GROUND MOVEMENT ASSESSMENT REPORT 134 Old Street London EC1 Client: YPP Ltd Engineer: Gurney Consulting Engineers J16116A July 2016 134 Old Street, London EC1V 9BL YPP Ltd Ground Movement Assessment Report Document Control Project title 134 Old Street, London, EC1V 9BL Project ref J16116A Report prepared by Jack Deaney BSc FGS Martin Cooper BEng CEng MICE FGS Report checked and approved for issue by Steve Branch BSc MSc CGeol FGS FRGS MIEnvSc Issue No Status Date 1 Final 28 July 2016 Approved for Issue This report has been issued by the GEA office indicated below. Any enquiries regarding the report should be directed to the office indicated or to Steve Branch in our Herts office. Hertfordshire tel 01727 824666 [email protected] Nottinghamshire tel 01509 674888 [email protected] Geotechnical & Environmental Associates Limited (GEA) disclaims any responsibility to the Client and others in respect of any matters outside the scope of this work. This report has been prepared with reasonable skill, care and diligence within the terms of the contract with the Client and taking account of the manpower, resources, investigation and testing devoted to it in agreement with the Client. This report is confidential to the Client and GEA accepts no responsibility of whatsoever nature to third parties to whom this report or any part thereof is made known, unless formally agreed beforehand. Any such party relies upon the report at their own risk. This report may provide advice based on an interpretation of legislation, guidance notes and codes of practice. GEA does not however provide legal advice and if specific legal advice is required a lawyer should be consulted. © Geotechnical & Environmental Associates Limited 2016 Ref J16116A Issue No 1 28 July 2016 i 134 Old Street, London EC1V 9BL YPP Ltd Ground Movement Assessment Report CONTENTS 1.0 INTRODUCTION 1.1 Proposed Development 1.2 Limitations 1 1 1 2.0 THE SITE 2.1 Site Description 2 2 3.0 SUMMARY OF GROUND CONDITIONS 3 4.0 CONSTRUCTION SEQUENCE 3 5.0 GROUND MOVEMENTS 5.1 Ground Movements - Surrounding the Basement 5.2 Movements within the Excavation (Heave) 3 4 6 6.0 DAMAGE ASSESSMENT 6.1 Damage to Neighbouring Structures 6.2 Monitoring of Ground Movements 7 7 8 7.0 CONCLUSIONS 9 APPENDICES Ref J16116A Issue No 1 28 July 2016 ii 134 Old Street, London EC1V 9BL YPP Ltd 1.0 Ground Movement Assessment Report INTRODUCTION Geotechnical and Environmental Associates (GEA) has been commissioned by Gurney Consulting Engineers, on behalf of YPP Ltd, to complete a ground movement assessment for the proposed construction of a new single level basement beneath No 134 Old Street, London, EC1V 9BL. A Desk Study and Ground Investigation Report has previously been carried out by GEA (report ref J16116, dated July 2016) and the findings of the report have been used in the derivation of parameters for use in this assessment. The purpose of this assessment has been to assess any effects of the proposed basement construction upon nearby sensitive structures. 1.1 Proposed Development Consideration is being given to the redevelopment of the site through the demolition of the existing buildings and construction of a five-storey mixed use building with single-storey partial basement, extending to a depth of approximately 4.0 m. The plan below shows the proposed development. This report is specific to the proposed development and the advice herein should be reviewed once the development proposals are finalised. Ref J16116A Issue No 1 28 July 2016 1 134 Old Street, London EC1V 9BL YPP Ltd 1.2 Ground Movement Assessment Report Limitations The conclusions and recommendations made in this report are limited to those that can be made on the basis of the investigation. The results of the work should be viewed in the context of the range of data sources consulted, the number of locations where the ground was sampled and the number of soil, gas or groundwater samples tested; no liability can be accepted for information in other data sources or conditions not revealed by the sampling or testing. Any comments made on the basis of information obtained from the client or other third parties are given in good faith on the assumption that the information is accurate; no independent validation of such information has been made by GEA. 2.0 THE SITE 2.1 Site Description The site is located approximately 300 m west of Old Street London Underground Station and is bounded by Old Street to the north, a six-storey mixed use building to the west, a fivestorey office block to the east and a three-storey residential block to the south. It can also be located by National Grid Reference 532460, 182390. The site forms a roughly L-shaped