Rockbrake® RB220-Roxul®1000

Product Data Sheet
Rockbrake® RB220-Roxul®1000
Engineered mineral fibre (Note Q) for application in friction materials
Rockbrake® RB220-Roxul®1000 is a premium quality engineered mineral fibre. Its surface treatment gives an
optimum bond with phenolic resins resulting in better reinforcement properties under extreme braking conditions.
The percentage of non fibrous material > 125 microns is with a maximum of 0.2% very low.
Roxul®1000 chemistry
=biosoluble chemistry
All Roxul®1000 products
are worldwide exonerated
from classification as a
carcinogen.
Typical average fibre diameter
Chemical Analysis
SiO2
Al2O3
CaO+MgO
FeO
K2O+Na2O
Others
Min.
38 %wt
18 %wt
23 %wt
4.5 %wt
Max.
43 %wt
23 %wt
28 %wt
8 %wt
4.5 %wt
6 %wt
Typical average fibre length
30
40
35
25
30
20
25
15
20
15
10
10
5
5
%
0
%
0
5
Fibre Diameter >
10
15
20
0
25
0
200
Fibre Length >
400
600
800
1000
ADVANTAGES OF ROCKBRAKE® RB220-ROXUL®1000:
-
Rockbrake® RB220-Roxul®1000 also positively influences the following parameters :
- material wear
- noise and vibrations
-
Rockbrake® RB220-Roxul®1000 is consistent in quality in terms of :
- chemical composition
- surface treatment
- purity
- fibre length
-
Using Rockbrake® RB220-Roxul®1000 gives formulators the opportunity to decrease the use of other fibres
in the matrix (aramid, steel, glass, ceramic, copper, brass), resulting in significant cost savings on a price per
volume base.
Parameter
0
Non-Fibrous Material
Average/Tolerance
Norm.
0
0 N > 125 µm
0
0.08%wt
Testmethod
Max.
0.2%wt
0 TV 316
0
1
Fibre Length
1 230 ± 50 micron
1 TV 305
0
Ignition Loss
0 max. 0.3 %wt
0 TV 302
1
Moisture Content
1 max. 0.1 %wt
1 TV 302
0
Fibre diameter (mass wt. av.)
0 approx. 9.0 micron
0 TV 165
1
Fibre diameter ( num. av.)
1 approx. 5.5 micron
1 TV 165
0
Specific surface area
0 approx. 0.20 m2/g
0 TV 165
1
Hardness
1 6 Moh
1
0
Melting Point
0 > 1000 ºC
0 Furnace, Visual
1
Specific Density
1 2.75 ± 0.15 g/cm3
1
0
Colour
0 Grey/Green
0 Visual
Author: E. Huynen (ADC)
Issue: September 2008 (03)
Replaces Issue: December 2003 (02)
ISO 9001 LF007.F08
“The information contained herein is based upon data considered to be accurate. However, no warranty is expressed or implied regarding the accuracy of these data, the results to be obtained from their use
thereof, or any such use will not infringe upon any patent. This information is furnished only as a guide and upon the condition that the person receiving it shall make tests to determine its accuracy and
suitability for his or her own purpose”.