GEA Air Filtration – Over 2000 Filter Media The prime

GEA Air Filtration – Over 2000 Filter Media
The prime choice in highest air quality
GEA Air Filters
a~í~=C=c~Åíë
ÉåÖáåÉÉêáåÖ=Ñçê=~=ÄÉííÉê=ïçêäÇ
db^=eÉ~í=bñÅÜ~åÖÉêë
Table of Contents
GEA Air Filters
Filter Mats, Rolls, Special-Dimension Elements
and Roll-Band Filters ........................................................................ 4
Filter Mats CTM ......................................................................................................... 4
FIBROIDELASTIC ..................................................................................................... 5
FIBROIDELASTOV ................................................................................................... 6
VENUFA 290 ............................................................................................................. 7
MY-STOP 500 ........................................................................................................... 8
ACELAN .................................................................................................................... 9
PERFEKT ................................................................................................................ 10
FARBGLAS 2" ......................................................................................................... 11
FIBROBAND ........................................................................................................... 12
Filter Band 402/411/412 .......................................................................................... 13
Filter Plates ...................................................................................... 14
GAL ......................................................................................................................... 14
HL 12,5 .................................................................................................................... 15
VISCINOL A30 ........................................................................................................ 16
Filter cells ........................................................................................ 17
FILTERGLAS .......................................................................................................... 17
ULTRANGLAS ........................................................................................................ 18
Z-50/Z-100 ............................................................................................................... 19
FIBERGLAS ............................................................................................................ 20
Bag Filter ......................................................................................... 21
MULTISACK Overview ............................................................................................ 21
MULTISACK K35/K50 ............................................................................................. 22
MULTISACK K55/K65 ............................................................................................. 23
MULTISACK K85/K95 ............................................................................................. 24
MULTISACK G55/G65 ............................................................................................ 25
MULTISACK G85/G95 ............................................................................................ 26
Filter Elements ................................................................................ 28
MULTIFORM Overview ........................................................................................... 28
MULTIFORM MF65/MF85/MF90 ............................................................................ 29
MULTIFORM-Eco MFEC55 /MFEC65/MFEC85 ..................................................... 30
MULTIFORM MF95/MF98/MF99 ............................................................................ 31
MULTIFORM MF100/101 ........................................................................................ 32
MULTITHERM Overview ......................................................................................... 33
MULTITHERM MT60/MT90 .................................................................................... 34
MULTIPLAN type code ............................................................................................ 36
MULTIPLAN I (MP65, 85, 95) ................................................................................. 37
MULTIPLAN II (MP55, 65, 85, 95) .......................................................................... 38
MULTI 2004 ............................................................................................................. 39
MULTI 2004 Holding Frame .................................................................................... 40
MULTICOL .............................................................................................................. 41
2
PR-2009-0099-GB • Subject to modifications • Status K12-02/2013
Table of Contents
GEA Air Filters
HEPA filters ..................................................................................... 43
Overview .................................................................................................................. 43
Description of Product Type Code ........................................................................... 44
E11 Panel Filter ....................................................................................................... 46
E11 V-Shape ............................................................................................................ 47
H13 with Aluminium Separators ............................................................................... 47
H13 Panel Filter ....................................................................................................... 47
E11 V-Shape/H13 V-Shape ..................................................................................... 49
H14/U15 ................................................................................................................... 50
Activated Carbon Filter .................................................................. 51
Activated Carbon, Loose .......................................................................................... 51
Activated Carbon Plate Element AK-20 ................................................................... 51
Activated Carbon Cartridge 705/706/707 ................................................................. 52
Activated Carbon Cartridge 708/709 ........................................................................ 53
CKG holding frame .................................................................................................. 54
Round Air Filters ............................................................................. 55
Overview .................................................................................................................. 55
DAH ......................................................................................................................... 56
DBH/DBA/DBV ......................................................................................................... 57
DAC/DBC ................................................................................................................. 60
Glove Box Filter .............................................................................. 63
DKA/DKB ................................................................................................................. 63
DKC/DKD ................................................................................................................. 64
CDD Wall Frame ...................................................................................................... 65
Filter Frames for Wall or Ceiling Installation ................................ 65
CGF Ceiling Air Outlets ............................................................................................ 66
CKC Wall Frame ...................................................................................................... 67
ELA Filter Casing ..................................................................................................... 68
EBE Casing .............................................................................................................. 69
Notes ................................................................................................ 70
Copyright note
Disclosing, copying, distributing or taking any action in reliance on the contents of this
document is strictly prohibited without express prior consent. Violations entail liability
for any damages or other liability arising. All rights in relation to patents, utility patents
or design patents are reserved.
PR-2009-0099-GB • Subject to modifications • Status K12-02/2013
3
Filter Mats, Rolls, Special-Dimension Elements and Roll-Band Filters
GEA Air Filters
Filter Mats CTM
CTM filter mats consist of polyester fibres
with pronounced labyrinth structure and with progressive depth structure.
Application example:
pre-filter for small air handling systems with high dust concentration and for coarse
dust filtration in standard air handling units
Special features:
elastic, without wetting agent and regenerable
Areas of application:
standard ventilation and air handling units, climate control facilities, cabinet air handling units, cooling of switch boxes,
heat exchangers, recirculating-air units, unit heaters, cooling of large machines and
switchgear as well as paint spray compartments
Pressure drop [Pa]
Pressure drop diagram:
Air flow rate [m³/hm²]
Specifications:
CTM
Filter class
CTM-50
CTM-60
CTM-90
G2
G3
G4
5
10
20
5400
5400
5400
[EN 779]
Installation depth/thickness [mm]
Form of delivery/
order numbers:
Nominal air flow rate
[m³/hm²]
Initial pressure drop
[Pa]
11
18
50
Maximum allowed pressure
[Pa]
drop
250
250
250
Mean filtration efficiency
[%]
72.0
81.4
91.7
Dust holding capacity
[g/m²]
Fire behaviour
[DIN 53438]
425
590
518
F1/K1
F1/K1
F1/K1
Max. operating temperature [°C]
80
80
80
Max. rel. air humidity
100
100
100
CTM
[%]
Size
Order number
Special-dimension elements
CTM-50
0 to 40 m², maximum width 2 m
X-CTM-50
CTM-60
0 to 40 m², maximum width 2 m
X-CTM-60
CTM-90
0 to 40 m², maximum width 2 m
X-CTM-90
Rolls
4
CTM-50
2 x 40 m, packaging unit 1
40 61 031
CTM-60
2 x 20 m, packaging unit 1
40 72 531
CTM-90
2 x 20 m, packaging unit 1
40 72 831
PR-2009-0099-GB • Subject to modifications • Status K12-02/2013
Filter Mats, Rolls, Special-Dimension Elements and Roll-Band Filters
GEA Air Filters
FIBROIDELASTIC
FIBROIDELASTIC filter mats consist of latex-bonded, randomly structured natural
mixed fibres with uniform depth structure and great intrinsic stiffness, the mats are
elastic, not provided with a wetting agent, and repeatedly regenerable
Application example:
primarily used with high dust concentration and filtration of especially coarse dust
Special features:
very efficient thanks to extremely low initial pressure drop, with high air flow rate as
well; very high dust holding capacity
Areas of application:
climate control facilities and air handling units in the cement industry or similar areas,
intake and combustion air for fans, compressors, internal-combustion engines and
pneumatic conveyor systems
Pressure drop [Pa]
Pressure drop diagram:
Air flow rate [m³/hm²]
Specifications:
FIBROIDELASTIC
Filter class
[EN 779]
Installation depth/thickness [mm]
Form of delivery/
order numbers:
TIC-20
TIC-30
TIC-40
G2
G2
G3
20
30
40
10000
10000
10000
Nominal air flow rate
[m³/hm²]
Initial pressure drop
[Pa]
65
75
95
Maximum allowed pressure
[Pa]
drop
250
250
250
Mean filtration efficiency
[%]
73.1
77.1
84.6
Dust holding capacity
[g/m²]
Fire behaviour
[DIN 53438]
920
933
1064
F1/K1
F1/K1
F1/K1
Max. operating temperature [°C]
60
60
60
Max. rel. air humidity
100
100
100
FIBROIDELASTIC
[%]
Size
Order number
Special-dimension elements
TIC-20
0 to 2 m², maximum width 1 m
X-TIC-20
TIC-30
0 to 2 m², maximum width 1 m
X-TIC-30
TIC-40
0 to 2 m², maximum width 1 m
X-TIC-40
Plate
TIC-20
1 x 2 m, packaging unit 1
16 08 481
TIC-30
1 x 2 m, packaging unit 1
16 08 881
TIC-40
1 x 2 m, packaging unit 1
16 09 281
PR-2009-0099-GB • Subject to modifications • Status K12-02/2013
5
Filter Mats, Rolls, Special-Dimension Elements and Roll-Band Filters
GEA Air Filters
FIBROIDELASTOV
FIBROIDELASTOV filter mats consist of robust fleece made of randomly structured
polyester fibres with progressive depth structure, the filter layer, not provided with a
wetting agent, is elastic and regenerable.
Application example:
reliable filtration of coarse dust in climate control and air handling systems
Special features:
very efficient thanks to extremely low initial pressure drop, with high air flow rate as
well; very high dust holding capacity
Areas of application:
general purpose climate control facilities and air handling units, protection against contamination of large machines and switchgear, air intake and combustion air for fans,
compressors, internal-combustion motors
200
Pressure drop diagram:
Pressure drop [Pa]
TOV-40
160
120
80
40
0
Specifications:
0
2500 5000 7500 10000
Air flow rate [m³/hm²]
FIBROIDELASTOV
TOV-40
Filter class
[EN 779]
G4
Installation depth/thickness [mm]
Form of delivery/
order numbers:
Nominal air flow rate
[m³/hm²]
Initial pressure drop
[Pa]
40
2500-10,000
26-185
Maximum allowed pressure
[Pa]
drop
250
Mean filtration efficiency
[%]
93,0
Dust holding capacity
[g/m²]
Fire behaviour
[DIN 53438]
477
F1/K1
Max. operating temperature [°C]
70
Max. rel. air humidity
100
FIBROIDELASTOV
[%]
Size
Order number
Special-dimension elements
TOV-40
0 to 2 m², maximum width 1 m
X-TOV-40
1 x 1.5 m, packaging unit 5
16 08 021
Plate
TOV-40
6
PR-2009-0099-GB • Subject to modifications • Status K12-02/2013
Filter Mats, Rolls, Special-Dimension Elements and Roll-Band Filters
GEA Air Filters
VENUFA 290
VENUFA 290 filter mats consist of polyester fibres with progressive depth structure
Application example:
filtration of dust particles in air handling systems
Special feature:
progressively constructed, without wetting agent and regenerable; meets F1/K1 fire
protection class; maximum continuous operating temperature 80 °C
Areas of application:
climate control and cabinet air handling units, decentral HVAC units, pre-fan and preheat exchanger units
Pressure drop [Pa]
Pressure drop diagram:
Air flow rate [m³/h]
Specifications:
Form of delivery/
order numbers:
VENUFA 290
VEN 290
Filter class
[EN 779]
G3
Installation depth/thickness
[mm]
20
Nominal air flow rate
[m³/hm²]
Initial pressure drop
[Pa]
31
Maximum allowed pressure
drop
[Pa]
250
Mean Filtration efficiency
[%]
87.7
Dust holding capacity
[g/m²]
Fire behaviour
[DIN 53438]
Max. operating temperature
[°C]
80
Max. rel. air humidity
[%]
100
VENUFA 290
Size
5400
572
F1/K1
Order number
Special-dimension elements
VEN 290
0 to 40 m², maximum width 2 m
X-VEN-290
Rolls
VEN 290
2 x 20 m, packaging unit 1
PR-2009-0099-GB • Subject to modifications • Status K12-02/2013
40 72 631
7
Filter Mats, Rolls, Special-Dimension Elements and Roll-Band Filters
GEA Air Filters
MY-STOP 500
MY-STOP 500 filter mats consist of polyester fibres that have been spun to produce a
very robust fleece with progressive structure, the especially smoothed pure-air side
prevents migration of fibres and assures great dust-storage capacity
Application example:
reliable filtration of coarse dust in climate control and air handling units
Special features:
elastic, without wetting agent and regenerable, with progressive structure
Areas of application:
standard ventilation and air handling units, supply air units, units for cooling large
machines and switchgear, first filter stage for filtration of coarse dust, pre-filter for paint
spray compartments and painting installations
Pressure drop [Pa]
Pressure drop diagram:
Air flow rate [m³/hm²]
Specifications:
Form of delivery/
order numbers:
MY-STOP 500
MY-500
Filter class
[EN 779]
G4
Installation depth/thickness
[mm]
20
Nominal air flow rate
[m³/hm²]
Initial pressure drop
[Pa]
40
Maximum allowed pressure
drop
[Pa]
250
Mean filtration efficiency
[%]
94.4
Dust holding capacity
[g/m²]
Fire behaviour
[DIN 53438]
Max. operating temperature
[°C]
80
Max. rel. air humidity
[%]
100
MY-STOP 500
5400
700
Size
F1/K1
Order number
Special-dimension elements
MY-500
0 to 40 m², maximum width 2 m
X-MY-500
2 x 20 m, packaging unit 1
40 72 731
Rolls
MY-500
8
PR-2009-0099-GB • Subject to modifications • Status K12-02/2013
Filter Mats, Rolls, Special-Dimension Elements and Roll-Band Filters
GEA Air Filters
ACELAN
ACELAN filter mats consist of thermally bonded polyester fibres, the elastic medium is
not provided with a wetting agent, is progressive, and is constructed with compression
on the pure-air side.
Application example:
filtration of fine dust in climate control and air handling systems
Special features:
without wetting agent and with progressive structure, meets standards for filter class
F5
Areas of application:
filtration of supply air of sensitive switchgear, water treatment facilities, pre-filter for
paint spray compartments and painting installations, standard climate control and air
handling units
600
Pressure drop [Pa]
Pressure drop diagram:
ACELAN
450
300
150
0,1
0,2
0,3
0,4
Air Flow Volume flow [m²/s]
Specifications:
Form of delivery/
order numbers:
ACELAN
ACELAN
Filter class
[EN 779]
M5
Installation depth/thickness
[mm]
30
Nominal air flow rate
[m2/s]
0.250
Initial pressure drop
[Pa]
35
Maximum allowed pressure
drop
[Pa]
450
Mean filtration efficiency
[%]
97
Mean Efficiency
[%]
51
Dust holding capacity
[g/m²]
211
Fire behaviour
[DIN 53438]
Max. operating temperature
[°C]
80
Max. rel. air humidity
[%]
100
ACELAN
Size
F1/K1
Order number
Special-dimension elements
ACELAN
0 to 20 m², maximum width 2 m
X-ACELAN
Rolls
ACELAN
2 x 20 m, packaging unit 1
PR-2009-0099-GB • Subject to modifications • Status K12-02/2013
26 02 850
9
Filter Mats, Rolls, Special-Dimension Elements and Roll-Band Filters
GEA Air Filters
PERFEKT
PERFEKT 300 filter mats consist of superfine, thermally bonded polyester fibres not
provided with a wetting agent, with progressive structure, and with compression on the
pure-air side. PERFEKT-600 filter mats are wetted with a bond-active agent, and their
pure-air side is reinforced with a lattice structured fabric.