area measuring approximately 15 m by 8 m at its greatest extent and is occupied by a two-storey plus roof accomodation. The western half of the building, comprises only the second floor and overhangs an access route to Tilney Court, which forms an external communal area for the residential block bounding the south of the site as seen on the photograph below. The external ground surface dips slightly to the south from 19.7 m OD to 19.4 m OD. The ground floor level within the building is sensibly level across site at 20.15 m OD. The site and surrounding area are completely covered in hardstanding and devoid of any vegetation. Ref J16116A Issue No 1 28 July 2016 2 134 Old Street, London EC1V 9BL YPP Ltd 3.0 Ground Movement Assessment Report SUMMARY OF GROUND CONDITIONS Beneath a relatively significant thickness of made ground, the Hackney Gravel was encountered, underlain by the London Clay Formation. The made ground varied in thickness, extending to 5.3 m (14.85 m OD) in the north and to 2.40 m (17.75 m OD) it the south. Its composition was relatively consistent in that it comprised silty sand or sandy clay with fragments of brick, shells, concrete, pottery, ash, decaying wood, flint and coal. In the area around Borehole No 1 a slight hydrocarbon odour was noted. The Hackney Gravel comprised an initial layer of soft becoming firm brown very sandy clay which extended to depths of between 5.10 m and 6.0 m (14.4 m OD and 14.15 m OD), where it graded into a dense brown fine to coarse grained gravelly sand with partings of firm clay to a depth of 6.7 m (13.45 m OD). The London Clay Formation comprised an initial layer of firm brown mottled grey slightly fissured silty clay to a depth of 8.0 m (11.5 m OD) where it was underlain by a firm becoming stiff fissured blueish grey silty clay to the maximum depth investigated, of 15.0 m (4.5 m OD). According to local BGS archive records the base of the London Clay is at a depth of approximately 25.0 m (-4.85 m OD), where it is underlain by the Lambeth Group Formation. 4.0 CONSTRUCTION SEQUENCE For the purposes of the ground movement assessment, the datum is taken as the existing ground floor level, at an arbitrary level of zero. It is proposed to construct a basement to 4.0 m depth beneath the existing ground floor level across the majority of the footprint of the building. The proposed basement wall adjoining 1-5 Tilney Court will be formed by means of traditional underpinning to a depth of 4.0 m below existing ground floor level, whilst the other three walls will be formed by means of a contiguous piled wall embedded to 12.0 m depth below existing ground floor level. The following sequence of operations has been assumed to enable analysis of the ground movements around the proposed basement both during and after construction. In general, the sequence of works for basement construction will comprise the following stages. 1. Construct underpinned retaining walls. These are commonly formed in a ‘hit and miss’ sequence using a trench box excavation, commonly sheet lined, shored and strutted; all temporary shoring and propping to be inspected by a suitably qualified person; 2. Construct contiguous piled walls; and 3. excavate new basement and temporarily retain and strengthen, with sufficient propping and walling beams, the new retaining walls. Construct new ground beams. The underpins will be adequately laterally propped and sufficiently dowelled together, concrete cast and adequately cured prior to excavation of the basement and removal of the formwork and supports. It is assumed that the corners of the excavation will be supported by Ref J16116A Issue No 1 28 July 2016 3 134 Old Street, London EC1V 9BL YPP Ltd Ground Movement Assessment Report cross-bracing or similar and that the new retaining walls will not be cantilevered at any stage during the construction process. The detail of the support provided to adjacent walls is beyond the scope of this report at this stage and the structural engineer will be best placed to agree a methodology with the underpinning contractor once appointed. When the final excavation depths have been reached the permanent works will be formed, which are likely to comprise reinforced concrete walls with a drained cavity lining the inside of the underpinned wall. Reinforced concrete will be used for the floor slabs and it is anticipated that heave protection may be installed beneath the basement slab. Following this, the floor slab will be constructed at basement depth and the temporary props will be removed. 