Department of Public Works
Bureau of Street Use and Mapping
CURB RAMP CHECK LIST
DPW STANDARD CURB RAMP PLAN 55,017 REV 3
NOTE: The curb ramp evaluation is ONLY applicable to the existing ramp (if any) where the path of travel is disrupted
Date:
Applicant Name:
Excavation Permit No.:
Intersection:
10/31/2011
AT&T (Allan Ayson)
11EXC-4457
Cyril Magnin St & Ellis St.
Curb return Corner (circle
one):
NE
NW
N
SE
SW
S
Please input existing condition on items 1 through 9
Description
(A)
1.
Is there a curb ramp at the
curb return?
2.
RAMP (4-ft wide center
portion)
Existing Condition
(B)
Standard Condition
(C)
YES
A curb return requires at least
one standard curb ramp per
DPW standard curb ramp plan
55,017 Rev 3
YES
YES
4-ft wide ramp
YES
2.a.
Level landing Upper end (top)
of Ramp
YES
2.b.
Level landing lower end
(gutter) of Ramp
YES
2.c.
Width of Ramp
OK
Minimum 4-ft wide level landing
at upper end of ramp.
Maximum cross slope 2%
A level landing of 2 ft with a
cross slope maximum of 2% for
width of the ramp (4-ft)
Minimum 4-ft wide
Slope of Ramp
OK
2.e.
Cross slope of Ramp
OK
Maximum slope of 1:12 (8.33%)
unless site conditions; e.g.
street slope; constitute a ramp
that will exceed 15-ft length.
Maximum slope of 2%
2.f.
Ramp centerline
YES
Parallel to crosswalk.
YES
Slip Resistant
2.d.
Does it meet the
Standard
Conditions
specified in
column C?
(Yes or No)
YES
YES
YES
YES
YES
Ramp Surface
2.g.
NO
Description
(A)
Existing Condition
(B)
Standard Condition
(C)
Does it meet the
Standard
Conditions
specified in
column C?
(Yes or No)
RAMP FLARE (area on
either side of ramp)
3
3.a.
Slope of Flare
3.b.
Flare Surface
OK
3.b.
Distance between flares
OK
ELLIS ST
CYRIL MAGNIN ST
4.
Street name
5.
Curb ramp border
YES
6.
Gutter lip
YES
7.
Vertical obstructions within
flared sides
OK
9.
Detectable Surface
OK
Does this curb ramp meet
DPW standard Plan 55,017,
rev 3? Yes only if all the
conditions (1-9) above are met
10.
Maximum slope as measured
from curb, perpendicular to the
ramp plane is 1:10 (10%)
OK
Please circle One:
Yes
Slip resistant (?) Only needed if
the ramp is constructed using
special materials other than
concrete.
Distance between flares of
each curb ramp shall be 4-ft.
minimum (Our standard
exceptions allow for less than 4’
if site conditions are such that
the 4’ cannot be
accommodated
Stamped in bold Uppercase
letters 4-inch high and ½ in
deep in the flared side portion
of the curb ramp farthest from
angular corner or on and
adjacent sidewalk flag
12-in wide grooved border. ¼
in wide by ¼ in wide grooves
scored ¾ inches apart (except
on curb section)
The bottom of the ramp shall be
flush (no lip) with the gutter
Vertical obstructions need to be
6-inches minimum from edge of
ramp. Exceptions: pedestrian
crosswalk push button and
activated device poles, SFFD
call box poles CANNOT be
placed in ramp or flares.
Required for any ramp that is
less than (1:15) 6.67% in slope.
Refer to curb ramp plans
revision 3 for installation.
YES
YES
YES
YES
YES
YES
YES
YES
ellis and cyril magnin, san francisco, ca - Google Maps
Page 1 of 1
To see all the details that are visible on the
screen, use the "Print" link next to the map.
http://maps.google.com/maps?hl=en&tab=wl
10/31/2011
ellis and cyril magnin, san francisco, ca - Google Maps
Page 1 of 1
To see all the details that are visible on the
screen, use the "Print" link next to the map.
http://maps.google.com/maps?hl=en&tab=wl
10/31/2011