LCRII Menu Map

LectroCount LCR-II ™ Menu Map
PRINT Position
200.0
STOP Position
< Delivery Total
SELECT
PROD 1
LCR-II Selector Switch Plate
200.0
< Delivery Total
PROD 2
SELECT
RUN Position
INCREASE
SELECT
PROD 1
SELECT
INCREASE
< Product No.
PROD 3
INCREASE
INCREASE
PROD 2
200.0
PROD 4
< Delivery Total
INCREASE
INCREASE
INCREASE
SELECT
PROD 3
F
70.0
< Flow Rate
INCREASE
k98765
SELECT
SELECT
SELECT
< Temperature
INCREASE
00200.0
< Preset Amount
IN-
L5432.0
PROD 4
38.7 o F
< 10 Digit Totalizer
(leading digits)
< Totalizer
(trailing digits)
SELECT
SELECT
12:30:00
< Time of Day
INCREASE
SELECT
P12345
SELECT
11:30:00
SELECT
< Password
If system is Locked, a password will need to be entered.
< Time of Day Adjust-
PROCEDURE FOR MAKING A PRESET DELIVERY
SHIFT PRINT Position
200.0
< Delivery Total
CALIBRATION Position
098.023
PROD 1
SELECT
1.
2.
3.
4.
< k-Factor
PROD 1
INCREASE
SELECT
INCREASE
INCREASE
PROD 2
PROD 2
INCREASE
“If Delivery is
Active”
INCREASE
PROD 3
PROD 3
INCREASE
INCREASE
PROD 4
PROD 4
INCREASE
INCREASE
Turn the Selector Switch to the STOP position.
Press the SELECT button. The display will show Prod #.
Press INCREASE to select the product desired for delivery.
Press SELECT when the correct Prod # is displayed. This will advance to
the preset display.
5. The left most digit in the display will be flashing. Press INCREASE to set
the value of the first digit. When the value is chosen, press SELECT. The
next digit to the right will flash. If the digit does not need to be changed,
press SELECT to move one digit to the right.
6. Press INCREASE to change the value of the second digit. When the value
is chosen, press SELECT.
7. Continue in this manner until all digit positions have been selected. After the
last digit is selected, the display will return to the first screen, which is the
Delivery Total. Or, switch to RUN when the desired amount is shown.
8. Turn the Selector Switch to RUN. DO NOT OPEN THE HOSE NOZZLE.
When the display stops counting, turn the Selector Switch back to STOP.
This step is necessary to allow for hose stuffing. If less than 1 Gallon was
recorded, the display will reset to 0 and no ticket will be printed.
9. Turn the Selector Switch to RUN. The display will reset and the hose nozzle
should now be opened to start the delivery. When the preset has been
reached, the valve will close.
10. Turn the Selector Switch to the PRINT position to print out a delivery ticket.
INCREASE
k98765
< 10 Digit Totalizer
F
70.0
< Flow Rate
PROCEDURE FOR PRINTING A DIAGNOSTIC TICKET
SELECT
SELECT
1.
2.
3.
INCREASE
27.2 o F
L5432.0
< Totalizer
(trailing digits)
< Temperature
SELECT
Put a blank ticket in the Epson Printer.
Turn the Selector Switch to SHIFT PRINT for less than 2 seconds.
Turn the Selector Switch back to PRINT and a Diagnostic ticket will be
printed.
SELECT
102.965
< k-Factor
PROCEDURE FOR PRINTING A SHIFT TICKET
SELECT
1.
2.
Put a blank ticket in the Epson Printer.
Turn the Selector Switch to SHIFT PRINT for more than 2 seconds.