5.0 GROUND MOVEMENTS An assessment of ground movements within and surrounding the excavation has been undertaken using the X-Disp and P-Disp computer programs licensed from the OASYS suite of geotechnical modelling software from Arup. These programs are commonly used within the ground engineering industry and are considered to be appropriate tools for this analysis. The X-Disp program has been used to predict ground movements likely to arise from the construction of the proposed basement. This includes the settlement of the ground (vertical movement) and the lateral movement of soil behind the proposed retaining walls (horizontal movement). The analysis of potential ground movements within the excavation, as a result of unloading of the underlying soils, has been carried out using the Oasys P-Disp Version 19.3 – Build 12 software package and is based on the assumption that the soils behave elastically, which provides a reasonable approximation to soil behaviour at small strains. For the purpose of these analyses, the corners have been defined by x and y coordinates. In the X-Disp and P- Disp analyses the x-direction is roughly parallel with the orientation eastwest, whilst the y-direction is roughly parallel with the orientation north-south. Vertical movement is in the z-direction. The walls of the existing structures in and surrounding the site have been modelled as 1.0 m long structural elements if the wall is less than 10 m long, or as 2.0 m long structural elements if the wall is greater than 10 m long. The full outputs of all the analyses can be provided on request and samples of the output movement contour plots are included within the appendix. 5.1 Ground Movements – Surrounding the Basement 5.1.1 Model Used For the X-Disp analysis, the soil movement relationships used for the embedded retaining walls are the default values within CIRIA report C5801, which were derived from a number of historic case studies. Whilst it might appear reasonable to adopt the ground movement curves for ‘no horizontal and vertical movement’ for this analysis, in practice there will always be a potential for some movement to take place. There is a wealth of experience with respect to the construction of underpinned retaining walls beneath existing structures, suggesting that ground movements 1 Gaba, A, Simpson, B, Powrie, W and Beadman, D (2003) Embedded retaining walls – guidance for economic design. CIRIA Report C580. Ref J16116A Issue No 1 28 July 2016 4 134 Old Street, London EC1V 9BL YPP Ltd Ground Movement Assessment Report should remain typically within the range of 2 mm to 5 mm following completion of the works, provided that they are installed by a reputable and experienced contractor in accordance with the guidelines published by the Association of Specialist Underpinning Contractors2. The analysis has adopted the values for ‘installation of a planar diaphragm wall’ to represent the installation of the underpinned and reinforced concrete retaining walls, whilst the values for ‘installation of a contiguous bored piled wall in stiff clay’ have been adopted to represent the installation of the contiguous bored piled wall. The ground movement curves for ‘excavations in front of a wall in sand’ have been adopted as most appropriate for the proposed excavation and its support at this site as the walls will be generally supporting granular soils. 5.1.2 Results The predicted movements are based on the worst case of the individually analysed segments of ‘hogging’ and ‘sagging’ and these are summarised in the tables overleaf. It should be noted that the combined effect of segments acting together typically improve the resultant movements and the values below are therefore deemed to be conservative. The diagram below details the relevant sensitive structures in relation to the proposed excavations. Displacement Analysis Points: The building height for each of the nearby sensitive structures has been derived from drawings (0423-4-F-200-00, dated May 2015 and 0423-4-F201-00, dated May 2015) as supplied by the consulting engineer. As no basements are known to be present nearby and in 2 Haslam S, O’Connor L (2013) Guidelines on safe and efficient basement construction directly below or near to existing structures ASUC Ref J16116A Issue No 1 28 July 2016 5 134 Old Street, London EC1V 9BL YPP Ltd Ground Movement Assessment Report the absence of foundation information for each structure, a foundation depth of 1 m below ground level has been assumed. The movements predicted by X-Disp are summarised in the table below; the results are presented below and in subsequent tables to the degree of accuracy required to allow predicted variations in ground movements around the structure to be illustrated, but may not reflect the anticipated accuracy of the predictions. Wall Movement (mm) Phase