GMACS HCl Calibration Standards GMACS (Gas Manufacturer’s Alternative Certified Standards) solutions from Air Liquide fill the regulatory void caused by the absence of EPA Protocol gases for HCl monitoring A New EPA-Approved Class of Calibration Standards for CEMS Installations Air Liquide America Specialty Gases LLC GMACS (Gas Manufacturer’s Alternative Certified Standards) solutions from Air Liquide fill the regulatory void caused by the absence of EPA Protocol gases for hydrogen chloride monitoring, providing accurate calibration standards for CEMS commissioning and QA—available now to meet impending PC MACT compliance date (September 2016). Introducing a New EPA-Approved Class of Calibration Standards for CEMS Installations Identifying a growing need for calibration standards in order to comply with pending EPA regulations governing the monitoring of hydrogen chloride, Air Liquide petitioned the EPA to approve a new class of calibration gases named GMACS by the EPA. Acknowledging “the critical need for HCl calibration standards that are not available due to the absence of national or international reference materials to which protocols must be analytically and statistically traceable,” the EPA approved the use of HCl GMACS products to calibrate HCl analyzers*. Benefits and Features n n n n n Scott™ brand GMACS are especially effective when used in conjunction with our new proprietary gas delivery panel complemented by our nitrogen purge and purification panel. Both panels were developed specifically for use with HCl gas mixtures. GMACS are engineered calibration gases for stationary sources that are subject to compliance under the following EPA regulations: 40 CFR Part 63 Subpart LLL (Portland Cement MACT) 40 CFR Part 63 Subpart UUUUU (Utility MACT) 40 CFR Part 63 Subpart DDDDD 40 CFR Part 60 Subparts CCCC and DDDD * The complete EPA OAQPS approval letter may be viewed on our website at https://industry.airliquide.us/gmacs. n RAVSTAT™ blending assures G accurate NIST-traceable HCl addition Confirming analysis shows full recovery/no loss of HCl EPA-approved statistics calculate product uncertainties at ±4% Dual-certification interlocking blend and analysis concentrations for added calibration accuracy Exclusive ACULIFE™ cylinder inerting treatments ensure long-term stability of cylinder contents Exclusive delivery system ensures moisture-free delivery and rapid mixture stabilization times, ensuring significantly reduced gas consumption Specially treated cylinder valves protect against corrosion GMACS Certification Scheme For primary calibration of CEMS HCl monitors at stationary sources. Raw Materials N2 (UHP) HCI (ESG) Purity 99.9999% 99.9996% Mass Uncertainty < 0.0001% < 0.0004% N2 HCl HIGH-PURITY SUPPLY ELECTRONIC PURITY Mixtures Certified by GRAVSTAT™ Blending Classical Analysis Instrumental Analysis Interlock Uncertainty Intermediate Blending Standards Certified Value Uncertainty Range Reference Standard HCI Gravimetric BLENDING STANDARD 0.1–0.6% NIST Weights Gas Manufacturer's Primary Standards (GMPS) Certified Value Gravimetric Classical 0.1–0.6% 1.0–2.5% Reference Standard NIST Weights SPEX Solns Certified Value Gravimetric Instrumental 0.1–0.6% 1.2–3.0% NIST Weights GMPS Stds Uncertainty Range GMPS REFERENCE STANDARD 1.0–2.5% Gas Manufacturer's Alternative Certified Standards (GMACS) Uncertainty Range Reference Standard GMACS 1.5–4.0% PRODUCT CYLINDER Gas Specifications Scott™ brand GMACS are used for the primary calibration of CEMS HCl monitors at stationary sources. Certified daily calibration standards are for regular QA and periodic RATA testing of HCl CEMS. Dual-Certified Standards GMACS Single-Certified Standards Certified Daily Cylinder Size Blend Tolerance Analytical Accuracy Blend Tolerance Analytical Accuracy CGA Shelf Life 1 ppm – 1% HCl 30AL 47AL ±10% ±4% ±10% ±5% 330 1 year 1 ppm – 1% HCl with SF6 or N2O Tracer* 30AL 47AL ±10% ±4% ±10% ±5% 330 1 year Available Concentrations in balance Nitrogen * Please specify trace concentration. EPA Protocols and Other Gases 1 Scott brand EPA Protocols are the recognized standard for calibration excellence and feature dual-certification and NIST-traceability. They are available for measuring NO, NO2, SO2, C3H8 and other applications with a shelf life that varies by product. Spike gas for CEMS validation (standard additions) tests is available as well as other products for purge and zero applications. Gas Handling Equipment Turnkey HCl delivery solutions assure safe and accurate delivery of gases n n n n 2 Specially treated components and 3-station panels available with bypass flow (Fig 2) 1 HCl-specific low internal volume regulator Exclusive valve purge/clean procedure Other available equipment n N purge and purification panel (Fig 1) 2 n High-purity plated and stainless steel pressure regulators n Specially treated regulators and purge assemblies n Safety equipment and gas detectors n Cylinder storage and handling equipment n i-SEE™ on-site safety and operational best practice surveys Air Liquide America Specialty Gases LLC 9811 Katy Freeway Suite 100 Houston TX 77024 World leader in gases, technologies and services for Industry and Health, Air Liquide is present in 80 countries with close to 50,000 employees and serves more than 2 million customers and patients. NOTE: This brochure is intended for general information purposes only and is not intended as a representation or warranty of any kind, or as a statement of any terms or condition of sale. The information herein is believed to be correct, but is not warranted for correctness or completeness or for applicability to any particular customer or situation. ACULIFE, GRAVSTAT, i-SEE and Scott are trademarks of Air Liquide Group. ©2016 Air Liquide America Specialty Gases LLC Phone: 800.217.2688 Fax: 215.766.2476 Email: [email protected] industry.airliquide.us All rights reserved 05/2016-MSD-500 1174
© Copyright 2026 Paperzz