Department of Public Works Bureau of Street Use and Mapping CURB RAMP CHECK LIST DPW STANDARD CURB RAMP PLAN 55,017 REV 3 NOTE: The curb ramp evaluation is ONLY applicable to the existing ramp (if any) where the path of travel is disrupted Date: Applicant Name: Excavation Permit No.: Intersection: 10/31/2011 AT&T (Allan Ayson) 11EXC-4457 Cyril Magnin St & Ellis St. Curb return Corner (circle one): NE NW N SE SW S Please input existing condition on items 1 through 9 Description (A) 1. Is there a curb ramp at the curb return? 2. RAMP (4-ft wide center portion) Existing Condition (B) Standard Condition (C) YES A curb return requires at least one standard curb ramp per DPW standard curb ramp plan 55,017 Rev 3 YES YES 4-ft wide ramp YES 2.a. Level landing Upper end (top) of Ramp YES 2.b. Level landing lower end (gutter) of Ramp YES 2.c. Width of Ramp OK Minimum 4-ft wide level landing at upper end of ramp. Maximum cross slope 2% A level landing of 2 ft with a cross slope maximum of 2% for width of the ramp (4-ft) Minimum 4-ft wide Slope of Ramp OK 2.e. Cross slope of Ramp OK Maximum slope of 1:12 (8.33%) unless site conditions; e.g. street slope; constitute a ramp that will exceed 15-ft length. Maximum slope of 2% 2.f. Ramp centerline YES Parallel to crosswalk. YES Slip Resistant 2.d. Does it meet the Standard Conditions specified in column C? (Yes or No) YES YES YES YES YES Ramp Surface 2.g. NO Description (A) Existing Condition (B) Standard Condition (C) Does it meet the Standard Conditions specified in column C? (Yes or No) RAMP FLARE (area on either side of ramp) 3 3.a. Slope of Flare 3.b. Flare Surface OK 3.b. Distance between flares OK ELLIS ST CYRIL MAGNIN ST 4. Street name 5. Curb ramp border YES 6. Gutter lip YES 7. Vertical obstructions within flared sides OK 9. Detectable Surface OK Does this curb ramp meet DPW standard Plan 55,017, rev 3? Yes only if all the conditions (1-9) above are met 10. Maximum slope as measured from curb, perpendicular to the ramp plane is 1:10 (10%) OK Please circle One: Yes Slip resistant (?) Only needed if the ramp is constructed using special materials other than concrete. Distance between flares of each curb ramp shall be 4-ft. minimum (Our standard exceptions allow for less than 4’ if site conditions are such that the 4’ cannot be accommodated Stamped in bold Uppercase letters 4-inch high and ½ in deep in the flared side portion of the curb ramp farthest from angular corner or on and adjacent sidewalk flag 12-in wide grooved border. ¼ in wide by ¼ in wide grooves scored ¾ inches apart (except on curb section) The bottom of the ramp shall be flush (no lip) with the gutter Vertical obstructions need to be 6-inches minimum from edge of ramp. Exceptions: pedestrian crosswalk push button and activated device poles, SFFD call box poles CANNOT be placed in ramp or flares. Required for any ramp that is less than (1:15) 6.67% in slope. Refer to curb ramp plans revision 3 for installation. YES YES YES YES YES YES YES YES ellis and cyril magnin, san francisco, ca - Google Maps Page 1 of 1 To see all the details that are visible on the screen, use the "Print" link next to the map. http://maps.google.com/maps?hl=en&tab=wl 10/31/2011 ellis and cyril magnin, san francisco, ca - Google Maps Page 1 of 1 To see all the details that are visible on the screen, use the "Print" link next to the map. http://maps.google.com/maps?hl=en&tab=wl 10/31/2011
© Copyright 2026 Paperzz