of Works Vertical Settlement Horizontal Movement Installation of retaining walls <5 <5 Combined Retaining Wall and Excavation Movements 5 to 17 <5 The analysis has indicated that the maximum vertical and horizontal settlements that will result from wall installation are likely to be less than 5 mm. The movements arising from the combined wall installation and excavation phases are not likely to exceed 17 mm of vertical settlement, whilst the maximum horizontal movements are not anticipated to exceed 5 mm. The estimated movements are considered to represent a worst case scenario, particularly as the movements resulting from basement excavation will be minimised due to control of the propping in the temporary works. 5.2 Movements within the Excavation (Heave) 5.2.1 Model Used At this site unloading of the London Clay under the Hackney Gravel will take place as a result of the proposed basement excavation and the reduction in vertical stress in the short term will cause heave to take place. Undrained soil parameters have been used to estimate the potential short term movements, which include the “immediate” or elastic movements as a result of the basement excavation. Drained parameters have been used to provide an estimate of the total long-term movement. The elastic analysis requires values of soil stiffness at various levels to calculate displacements. Values of stiffness for the soils at this site are readily available from published data and we have used a well-established method to provide our estimates. This relates values of Eu and E', the drained and undrained stiffness respectively, to values of undrained cohesion, as described by Padfield and Sharrock3 and Butler4 and more recently by O’Brien and Sharp5. Relationships of Eu = 500 Cu and E’ = 300 Cu for the cohesive soils and 2000 x SPT ‘N’ for granular soils have been used to obtain values of Young’s modulus. More recent published data6 indicates stiffness values of 750 x Cu for the London Clay and a ratio of E’ to Cu of 0.75, but it is considered that the use of the more conservative values provides a sensible approach for this stage in the design. 3 4 5 6 Padfield CJ and Sharrock MJ (1983) Settlement of structures on clay soils. CIRIA Special Publication 27 Butler FG (1974) Heavily overconsolidated clays: a state of the art review. Proc Conf Settlement of Structures, Cambridge, 531578, Pentech Press, London. O’Brien AS and Sharp P (2001) Settlement and heave of overconsolidated clays - a simplified non-linear method. Part Two, Ground Engineering, Nov 2001, 48-53 Burland JB, Standing, JR, and Jardine, FM (2001) Building response to tunnelling, case studies from construction of the Jubilee Line Extension. CIRIA Special Publication 200 Ref J16116A Issue No 1 28 July 2016 6 134 Old Street, London EC1V 9BL YPP Ltd Ground Movement Assessment Report The soil parameters used in this assessment are tabulated below. Stratum Depth range (m) [Level range mOD] Eu (MPa) E’ (MPa) Made Ground G/L to 3.0 17.5 10.5 Hackney Gravel 3.0 to 6.5 50 50 London Clay 6.5 to 25.0 32.5 to 170 19.5 to 51 Lambeth Group 25.0 to 36.0 170 to 250 51 to 75 A rigid boundary for the analysis has been set at a depth of 36 m below existing ground level, where nearby BGS records indicate that the base of the Lambeth Group is likely to be present. Given the site investigation didn’t reach the Lambeth Group, strength parameters have been derived using in-house dataset and engineering judgement. 5.2.2 Results The proposed excavation of the new basement will result in a net unloading of approximately 75 kN/m². The P-Disp analysis indicates that, by the time the basement construction is complete, around 8 mm of heave is likely to have taken place at the centre of the proposed excavation, while around 3 mm to 5 mm of settlement will have occurred at the edges. An additional 7 mm to 8 mm of long term heave may theoretically occur at the centre of the proposed excavation following construction while an additional 3 mm of settlement may occur at the edges of the excavation. The results of the P-Disp analysis can be used to indicate the likely impact of the proposed basement construction beyond the site boundaries; about 5 m away from the excavation a total movement of less than 5 mm is predicted. In addition, movements outside the excavation will be further constrained to a certain extent by the presence of the new retaining walls. The basement floor slab will need to be designed to resist the potential heave pressures which are typically taken to equate to around 30 % of the total unloading pressure. 