Application example:
for air handling units with very high standards in air purity
Special feature:
meets standards of filter class M5
Areas of applications:
standard climate control and air handling systems, supply air for paint spray compartments and paint installations
PERFEKT 600 filter mats are certified by Eurovent
AIR FILTERS
CLASS F5-F9
Pressure drop diagram:
Pressure drop [Pa]
70
60
PF-600
50
40
30
PF-300
20
10
0
Specifications:
Form of delivery/
order numbers:
0
500
1000 1500
Air flow rate [m³/hm²]
2000
PERFEKT
PERFEKT 300
PERFEKT 600
Filter class
[EN 779]
M5
M5
Installation depth/thickness
[mm]
15
20
Nominal air flow rate
[m³/hm²]
900
900
Initial pressure drop
[Pa]
20
27
Maximum allowed pressure drop [Pa]
450
450
Mean filtration efficiency
[%]
96.4
97.9
Mean Efficiency
[%]
53.3
56.6
Dust holding capacity
[g/m²]
342
387
Fire behaviour
[DIN 53438]
F1/K1
F1/K1
Max. operating temperature [°C]
80
80
Max. rel. air humidity
100
100
PERFEKT
[%]
Size
Order number
Special-dimension elements
PERFEKT 300
0 to 40 m², maximum width 2 m
X-PF-300
PERFEKT 600
0 to 40 m², maximum width 2 m
X-PF-600
PERFEKT 300
2 x 20 m, packaging unit 1
40 72 931
PERFEKT 600
2 x 20 m, packaging unit 1
40 73 131
Rolls
10
PR-2009-0099-GB • Subject to modifications • Status K12-02/2013
Filter Mats, Rolls, Special-Dimension Elements and Roll-Band Filters
GEA Air Filters
FARBGLAS 2"
FARBGLAS 2" filter mats consists of a spun glass-fibre fabric with compression on the
pure-air side, the glass-fibre medium has no wetting agent and is odourless, noninflammable, and insensitive to moisture in the air
Application example:
filtration of paint mist in paint spray compartments and paint facilities
Special features:
progressively constructed, maximum continuous operating temperature 120 °C
Special features:
standard climate control and air handling systems, paint spray compartments and paint
installations, HVAC equipment
Pressure drop [Pa]
Pressure drop diagram:
Air flow rate [m³/hm²]
Specifications:
FARBGLAS 2"
FAGL-2
Installation depth/thickness
[mm]
Nominal air flow rate
[m³/hm²]
50
Initial pressure drop
[Pa]
7-40
Maximum allowed pressure
drop
[Pa]
80
Mean filtration efficiency
[%]
97.0 *
Dust holding capacity
[g/m²]
2500-6,300
–
Fire behaviour
[DIN 53438]
Max. operating temperature
[°C]
F1/K1
120
Max. rel. air humidity
[%]
100
* mean degree of filtration with respect to paint mist
Form of delivery/
order numbers:
FARBGLAS 2"
Size
Order number
Special-dimension elements
FARBGLAS 2"
0 to 40 m², maximum width 2 m
X-FAGL-2
2 x 20 m, packaging unit 1
40 60 831
Rolls
FARBGLAS 2"
PR-2009-0099-GB • Subject to modifications • Status K12-02/2013
11
Filter Mats, Rolls, Special-Dimension Elements and Roll-Band Filters
GEA Air Filters
FIBROBAND
FIBROBAND filter bands consist of fine, randomly structured polyester fibres, the filter
layer is constructed on a stiff, tear-resistant polyester gauze which is mounted on a
cardboard spool with insertion sleeve for the DELBAG system
Application example:
filtration of coarse and fine dust in large air-flow volumes, in particular in roll-band filter
systems
Special features:
cardboard spool with an insertion sleeve; to be used in filter-band Delbag systems
Areas of application:
climate control facilities and air handling units with great air-flow volumes
Pressure drop [Pa]
Pressure drop diagram:
Air flow rate [m³/hm²]
Specifications:
Form of delivery/
order numbers:
12
FIBROBAND
FIBROBAND
Filter class
[EN 779]
G3
Installation depth/thickness
[mm]
10
Nominal air flow rate
[m³/hm²]
Initial pressure drop
[Pa]
40
Maximum allowed pressure
drop
[Pa]
250
Mean filtration efficiency
[%]
88,1
Dust holding capacity
[g/m²]
Fire behaviour
[DIN 53438]
Max. operating temperature
[°C]
80
Max. rel. air humidity
[%]
100
FIBROBAND
5700
398
Size
F1/K1
Order number
Cardboard spool with insertion sleeve for DELBAG system, packaging unit 1
Size 1
0.81 m x 20 m. weight/unit 6.2 kg
40 09 021
Size 2
1.11 m x 20 m . weight/unit 8.3 kg
40 09 121
Size 3
1.41 m x 20 m . weight/unit 10.4 kg
40 09 221
Size 4
1.71 m x 20 m. weight/unit 12.5 kg
40 09 321
Size 5
2.01 m x 20 m . weight/unit 14.6 kg
40 09 521
PR-2009-0099-GB • Subject to modifications • Status K12-02/2013
Filter Mats, Rolls, Special-Dimension Elements and Roll-Band Filters
GEA Air Filters
Filter Band 402/411/412
402/411/412 filter bands consist of glass fibres with progressive structure.
The filter bands are wetted with an antibacterial and water-proof dust-trapping agent
which enables to achieve very high dust-holding capacity. The filter bands are suitable
for three different mounting systems:
– 402 for CEAG/AAF system
– 411 for SCHIRP system
– 412 for DELBAG system
Application example:
filtration of coarse and fine dust in large air-flow volumes, in particular in roll-band filter
systems
Special features:
When placing your order please consider three different mounting systems!
– 402 steel spool with side window
– 411 cardboard spool
– 412 cardboard spool with insertion sleeve
Areas of application:
climate control facilities and air handling units with great air-flow volumes
Specifications:
Filter bands
Filter class
402
411
412
G4
G4
G4
50
50
50
10800
10800
10800
40
50
50
150-180
150-180
150-180
[EN 779]
Installation depth/thickness [mm]
Nominal air flow rate
[m³/hm²]
Initial pressure drop
[Pa]
Maximum allowed pressure
[Pa]
drop
Form of delivery/
order numbers:
Mean Filtration efficiency
[%]
Fire behaviour
[DIN 53438]
91.0
91.0
91.0
F1/K1
F1/K1
F1/K1
Max. operating temperature [°C]
65
65
65
Max. rel. air humidity
[%]
100
100
100
Filter bands
Width [mm]
Weight [kg]
Order number
402, steel spool with side window, roll à 20 m, packaging unit 1
402-3
832
11.0
40 52 031
402-4
1137
12.4
40 52 131
402-5
1442
16.8
40 52 231
402-6
1747
21.7
40 52 331
402-7
2052
27.6
40 52 431
8.3
40 51 031
402, cardboard spool, roll à 20 m, packaging unit 1
411-3
832
411-4
1137
9.9
40 51 131
411-5
1442
12.0
40 51 231
411-6
1747
13.8
40 51 331
411-7
2052
19.0
40 51 431
412, steel spool with insertion sleeve, roll à 21 m, packaging unit 1
412-1
810
10.0
40 51 531
412-2
1110
14.8
40 51 631
412-3
1410
18.5
40 51 731
412-4
1710
21.0
40 51 831
412-5
2010
26.5
40 51 931
PR-2009-0099-GB • Subject to modifications • Status K12-02/2013
13
Filter Plates
GEA Air Filters
GAL
GAL filter plates – several layers of aluminium or stainless-steel woven wire mesh are
installed between metal support plates made of expanded metal mesh on two sides,
and are framed by a sturdy U-shaped profile frame made of aluminium or stainless
steel, the filter cells are regenerable.
Application example:
Pre-filter elements for filtration of highly concentrated dust and oil and emulsion mist
Special features:
High maximum operating temperature (400 °C); high dust-holding capacity
Areas of application:
Steel and metallurgical industry in highly dust-laden and harsh conditions, power stations, off-shore facilities, air treatment facilities in arid and tropical regions, filtration of
mist in cooling and lubrication processes with metal cutting and non-cutting tools, engineering, tools and vehicle industries, rolling mills
Pressure drop [Pa]
Pressure drop diagram:
Air flow rate [m³/hm²]
Specifications:
GAL
GAL-N
Filter class
[EN 779]
G3
G3
Installation depth/thickness
[mm]
48
48
Nominal air flow rate
[m³/hm²]
6850
10400
Initial pressure drop
[Pa]
84
86
Maximum allowed pressure
[Pa]
drop
500
500
Mean Filtration efficiency
[%]
87.0
86.0
Dust holding capacity
[g/m²]
400
400
400
400
Aluminium
Stainless steel
Max. operating temperature [°C]
Casing material
Form of delivery/
order numbers:
GAL-A
GAL
Size W/H/D
[mm]
Air flow rate
[m³/h]
Approx. weight
[kg]
Order
number
Filter plate, packaging unit 1
14
GAL aluminium
287/287/48
600
1.3
00 02 592
GAL aluminium
287/592/48
1200
1.5
00 02 591
GAL aluminium
592/592/48
2400
2.9
60 04 481
GAL stainless
steel
287/592/48
1800
3.1
00 39 401
GAL stainless
steel
592/592/48
3600
5.6
60 04 581
PR-2009-0099-GB • Subject to modifications • Status K12-02/2013
Filter Plates
GEA Air Filters
HL 12,5
HL 12.5 filter plates consist of several layers of bonded expanded metal mesh, which
is effective for separation of coarse dust due to the labyrinth structure of the plates; the
filter plates are wetted with a dust-trapping agent (VISCINOL), and are regenerable.
Application example:
filtration of coarse dust in climate control and air handling units
Special features:
high dust-holding capacity resulting in extended service life; use with 2 or 3 plates
Areas of application:
Steel and metallurgical industry, roll mills, power stations, engineering, tools and vehicle industries, machine-room ventilation, filtration of mist in cooling and lubrication
processes with metal cutting and non-cutting tools, filtration of wax mist in car-making
industry and automated welding facilities, spark protection
Pressure drop diagram:
Pressure drop [Pa]
triple-plate
double plate
Air flow rate [m³/hm²]
Specifications:
HL 12,5
double plate
triple-plate
Filter class
[EN 779]
G3
G4
Installation depth/thickness
[mm]
2/12.5
3/12.5
Nominal air flow rate
[m³/hm²]
7200
7200
Initial pressure drop
[Pa]
70
100
Maximum allowed pressure
[Pa]
drop
500
500
Mean Filtration efficiency
[%]
86.0
91.0
Dust holding capacity
[g/m²]
450
494
Max. operating temperature [°C]
45 *
45 *
Max. rel. air humidity
100
100
[%]
* depending on wetting agent
Form of delivery/
order numbers:
HL 12,5
Size W/H [mm]
Approx. weight [kg]
Order number
Filter plate, packaging unit 1
surface sendizimir galvanized
surface galvanized
aluminium
494/494 with key hole
2.5
2.5
0.8
60 01 021
60 02 281
60 01 521
surface sendizimir galvanized
surface galvanized
aluminium
494/494 with handle
2.5
2.5
0.8
60 01 121
00 00 098
60 01 681
Aluminium
494/988 with key hole
2.0
60 01 881
PR-2009-0099-GB • Subject to modifications • Status K12-02/2013
15
Filter Plates
GEA Air Filters
VISCINOL A30
The filter plates HL 12.5 and high efficiency round air filters HL are wetted with the
VISCINOL dust-trapping agent; depending on the application area - different VISCINOL types are available; in dust-trapping agent is supplied in containers, 20 liters each
Application example:
wetting metal filter elements
Special features:
mixture of higher hydrocarbons
Areas of application:
filter plates HL 12.5 and round air filter of type DBH and DAH
Chemical composition
Mixture of higher hydrocarbons, with addition of active and colouring agents, siliconebased defoamer
Safety precautions
Given that the conventional precaution measures during handling of mineral oil products are adhered to and instruction on personal protection equipment and toxicological
information is taken into account - no special warnings are so far known.
First Aid remedies
Upon skin contact
Upon eye contact
Suitable extinguishing
agents
Particularly high risk
Measures on environmental
protection
Form
Colour
Density at 15 °C
Viscosity at 40 °C
Primary irritation effect
Conditions to be avoided
Substances to be avoided
Instructions on disposal
Labelling according to
EC standards
Form of delivery/
order numbers:
Rinse with fresh water and soap at once. If skin irritation persists - search professional
medical help, rinse with plenty of fresh water and seek professional medial treatment.
Foam, extinguishing powder, carbon dioxide
Combustion products NOx, CO, S02, soot and other organic substances.
Do not inhale smoke fumes.
Prevent from entering into the sewage system, surface and ground water. Prevent from
entering into soil. Prevent area-like expansion. In case of leakage - inform the relevant
authority.
Liquid
Red
899-910kg/m³
64-72 mm²/s
Not classified as irritating, continuous contact can cause irritation
Higher temperatures (beginning decomposition)
Strong oxidizing agents
Consider regulations on waste management. Only mixing with old oil is allowed
(2/sentence 1 of the German waste oil legislation).
not subject to mandatory labelling
VISCINOL
VISCINOL A-30 20 liter
16
Temperature range [°C]
Approx. weight [kg]
Order number
0.9
20 00 365
Container – minimum purchase quantity 20 l
-15 to +45
PR-2009-0099-GB • Subject to modifications • Status K12-02/2013
Filter cells
GEA Air Filters
FILTERGLAS
FILTERGLAS cells consist of tightly intermeshed glass fibres with special closure
fleece on the pure-air side, on two sides, the filter cell is framed with large-perforation
metal support plates in a moisture-resistant carton frame enclosure with a crimp fold.
Application example:
filtration of coarse dust in climate control and air handling systems
Special features:
special closure fleece that prevents migration of glass fibres
Areas of application:
standard climate control facilities and air handling units, pharmaceutical industry, prefilters for paint finishing line and paint spray compartment
Pressure drop diagram:
Pressure drop [Pa]
Curve applies to size 480 mm x 480 mm
Air flow rate [m³/h]
Specifications:
Form of delivery/
order numbers:
FILTERGLAS
FILTERGLAS
Filter class
[EN779]
G4
Installation depth/thickness
[mm]
14
Nominal air flow rate
[m³/h]
1000
Initial pressure drop
[Pa]
140
Maximum allowed pressure
drop
[Pa]
500
Mean Filtration efficiency
[%]
96.0
Max. operating temperature
[°C]
80
Max. rel. air humidity
[%]
100
FILTERGLAS
Size W/H [mm]
Weight/unit [kg]
Order number
0.3
40 03 821
Filter cell, packaging unit 25
FILTERGLAS
PR-2009-0099-GB • Subject to modifications • Status K12-02/2013
480/480
17
Filter cells
GEA Air Filters
ULTRANGLAS
ULTRANGLAS/ULTRANGLAS-H filter cells consist of tightly intermeshed glass
fibres.ULTRANGLAS is framed on two sides in a moisture-resistant carton frame with
large perforation in the metal support plates.ULTRANGLAS / -H is framed on all sides
in expanded aluminium mesh and is designed for operating temperatures up to 300°C.
Application example:
filtration of coarse dust in climate control and air handling units
Special feature:
ULTRANGLAS-H meets F1/K1 fire protection class; maximum continuous operating
temperature of 300 °C
Areas of application:
standard climate control facilities and air handling units, industrial drying facilities, prefilters for paint finishing lines and paint spray compartments
Pressure drop diagram:
Pressure drop [Pa]
Curve applies to size 480 mm x 480 mm and
U-Glass H
Curve applies to size 480 mm x 480 mm and
U-Glass H
Air flow rate [m³/h]
Specifications:
ULTRANGLAS
U-GLAS
U-GLAS H
Filter class
[EN 779]
G4
G4
Installation depth/thickness
[mm]
48
14
Nominal air flow rate
[m³/h]
1500
1500
Initial pressure drop
[Pa]
130
170
Maximum allowed pressure
[Pa]
drop
500
500
Mean Filtration efficiency
[%]
93.0
93.0
Fire behaviour
[DIN 53438]
–
F1/K1
Max. operating temperature [°C]
80
300
Max. rel. air humidity
100
100
[%]
* depending on wetting agent
Form of delivery/
order numbers:
18
ULTRANGLAS
Size W/H [mm]
Packaging unit
Weight/unit [kg]
Order number
U-GLAS
490/490
10
0.7
40 04 221
U-GLAS H
480/480
30
0.3
60 35 921
Filter plate
PR-2009-0099-GB • Subject to modifications • Status K12-02/2013
Filter cells
GEA Air Filters
Z-50/Z-100
Z-50/Z-100 air-filter cells consist of pleated synthetic fleece in a sturdy, water-repellent, impregnated carton frame with supporting lattices on the dust and pure-air sides;
the filter medium is folded in V shape and enables great air-flow rates with low pressure
drop and compact installation sizes; the filter medium is not regenerable; installation
depths amount to 47 mm with Z-50 and 92 mm with Z-100
Application example:
filtration of coarse dust in climate control and air handling units
Special features:
pleating of the filter material results in enlargement of the active filter surface and thus
increases air-flow rate and dust-holding capacity; high efficiency thanks to low initial
differential pressure even with large air flow rates; filter cells can be completely incinerated.
