Quick Guide #2D: Philips MRx Configuration and Operation with RosettaDS (Serial Cable Connection) I. Configuration instructions for Philips MRx for use with Rosetta-DS via Serial Cable • II. Required settings: o No required settings, but MRx monitor must have 12-Lead Option and B11 Rosetta Option. See Appendix A at the end of this document for instructions to check for the required options. Connecting Philips MRx to PC with Rosetta-DS 1. Connect the MRx monitor to the computer with Rosetta-DS by using a DB9 F-F serial cable as shown below. Note: This is not a 1-1 Serial cable, it is a null modem cable. (Continued on next page) III. Configuration instructions for Rosetta-DS for use with Philips MRx via serial cable Note: Computer must have an available RS-232 Serial Port. 1. Launch Rosetta-DS. At the main screen of Rosetta-DS click the [Settings] button. A password box may appear. The default password is “GDrosetta”. 2. Next click the [Setup] button. (Continued on next page) 2 3. Check the Enable Comm Port checkbox, select the Comm Port (Usually Comm 1) and set the Baudrate to 38400. NOTE: If Comm Port 1 does not work, try Comm Port 2. 4. Click the button. 5. To complete the step, click the 6. Click the button, then click . button at the top right of the Rosetta-DS window, then click . 7. Restart Rosetta-DS by double clicking the shortcut on the desktop. IV. Acquiring and Sending a 12-Lead from the Philips MRx to Rosetta-DS 1. Press the 12-Lead button to go into the 12-Lead menu. (Continued on next page) 3 2. Press the Start Acquire button to acquire a 12-Lead. 3. To send the 12-Lead to Rosetta-DS, press the Menu button and select Send. 4. Using the arrow buttons, select Rosetta-Lt from the Send To menu. Note: The MRx does not allow this to be renamed to Rosetta-DS. (Continued on next page) 4 5. The 12-Lead will begin transmitting to Rosetta-DS. See Quick Guide #9: Sending a 12-Lead from Rosetta-DS to Destinations -END PROCEDURE- 5 Appendix A To check if the required options are present in the MRx monitor, follow these steps: 1. Go to the Menu by pressing the Check Mark button below the Menu at the bottom right corner of the MRx screen. 2. Scroll down using the arrow buttons and select Other by pressing the Check Mark button. 3. Next scroll down to Print Device Info and press the Check Mark button. 6 4. A page with all of the device information will print out. Look for the Options section. It should have 12-Lead and 12-LTx Rosetta-Lt. 5. Once you have confirmed the required options are present, scroll down to Exit and press the Check Mark button. 7
© Copyright 2026 Paperzz