6.0 DAMAGE ASSESSMENT In addition to the above assessment of the likely movements that will result from the proposed development, the neighbouring buildings are considered to be sensitive structures, requiring Building Damage Assessments, on the basis of the classification given in Table 2.5 of C5801. All structures are shown on the plan in Section 5.1.2. 6.1 Damage to Neighbouring Structures The movements resulting from the wall installation phase and the combined retaining wall installation and basement excavation phases, have been calculated using the X-Disp modelling software to carry out an assessment of the likely damage to adjacent properties and the results are summarised for the combined wall installation and basement excavation in the table below. Where the analysis has indicated that the structure is unlikely to experience Ref J16116A Issue No 1 28 July 2016 7 134 Old Street, London EC1V 9BL YPP Ltd Ground Movement Assessment Report damage of higher than Category 0 – Negligible, they have not been included within the table below. The potential heave movements predicted by P-Disp have not been included in this assessment. Building Damage Assessment Sensitive Structure Elevation Category of Damage* Structure B N Category 1 (Very Slight) W3 Category 1 (Very Slight) W4 Category 1 (Very Slight) E Category 1 (Very Slight) W Category 1 (Very Slight) Structure C Structure D *From Table 2.5 of C5801: Classification of visible damage to walls. The analysis has predicted that the proposed installation of the retaining walls and excavation of the proposed basement may generally result in a building damage for sensitive structures of Category 0 (negligible) and Category 1 (Very Slight), which fall within acceptable limits. In practice, the underpinning of the existing foundations, installation of the contiguous piled wall and the subsequent excavation of the proposed basement will be staged processes and will take place over a number of weeks. This will provide an opportunity for the ground movements during and immediately after the installation of the retaining walls to be measured and the data acquired can be fed back into the design and compared with the predicted values. Such a comparison will allow the ground model to be reviewed and the predicted wall movements to be reassessed prior to the main excavation taking place so that propping arrangements can be adjusted if required. In addition to the above, there is a wealth of experience with respect to the construction of underpinned retaining walls, that suggests that ground movements should remain typically within the range of 2 mm to 5 mm following completion of the works and provided that they are installed by a reputable and experienced contractor in accordance with the guidelines published by the Association of Specialist Underpinning Contractors 7, which indicates that the predicted movements represent a conservative assessment of the likely movements. 6.2 Monitoring of Ground Movements The predictions of ground movement based on the ground movement analysis should be checked by monitoring of the adjacent properties and structures. The structures to be monitored during the construction stages should include the neighbouring structures. Condition surveys of the above existing structures should be carried out before and after the proposed works. The precise monitoring strategy will be developed at a later stage and it will be subject to discussions and agreements with the owners of the adjacent properties and structures. Contingency measures will be implemented if movements of the adjacent structures exceed 7 Haslam S, O’Connor L (2013) Guidelines on safe and efficient basement construction directly below or near to existing structures ASUC Ref J16116A Issue No 1 28 July 2016 8 134 Old Street, London EC1V 9BL YPP Ltd Ground Movement Assessment Report predefined trigger levels. Both contingency measures and trigger levels will need to be developed within a future monitoring specification for the works. Ref J16116A Issue No 1 28 July 2016 9 134 Old Street, London EC1V 9BL YPP Ltd 7.0 Ground Movement Assessment Report CONCLUSIONS The analysis has predicted that the proposed installation of the retaining walls and excavation of the proposed basement may generally result in a building damage for sensitive structures of Category 0 (negligible) and Category 1 (Very Slight), which fall within acceptable limits. The separate phases of work, including excavation of the proposed basement, will in practice be separated by a number of weeks during which time construction of permanent supports, basement slab and retaining wall curing will take place. This will provide an opportunity for the ground movements during and immediately after retaining wall construction to be measured and the