Areas of application:
standard climate control facilities and air handling units, pre-filters for laminar flow
units, pre-filters for high value HVAC systems, automobile industry and paint finishing
lines
Specifications:
Form of delivery/
order numbers:
Filter cells
Z-50-G4
Z-50-F5
Z-100-G4
Z-100-M5
Filter class
[EN 779]
G4
F5
G4
M5
Installation depth/thickness
[mm]
47
47
92
92
Nominal air flow rate
[m³/hm²]
7200
5100
7200
5100
Initial pressure drop
[Pa]
42
55
31
47
Maximum allowed pressure
drop
[Pa]
250
450
250
450
Mean Filtration efficiency
[%]
94.0
98.0
93.0
98.0
Mean Efficiency
[%]
–
> 40.0
–
> 40.0
Max. operating temperature
[°C]
70
70
70
70
Max. rel. air humidity
[%]
100
100
100
100
Z-50/
Z-100
Size
W/H [mm]
Filter cell
Weight/
unit [kg]
packaging unit:
Order-Nr.
G4
Order-Nr.
M5
12
6
Z-50
394/495/47
394/622/47
495/495/47
495/622/47
592/592/47
0.5
0.6
0.7
0.8
0.9
40 65 131
40 65 531
40 65 231
40 65 631
40 65 331
22 85 301
22 85 302
22 85 303
22 85 304
22 85 305
Z-100
394/495/92
394/622/92
495/495/92
495/622/92
592/592/92
0.7
0.8
0.8
1.0
1.2
00 39 061
40 66 031
40 65 831
40 66 131
00 39 980
22 85 306
22 85 307
22 85 308
22 85 309
22 85 310
PR-2009-0099-GB • Subject to modifications • Status K12-02/2013
19
Filter cells
GEA Air Filters
FIBERGLAS
FILTERGLAS cells consist of tightly intermeshed glass fibres with special closure
fleece on the pure-air side, on two sides, the filter cell is framed with large-perforation
metal support plates in a moisture-resistant carton frame enclosure with a crimp fold
Pressure drop [Pa]
Pressure drop diagram:
200
180
160
140
120
100
80
60
40
20
0
Curve applies to size 480 mm x 480 mm
FIBERGLAS
0
100
200
300
400
500
Air flow rate [m³/h]
Specifications:
Form of delivery/
order numbers:
FIBERGLAS
Filter class
[EN 779]
M5
Installation depth/thickness
[mm]
14
Nominal air flow rate
[m³/h]
500
Initial pressure drop
[Pa]
180
Maximum allowed pressure
drop
[Pa]
450
Mean filtration efficiency
[%]
99.0
Mean Efficiency
[%]
55.4
Max. operating temperature
[°C]
80
Max. rel. air humidity
[%]
100
FIBERGLAS
Size W/H [mm]
Weight/unit [kg]
Order number
0.4
40 03 021
Filter cell, packaging unit 25
FIBERGLAS
20
480/480
PR-2009-0099-GB • Subject to modifications • Status K12-02/2013
Bag Filter
GEA Air Filters
MULTISACK Overview
MULTISACK synthetic (S) and glass (G) bag filters are composed of several filter
bags. The individual bags, made of synthetic fibre or micro-fibreglass fleece, have
been shaped so as to provide wedge-shaped filter bags.
The spacers in the individual filter bags ensure complete utilization of the full bag depth
and, in turn, of the entire filter surface. The ready-to-install filter bags are secured to
sturdy U-shaped profile frames (25 mm) by clamp fittings. The frame is made of galvanized sheet steel.
Width, height and depth are specified like in the drawing!
Specifications:
MULTISACK
K35
K50
K55
K65
K85
K95
G55
G65
G85
G95
Filter class *
[EN 779]
G4
M5
M5
M6
F7
F8
M5
M6
F7
F9
Installation depth
[mm]
360
500
600
600
600
600
600
600
600
600
Number of filter bags
[quantity]
4
6
6
8
8
8
6
8
8
10
Nominal air flow rate
[m³/h]
3400
3400
3400
3400
3400
3400
3400
3400
3400
3400
Initial pressure drop
[Pa]
25
43
50
65
90
150
50
50
80
155
Maximum allowed
pressure drop
[Pa]
250
450
450
450
450
450
450
450
450
450
Mean Filtration efficiency
[%]
90.0
92.7
96.1
99.2
99.4
99.5
96.8
98.4
99.2
99.8
Mean Efficiency
[%]
–
46.1
51.9
71.9
86.4
91.3
50.4
62.8
88.4
95.4
Max. operating temperature
[°C]
80
80
80
80
80
80
80
80
80
80
Max. rel. air humidity
[%]
100
100
100
100
100
100
100
100
100
100
* Classification is valid at air-flow volume of 3400 m3/h for size 592/592 mm
MULTISACK
Product description 1
F55, F85
flame resistant treatment
S55, S85
antiseptic treatment
K35, K50, K55, K65, K85, K95
Synthetic fibre fleece
G55, G65, G85, G95
Micro-fibreglass fleece
Rated volume flow [m³/h]
1
Size W/H [mm] 592/287
2
287/287
850-1.000
3
287/592
1700-2.100
5
490/592
2800-3.550
6
592/592
3400-4.250
0600
/
08
/
05
/
EX
opt. model
/
Frame
thickness
V
Nr. filter bags
6
Bag length
K6 5
Frame type
MULTISACK
modular grid
nominal air flow
Example:
Filter medium
Unit type code:
1.700-2.100
other special sizes on request
K
Plastic
V
Galvanized metal sheet
0195; 0360; 0380; 0500; 0534; 0600 Standard size [mm]
individual size on request
Number of bags according to filter class – refer to the table above „Technical Data“
05
Standard size [mm]
00
20 mm in galvanized frame
N
neutral
EX
EX-version (available in micro-glass fibre medium)
PR-2009-0099-GB • Subject to modifications • Status K12-02/2013
21
Bag Filter
GEA Air Filters
MULTISACK K35/K50
MULTISACK K35/K50 bag filters consist of synthetic fibre fleece
Application
coarse-, fine and submicron particle filtration
Special features:
The spacers ensure complete utilization of the full bag length; sealing of spacer seams;
as compared to rated air-flow volume - operating air-flow volume can be increased by
25%
Areas of application:
all HVAC and air handling installations with a filtration function
K35 fulfills filter class G4
K50 fulfills filter class M5
Installation instruction
Pressure drop [Pa]
Pressure drop diagram:
Curve applies to size 592 mm x 592 mm
Air flow rate [m³/h]
Form of delivery:
Bag filter MULTISACK K35/K50
Model with a galvanized frame – surcharge for plastic frame on request
MULTISACK
Size
W/H [mm]
Number
of Bags [#]
Bag
Length [mm]
Filter
Area [m²]
Bag
Length [mm]
Filter
Area [m2]
Bag
Length [mm]
Filter surface
[m²]
K35-1
592/287
4
6
195
0.5
0.7
360
0.9
1.3
600
1.5
2.2
K35-2
287/287
2
3
195
0.2
0.3
360
0.5
0.7
600
0.7
1.1
K35-3
287/592
2
3
195
0.5
0.7
360
0.9
1.3
600
1.5
2.2
K35-5
490/592
3
5
195
0.7
1.2
360
1.3
2.2
600
2.2
3.8
K35-6
592/592
4
6
195
1.0
1.5
360
1.8
2.7
600
3.0
4.4
Bag filter K35
MULTISACK
Size W/H [mm]
Number of bags [quantity]
Bag length [mm]
Filter surface [m²]
Bag filter K50
K50-1
592/287
6
500
1.8
K50-2
287/287
3
500
0.9
K50-3
287/592
3
500
1.8
K50-5
490/592
5
500
3.0
K50-6
592/592
6
500
3.6
22
PR-2009-0099-GB • Subject to modifications • Status K12-02/2013
Bag Filter
GEA Air Filters
MULTISACK K55/K65
MULTISACK K55/K65 bag filters consist of synthetic fibre fleece
Application
coarse-, fine and submicron particle filtration
Special features:
Spacers ensure complete utilization of the filter bag depth; spacer seams
are sealed; compared to rated air-flow volume - operating air-flow volume
can be increased by 25%;
Filters with fire protection are optional;
Filters with antiseptic features are optional as well;
FireTex and SepTex filters meet standards for fire protection class B as of DIN EN 13
501-1 2007
K55 filters fulfil filter class M5
K65 fulfills filter class M6
Areas of application:
all HVAC and air handling installations with
a filtration function
Pressure drop diagram: Curve applies to size 592 mm x 592 mm
Installation instruction
200
Pressure drop [Pa]
150
100
K 65
50
0
K 55
0
680 1360 2040 2720 3400
Air flow rate [m³/h]
Form of delivery:
Bag filter MULTISACK K55/K65
Model with a galvanized frame – surcharge for plastic frame on request
Multisack
Size
W/H
[mm]
Number
of bags
[quantity]
Bag
length
[mm]
Filter
surface
[m²]
Energy
Class
Bag
length
[mm]
Filter
surface
[m²]
Energy
Class
Bag
length
[mm]
Filter
surface
[m²]
Energy
Class
6
360
1.3
B
500
1.8
B
600
2.2
B
B
Bag filter K55
K55-1
592/287
K55-2
287/287
3
360
0.7
B
500
0.8
B
600
1.2
K55-3
287/592
3
360
1.3
B
500
1.8
B
600
2.2
B
K55-5
490/592
5
360
2.2
B
500
3.2
B
600
3.8
B
K55-6
592/592
6
360
2.7
B
500
3.8
B
600
4.4
B
MULTISACK
Size
W/H/D
[mm]
Number
of bags
[quantity]
Bag
length
[mm]
Filter
surface
[m²]
Energy
Class
Bag
length
[mm]
Filter
surface
[m²]
Energy
Class
Bag
length
[mm]
Filter
surface
[m²]
Energy
Class
Bag filter K65
K65-1
592/287
6
8
380
1.5
1.9
G
534
1.9
2.6
G
600
2.2
3.0
G
K65-2
287/287
3
4
380
0.7
0.9
G
534
0.9
1.3
G
600
1.1
1.5
G
K65-3
287/592
3
4
380
1.5
1.9
G
534
1.9
2.6
G
600
2.2
3.0
G
K65-5
490/592
5
6
380
2.4
2.9
G
534
3.3
3.9
G
600
3.8
4.4
G
K65-6
592/592
6
8
380
2.9
3.9
G
534
3.9
5.2
G
600
4.4
6.0
G
PR-2009-0099-GB • Subject to modifications • Status K12-02/2013
23
Bag Filter
GEA Air Filters
MULTISACK K85/K95
MULTISACK K85/K95 bag filters consist of synthetic fibre fleece
Application
coarse-, fine and submicron particle filtration
Special feature:
Spacers ensure complete utilization of the filter bag depth; spacer seams
are sealed; compared to rated air-flow volume - operating air-flow volume
can be increased by 25%;
Filters with fire protection are optional;
Filters with antiseptic features are optional as well;
FireTex and SepTex filters meet standards for fire protection class B as of DIN EN 13
501-1 2007
K85 fulfills filter class F7
K95 fulfills filter class F8
Areas of application:
all HVAC and air handling installations with a filtration function
Installation instruction
Pressure drop [Pa]
Pressure drop diagram: Curve applies to size 592 mm x 592 mm
Air flow rate [m³/h]
Form of delivery:
Bag filter MULTISACK K85/K95
Model with a galvanized frame – surcharge for plastic frame on request
MULTISACK
Size
W/H
[mm]
Number
of Bags
[#]
Bag
length
[mm]
Filter
surface
[m²]
Energy
Class
Bag
Length
[mm]
Filter
surface
[m²]
Energy
Class
Bag
Length
[mm]
Filter
surface
[m²]
Energy
Class
K85-1
592/287
6
8
380
1.5
1.9
E
E
534
1.9
2.6
D
C
600
2.2
3.0
C
C
K85-2
287/287
3
4
380
0.7
0.9
E
E
534
0.9
1.3
D
C
600
1.1
1.5
C
C
K85-3
287/592
3
4
380
1.5
1.9
E
E
534
1.9
2.6
D
C
600
2.2
3.0
C
C
K85-5
490/592
5
6
380
2.4
2.9
E
E
534
3.3
3.9
D
C
600
3.8
4.4
C
C
K85-6
592/592
6
8
380
2.9
3.9
E
E
534
3.9
5.2
D
C
600
4.4
6.0
C
C
Size
W/H
[mm]
Number
of bags
[quantity]
Bag
length
[mm]
Filter
surface
[m²]
Energy
Class
Bag
length
[mm]
Filter
surface
[m²]
Energy
Class
Bag
length
[mm]
Filter
surface
[m²]
Energy
Class
Bag filter K85
MULTISACK
Bag filter K95
K95-1
592/287
8
380
1.9
E
534
2.6
C
600
3.0
C
K95-2
287/287
4
380
0.9
E
534
1.3
C
600
1.5
C
K95-3
287/592
4
380
1.9
E
534
2.6
C
600
3.0
C
K95-5
490/592
6
380
2.9
E
534
3.9
C
600
4.4
C
K95-6
592/592
8
380
3.9
E
534
5.2
C
600
6.0
C
24
PR-2009-0099-GB • Subject to modifications • Status K12-02/2013
Bag Filter
GEA Air Filters
MULTISACK G55/G65
MULTISACK G55/G65 bag filters consist of micro-fibreglass fleece
Application example:
filtration of fine and superfine dust
Special features:
The spacers ensure complete utilization of the full bag depth; sealing of spacer seams;
additional pure-air side gauze prevents migration of fibreglass particles; compared to
rated air-flow volume - operating air-flow volume can be increased by
25%; as an option this filter model is available as EX protection version
G55 fulfills filter class M5
G65 fulfills filter class M6
Areas of application:
all HVAC and air handling installations with
a filtration function
o
Pressure drop diagram: Curve applies to size 592 mm x 592 mm
Pressure drop [Pa]
Installation instruction
Air flow rate [m³/h]
Form of delivery:
MULTISACK bag filter G55/G65
Model with a galvanized frame – surcharge for plastic frame on request
MULTISACK
Size
W/H
[mm]
Number
of Bags
[#]
Bag
length
[mm]
Filter
surface
[m²]
Energy
Class
Bag
length
[mm]
Filter
surface
[m²]
Energy
Class
Bag
length
[mm]
Filter
surface
[m²]
Energy
Class
Bag filter G55
G55-1
592/287
6
380
1.5
G
534
1.9
C
600
2.2
B
G55-2
287/287
3
380
0.7
G
534
0.9
C
600
1.1
B
G55-3
287/592
3
380
1.5
G
534
1.9
C
600
2.2
B
G55-5
490/592
5
380
2.4
G
534
3.3
C
600
3.8
B
G55-6
592/592
6
380
2.9
C
534
3.9
C
600
4.4
B
Bag
length
[mm]
Filter
surface
[m²]
Energy
Class
MULTISACK
Size
W/H
[mm]
Number of
bags
[quantity]
Bag
length
[mm]
Filter
surface
[m²]
Energy
Class
Bag
length
[mm]
Filter
surface
[m²]
Energy
Class
G65-1
592/287
8
10
12
380
1.9
2.4
2.8
D
C
B
534
2.6
3.2
3.9
A
A
A
600
3.0
3.8
4.5
A
A
A
G65-2
287/287
4
5
6
380
0.9
1.1
1.4
D
C
B
534
1.3
1.6
1.9
A
A
A
600
1.5
1.9
2.2
A
A
A
G65-3
287/592
4
5
6
380
1.9
2.4
2.8
D
C
B
534
2.6
3.2
3.9
A
A
A
600
3.0
3.8
4.4
A
A
A
G65-5
490/592
6
8
10
380
2.9
3.9
4.7
D
C
B
534
3.9
5.2
6.6
A
A
A
600
4.4
6.0
7.4
A
A
A
G65-6
592/592
8
10
12
380
3.9
4.8
5.6
D
C
B
534
5.2
6.5
7.9
A
A
A
600
6.0
7.5
8.8
A
A
A
Bag filter G65
PR-2009-0099-GB • Subject to modifications • Status K12-02/2013
25
Bag Filter
GEA Air Filters
MULTISACK G85/G95
MULTISACK G85/G95 bag filters
consist of micro-fibreglass fleece
Application example:
filtration of fine and superfine dust
Special features:
The spacers ensure complete utilization of the full bag depth; sealing of spacer seams;
additional pure-air side gauze prevents migration of fibreglass particles; compared to
rated air-flow volume - operating air-flow volume can be increased by 25%; as an
option this filter model is available as EX protection type.
