selected ★ = Default Customer information Customer: ________________________________________________________ Contact name: ____________________________________________________ Phone no: _________________________________________________________ Fax no./email: _____________________________________________________ P.O./reference no.: __________________________________________________ P.O. line item: _____________________________________________________ Model no.: ____________________________________________________________________________________________________________________________ Customer sign-off: ______________________________________________________________________________________________________________________ Tagging Hardware tag: Wire-on _______________________________________________________________________________________ (85 characters, A–Z, 0–9) Nameplate ____________________________________________________________________________________(120 characters, A–Z, 0–9) Software tag: _________________________________________________________________________________________________ (32 characters, A–Z, 0–9) Transmitter information (optional) Descriptor: |__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|(16 characters maximum) |__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|(16 characters) Measurement type Process measurements 1 Differential pressure/static pressure/process temperature 2 Differential pressure/static pressure Based on the measurement type of the transmitter, complete only the necessary process measurements listed in the table above. For example, for measurement type 2 only fill out the differential pressure and static pressure units, LTV, and UTV. Outputs Differential pressure (inH2O @ 68 °F★)(1) Units: inH2O @ 60 °F★ Static pressure (psi★)(1) Process temperature (°F★)(2) psi★ °F★ Lower trim Upper trim Default values Differential pressure: ______________________ ______________________ 0, USL Static pressure: ______________________ ______________________ Atm, USL Process temperature: ______________________ ______________________ LSL, USL Transmitter sensor calibration: 1. Options for differential pressure and static pressure: inH2O @ 60 °F, PA (Pascal), Torr, PSI, g/cm2, kPa, inH2O @ 68 °F, inH2O @ 4 °C, bar, mbar, atm, inHg, ftH2O @ 4 °C, ftH2O @ 60 °C, ftH2O @ 68 °C, mmH2O, mmHg, Kg/cm2, MPa, mmH2O @ 4 °C, cmHg, cmH2O @ 4 °C, kg/m2, mHg, mH2O @ 4 °C, lb/ft2, hPa. 2. Options for process temperature: °F, °C. Rosemount 3051SMV May 2016 Configuration defaults for Rosemount 3051S MultiVariable and Rosemount 3051SF Flowmeters(1) Compensated mass flow measurement Direct process variable measurement Flowmeter type: 3051SF_1 3051SF_2 3051SF_5 3051SF_6 Transmitter type: 3051SMV_M1 3051SMV_M2 3051SMV_P1 3051SMV_P2 Lower sensor limit = –328 °F (–200 °C) Temperature configuration:(2) Lower sensor limit = –328 °F (–200 °C) Upper sensor limit = 1562 °F (850 °C) Upper sensor limit = 1562 °F (850 °C) Mode = Normal Digital display: DP, SP, PT, Mass flow DP, SP, Mass flow DP, SP, PT DP, SP Security switch(2): Disable Disable Simulation switch(2): Enable Enable Atmospheric pressure(1): 14.696 psia 14.696 psia Low flow cutoff(2): 0.05 inH2O N/A SP = Static pressure (gage or absolute), DP = Differential pressure, ST = Sensor module temperature, PT = Process temperature, N/A = Not applicable 1. For mass flow transmitters with a C2 option and DP Flowmeters, a DP Flow Configuration Data Sheet is also required. 2. A C2 option is required if settings other than defaults are desired. C2 option configuration information Note The following fields are only required if “M” mass flow option code is selected and apply for a C2 option. Digital display information(1) Differential pressure Process temperature Gage pressure Flow rate(2) 1. Choose a maximum of four options. 2. Only available for mass flow transmitters - multivariable type: M on Rosemount 3051SMV. Absolute pressure Sensor module temperature Temperature sensor matching Pt 100 α = 0.00385 RTD per IEC 751★ Sensor matching α, β, δ Sensor matching A, B, C Fill in Callendar-Van Dusen constants below for sensor matching α, β, δ or A, B, C. Callendar-Van Dusen constants: _ Process temperature configuration: R0: __________________________________________ A/α:___________________________________________ B/β: _________________________________________ C/δ: ___________________________________________ Lower sensor limit: _____________ (–328 °F [–200 °C]★) Upper sensor limit: ________________(1562 °F [850 °C]★) Variable damping (0–60 seconds) Differential pressure: ___________________(0.40 sec.★) Hardware configuration Security: Enable Disable★ Simulation: Enable★ Disable 2 Static pressure: _________________ (0.40 sec.★) Process temperature: ______________ (5.00 sec.★) Rosemount 3051SMV May 2016 C2 option flow configuration information Flow configuration unit of measure Grams/second Metric tons/second Pounds/day Normal cubic meters/second Standard cubic meters/minute Grams/minute Metric tons/minute Short tons/second Normal cubic meters/minute Standard cubic meters/hour Grams/hour Metric tons/hour Short tons/minute Normal cubic meters/hour Standard cubic meters/day Kilograms/second Metric tons/day Short tons/hour Normal cubic meters/day Kilogram/minute Pounds/second★ Short tons/day Thousands of Standard cubic feet/day Kilogram/hour Pounds/minute Standard cubic feet/minute Millions of Standard cubic feet/day Kilogram/day Pounds/hour Standard cubic feet/hour Standard cubic meters/second Flow configuration parameters/settings Low flow cut-off: DP = _______________________________ (0.05 inH2O★) Normal★ Temperature sensor mode: ____ Backup temperature value: ___________________________________________________________ Fixed temperature value:_______ ______________________________________________________ 3 Rosemount 3051SMV Configuration Data Sheet 00806-0100-4853, Rev AB May 2016 Global Headquarters Emerson Process Management 6021 Innovation Blvd. Shakopee, MN 55379, USA +1 800 999 9307 or +1 952 906 8888 +1 952 949 7001 [email protected] North America Regional Office Emerson Process Management 8200 Market Blvd. Chanhassen, MN 55317, USA +1 800 999 9307 or +1 952 906 8888 +1 952 949 7001 [email protected] Latin America Regional Office Emerson Process Management 1300 Concord Terrace, Suite 400 Sunrise, FL 33323, USA +1 954 846 5030 +1 954 846 5121 [email protected] Europe Regional Office Emerson Process Management Europe GmbH Neuhofstrasse 19a P.O. Box 1046 CH 6340 Baar Switzerland +41 (0) 41 768 6111 +41 (0) 41 768 6300 [email protected] Asia Pacific Regional Office Emerson Process Management Asia Pacific Pte Ltd 1 Pandan Crescent Singapore 128461 +65 6777 8211 +65 6777 0947 [email protected] Middle East and Africa Regional Office Emerson Process Management Emerson FZE P.O. Box 17033 Jebel Ali Free Zone - South 2 Dubai, United Arab Emirates +971 4 8118100 +971 4 8865465 [email protected] Linkedin.com/company/Emerson-Process-Management Twitter.com/Rosemount_News Facebook.com/Rosemount Youtube.com/user/RosemountMeasurement Google.com/+RosemountMeasurement Standard Terms and Conditions of Sale can be found at: www.Emerson.com/en-us/pages/Terms-of-Use.aspx The Emerson logo is a trademark and service mark of Emerson Electric Co. MultiVariable, Rosemount, and Rosemount logotype are trademarks of Emerson Process Management. FOUNDATION Fieldbus is a trademark of the FieldComm Group. All other marks are the property of their respective owners. © 2016 Emerson Process Management. All rights reserved.
© Copyright 2025 Paperzz