LectroCount LCR-II ™ Menu Map PRINT Position 200.0 STOP Position < Delivery Total SELECT PROD 1 LCR-II Selector Switch Plate 200.0 < Delivery Total PROD 2 SELECT RUN Position INCREASE SELECT PROD 1 SELECT INCREASE < Product No. PROD 3 INCREASE INCREASE PROD 2 200.0 PROD 4 < Delivery Total INCREASE INCREASE INCREASE SELECT PROD 3 F 70.0 < Flow Rate INCREASE k98765 SELECT SELECT SELECT < Temperature INCREASE 00200.0 < Preset Amount IN- L5432.0 PROD 4 38.7 o F < 10 Digit Totalizer (leading digits) < Totalizer (trailing digits) SELECT SELECT 12:30:00 < Time of Day INCREASE SELECT P12345 SELECT 11:30:00 SELECT < Password If system is Locked, a password will need to be entered. < Time of Day Adjust- PROCEDURE FOR MAKING A PRESET DELIVERY SHIFT PRINT Position 200.0 < Delivery Total CALIBRATION Position 098.023 PROD 1 SELECT 1. 2. 3. 4. < k-Factor PROD 1 INCREASE SELECT INCREASE INCREASE PROD 2 PROD 2 INCREASE “If Delivery is Active” INCREASE PROD 3 PROD 3 INCREASE INCREASE PROD 4 PROD 4 INCREASE INCREASE Turn the Selector Switch to the STOP position. Press the SELECT button. The display will show Prod #. Press INCREASE to select the product desired for delivery. Press SELECT when the correct Prod # is displayed. This will advance to the preset display. 5. The left most digit in the display will be flashing. Press INCREASE to set the value of the first digit. When the value is chosen, press SELECT. The next digit to the right will flash. If the digit does not need to be changed, press SELECT to move one digit to the right. 6. Press INCREASE to change the value of the second digit. When the value is chosen, press SELECT. 7. Continue in this manner until all digit positions have been selected. After the last digit is selected, the display will return to the first screen, which is the Delivery Total. Or, switch to RUN when the desired amount is shown. 8. Turn the Selector Switch to RUN. DO NOT OPEN THE HOSE NOZZLE. When the display stops counting, turn the Selector Switch back to STOP. This step is necessary to allow for hose stuffing. If less than 1 Gallon was recorded, the display will reset to 0 and no ticket will be printed. 9. Turn the Selector Switch to RUN. The display will reset and the hose nozzle should now be opened to start the delivery. When the preset has been reached, the valve will close. 10. Turn the Selector Switch to the PRINT position to print out a delivery ticket. INCREASE k98765 < 10 Digit Totalizer F 70.0 < Flow Rate PROCEDURE FOR PRINTING A DIAGNOSTIC TICKET SELECT SELECT 1. 2. 3. INCREASE 27.2 o F L5432.0 < Totalizer (trailing digits) < Temperature SELECT Put a blank ticket in the Epson Printer. Turn the Selector Switch to SHIFT PRINT for less than 2 seconds. Turn the Selector Switch back to PRINT and a Diagnostic ticket will be printed. SELECT 102.965 < k-Factor PROCEDURE FOR PRINTING A SHIFT TICKET SELECT 1. 2. Put a blank ticket in the Epson Printer. Turn the Selector Switch to SHIFT PRINT for more than 2 seconds.
© Copyright 2026 Paperzz