G85 fulfills filter class F7
G95 fulfills filter class F9
Areas of application:
all HVAC and air handling installations with
a filtration function
Installation instruction
Pressure drop [Pa]
Pressure drop diagram: Curve applies to size 592 mm x 592 mm
Air flow rate [m³/h]
26
PR-2009-0099-GB • Subject to modifications • Status K12-02/2013
Bag Filter
GEA Air Filters
MULTISACK G85/G95
Form of delivery:
MULTISACK bag filter G85/G95
Model with a galvanized frame – surcharge for plastic frame on request
MULTISACK
Size
W/H
[mm]
Number
of Bags
[#]
Bag
Length
[mm]
Filter
surface
[m²]
Energy
Class
Bag
Length
[mm]
Filter
surface
[m²]
Energy
Class
Bag
Length
[mm]
Filter
surface
[m²]
Energy
Class
G85-1
592/287
8
10
12
380
1.9
2.4
2.8
D
C
B
534
2.6
3.2
3.9
A
A
A
600
3.0
3.8
4.5
A
A
A
G85-2
287/287
4
5
6
380
0.9
1.1
1.4
D
C
B
534
1.3
1.6
1.9
A
A
A
600
1.5
1.9
2.2
A
A
A
G85-3
287/592
4
5
6
380
1.9
2.4
2.8
D
C
B
534
2.6
3.2
3.9
A
A
A
600
3.0
3.8
4.4
A
A
A
G85-5
490/592
6
8
10
380
2.9
3.9
4.7
D
C
B
534
3.9
5.2
6.6
A
A
A
600
4.4
6.0
7.4
A
A
A
G85-6
592/592
8
10
12
380
3.9
4.8
5.6
D
C
B
534
5.2
6.5
7.9
A
A
A
600
6.0
7.5
8.8
A
A
A
Bag
length
[mm]
Filter
surface
[m²]
Energy
Class
Bag filter G85
MULTISACK
Size
W/H
[mm]
Number
of bags
[#]
Bag
length
[mm]
Filter
surface
[m²]
Energy
Class
Bag
Length
[mm]
Filter
surface
[m²]
Energy
Class
G95-1
592/287
8
10
12
380
1.9
2.4
2.8
D
C
B
534
2.6
3.2
3.9
B
B
B
600
3.0
3.8
4.5
B
A
A
G95-2
287/287
4
5
6
380
0.9
1.1
1.4
D
C
B
534
1.3
1.6
1.9
B
B
B
600
1.5
1.9
2.2
B
A
A
G95-3
287/592
4
5
6
380
1.9
2.4
2.8
D
C
B
534
2.6
3.2
3.9
B
B
B
600
3.0
3.8
4.4
B
A
A
G95-5
490/592
6
8
10
380
2.9
3.9
4.7
D
C
B
534
3.9
5.2
6.6
B
B
B
600
4.4
6.0
7.4
B
A
A
G95-6
592/592
8
10
12
380
3.9
4.8
5.6
D
C
B
534
5.2
6.5
7.9
B
B
B
600
6.0
7.5
8.8
B
A
A
Bag filter G95
PR-2009-0099-GB • Subject to modifications • Status K12-02/2013
27
Filter Elements
GEA Air Filters
MULTIFORM Overview
MULTIFORM filter elements are made of micro-fibreglass fleece which is pleated to
form a stable package of folds; the number and the height of the folds are optimally
designed to match operating conditions; peripheral but merged synthetic strips keep
individual pleats at a distance along the entire pleat depth and ensure greater stability
and complete utilisation of the entire filter surface; the individual filter plates are
arranged in a V-shape (in 4 compartments) inside a synthetic frame made of ABS, so
as to assure a stable form of the filter plates, and are glued to assure air-tightness.
Specifications:
MF 65
Filter element
Filter class
[EN 779]
[EN 1822]
MF 85
M6
F7
MF 90
F8
MF 95
MF 98
MF 99
MF 100
MF 101
F9
–
E10
–
E11
–
E12
–
H13
Installation depth/thickness [mm]
298
298
298
298
298
298
298
298
Initial pressure drop
[Pa]
100
110
125
150
185
185
290
290
Maximum allowed pressure
[Pa]
drop
450
450
450
450
650
650
650
650
> 98.0
–
> 98.0
–
> 98.0
–
> 98.0
–
–
> 85.0
–
> 95.0
–
> 99.5
–
> 99.95
72,6
85,9
93,5
96,2
–
–
–
–
Max. operating temperature [°C]
70
70
70
70
70
70
70
70
Max. rel. air humidity
100
100
100
100
100
100
100
100
Mean Arrestance
acc. to DIN EN 779:2012
acc. to DIN EN 1822:2011
[%]
Mean Efficiency
[%]
[%]
MF
MULTIFORM
65
M6
85
F7
90
F8
95
F9
98
E10
99
E11
100/101
E12/H13
95
-
6
Size code
(rated size)
MF
Type
Example:
Product
Description
Unit type code:
Rated size
28
3
592 x 287 mm
5
592 x 490 mm
6
592 x 592 mm
PR-2009-0099-GB • Subject to modifications • Status K12-02/2013
Filter Elements
GEA Air Filters
MULTIFORM MF65/MF85/MF90
Filter Elements MULTIFORM MF65, MF85 and MF90
Application example:
all applications requiring maximum operating safety and highest standards in air purity;
for filtration of fine and superfine dust, bacteria, mould etc. in HVAC systems and air
handling units of all types, as well as a pre-filter for HEPA filters
Special features:
self-supporting, shape-steady design with high mechanical stability; great air flow rate
with small installation depth; large filter surface; can be completely incinerated
Areas of application:
standard climate control facilities and air handling units, photographic, electrical and
food product industry, high value assembly rooms and switchgear facilities, chemical,
pharmaceutical industry and hospitals, pre-filters for clean-room facilities, air intake filter for power stations
MULTIFORM MF65, MF85 and MF90 filter elements
are certified by the Eurovent
AIR FILTERS
CLASS F5-F9
Pressure drop diagram:
Pressure drop [Pa]
Curve applies to size
592 mm x 592 mm
Air flow rate [m³/h]
Form of delivery:
Filter Elements MULTIFORM MF65, MF85 and MF90
Design without sealing – sealing and handle guard on request
Type
Size W/H
[mm]
Air flow rate
[m³/h]
Filter
Class
MF65-3
MF65-5
MF65-6
592/287
592/490
592/592
2125
3500
4250
M6
7.0
13.0
16.0
3.5
4.5
5.5
MF85-3
MF85-5
MF85-6
592/287
592/490
592/592
2125
3500
4250
F7
8.0
15.0
18.0
3.5
4.5
5.5
MF90-3
MF90-5
MF90-6
592/287
592/490
592/592
2125
3500
4250
F8
8.0
15.0
18.0
3.5
4.5
5.5
PR-2009-0099-GB • Subject to modifications • Status K12-02/2013
Filter surface Approx. weight
[m²]
[kg]
29
Filter Elements
GEA Air Filters
MULTIFORM-Eco MFEC55 /MFEC65/MFEC85
Filter Elements MULTIFORM-Eco MFEC55, MFEC65 and MFEC85
Application example:
all applications requiring maximum operating safety and highest standards in air purity;
for filtration of fine and superfine dust, bacteria, mould etc. in HVAC systems and air
handling units of all types, as well as a pre-filter for HEPA filters
Special features:
self-supporting, shape-steady design with high mechanical stability; great air flow rate
with small installation depth; large filter surface; can be completely incinerated
Areas of application:
standard climate control facilities and air handling units, photographic, electrical and
food product industry, high value assembly rooms and switchgear facilities, chemical,
pharmaceutical industry and hospitals, pre-filters for clean-room facilities, air intake filter for power stations
All three filter classes of MULTIFORM Eco are equipped with a condensate drip tray
and handles for easy transport. The condensate drip tray drains excess liquids more
readily The handles ensures easy transport on-site
Filter elements MULTIFORM-Eco MFEC55, MFEC65 and MFEC85
are certified by the Eurovent
Pressure drop [Pa]
Pressure drop diagram:
MFEC 85-6
MFEC 55-6
MFEC 65-6
Air flow rate [m³/h]
Form of delivery:
Filter Elements MULTIFORM-Eco MFEC55, MFEC65 and MFEC85
Design without gasket – gaskets available on special request
30
Type
Size W/H/D
[mm]
Air flow rate
[m³/h]
Filter
Class
Filter surface Approx. weight
[m²]
[kg]
MFEC55-3
MFEC55-5
MFEC55-6
592/287/292
592/490/292
592/592/292
2125
3500
4250
M5
5.5
10.0
12.3
2.4
3.5
4.1
MFEC65-3
MFEC65-5
MFEC65-6
592/287/292
592/490/292
592/592/292
2125
3500
4250
M6
6.8
12.5
15.3
2.4
3.5
4.1
MFEC85-3
MFEC85-5
MFEC85-6
592/287/292
592/490/292
592/592/292
2125
3500
4250
F7
6.8
12.5
15.3
2.4
3.5
4.1
PR-2009-0099-GB • Subject to modifications • Status K12-02/2013
Filter Elements
GEA Air Filters
MULTIFORM MF95/MF98/MF99
Filter Elements MULTIFORM MF95, MF98 and MF99
Application example:
all applications requiring maximum operating safety and highest standards in air purity;
for filtration of fine and superfine dust, bacteria, mould etc. in HVAC systems and air
handling units of all types, as well as a pre-filter for HEPA filters
Special features:
self-supporting, shape-steady design with high mechanical stability; great air flow rate
with small installation depth; large filter surface; can be completely incinerated
Areas of application:
standard climate control facilities and air handling units, photographic, electrical and
food product industry, high value assembly rooms and switchgear facilities, chemical,
pharmaceutical industry and hospitals, pre-filters for clean-room facilities, air intake filter for power stations
AIR FILTERS
CLASS F5-F9
Filter Elements MULTIFORM MF95 are certified by the Eurovent
Pressure drop diagram:
Pressure drop [Pa]
250
Curve applies to size
592 mm x 592 mm
-&99
200
-&98
150
-&95
100
50
0
0
850
2550
4250
Air flow rate [m³/h]
Form of delivery:
Filter Elements MULTIFORM MF95, MF98 and MF99
Design without sealing – sealing and handle guard on request
Type
Size W/H
[mm]
Air flow rate
[m³/h]
Filter
Class
MF95-3
MF95-5
MF95-6
592/287
592/490
592/592
2125
3500
4250
F9
8.0
15.0
18.0
3.5
4.5
5.5
MF98-3
MF98-6
592/287
592/592
2125
4250
E10
8.0
18.0
3.5
5.5
MF99-3
MF99-6
592/287
592/592
1700
3400
E11
8.0
18.0
3.5
5.5
PR-2009-0099-GB • Subject to modifications • Status K12-02/2013
Filter surface Approx. weight
[m²]
[kg]
31
Filter Elements
GEA Air Filters
MULTIFORM MF100/101
Filter Elements MULTIFORM MF100/101
Application example:
all applications requiring maximum operating safety and highest standards in air purity;
for filtration of fine and superfine dust, bacteria, mould etc. in HVAC systems and air
handling units of all types, as well as a pre-filter for HEPA filters
Special features:
self-supporting, shape-steady design with high mechanical stability; great air flow rate
with small installation depth; large filter surface; can be completely incinerated
MULTIFORM MF100
Areas of application:
standard climate control facilities and air handling units, photographic, electrical and
food product industry, high value assembly rooms and switchgear facilities, chemical,
pharmaceutical industry and hospitals, pre-filters for clean-room facilities, air intake filter for power stations
MULTIFORM MF101
Pressure drop diagram:
400
Curve applies to Multiform 100/101
size 592 mm x 592 mm
Pressure drop [Pa]
350
MF100/101
300
250
200
150
100
50
0
0
850
2550
4250
Air flow rate [m³/h]
Form of delivery:
Filter Elements MULTIFORM MF100/101
The MF100 has a grip protection and of aluminium on the clean air side in its standard design;
the MF101 can be equipped with a polished grip protection grid on special request
Design without gasket – gaskets available on special request
32
Type
Size W/H
[mm]
Air flow rate
[m³/h]
Filter
Class
Filter surface Approx. weight
[m²]
[kg]
MF100-3
MF100-6
592/287
592/592
1700
3400
E12
12.0
26.0
5.5
9.0
MF101-3
MF101-6
592/287
592/592
1700
3400
H13
12.0
26.0
5.5
9.0
PR-2009-0099-GB • Subject to modifications • Status K12-02/2013
Filter Elements
GEA Air Filters
MULTITHERM Overview
MULTITHERM filter elements are made of deeply-folded, paper-like micro-fibre
fleece; the position of the folds is stabilised through:
– wave-shaped aluminium separators (models: F, T, H, E, S with Al-separators)
NOTE!
Installation of MULTITHERM filter elements can only be done with vertically arranged separators and horizontal air flow.
– Filter-material strips to separate the folds (aluminium-free C and D-design)
– Separators are designed for an air flow on both sides
The filter package is inserted dry without casting in a riveted filter frame (except F
model) made of sendzimir-galvanized sheet steel or stainless steel with grip protection
on both sides; with F model (without brackets) a one-sided peripheral flange is
mounted where all materials satisfy stipulations pertaining to the absence of silicone,
and are temperature resistant up to 250°C; for units with critical air-flow conditions - a
modified model (TP) can be supplied
Specifications:
MT 60
Filter element MULTITHERM
Filter class
[EN 779]
Installation depth/thickness
[mm]
MT 90
M6
F8
40/55/78/90/150/292
40/55/78/90/150/292
+7
+7
Glass-fibre peripheral belt seal [mm]
Maximum allowed pressure
drop
[Pa]
450
450
Mean Filtration efficiency
[%]
> 98.0
> 98.0
Mean Efficiency
[%]
> 60.0
> 90.0
Max. operating temperature
[°C]
250
250
Max. rel. air humidity
[%]
100
100
MT
MULTITHERM
60
90
F6
F8
C
D
S
E
G
H
F
T
depth
depth
depth
depth
depth
depth
depth
depth
40
55
78
90
150
150
292
292
Installation depth
-
1800
/
V
2
Seal
S
Frame type
90
nominal air
flow volume
MT
Type
Example:
Product
Description
Unit type code:
mm
mm
mm
mm
mm (flange)
mm
mm (flange)
mm
Rated volume flow rate – refer to table „form of delivery/order number“ on the next page
V
steel, galvanized
1
2
on dust-air side – standard
on pure-air side
NOTE!
The standard size of a filter box with a flange design makes up 560 mm.
