DPM 96 VDC - C / F Operating Manual The DPM 96VDC is a digital standard instrument for measurement of DC mV with 2 ranges & DC Voltage with 4 ranges in 96x96 DIN quadratic size. Three ranges for power supply are available. Operation: Multi range of Input can be selected by changing the input terminal at back side of the DPM. By changing short links on the front side of Dispaly (Accessible after removing Front Glass & Black Frame) decimal point can be adjusted as shown in sticker on page2. The full scale value will be adjusted with potentiometer in the range 1:10 at the back of the instrument, like wise zero point can be adjusted (for mV model only). Further DPM 96 ADC version from the series: DPM 96 ADC Instrument for DC Current measurement, 2 ranges. Technical data Display Measuring ranges (Max.overload 20 % of full-scale value) Power supply Display range Decimal point position Negative diplay indication Digit height Overload indication Accuracy for mV for Voltage DC mV (Input Current < 300 uA) 1999 selectable by rear jumper position „-“ 14 mm / 7-segment digits. (Optional 20 mm) last 3 digits blank < 0.1 %+ 1 digit < 0.2 %+ 1 digit 0 ... 60 mV 0 ... 150 mV DC Voltage 0 ... 2 V 0 ... 20 V 0 ... 200 V 0 ... 500 V Temperature coefficient zero point drift Range adjustment span 300 ppm / °C 200 ppm / °C from 10% to 100% of range Direct voltage DC 24 +/- 10% 12 +/- 10% max. 5.5 W max. 5.5 W Alternating voltage (47 - 60 Hz) 110 V +10 %, -15 % 230 V +10 %, -15 % Climatic class Operating temperature Storage temperature Class 2 to VDE / DIN 3540 0 ... 50 °C -25 °C ... +70 °C Safety class Protection class Front Device safety EMC immunity EMC radiated interference II to IEC 348 / VDE 0411 IP 20 to IEC EN 60 529 IP 50 (IP 54 on request) According to IEC EN 61 010 According to IEC / EN 61 000-4-1 to 4 According to IEC / EN 61326 Class B Dimensions and weights Front bezel size Panel cut-out Overall depth Weight 96 mm x 96 mm (DIN 43 700) 92 +0.8 mm x 92 +0.8 mm 55 mm 300 gm. approx. Sundry Connections Plug-in screw terminal blocks Environmental conditions max. 5.5 W max. 5.5 W SAMPLE STICKERS DC mV Input : DC V Input : MEASURING INPUT : For DPM 96VDC mV Input : mV DC Input 0 .... 60mV 0 .... 150mV Auxiliary Supply Display adjust (with external calibrator) Decimal point adjustment Terminals 1 and 2. Terminals 1 and 3. Terminals A (-/N) and B (+/L). With zero and span pots at rear of the meter. With short links at front on Display. For DPM 96VDC V Input : V DC Input Auxiliary Supply Display adjust (with external calibrator) Decimal point adjustment Terminals 1 and - Terminals 3 : 0 ... 500V DC - Terminals 5 : 0 ... 200V DC - Terminals 6 : 0 ... 20V DC - Terminals 7 : 0 ... 2V DC Terminals A (-/N) and B (+/L). With span pot at rear of the meter. With short links at front on Display. DESIGN & INSTALLATION : Installation Cutout : CONNECTION DIAGRAM : For DC Voltage Input : For DC mV Input : DECIMAL POINT ADJUSTMENT : Decimal point position is selectable by short links at the front side of Display Caution : Do not change the Short links on Display (For Decimal point Adjustment) when input is applied to the DPM ! Subject to change without notice! I. C. - 15000039 02/2011 ( REV. E ) Printed in India
© Copyright 2026 Paperzz