data acquired can be fed back into the design and compared with the predicted values. Such a comparison will allow the ground model to be reviewed and the predicted wall movements to be reassessed prior to the main excavation taking place so that propping arrangements can be adjusted if required. Ref J16116A Issue No 1 28 July 2016 10 134 Old Street, London EC1V 9BL YPP Ltd Ground Movement Assessment Report APPENDICES X-DISP ANALYSIS: Wall Installation Contour Plots of Vertical Movements and Horizontal Movements Wall Installation and Basement Excavation combined Contour Plots of Combined Vertical Movements and Horizontal Movements P-DISP ANALYSIS Short Term Movement Contour Plots Total Movement Contour Plots Ref J16116A Issue No 1 28 July 2016 11 GEA LIMITED (GEOTECHNICAL &ENV ASSOC) 134 Old Street, London, EC1v 9BL Wall installation Job No. Sheet No. Rev. J16116 Drg. Ref. Made by JD Date 12-Jul-2016 Checked Horizontal Displacement Contours: Grid 1 (level -1.000m) Interval 1mm 220.0 <0 0-1 1-2 210.0 2-3 3-4 200.0 4-5 y [m] 190.0 180.0 170.0 160.0 150.0 240.0 280.0 320.0 360.0 Scale x 1:982 y 1:982 x [m] Program Xdisp Version 19.3.1.35 Copyright © Oasys 1997-2015 G:\CURRENT\16-\J16116\GMA\Xdisp\134 Old St wall installation.xdd Printed 20-Jul-2016 Page 1 Time 14:24 GEA LIMITED (GEOTECHNICAL &ENV ASSOC) 134 Old Street, London, EC1v 9BL Wall installation Job No. Sheet No. Rev. J16116 Drg. Ref. Made by JD Date 12-Jul-2016 Checked Vertical Settlement Contours: Grid 1 (level -1.000m) (Interval 1mm) 220.0 <0 0-1 1-2 210.0 2-3 3-4 200.0 4-5 y [m] 190.0 180.0 170.0 160.0 150.0 240.0 280.0 320.0 360.0 Scale x 1:982 y 1:982 x [m] Program Xdisp Version 19.3.1.35 Copyright © Oasys 1997-2015 G:\CURRENT\16-\J16116\GMA\Xdisp\134 Old St wall installation.xdd Printed 20-Jul-2016 Page 1 Time 14:24 GEA LIMITED (GEOTECHNICAL &ENV ASSOC) 134 Old Street, London, EC1v 9BL Combined Job No. Sheet No. Rev. J16116 Drg. Ref. Made by JD Date 12-Jul-2016 Checked Horizontal Displacement Contours: Grid 1 (level -1.000m) Interval 1mm 220.0 <0 0-1 1-2 210.0 2-3 3-4 200.0 4-5 y [m] 190.0 180.0 170.0 160.0 150.0 240.0 280.0 320.0 360.0 Scale x 1:982 y 1:982 x [m] Program Xdisp Version 19.3.1.35 Copyright © Oasys 1997-2015 G:\CURRENT\16-\J16116\GMA\Xdisp\134 Old St Combined.xdd Printed 20-Jul-2016 Page 1 Time 14:27 GEA LIMITED (GEOTECHNICAL &ENV ASSOC) 134 Old Street, London, EC1v 9BL Combined Job No. Sheet No. Rev. J16116 Drg. Ref. Made by JD Date 12-Jul-2016 Checked Vertical Settlement Contours: Grid 1 (level -1.000m) (Interval 1mm) 220.0 <0 0-1 1-2 210.0 2-3 3-4 200.0 4-5 5-6 6-7 y [m] 190.0 7-8 8-9 9 - 10 180.0 10 - 11 11 - 12 170.0 12 - 13 13 - 14 14 - 15 160.0 15 - 16 16 - 17 150.0 240.0 280.0 320.0 360.0 Scale x 1:982 y 1:982 x [m] Program Xdisp Version 19.3.1.35 Copyright © Oasys 1997-2015 G:\CURRENT\16-\J16116\GMA\Xdisp\134 Old St Combined.xdd Printed 20-Jul-2016 Page 1 Time 14:28 GEA LIMITED (GEOTECHNICAL &ENV ASSOC) 134 Old Street, London, EC1V 9BL Short term heave Job No. Sheet No. Rev. J16116 Drg. Ref. Made by JD Date Checked Settlement Contours : Grid 1 at -4.0000m 60.00 -8.000 : -7.00 -7.000 : -6.00 -6.000 : -5.00 -5.000 : -4.00 -4.000 : -3.00 -3.000 : -2.00 50.00 -2.000 : -1.00 -1.000 : 0 0 : 1.000 40.00 Y [m] 30.00 20.00 10.00 .0 -10.00 10.00 Scale x 1:448 y 1:448 Contour Interval: 1mm Program Pdisp Version 19.3.0.4 30.00 50.00 X [m] Copyright © Oasys 1997-2015 Printed 20-Jul-2016 Page 1 Time 14:47 GEA LIMITED (GEOTECHNICAL &ENV ASSOC) 134 Old Street, London, EC1V 9BL Total Heave Job No. Sheet No. Rev. J16116 Drg. Ref. Made by JD Date Checked Settlement Contours : Grid 1 at -4.0000m 60.00 -16.00 : -15.0 -15.00 : -14.0 -14.00 : -13.0 -13.00 : -12.0 -12.00 : -11.0 -11.00 : -10.0 50.00 -10.00 : -9.00 -9.000 : -8.00 -8.000 : -7.00 -7.000 : -6.00 -6.000 : -5.00 40.00 -5.000 : -4.00 -4.000 : -3.00 -3.000 : -2.00 -2.000 : -1.00 -1.000 : 0 Y [m] 30.00 20.00 10.00 .0 -10.00 10.00 Scale x 1:448 y 1:448 Contour Interval: 1mm Program Pdisp Version 19.3.0.4 30.00 50.00 X [m] Copyright © Oasys 1997-2015 Printed 20-Jul-2016 Page 1 Time 14:51 Geotechnical & Environmental Associates (GEA) is an engineer‐led and client‐ focused independent specialist providing a complete range of geotechnical and contaminated land investigation, analytical and consultancy services to the property and construction industries. We have offices at Widbury Barn Widbury Hill Ware Hertfordshire SG12 7QE tel 01727 824666 mail@gea‐ltd.co.uk Church Farm Gotham Road Kingston on Soar Notts NG11 0DE tel 01509 674888 midlands@gea‐ltd.co.uk Enquiries can also be made on‐line at www.gea‐ltd.co.uk where information can be found on all of the services that we offer.
© Copyright 2026 Paperzz