PR-2009-0099-GB • Subject to modifications • Status K12-02/2013
33
Filter Elements
GEA Air Filters
MULTITHERM MT60/MT90
Filter elements MULTITHERM MT60 und MT90
Application example:
supply and recirculating-air units for filtration of fine and superfine dust (filter classes F
6/F 8) at high temperatures
Special features:
great air flow rate with small installation depth; temperature-resistant up to 250 °C,
easy separation of a filter element from a frame by using brackets, satisfies stipulations
pertaining to the absence of silicone
Application area:
surface technology, drying equipment, automobile industry
MULTITHERM MT60 and MT90 filter elements are certified by the Eurovent
AIR FILTERS
CLASS F5-F9
Pressure drop diagram:
Pressure drop [Pa]
Curve applies to size
610 mm x 610 mm
Air flow rate [m³/h]
Form of delivery:
Filter elements MULTITHERM MT60 und MT90
Type
Size W/H/D
[mm]
Volume flow differential pressure
[m³/h/Pa]
Filter
Class
Filter surface
[m²]
Approx. weight
[kg]
Installation depth 40 mm and 55 mm, aluminium-free compact design
MT60-C
490/490/40
1500/125
M6
4.0
1.5
MT60-D
610/610/55
915/457/55
915/610/55
1800/85
2000/85
2700/85
M6
8.0
9.0
12.0
3.5
4.5
5.5
F8
4.0
1.5
F8
8.0
9.0
12.0
3.5
4.5
5.5
MT90-C
490/490/40
1500/125
MT90-D
610/610/55
915/457/55
915/610/55
1800/110
2000/110
2700/110
Installation depth 78 mm and 292 mm, design with aluminium separators
34
MT60-S
610/610/78
915/457/78
915/610/78
1800/90
2000/90
2700/90
M6
4.0
4.0
5.2
5.0
5.0
6.0
MT60-F
287/592/292
592/592/292
1700/140
3400/140
M6
4.5
9.0
4.5
7.0
MT60-T
305/610/292
610/610/292
2125/140
4250/140
M6
6.0
12.0
6.0
9.5
MT90-S
610/610/78
915/457/78
915/610/78
1800/115
2000/115
2700/115
F8
4.0
4.5
6.0
5.0
5.5
6.5
MT90-F
287/592/292
592/592/292
1700/165
3400/165
F8
4.5
9.0
4.5
7.0
MT90-T
305/610/292
610/610/292
2125/165
4250/165
F8
6.0
12.0
6.0
9.5
PR-2009-0099-GB • Subject to modifications • Status K12-02/2013
Filter Elements
GEA Air Filters
MULTITHERM MT60/MT90
MULTIPLAN filter elements – medium uses special paper-like fleece made of superfine micro-glass fibres, which are processed to form a stable package of folds; number
and height of folds is designed to match the optimal rated operating points; here the
individual folds are separated down to the greatest depth of the folds by continuous
synthetic threads (hot melt) that are bonded together, which provides great stability as
a result of the compact fold structure; as standard version the filter element is provided
with a peripheral seal on the intake (dusty)-air side and the filter frame is made of MDF
(Multiplan I) or plastic (Multiplan II)
Specifications:
MULTIPLAN I
Filter Elements
MP 65
MP 85
MP 95
Filter class
[EN 779]
M6
F7
F9
Mean Filtration efficiency
[%]
98
>98
>99
Mean Efficiency
[%]
>60
>80
>95
Installation depth
[mm]
78/150/292
78/150/292
78/150/292
Nominal air flow rate *
[m³/h]
3000
3000
3000
Initial pressure drop
[Pa]
80
100
120
Maximum allowed pressure drop
[Pa]
450
450
450
Max. operating temperature
[°C]
80
80
80
Max. rel. air humidity
[%]
100
100
100
* applies to size 610/610
MULTIPLAN II
Filter Elements
MP 55
MP 65
MP 85
MP 95
Filter class
[EN 779]
M5
M6
F7
F9
Mean Filtration efficiency
[%]
98
98
>98
>99
Mean Efficiency
[%]
>50
>60
>80
>95
Installation depth
[mm]
48/96
48/96
48/96
48/96
1900/3400
1900/3400
1900/3400
1900/3400
Nominal air flow rate * [m³/h]
Initial pressure drop
[Pa]
50/80
60/90
80/110
130/140
Maximum allowed
pressure drop
[Pa]
450
450
450
450
Max. operating temperature
[°C]
70
70
70
70
Max. rel. air humidity
[%]
100
100
100
100
* applies to size 592/592
MULTIPLAN II + flange
Filter Elements
MP 55
MP 65
MP 85
MP 95
Filter class
[EN 779]
M5
M6
F7
F9
Mean Filtration efficiency
[%]
98
98
>98
>99
Mean Efficiency
[%]
>50
>60
>80
>95
Installation depth
[mm]
78/100
78/100
78/100
78/100
2400/3400
2400/3400
2400/3400
2400/3400
Nominal air flow rate * [m³/h]
Initial pressure drop
[Pa]
80
90
110
140
Maximum allowed
pressure drop
[Pa]
450
450
450
450
Max. operating temperature
[°C]
70
70
70
70
Max. rel. air humidity
[%]
100
100
100
100
* applies to size 592/592
PR-2009-0099-GB • Subject to modifications • Status K12-02/2013
35
Filter Elements
GEA Air Filters
MULTIPLAN type code
MP
MULTIPLAN
55
M5
65
M6
85
F7
95
F9
L
depth
48 mm
S
depth
78 mm
E
depth
90 mm
J
depth
H
depth
150 mm (flange)
T
depth
292 mm
SF
depth
JF
depth
M
G
1
N
Option
/
Seal position
3000
Seal design
-
Frame type
S
nominal air
flow volume
95
Installation depth
MP
Filter class
Example:
Product
Description
Type code Multiplan I and II:
96 mm
78 mm (flange)
100 mm
Rated volume flow rate – refer to table „form of delivery/order number“ on the next page
M
MDF
K
Synthetic
V
Galvanized steel
G
Polyurethane, foamed
F
Flat profile
0
Without
1
Seal on the dust-air side – Standard
2
Seal on pure-air side
3
Seal on both sides
N
neutral
36
PR-2009-0099-GB • Subject to modifications • Status K12-02/2013
Filter Elements
GEA Air Filters
MULTIPLAN I (MP65, 85, 95)
Filter elements MULTIPLAN I (MP65, 85, 95)
Application:
primarily as pre filter of epa and hepa filters; hereby improving the service intervals of
premium epa and hepa filters; filter classes M6/F7/F9
Special features:
high volume flows with small installation depth; great mechanical stability through
established fold design; metal-free separation of folds
Areas of application:
microelectronics, production of semiconductors, health care, chemical, pharmaceutical
industries, microbiology
Filter elements MULTIPLAN I (MP65, 85, 95) are certified by Eurovent
AIR FILTERS
CLASS F5-F9
Pressure drop diagrams:
Pressure drop [Pa]
Curve applies to size
610 mm x 610 mm
MP95
MP85
MP65
Air flow rate [m³/h]
Form of delivery:
Filter elements MULTIPLAN I (MP65, MP85 and MP95)
Standard configuration with PUR seal; galvanized frame and other dimensions are available on request
W/H/D + seal
[mm]
Air flow rate
[m³/h]
Filter surface
[m²]
Approx. weight
[kg]
Packaging unit
[# of pieces]
305/610/78
1500
5.0
3.3
1
610/610/78
3000
10.8
6.0
2
305/610/150
1500
5.0
5.5
2
610/610/150
3000
10.8
7.0
1
305/610/292
1500
5.0
9.6
2
610/610/292
3000
10.8
14.0
1
PR-2009-0099-GB • Subject to modifications • Status K12-02/2013
37
Filter Elements
GEA Air Filters
MULTIPLAN II (MP55, 65, 85, 95)
Filter elements MULTIPLAN II (MP55, 65, 85, 95)
Application:
primarily as pre filter of epa and hepa filters; hereby improving the service intervals of
premium epa and hepa filters; filter classes M5/M6/F7/F9
Special features:
high volume flows with small installation depth; great mechanical stability through
established fold design; metal-free separation of folds
Areas of application:
microelectronics, production of semiconductors, health care, chemical, pharmaceutical
industries, microbiology
AIR FILTERS
CLASS F5-F9
Pressure drop diagram:
for MULTIPLAN II and Multiplan II + flange
Pressure drop [Pa]
Curve applies to size
592 mm x 592 mm
Air flow rate [m³/h]
Form of delivery:
Filter elements MULTIPLAN II (MP55, MP65,
MP85 and MP95)
Standard configuration without seal; plastic
frame and other sizes are available on request
W/H/D
[mm]
Air flow rate
[m³/h]
Filter surface Approx. weight Packaging[m²]
[kg]
units
Filter elements MULTIPLAN II + flange
(MP55, MP65, MP85 and MP95)
Standard configuration without seal;
other dimensions are available on request
W/H/D
[mm]
Air flow rate
[m³/h]
Filter surface Approx. weight Packaging[m²]
[kg]
units
287/287/48
475
1.3
0.4
2
287/287/78
600
1.5
0.6
2
287/592/48
950
2.7
0.8
4
287/592/78
1200
3.6
1.1
1
305/610/48
1000
2.9
0.8
4
490/592/78
2000
6.7
1.8
1
490/592/48
1570
4.6
1.2
2
592/592/78
2400
8.3
2.1
1
592/592/48
1900
5.6
1.4
2
287/287/100
850
1.7
0.7
1
610/610/48
2000
6.0
1.4
2
287/592/100
1700
3.9
1.3
2
287/287/96
850
2.3
0.8
1
490/592/100
2800
7.1
2.1
1
287/592/96
1700
4.7
1.6
2
592/592/100
3400
8.8
2.4
1
305/610/96
1750
5.2
1.6
2
490/592/96
2800
8.2
2.3
1
592/592/96
3400
10.0
2.7
1
610/610/96
3500
10.7
2.8
1
38
PR-2009-0099-GB • Subject to modifications • Status K12-02/2013
Filter Elements
GEA Air Filters
MULTI 2004
MULTI 2004 filter elements consist of a frame and filter inserts; steel frame is corrosion-resistant as a result of an RAL 9011 surface finish; in the system frame, the filter
inserts are inserted with a magnetic-strip seal, in V shape. Safety grille on the pure-air
side prevents the elements from breaking through, the pleated filter packs are glued
airtight in a polyester-coated and moisture-resistant carton frame; for filtration of emulsion mist and dust - micro glass-fibre paper is used and for absorption of odour-intensive pollutants - activated-carbon foam.
Application example:
special inserts are used for filtration of emulsion mist, filtration of gaseous, odour-intensive pollutants in high value HVAC units
AIR FILTERS
CLASS F5-F9
Special features:
reusable filter frame; filter medium can be replaced without tools easily and fast; low
recycling and disposal costs (filter inserts can be fully incinerated); low shipping volume and weight in case of repeat orders for filter inserts and their disposal
Areas of application:
standard climate control facilities and air handling units, pre-filter for clean-room facilities, chemical, pharmaceutical and health-care industry, electronic and automobile
industry, filtration of emulsion mist and other mist types caused by inflammable liquids,
adsorption of odour and toxic pollutants
MULTI 2004 filter elements are certified by the Eurovent
Pressure drop diagram:
Curve applies to size
592 mm x 592 mm
Pressure drop [Pa]
Multi2004 95
Multi2004 85
Multi2004 65
Air flow rate [m³/h]
Technical data
form of delivery/order
numbers:
Filter Elements
Filter class
MULTI
MULTI
MULTI
2004 MF65 2004 MF85 2004 MF95
[EN 779]
MULTI
2004 AKK
MULTI
2004 AKS
M6
F7
F9
–
–
Installation depth/thickness [mm]
301
301
301
301
301
Nominal air flow rate
4250
4250
4250
–
–
–
–
–
2125
2125
[m³/h]
max. volume flow with acti[m³/h]
vated-carbon elements
Initial pressure drop
[Pa]
130
140
200
35
35
Maximum allowed
pressure drop
[Pa]
450
450
450
–
–
Mean Filtration efficiency
[%]
98,0
98,0
>99.0
–
–
Mean Efficiency
[%]
>60
>80
95
–
–
Max. operating temperture [°C]
80
80
80
40
40
Max. rel. air humidity
100
100
100
70
70
30 00 211
30 00 213
30 00 214
30 00 215
30 01 246
Order number
PR-2009-0099-GB • Subject to modifications • Status K12-02/2013
[%]
39
Filter Elements
GEA Air Filters
MULTI 2004 Holding Frame
MULTI 2004 Holding Frame for Filter Element
Areas of application:
as CDD wall frames or EBE duct air filters
Technical data/
form of delivery/
order numbers:
MULTI 2004 holding frame; colour RAL 9011 (anthracite)
Nominal size W/H/D
[mm]
287/592/301
490/592/301
592/592/301
Number of filter inserts
[quantity]
4
6
8
Nominal air flow rate (max.) [m³/h]
2125
3500
4250
max volume flow for
activated carbon elements
[m³/h]
1070
1750
2125
Weight/each
[kg]
4.2
5.1
6.0
30 00 406
30 00 405
30 00 210
30 00 907
30 00 907
–
Order number
Fixing slide with horizontal model
Order number
40
PR-2009-0099-GB • Subject to modifications • Status K12-02/2013
Filter Elements
GEA Air Filters
MULTICOL
MULTICOL filter elements – in these filters wave-shaped aluminium separators are
used for stabilisation instead of synthetic threads, package of folds in galvanized steel
frame; as an option flange is available on the dust-air side (EF model) or on the dust
and pure-air side (DF model)
Application example:
filtration of supply or extract air in climate control and air handling unit
Areas of application:
in areas with very irregular air flows involving unusual turbulences and
high dust concentration;
as an option - also available in EX protection
Pressure drop diagram:
Pressure drop [Pa]
Curve applies to size
592 mm x 592 mm
Air flow rate [m³/h]
Specifications:
MULTICOL
DF60/EF60
DF90/EF90
Filter class
[EN 779]
M6
F8
Installation depth
[mm]
292
292
Nominal air flow rate
[m³/h]
3400
3400
Initial pressure drop
[Pa]
130
170
Maximum allowed pressure
[Pa]
drop
450
450
Filter surface area
[m²]
10
10
Mean Filtration efficiency
[%]
98
98
Mean Efficiency
[%]
66
91
Max. operating temperature [°C]
80
80
PR-2009-0099-GB • Subject to modifications • Status K12-02/2013
41
Filter Elements
GEA Air Filters
MULTICOL
MC
MULTICOL
DF
Double flange
EF
Single flange
60
M6
90
F8
F
Installation depth 292
G
Installation depth 150
1
592/287
3
287/592
5
490/592
6
592/592
V
galvanized
0
without flange profile seal
1
flange profile seal on dust-air side
2
flange profile seal on pure-air side (standard with DF)
3
flange profile seal on both sides
A
standard model (592/592 = 10 m²)
B
extended surface model (592/592 = 13 m²)
C
reduced surface model (592/592 = 8 m²)
BV
burst protection galvanized steel
N
neutral
42
V
2
A
BV
N
Burst protection
Option
/
Option
3
Option
-
Frame
F
Model size
90
Design type
EF
Filter class
MC
Flange type
Example:
Product
Description
MULTICOL type code:
PR-2009-0099-GB • Subject to modifications • Status K12-02/2013
HEPA filters
GEA Air Filters
Overview
GEA Delbag high efficiency submicron particulate air (HEPA) filters consist of special, paper-like fleece made of superfine micro-glass fibres that have different filtration
and air-flow capacity depending on the filter class.
The filter fleece is processed to form a stable package of folds; number and height of
folds is designed for extended service life and to match the optimal rated operating
points and long service intervals.
The individual folds are separated down to the entire depth by continuous synthetic
threads (hot melt) that are bonded together, which provides great stability and even
thread runs as a result of the compact fold structure.
The packages of folds are cast airtight in robust frames; the filter frames are available
as MDF, plywood, aluminium and stainless steel.
Specifications:
HEPA filters
E11
H13
Filter class
[EN 1822]
E11
H13
Initial pressure drop
[Pa]
125
250
Maximum allowed pressure
drop
[Pa]
750
750
Mean Filtration efficiency
[%]
> 95.0
> 99.95
max operating temp.°C
[°C]
80
80
Max. rel. air humidity
[%]
100
100
H14
U15
> 99.995
> 99.9995
Technical Data
Filter Class (DIN EN 1822)
Filtration efficiency
[%]
Installation depth
[mm]
69 / 90 / 117
69 / 90 / 117
Initial pressure drop
[Pa]
125 / 100 / 85
155 / 125 / 105
Maximum allowed pressure
drop
[Pa]
600
600
Operating temperature
[max. °C]
80
80
rel. air humidity
[max. °C]
100
100
NOTE!
Specific pressure drop depends on overall unit depth
PR-2009-0099-GB • Subject to modifications • Status K12-02/2013
43
HEPA filters
GEA Air Filters
Description of Product Type Code
Installation depth150 mm
T
Installation depth292 mm
Seal
position
Installation depth78 mm
H
1
/
S
G
1
EX
optional
configuration
S
G
Seal
design
H13
M
Seal
position
E11
Filter class
/
Frame type
Filter class
M 13 F
1200
Seal
design
M 11 F
H
Frame type
M13F
Product
Description
Example:
nominal air
flow volume
Type code
pleated filter packs
E11 - U15
Installation depth
Description of product type code
Rated volume flow rate – refer to tables „form of delivery/order numbers“ on the next pages
Galvanized
G
Polyurethane
F
Flat profile
U
Test groove seal
1
dust air side – standard
2
pure-air side
Type code
aluminium separators
E11 - H13
Example:
M 11 A
Filter class
E11
M 13 A
Filter class
H13
H
Installation depth150 mm
T
Installation depth292 mm
M13A
T
1200
nominal air
flow volume
MDF
V
Installation depth
Aluminium
M
Product
Description
A
Rated volume flow rate – refer to tables „form of delivery/order numbers“ on the next pages
S
Plywood
V
Galvanized
G
Polyurethane
F
Flat profile
U
Test groove seal
1
dust air side – standard
2
pure-air side
N
neutral
EX
EX model
44
PR-2009-0099-GB • Subject to modifications • Status K12-02/2013
HEPA filters
GEA Air Filters
Description of Product Type Code
A
G
1
BR
2
Grille position
/
Type of
protection grille
600
Seal
design
A
Frame type
A14F
nominal air
flow volume
Example:
Installation
depth
pleated filter packs
Product
Description
Type code
A 14 F
Filter class
H14
U 15 F
Filter class
U15
A
Installation depth69 mm
S
Installation depth78 mm
E
Installation depth90 mm
B
Installation depth117 mm
Seal
position
H14 - U15
Rated volume flow rate –
refer to tables „form of delivery/order numbers“ on the next pages
Frame
A
Aluminium
G
Polyurethane
F
Flat profile
U
Test groove seal only available in frame depth 78 mm
1
dust air side – standard
2
pure-air side
pure-air side
3
both sides
Type code
V-shaped filter packs H13 - H14
M13V
Product
Example:
M 11 V
Filter class
E11
M 13 V
A 14 V
Filter class
Filter class
H13
H14
T
Installation depth292 mm
T
35 0 0
/
V
G
1
EX
optional
configuration
dust air side – standard
2
Seal
position
1
Seal
design
Aluminium
Frame type
painted steel
BA
nominal air
flow volume
BR
Installation
depth
Protection grille
Rated volume flow rate – refer to tables „form of delivery/order numbers“ on the next pages
V
Galvanized
N
Stainless steel
G
Polyurethane
F
Flat profile
U
Test groove seal
1
dust air side – standard
2
pure-air side
N
neutral
EX
EX model
PR-2009-0099-GB • Subject to modifications • Status K12-02/2013
45
HEPA filters
GEA Air Filters
E11 Panel Filter
GEA Delbag E11 EPA filters consists of fold packages that are cast in a frame with
polyurethane to ensure air tightness
Application example:
designed as final filters with great capacity in filtration of all aerosol types in a multiple
filter chain to be used in climate control and air handling units; for cleaning supply and
extract air in industrial processes; for filtration of health endangering dust, viruses and
bacteria
Special features:
great mechanical stability through established fold design; high volume flows with
small installation depth, metal-free separation of folds
Areas of application:
health-care industry, chemical, pharmaceutical production, food product industry,
electronics, production of semiconductors, nuclear technology
Pressure drop diagram:
Pressure drop [Pa]
150
125
100
75
50
25
0
0
20
40
60
80
100
Volume flow [%]
Form of delivery:
GEA Delbag E11 HEPA filters
Design with a MDF frame and PU semicircular seal – others seals and handle guard on request
Type M11FS installation depth 78 mm
Type M11FH installation depth 150 mm
Size
W/H
[mm]
air flow
volume
[m3/h]
filtration
surface
[m2]
Approx.
weight
[kg]
Size
W/H
[mm]
air flow
volume
[m3/h]
filtration
surface
[m2]
Approx.
weight
[kg]
305/305
260
300
2.2
2.9
2.0
2.1
260
300
2.2
2.8
3.6
3.8
305/305
420
520
3.6
4.7
7.5
8.0
305/610
550
640
4.7
6.2
3.3
3.4
550
710
4.7
6.0
5.4
5.9
305/610
930
1160
7.8
10.0
11.5
12.5
457/457
640
740
5.4
7.1
3.5
3.6
640
820
5.4
6.8
5.7
6.2
457/610
1450
1820
12.5
15.9
15.0
16.0
575/575
1060
1230
8.7
11.6
4.8
4.9
1060
1350
8.7
11.0
7.6
8.4
610/610
2000
2510
16.5
21.5
18.0
20.0
610/610
1200
1400
10.0
13.2
5.2
5.3
1200
1530
10.0
12.5
8.2
9.1
762/610
1060
1230
8.7
11.6
4.8
4.9
1060
1350
8.7
11.0
7.6
8.4
610/610
2000
2510
16.5
21.5
18.0
20.0
915/610
1850
2150
15.0
20.2
7.1
7.2
1850
2350
15.0
19.2
11.0
12.5
1220/
610
2250
2900
20.5
27.2
9.1
9.2
2500
3180
20.5
26.0
13.5
15.5
46
air flow
volume
[m3/h]
filtration
surface
[m2]
Approx.
weight
[kg]
Type M11FT installation depth 292 mm
PR-2009-0099-GB • Subject to modifications • Status K12-02/2013
HEPA filters
GEA Air Filters
E11 V-Shape
GEA Delbag H13 HEPA filters with aluminium separators – here wave-shaped aluminium separators are used for stabilisation instead of synthetic threads; the packages
of folds are cast in a wooden frame with polyurethane so as to be airtight
Application example:
designed as final filters with great capacity in filtration of all aerosol types in a multiple
filter chain to be used in climate control and air handling units; for cleaning supply and
extract air in industrial processes; for filtration of health endangering dust, viruses and
bacteria
Areas of application:
health-care industry, chemical, pharmaceutical production, food product industry, electronics, production of semiconductors, nuclear technology Filter design using aluminium separators makes operational temp. to max. 100 °C possible
optionally also available for high operating temperature to up to 250 °C
Pressure drop diagram:
Pressure drop [Pa]
250
200
150
100
50
0
0
20
40
60
80
100
Volume flow [%]
Form of delivery:
GEA Delbag H13 HEPA filters with aluminium separators
Model with a standard seal – other seals and handle guard on request
Type M13AH installation depth 150 mm
Size W/H/D +
seal
[mm]
air flow
volume
[m3/h]
Type M13AT installation depth 292 mm
filtration
surface
[m2]
Approx.
weight
[kg]
Size W/H/D +
seal
[mm]
air flow
volume
[m3/h]
filtration
surface
[m2]
Approx.
weight
[kg]
305/305/150 + 8
320
2.0
3.7
305/305/292 + 8
415
525
3.9
5.5
6.0
6.5
305/610/150 + 8
530
4.0
4.3
305/610/292 + 8
930
1160
8.0
12.0
9.5
10.0
610/610/150 + 8
1530
13.5
10.0
595/595/292 + 8
1900
15.9
14.5
762/610/150 + 8
1930
17.0
12.5
610/610/292 + 8
2000
2510
16.9
24.9
15.0
16.0
762/610/292 + 8
2540
21.4
19.3
PR-2009-0099-GB • Subject to modifications • Status K12-02/2013
47
HEPA filters
GEA Air Filters
H13 Panel Filter
GEA Delbag H13 HEPA filters consist of fold packages that are cast in a frame with
polyurethane to ensure air tightness
Application example:
designed as final filters with great capacity in filtration of all aerosol types in a multiple
filter chain to be used in climate control and air handling units; for cleaning supply and
extract air in industrial processes; for filtration of health endangering dust, viruses and
bacteria
Special features:
great mechanical stability through established fold design; high volume flows with
small installation depth, metal-free separation of folds
Areas of application:
health-care industry, chemical, pharmaceutical production, food product industry, electronics, production of semiconductors, nuclear technology
Pressure drop diagram:
Pressure drop [Pa]
250
200
150
100
50
0
0
20
40
60
80
100
Volume flow [%]
Form of delivery:
GEA Delbag H13 HEPA filters
Design with a MDF frame and PU semicircular seal – others seals and handle guard on request
Type M13FS installation depth 78 mm Type M13FH installation depth 150 mm
Size
W/H
[mm]
48
air flow
volume
[m3/h]
filtration
surface
[m2]
Approx.
weight
[kg]
air flow
volume
[m3/h]
Type M13FT installation depth 292 mm
filtration
surface
[m2]
Approx.
weight
[kg]
Size
W/H
[mm]
air flow
volume
[m3/h]
filtration
surface
[m2]
Approx.
weight
[kg]
305/305
260
300
2.2
2.9
2.0
2.1
260
300
2.2
2.8
3.6
3.8
305/305
420
520
3.6
4.7
7.5
8.0
305/610
550
640
4.7
6.2
3.3
3.4
550
710
4.7
6.0
5.4
5.9
305/610
930
1160
7.8
10.0
11.5
12.5
457/457
640
740
5.4
7.1
3.5
3.6
640
820
5.4
6.8
5.7
6.2
457/610
1450
1820
12.5
15.9
15.0
16.0
575/575
1060
1230
8.7
11.6
4.8
4.9
1060
1350
8.7
11.0
7.6
8.4
610/610
2000
2510
16.5
21.5
18.0
20.0
610/610
1200
1400
10.0
13.2
5.2
5.3
1200
1530
10.0
12.5
8.2
9.1
610/610
3000
29.5
23.5
915/610
1850
2150
15.0
20.2
7.1
7.2
1850
2350
15.0
19.2
11.0
12.5
1220/610
2250
2900
20.5
27.2
9.1
9.2
2500
3180
20.5
26.0
13.5
15.5
PR-2009-0099-GB • Subject to modifications • Status K12-02/2013
HEPA filters
GEA Air Filters
E11 V-Shape/H13 V-Shape
GEA Delbag E11/H13 HEPA in V shaped design filters in are cast so as to be airtight
in a U-shaped profile, they have a V-shaped arrangement.
Application example:
designed as final filters with great capacity in filtration of all aerosol types in a multiple
filter chain to be used in climate control and air handling units; for cleaning supply and
extract air in industrial processes; for filtration of health endangering dust, viruses and
bacteria
Special features:
great mechanical stability through established fold design;
high volume flows with small installation depth,
metal-free separation of folds,
an option available in EX protected version
Areas of application:
health-care industry, chemical, pharmaceutical production, food product industry,
electronics, production of semiconductors, nuclear technology
Pressure drop diagram:
E11 V-Shape HEPA filters
H13 V-shape HEPA filters
250
Pressure drop [Pa]
Pressure drop [Pa]
200
150
100
50
0
200
150
100
50
0
20
40
60
80
0
100
Volume flow [%]
0
20
40
60
80
100
Volume flow [%]
GEA Delbag E11/H13 HEPA filters in V-shape design
Design with a galvanized frame and PU semicircular seal – other seals and handle guard on request
Type M11VT (filter class E11)
Size W/H
[mm]
Air flow rate
[m³/h]
Filter surface
[m²]
Approx. weight
[kg]
305/305
730
830
7.5
9.0
5.0
5.5
305/610
1600
1800
18.0
22.0
8.0
8.5
610/610
3500
4000
36.0
40.0
15.0
15.5
Type M13VT (filter class H13)
Size W/H
[mm]
Air flow rate
[m³/h]
Filter surface
[m²]
Approx. weight
[kg]
305/305
730
830
7.5
9.0
5.0
5.5
305/610
1600
1800
18.0
22.0
8.0
8.5
610/610
3500
4000
36.0
40.0
15.0
15.5
PR-2009-0099-GB • Subject to modifications • Status K12-02/2013
49
HEPA filters
GEA Air Filters
H14/U15
GEA Delbag H14/U15 HEPA filters - here packages of folds are cast airtight in aluminium frames and are provided with handle guard on the pure-air side
Application example:
for systems with very high standards in air purity; in supply air ceilings and walls of fullyequipped clean rooms with turbulence-free (laminar flow) replacement ventilation, for
workbenches and workroom cabins
Special features:
great mechanical stability, metal-free separation of folds, pure-air side laminator on
downstream air flow
Areas of application:
electronics or microelectronics, production of semiconductors, health care, chemical,
pharmaceutical industries, microbiology
Pressure drop diagram:
Pressure drop [Pa]
200
U15
150
100
H14
50
0
0
20
40
60
80
100
Volume flow [%]
Form of delivery:
GEA Delbag H14/U15 HEPA and ULPA filters
Type A14FA installation depth 69 mm - *Model with a
standard seal – other seals and handle guard on request
Size W/H
[mm]
Air flow rate
[m³/h]
Filter surface
[m²]
Approx. weight
[kg]
Type A15FA installation depth 69 mm - *Model with a
standard seal – other seals and handle guard on request
Air flow rate
[m³/h]
Filter surface
[m²]
Approx. weight
[kg]
305/305
150
2.6
1.6
150
2.6
1.6
305/610
300
5.3
2.9
300
5.3
2.9
457/457
340
5.9
3.0
340
5.9
3.0
610/610
600
10.6
4.7
600
10.6
4.7
610/915
900
15.9
6.7
900
15.9
6.7
610/1220
1200
21.2
8.7
1200
21.2
8.7
* Sizes 78, 90, and 117 are available on request
50
PR-2009-0099-GB • Subject to modifications • Status K12-02/2013
Activated Carbon Filter
GEA Air Filters
Activated Carbon, Loose
Activated carbon, loose
Technical data/
form of delivery/
order numbers:
Grain
size
Weight
[kg/bag]
Density
[g/l]
Special
treatment
AKOLIT-A1
25
490
no
AKOLIT-A2
25
490
no
AKOLIT-A3
25
460
no
Application
for example
minimum
contact time
Order
number
0.1–0.2 s
00 01 294
0.1–0.2 s
00 01 581
0.1–0.2 s
00 01 793
0.2 s
00 03 572
0.25 s
20 02 410
0.25 s
20 01 606
Odours
AKOLIT-C1
25
640
yes
AKOLIT-CG1
25
560
yes
Hydrocarbons
Solvents
sulphuric acid
hydrochloric acid
sulphur dioxide
hydrogen fluoride
Radioactive gas types
AKOLIT-CG1,5
Grain size
1
2
3
8,0
520
yes
= Rods with diameter1 mm
= Rods with diameter2 mm
= Rods with diameter3 mm
Plate Elemenet AK-20 consists of MDF-frame with a V-shaped arranged and airtight
cast activated carbon plate
Application example:
if saturated - activated carbon filter must be replaced
Areas of application:
EBE duct filter
Specifications:
Form of delivery/
order numbers:
filter plate element
dimensions W/H/D + gasket
[mm]
AK-20
305/610/292 + 8
AK-20
610/610/292 + 8
Flow rate
[m³/h]
625
1250
Pressure drop
[Pa]
50
50
Contact time
[s]
0.15
0.15
Layer thickness
[mm]
20
20
Activated carbon volume
[l]
25
50
Weight
[kg]
approx. 22
approx. 37
AK-20
Size
Order number
Akolit-A1
305/610/292 + 8
20 01 202
Packaging unit 1
610/610/292 + 8
60 22 581
PR-2009-0099-GB • Subject to modifications • Status K12-02/2013
51
Activated Carbon Filter
GEA Air Filters
Activated Carbon Cartridge 705/706/707
Activated-carbon cartridges 705/706/707 consist of perforated, concentric synthetic
cylinders; the interstices of the cartridge are filled with activated carbon; expansion
adjustment ring in each cartridge ensures that the cartridges can be used in any
arrangement and that no air leakages occur allowing in such a way dust air to escape;
carbon content can be replaced; mounting is performed as plug or screw connection
Application example:
adsorption of toxic gas pollutants
Special features:
different activated carbon types; regeneration is possible
Areas of application:
odours, hydrocarbons, solvents
Pressure drop diagram:
Pressure drop [Pa]
1600
1200
707
800
400
0
705/706
0
25
50
75
100
125
Air flow rate [m³/h]
Specifications:
Activated carbon cartridges
Activated carbon type
706
707
AKOLIT-A
AKOLIT-A
AKOLIT-A
Diameter/height
[mm]
119/291
119/291
119/291
Max. operating temperature
[°C]
40
40
40
Max. rel. air humidity
[%]
70
70
70
Activated carbon volume
[i]
1,7
1,7
2,0
Layer thickness
[mm]
22
22
31
Flange diameter
[mm]
67.1
67.1
38.0
Screw connection
Plug connection
Screw connection
Connection type
Form of delivery/
order numbers:
705
Activated carbon
cartridge
Activated
carbon type
packagingunits [#]
Empty weight
[kg]
Order
number
705
Akolit-A2
25
0.2
60 50 331
706
Akolit-A2
25
0.2
60 50 431
707
Akolit-A2
25
0.2
00 37 109
Intake capacity and degree of filtration of activated carbon filters depend on gas composition and
concentration as well as contact period of gas molecules with activated carbon.
Maximum allowed air humidity 70 %, max. temperature 40 °C, minimum contact period depending on application 0,05 s to 1,0 s, pre-filtration is necessary, required filter class F7 (DIN EN 779).
Activated carbon cartridges 706 and 707 are also regenerable. In this case a used activated carbon cartridge is opened, cleared, cleaned, recharged with unused activated carbon, closed and
is available in regenerated form. Used activated carbon is then recycled by an authorized and
certified waste management company.
52
PR-2009-0099-GB • Subject to modifications • Status K12-02/2013
Activated Carbon Filter
GEA Air Filters
Activated Carbon Cartridge 708/709
Activated-carbon cartridges 708/709 consist of perforated steel sheet or stainless
steel; the interstices of the cartridge are filled with activated carbon; expansion adjustment ring in each cartridge ensures that the cartridges can be used in any arrangement
and that no air leakages occur allowing in such a way dust air to escape; carbon content can be replaced; connection is performed via 3-point bayonet
Application example:
adsorption of toxic gas pollutants
Special features:
different activated carbon types; regeneration is possible
Areas of application:
odours, hydrocarbons, solvents
Contact
period [s]
Pressure drop [Pa]
Pressure drop diagram:
air flow volume[m³/h]
grain size 3.0 mm
Specifications:
Activated carbon cartridge
Activated carbon type
708
709
AKOLIT-A
AKOLIT-A
Application:
CKG holding frame
Diameter/height
[mm]
140/600
Max. operating temperature
[°C]
40
40
Max. rel. air humidity
[%]
70
70
Activated carbon volume
[i]
4.0
5.3
Layer thickness
[mm]
26
26
3-point bayonet
3-point bayonet
Connection type
Form of delivery/
order numbers:
140/450
Activated
carbon
cartridge
Activated
carbon type
packagingunits
[#]
Empty
weight
[kg]
Order
number
AKOLIT-A3 galvanized steel
8
1.6
00 03 499
708
AKOLIT-A3 stainless steel
8
1.6
20 01 418
AKOLIT-A3 galvanized steel
8
2.0
10 37 410
AKOLIT-A3 stainless steel
8
2.0
10 37 415
709
Intake capacity and degree of filtration of activated carbon filters depend on gas composition and
concentration as well as contact period of gas molecules with activated carbon.
Maximum allowed air humidity 70 %, max. temperature 40 °C, minimum contact period depending on application 0,05 s to 1,0 s, pre-filtration is necessary, required filter class F7 (DIN EN 779).
Activated carbon cartridges 708 and 709 are also regenerable. In this case a used activated carbon cartridge is opened, cleared, cleaned, recharged with unused activated carbon, closed and
is available in regenerated form. Used activated carbon is then recycled by an authorized and
certified waste management company.
PR-2009-0099-GB • Subject to modifications • Status K12-02/2013
53
Activated Carbon Filter
GEA Air Filters
CKG holding frame
CKG holding frame – individual, exchangeable activated carbon bayonet-fitted type
708/709 cartridges are used in frames made of galvanized or stainless steel
Special features: the cartridges can be individually replaced and have a 3-point bayonet-type connection
Areas of application:
frames are used in duct air filters EBE with 472 + 620 mm installation depth (on
request), or as wall frames
NOTE!
Large cartridges are only available for CKG-2 and CKG-3 frames!
Technical data/
order numbers:
CKG holding frame
CKG-2-V-708-03
CKG-3-V-708-03
CKG-6-V-708-03
304/304/70
304/609/70
609/609/70 *
Unit size
[mm]
Number of cartridges
[quantity]
4
8
16
Activated carbon volume
[l]
16
32
64
Packaging unit
[quantity]
1
1
1
Galvanized steel frame (V)
10 39 837
10 39 323
10 39 321
Stainless steel frame (N)
10 39 321
10 32 720
10 32 719
Order number
* only for 708
54
PR-2009-0099-GB • Subject to modifications • Status K12-02/2013
Round Air Filters
GEA Air Filters
Overview
These round filters are used to purify the intake air for internal-combustion engines and
for fans. Various structural designs, sizes, and filter media are available, depending on
the purpose of use. Weather-protection hoods are available for outdoor applications.
Explanation of specifications for all round air filters
Description
Filter medium
Wetting
DAH
High performance (HL)
wetted
DAC
FIBROIDELASTIC-30
unwetted
DBH
High performance (HL)
wetted
DBA
FIBROIDELASTOV-20 / ACELAN
unwetted
DBC
FIBROIDELASTIC-30
unwetted
DBV
FIBROIDELASTOV-40
unwetted
Pressure difference for types DAH, DBC, DBH, DBV, DAC
Pressure drop [Pa]
Pressure drop [Pa]
DBA type
Air flow rate [m³/h]
Air flow rate [m³/h]
Size
DAH type
1 0
85
170
250
340
420
2 0
145
290
440
580
730
3 0
260
520
780
1040
1300
Size
DBC, DBH, DBV types
1 0
200
400
600
800
1000
2 0
400
800
1200
1600
2000
3 0
700
1400
2100
2800
3500
4 0
1000
2000
3000
4000
5000
5 0
1400
2800
4200
5600
7000
1 0
45
90
130
180
220
2 0
100
200
300
400
500
3 0
200
400
600
800
1000
Size
DAC type
PR-2009-0099-GB • Subject to modifications • Status K12-02/2013
55
Round Air Filters
GEA Air Filters
DAH
DAH round air filters
and weather-protection hoods are manufactured of painted steel (RAL 5001); metal filter cartridges (HL high performance model) are used as a filter medium; round air filters
DA for clamping are supplied with a slotted fitting with a clip
Application example:
for cleaning intake air of internal-combustion motors, fans and compressors
Special feature:
slotted fitting with a clip
Areas of application:
industrial facilities requiring process air treatment, heavy industry, cement industry,
sewage treatment plants, water treatments plants
Air flow rate [m³/h]
Pressure drop diagram:
Weatherproof hood
(optional)
Pressure drop [Pa]
Round air filter DAH
Technical data/
form of delivery/
order numbers:
DAH1-70
DAH1-100
DAH1-120
G2
G2
G2
Round air filter DAH
Filter class
[EN 779]
Diameter/height
[mm]
130/140
180/155
180/230
Nominal air flow rate
[m³/h]
250
440
780
Initial pressure drop
[Pa]
100
100
100
Flange diameter
[mm]
70
100
120
Weight
[kg]
0.9
1.6
2.3
Multi-stage model
no
no
no
Wetting
yes
yes
yes
Packaging unit
[quantity]
Order number
1
20 00 333
20 00 339
20 00 340
180/145
225/160
225/235
0.6
1.0
1.3
DAH weatherproof hood
Diameter/height
[mm]
Weight
[kg]
Packaging unit
[quantity]
1
20 00 631
Order number
20 00 204
20 00 632
Wetting agent VISCINOL A 30 – 15 to + 45 °C 20 liter container
Net weight
Order number
56
[kg/l]
0.9
20 00 365
PR-2009-0099-GB • Subject to modifications • Status K12-02/2013
Round Air Filters
GEA Air Filters
DBH/DBA/DBV
DBH/DBA/DBV round air filter – the cartridge can be exchanged, and can be used
again after being cleaned and wetted; the filter medium can be exchanged and can be
used again after cleaning (except for F5).
Specifications:
Round air filter, multi-stage design,
with and without wetting
Size 1
Size 2
Size 3
Size 4
Size 5
[mm]
240/255
360/305
360/505
500/505
500/705
Cartridge height h
[mm]
150
200
200
200
200
Number of cartridges
[quantity]
1
1
2
2
3
Filter weight
[kg]
8.5
15.5
24.5
40.5
51.0
Weight per cartridge set
[kg]
3.0
4.0
8.0
11.0
17.0
150/670
200/1050
200/1050
200/1500
300/1500
1
1
2
2
2
Diameter/height
DBH HL wetted
filter class (DIN EN 779) G2
DBV FIBROIDELASTOV-40
filter class (DIN EN 779) G4
Filter layer size
[mm]
Number of cartridges/filter layer
[quantity]
Filter weight
[kg]
8.0
12.0
19.0
26.0
36.0
Weight
[kg]
0.7
1.2
1.2
2.4
2.4
DBA 2-stage FIBROIDELASTOV-20/ACELAN
Nominal width:
Number of holes n
Filter layer size
[mm]
Number of cartridges/filter layer
[quantity]
Filter weight
Weight per package
200/1050
200/1050
200/1500
300/1500
1
1
2
2
2
[kg]
8.7
13.2
20.2
28.4
38.4
[kg]
1.4
2.4
2.4
4.8
4.8
Nominal width NW
Flange for DB
125
200
250
350
400
Durchmesser
D
[mm]
240
320
375
490
540
Bolt circuit diameter
k
[mm]
200
280
335
445
495
Number of bolt holes
n
8
8
12
12
16
Hole diameter
d
[mm]
18
18
18
23
23
Reduced thickness
b
[mm]
8
8
8
12
12
100
150
200
250
300
DIN 2641 for PN 6
Loose flange
Filter class (DIN EN 779) M5
150/670
DIN 2642 for PN 10
Durchmesser
D
[mm]
220
285
340
395
445
[mm]
180
240
295
350
400
8
8
8
12
12
Bolt circuit diameter
k
Number of bolt holes
n
Hole diameter
d
[mm]
18
23
23
23
23
Reduced thickness
b
[mm]
8
8
8
8
12
PR-2009-0099-GB • Subject to modifications • Status K12-02/2013
57
Round Air Filters
GEA Air Filters
DBH/DBA/DBV
DBH
Round air filter DBH (G2) High performance HL
DBA
Round air filter DBA (F5) FIBROIDELASTOV-20/ACELAN
DBV
Round air filter DBV (G4) FIBROIDELASTOV-40
-
100
/
2642
Flange DIN
1
Flange NW
DBH
Size
Order sample:
Type
Unit type code:
Diameter/height
1
240/255
2
360/305
3
360/505
4
500/505
5
500/705
Flange nominal width according to table „Nominal width“ on Page
DIN 2641 for PN 6
DIN 2642 for PN 10
Form of delivery
order numbers:
DBH (G2)
High performance
HL
DBA (M5)
FIBROIDELASTOV-20/ACELAN
DBV (G4)
FIBROIDELASTOV-40
1-100/2642
20 02 007
20 15 021
20 01 469
1-125/2641
20 01 145
20 00 627
20 15 024
2-150/2642
20 00 723
20 00 580
20 02 912
2-200/2641
20 00 581
20 00 628
20 01 531
3-200/2642
20 15 028
20 15 022
20 01 144
3-250/2641
20 15 029
20 00 958
20 15 025
4-250/2642
20 15 030
20 01 072
20 03 548
4-350/2641
20 01 541
20 00 629
20 15 026
5-300/2642
20 04 659
20 15 023
20 00 671
5-400/2641
20 15 031
20 02 261
20 01 880
1
1
1
Round air filter
colour RAL 5001
Packaging unit
Order numbers
DBH accessories:
Size 1
Spare cartridges
Size 2
DBH high performance HL
Size 3
Size 4
Size 5
filter class (DIN EN 779) G2
Quantity/size
1
1
2
2
3
Diameter/height
[mm]
240/150
360/200
360/200
500/200
500/200
Weight per unit
[kg]
3.0
4.0
4.0
5.5
5.5
Order number
20 00 501
20 00 500
20 00 502
Wetting agent VISCINOL A 30; – 15 to + 45 °C 20 liter container
Net weight
Order number
58
[kg/l]
0.9
20 00 365
PR-2009-0099-GB • Subject to modifications • Status K12-02/2013
Round Air Filters
GEA Air Filters
DBH/DBA/DBV
Order numbers
DBA accessories:
Spare
Width/length
[mm]
Weight per unit
[kg]
Packaging unit
[quantity]
150/670
200/1050
Size 3
Size 4
Size 5
200/1050
200/1050
300/1050
0.7
1.2
1.2
2.4
2.4
2
2
Filter class (DIN EN 779) M5
10
1
1
2
DB, FIBROIDELASTOV-20
order number
20 00 208
20 00 205
20 00 206
20 00 207
DB, ACELAN
order number
20 00 213
20 00 214
20 00 215
20 00 216
Size 4
Size 5
Size 1
Spare
Size 2
DBA FIBROIDELASTOV-40
Width/length
[mm]
Weight per unit
[kg]
Packaging unit
[quantity]
200/1050
200/1050
200/1050
300/1050
0.7
1.2
1.2
2.4
2.4
10
Quantity/size
Diameter/height
[mm]
Weight per unit
[kg]
Packaging unit
[quantity]
1
1
20 00 209
Weather protection hood
DBH/DBA/DBV
colour RAL 5001
PR-2009-0099-GB • Subject to modifications • Status K12-02/2013
150/670
1
Order number
Order number
Size 3
Filter class (DIN EN 779) G4
Quantity/size
Order number
Weatherproof hood
DBH/DBA/DBV:
Size 2
DBA FIBROIDELASTOV-20/ACELAN
Quantity/size
Order numbers
DBV accessories:
Size 1
2
20 00 210
2
2
20 00 211
20 00 212
Size 1
Size 2
Size 3
Size 4
Size 5
1
1
2
2
3
310/295
430/350
430/550
575/560
575/760
3.0
4.0
7.0
9.0
14.0
20 00 638
20 00 639
1
20 00 635
20 00 636
20 00 636
59
Round Air Filters
GEA Air Filters
DAC/DBC
DAC/DBC round air filters are made of immersion painted steel (RAL 5001); ring
packs (FIBROIDELASTIC-30) are used as a filter medium; round air filters DA for
clamping are supplied with a slotted fitting with clamps
Application example:
for cleaning intake air of internal-combustion motors, fans and compressors
Special feature:
slotted fitting with a clip
Areas of application:
industrial facilities requiring process air treatment, heavy industry, cement industry,
sewage treatment plants, water treatments plants
Pressure drop diagram:
Structure of round air filter
DAC
Air flow rate [m³/h]
Fastening nuts
Disk
Weather protection
hood (optional)
Cover
Pressure drop [Pa]
Filter ring
FIBROIDELASTIC
Cartridge core
Connection
fitting
Technical data/
form of delivery/
order numbers DAC:
DAC1-52
DAC2-80
DAC3-110
G2
G2
G2
180/250
Round air filter DAC, single stage model, without wetting
Filter class
[EN 779]
Diameter/height
[mm]
180/120
180/180
Nominal air flow rate
[m³/h]
130
300
600
Initial pressure drop
[Pa]
100
100
100
Flange diameter d
[mm]
52
80
110
Ring pack height h
[mm]
60
120
190
Filter weight
[kg]
1.8
2.0
2.3
Packaging unit
[quantity]
Order number
1
20 00 494
20 00 491
20 00 634
225/125
225/185
225/255
0.7
1.0
1.5
Weatherproof hood DAC
Diameter/height
[mm]
Weight
[kg]
Packaging unit
[quantity]
Order number
1
20 00 633
20 00 204
20 00 632
Filter ring FIBROIDELASTIC-30
Diameter/height
[mm]
180/60
180/120
180/190
Weight
[kg/l]
0.15
0.3
0.4
Packaging unit
[quantity]
Order number
60
240
120
60
20 00 103
20 00 104
20 00 105
PR-2009-0099-GB • Subject to modifications • Status K12-02/2013
Round Air Filters
GEA Air Filters
DAC/DBC
Technical data DBC:
Nominal width:
Number of holes n
Filter class (DIN EN 779) G2
DBC, FIBROIDELASTIC-30
Ring pack height
[mm]
150
200
400
400
600
Filter weight
[kg]
6.0
8.0
12.0
17.0
21.0
Weight per package
[kg]
0.4
0.8
1.6
2.2
3.3
Nominal width NW
Flange for DB
DIN 2641 for PN 6
125
200
250
350
400
Durchmesser
D
[mm]
240
320
375
490
540
Bolt circuit diameter
k
[mm]
200
280
335
445
495
Number of bolt holes
n
8
8
12
12
16
Hole diameter
d
[mm]
18
18
18
23
23
Reduced thickness
b
[mm]
8
8
8
12
12
100
150
200
250
300
DIN 2642 for PN 10
Loose flange
[mm]
220
285
340
395
445
Bolt circuit diameter
k
[mm]
180
240
295
350
400
Number of bolt holes
n
8
8
8
12
12
Hole diameter
d
[mm]
18
23
23
23
23
Reduced thickness
b
[mm]
8
8
8
8
12
DBC
DBC
1
-
100
/
2642
Flange DIN
Order sample:
Flange NW
Product type code DBC:
Size
D
Type
Durchmesser
Round air filter DBC (G2) FIBROIDELASTIC-30
Diameter/height
1
240/255
2
360/305
3
360/505
4
500/505
5
500/705
Flange nominal width according to
table „Nominal width“ see above
DIN 2641 for PN 6
DIN 2642 for PN 10
PR-2009-0099-GB • Subject to modifications • Status K12-02/2013
61
Round Air Filters
GEA Air Filters
DAC/DBC
Form of delivery/
order numbers DBC:
Round air filter colour RAL 5001
DBC (G2) FIBROIDELASTIC-30
DBC 1-100/2642
20 15 021
DBC 1-125/2641
20 00 627
DBC 2-150/2642
20 00 580
DBC 2-200/2641
20 00 628
DBC 3-200/2642
20 15 022
DBC 3-250/2641
20 00 958
DBC 4-250/2642
20 01 072
DBC 4-350/2641
20 00 629
DBC 5-300/2642
20 15 023
DBC 5-4
20 02 261
Packaging unit
Order numbers
DBC accessories:
1
Spare filter ring DBC
Size 2
1
1
1
1
1
DB, FIBROIDELASTIC-30
Size 3
Size 4
Size 5
Filter class (DIN EN 779) G2
Quantity/size
Diameter/height
[mm]
240/150
360/200
360/400
500/400
500/600
Weight per unit
[kg]
0.4
0.8
1.6
2.2
3.3
Packaging unit
[quantity]
45
20
20
15
8
20 00 106
20 00 107
20 00 108
20 00 109
20 00 110
Order number
62
Size 1
PR-2009-0099-GB • Subject to modifications • Status K12-02/2013
Glove Box Filter
GEA Air Filters
DKA/DKB
DKA/DKB glove-box filters are high-efficiency submicron particulate air filters
(HEPA) in encapsulated form (model types DKA and DKB); the filters can be installed
on the air-intake or the air-outlet sides, maximum pressure load for the cartridge casing
makes up 5.000 Pa
Application example:
filtration of dust and gas pollutants from industrial process and atmospheric air
Special features:
filtration meeting highest standards (HEPA); filters can be installed on the air-intake or
the air-outlet sides; encapsulated form
Areas of application:
disinfecting and sterilisation equipment, insulating boxes, glove boxes, laboratory and
photo laboratory equipment, ventilation of drink water containers, fermentation and
yeast processing plants
DKB
M 62x2,5
M 62x2,5
Ø 53
Ø 53
Ø 140
22
194
150
172
22
DKA
22
Glove box filter
Ø 140
Technical data/
form of delivery/
order numbers:
Glove Box Filter
DKA
DKB
H13
H13
Filter class (HEPA)
[EN 1822]
Diameter/height
[mm]
140/172
140/194
Nominal air flow rate
[m³/h]
25
25
Initial pressure drop
[Pa]
115
140
Maximum allowed pressure
[Pa]
drop
1000
1000
> 99.95
> 99.95
Max. operating temperature [°C]
60
60
Max. rel. air humidity
[%]
100
100
Connection fitting
[quantity]
1
2
M62x2.5
M62x2.5
20 00 711
20 00 712
Filtration efficiency
Connection
Order number
PR-2009-0099-GB • Subject to modifications • Status K12-02/2013
[%]
63
Glove Box Filter
GEA Air Filters
DKC/DKD
DKC/DKD glove-box filters are high-efficiency submicron particulate air filters
(HEPA) in encapsulated form; the filters can be installed on the air-intake or the airoutlet sides, maximum pressure load for the cartridge casing makes up 5,000 Pa,
these filters can combined with gas sorption filters using activated-carbon cartridges
that can be installed only vertically
Application example:
filtration of dust and gas pollutants from industrial process and atmospheric air
Special features:
filtration that meets highest standards (HEPA); filters can be installed on the air-intake
or the air-outlet sides; encapsulated form, combination with activated-carbon filters
Areas of application:
disinfecting and sterilisation equipment, insulating boxes, glove boxes, laboratory and
photo laboratory equipment, ventilation of drink water containers, fermentation and
yeast processing plants
Glove box filter
Technical data/
form of delivery/
order numbers:
DKC
Glove Box Filter
DKC
DKD
H13 and activated carbon
H13 and activated carbon
Filter class (HEPA)
[EN 1822]
Diameter/height
[mm]
140/257
140/279
Nominal air flow rate
[m³/h]
25
25
Initial pressure drop
[Pa]
815
840
Maximum allowed pressure
[Pa]
drop
1700
1700
> 99.95
> 99.95
Max. operating temperature [°C]
40
40
Max. rel. air humidity
[%]
70
70
Connection fitting
[quantity]
1
2
M62x2.5
M62x2.5
AKOLIT-A1
20 02 396
20 01 931
AKOLIT-CG
20 04 289
20 01 930
Filtration efficiency
[%]
Connection
Order number
depending on activated
carbon type
64
DKD
PR-2009-0099-GB • Subject to modifications • Status K12-02/2013
Filter Frames for Wall or Ceiling Installation
GEA Air Filters
CDD Wall Frame
CDD wall frames are made of galvanized or stainless steel; 4 spring clamps hold the
air filters to the frame; the frames can be bolted together to form a filter wall.
CDD wall frames with reinforced edges are made of galvanized or stainless steel;
bolted edges enable to prevent air leakage and ensure an enhanced tightness and
frame fit. 4 spring clamps hold the air filters to the frame; the frames can be bolted
together to form a filter wall.
Technical data/
order numbers:
Filter frame for wall or ceiling installation CDD/CDD-VA
Unit size
[mm]
304/304
304/609
Filter class (depending on complement items installed)
507/609
609/609
G2 to F9
Filter size
[mm]
287/287
287/592
490/592
592/592
Installation depth
[mm]
72
72
72
72
Weight/each
[kg]
1.5
1.6
2.1
2.2
CDD order number
Range of terminals 20-25
[mm]
10 08 381
62 06 744
62 07 144
62 07 544
Range of terminals 45-50
[mm]
21 00 004
21 00 010
10 48 535
10 44 360
Range of terminals 20-25
[mm]
10 14 432
62 06 844
62 07 244
62 07 644
Range of terminals 45-50
[mm]
21 00 001
21 00 007
21 00 013
20 47 925
CDD-VA order number
CDD-VA order number for frame with reinforced edges
Filter class (depending on
complement items installed)
E10 to H14
Range of terminals 45-50
[mm]
On request
On request
On request
On request
Range of terminals 20-25
[mm]
On request
On request
On request
On request
PR-2009-0099-GB • Subject to modifications • Status K12-02/2013
65
Filter Frames for Wall or Ceiling Installation
GEA Air Filters
CGF Ceiling Air Outlets
CGF ceiling air outlets are made of powder-coated sheet steel (colour RAL 9010) and
are equipped with the following:
– shut-off flap is installed in the intake-air fitting at the side, closes airtight
(as per DIN 1946, Part 4)
– The shut-off flap is operated manually or electrically (actuator 230 V or 24 V can be
selected)
– Check device for filter airtight fit of recommended HEPA filter element with a Ushaped profile seal
– integrated pressure-gauge connection for monitoring pressure drop
– fitting for oil-mist passage
– sealing of filters using four non-slip clamping elements
– Connection of different air distributing outlets by using central or 4-point locks
Application example:
CGF ceiling air outlets with integrated HEPA filters operate as last filter stage in efficient filtration of particle-shaped air pollutants of all types, including microorganisms
Special feature:
compact shape; high-quality and high-value model; high operating safety; using different air distributors is possible; can be integrated in DDC-controlled building management system (in a model with an actuator)
Areas of application:
AHU systems in hospitals according to DIN 1946 Part 4 for Indoor Class I, operating
rooms Type B and auxiliary room in operating area, intensive care units and emergency room, clean rooms, pharmaceutical industry, genetic technology, microbiology,
food product industry, production of semiconductors
C
Hose or
pipe connection
L1
Ø20
Connection for
checking airtight
fit
20
DN
H
h
155
B
K
Connection for pressure
drop measurement
Technical data/
order numbers:
T
K
L2
Manual actuator for
shut-off flap
Air diffuser
Ceiling Air Outlet
50
CGF 318-1 / 1
CGF 470-1 / 1
CGF 587-1 / 1
CGF 623-1 / 1
305/305/78
+7
457/457/78
+7
575/575/78
+7
610/610/78
+7
[kg]
6.4
10.7
15.5
16.4
Installation depth
[mm]
345
380
435
435
Packaging unit
[unit
s]
1
1
1
1
with shut off flap
10 13 596
10 13 691
10 31 377
10 13 692
without shut off flap
10 17 639
10 18 526
10 31 378
10 13 694
Filter size W/H/D
seal
[mm]
for filter class
Weight
E10 to H14
Order number
Order numbers
accessories:
350/350
500/500
623/623
650/650
Twist outlet 358 steel RAL 9010
00 05 414
10 09 824
10 13 618
10 09 825
Ventilation grille aluminium, discharge on 4 sides
10 13 597
10 09 822
10 13 619
10 09 823
Ventilation grille steel RAL 9010, discharge on 4
sides
10 13 611
10 13 609
10 13 620
10 13 610
1
1
1
1
Air diffuser with central mounting W/H
Packaging unit
66
PR-2009-0099-GB • Subject to modifications • Status K12-02/2013
Filter Frames for Wall or Ceiling Installation
GEA Air Filters
CKC Wall Frame
CKC wall frame is especially developed for holding HEPA filters; five different filter
sizes are available; filter media of different installation depth can be used (78, 150, 292
mm); profile frame is gastight welded and is either made of galvanized steel or stainless steel 1.4301 (material can be selected); four supporting brackets with a centring
function enable fast and safe sealing of a HEPA filter on the sealing surface; all frames
are equipped with a monitoring device for checking seat tightness of HEPA filter
Application example:
climate control and air handling units with highest standards in air purity
Special features:
easy assembly of a complete wall frame system; different frame sizes in Euro grid size;
combination of complete-size and half-size units is possible; easy mounting and disassembly of HEPA filter elements; high operating safety
For checking airtight fit filters with a U-shaped profile seal are required.
Areas of application:
pharmaceutical industry and health care, chemical and clean room technology
Specifications:
Accessories:
CKC Wall Frame
Size 2
Size 3
Size 6
Filter size
[mm]
290/290/292
290/595/292
595/595/292
Thickness/depth/length
[mm]
355
355
355
Width/height (nominal)
[mm]
305/305
305/610
610/610
Angular steel mounting frame
mounting set
PR-2009-0099-GB • Subject to modifications • Status K12-02/2013
67
Filter Frames for Wall or Ceiling Installation
GEA Air Filters
ELA Filter Casing
ELA filter casing has a stable and light construction made of steel sheet and supplied
as galvanized model; individual modules are assembled through clinch connections to
casing sizes of 385 x 690 mm to 1.910 x 690 mm; undrilled run-around flange (40 mm)
enables flexible adjustment to upstream and/or downstream duct components; filters
are fixed in an integrated CDD frame; the casing is designed for intake and pressureside operation (max. 1.000 Pa); an easily removable service door on side enables filter
replacement in airflow direction from left or right (can be selected); doors are fixed by
four star bolts; the modular design enables casing combinations up to three vertical
levels
Application example:
for all types of climate control and air handling units that are designed for installation
of pleated filters of series MULTISACK and filter elements of series MULTIFORM; filter
media of classes G3 - F9
Special features:
modular construction; stable light design with galvanized sheet steel; filter replacement
in air flow direction can be selected on left or right side (from size 2/2 filter change on
both sides is necessary); run-around, undrilled flange frame; casing is designed for
intake and pressure-side operation (max. 1,000 Pa)
Areas of application:
standard HVAC applications with a filtration function in all air handling units
Star formed screws
Clean air
Untreated air
Specifications:
Accessories:
68
ELA Filter Casing
ELA 05/10
ELA 10/10
Width/height
[mm]
385/690
690/690
Thickness/depth/length
[mm]
700
700
Filter size
[mm]
287/592
592/592
Pressure- drop measuring devices
PR-2009-0099-GB • Subject to modifications • Status K12-02/2013
Filter Frames for Wall or Ceiling Installation
GEA Air Filters
EBE Casing
EBE casings have a stable and light construction made of galvanized steel sheet or
stainless steel (1.4571 or 1.4301); because of modular design - a combination with different unit sizes and use of different filter media with different filter sizes is possible;
use of filter media of classes G2 - H13 is also possible; several filter stages can be
combined straight through; four threaded rods with clamping nuts are used to secure
HEPA filters, filter elements and activated carbon filters; an additional holding frame is
required for MULTIFORM filter elements and activated carbon cartridges; MULTISACK
bag filters are secured with an integrated CDD frame; easy open and close functions
of airtight service cover with a star grip
Application example:
for all HVAC and air handling applications
Special features:
airtight design thanks to soldered or welded profile connections; suction and pressureside operation (max. 2000 Pa); wide-range accessories: pressure drop measuring
devices, connection fittings, contact grille etc.; combination of duct air filters of full-size
and half-size units for different unit sizes; assembly of vertical casing units or securing
of transition fittings is done through prefabricated bolt connection (rivet nuts of size
M8); drilled flange frame (M8) enables easy and quick vertical connection
Optionally available as an explosion-proof filter casing.
Areas of application:
cleaning of supply air for protection of corrosion-risk electronic components, control
centres and data processing units, air filtration in industrial processes, air cleaning for
protection of valuable items in libraries and museums; ventilation of drinking water
processing plants and containers, filtration of exhaust air to comply with emission
standards, safety filter in de-dusting facilities, combined filter for filtration of coarse, fine
dust and odour pollutants, e.g. kitchen exhaust, multi-stage adsorption filter
Star formed screws
Untreated air
Clean air
Air flow cross section
Untreated air
Connection
flange frame,
35 mm run-around
Specifications:
EBE filter casing
Width/height
[mm]
Thickness/depth/length [mm]
Filter size
[mm]
PR-2009-0099-GB • Subject to modifications • Status K12-02/2013
Clean air
EBE 05/10
EBE 10/10
445/750
750/750
700
700
305/610
610/610
69
Notes
70
GEA Air Filters
PR-2009-0099-GB • Subject to modifications • Status K12-02/2013
GEA Air Filters
PR-2009-0099-GB • Subject to modifications • Status K12-02/2013
Notes
71
We live our values.
Excellence r Passion r Integrity r Responsibility r)'#XGTUKV[
GEA Group is a global engineering company with multi-billion euro sales and operations in more than
|EQWPVTKGU(QWPFGFKPVJGEQORCP[KUQPGQHVJGNCTIGUVRTQXKFGTUQHKPPQXCVKXGGSWKROGPVCPF
process technology. GEA Group is listed in the STOXX® Europe 600 Index.
www.gea-airtreatment.com