Model 4158 Tedea-Huntleigh Alloy Steel Double-Ended Shear Beam FEATURES • Capacities 10k–75k lbs • Low profile design for weigh bridge and silo applications • Nickel plated alloy steel construction • NTEP approved • IP67 protection • Optional ❍❍ EEx ia IIC T6 hazardous area approval ❍❍ FM approval available APPLICATIONS • Weigh bridges • Tank and silo weighing DESCRIPTION Model 4158 is a double-ended shear beam load cell designed for high capacity silo weighing applications. This high accuracy load cell is designed to meet NTEP standards. When combined with suitable mounting arrangements, this load cell will provide a simple, accurate and reliable weighing system. Nickel plated and full environmental sealing assure longterm reliability. For hazardous environments, this load cell has a EEX ia IIC T6 approved option. When used in conjunction with Tedea-Huntleigh’s custom designed mount, the unit combines ease of installation with both side load and lift-off protection. OUTLINE DIMENSIONS in millimeters ½" NPT Conduit Adaptor (50–75k lbs only) Cable Gland (10–40k lbs only) E ØA (2pl) M Rad H Rad J N L K G C F CAPACITY 10–25k lbs 40k lbs 50–75k lbs ØA 17.3 20.6 26.9 Document No.: 12038 Revision: 20 Dec 2014 C 42.9 49.3 62.0 D 49.3 62.0 74.7 E 196.9 260.4 260.4 F 165.1 215.9 215.9 G 35.9 49.0 49.0 D RadH 19.1 25.4 25.4 Rad J 22.9 28.5 34.8 Technical contact: [email protected], [email protected], and [email protected] K 41.4 50.8 64.5 L 43.2 53.3 67.3 M 8.8 9.0 10.4 N 13.6 31.0 37.4 www.vpgtransducers.com 1 Model 4158 Tedea-Huntleigh Alloy Steel Double-Ended Shear Beam SPECIFICATIONS PARAMETER VALUE Rated capacity—R.C. (Emax) UNIT 10, 20, 25, 40, 50, 60, 75(1) Klbs NTEP/OIML accuracy class Maximum no. of intervals (n) Y = Emax/Vmin Rated output—R.O. Rated output tolerance Zero balance Zero return, 30 min. Total error Temperature effect on zero NTEP 10000 IIIL 12000 0.030 0.30 0.0013 0.050 0.050 0.0067 Maximum available mV/V ±mV/V ±mV/V ±% of applied load ±% of rated output ±% of rated output/°C Temperature effect on output 0.0025 0.0040 ±% of applied load/°C Non-Approved 1000 4000 3.0 0.075 0.09 Temperature range, compensated Temperature range, safe Maximum safe central overload Ultimate central overload Excitation, recommended Excitation, maximum Input impedance Output impedance Insulation resistance Cable length Cable type Construction Environmental protection –10 to 40 –30 to +70 150 300 10 15 780±20 705±5 >1000 7.5 6-wire, braided, PVC, dual floating screen Nickel-plated alloy steel IP67 °C °C % of R.C. % of R.C. VDC or VAC RMS VDC or VAC RMS Ω Ω MΩ m Standard 10k lbs is not approved by NTEP All specifications subject to change without notice. (1) Wiring Schematic Diagram +ve Input (Red) +ve Output (Green) –ve Input (Black) –ve Output (White) www.vpgtransducers.com 2 Technical contact: [email protected], [email protected], and [email protected] Document No.: 12038 Revision: 20 Dec 2014 Legal Disclaimer Notice Vishay Precision Group, Inc. Disclaimer ALL PRODUCTS, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE. Vishay Precision Group, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively, “VPG”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained herein or in any other disclosure relating to any product. The product specifications do not expand or otherwise modify VPG’s terms and conditions of purchase, including but not limited to, the warranty expressed therein. VPG makes no warranty, representation or guarantee other than as set forth in the terms and conditions of purchase. To the maximum extent permitted by applicable law, VPG disclaims (i) any and all liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special, consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular purpose, non-infringement and merchantability. Information provided in datasheets and/or specifications may vary from actual results in different applications and performance may vary over time. Statements regarding the suitability of products for certain types of applications are based on VPG’s knowledge of typical requirements that are often placed on VPG products. It is the customer’s responsibility to validate that a particular product with the properties described in the product specification is suitable for use in a particular application. You should ensure you have the current version of the relevant information by contacting VPG prior to performing installation or use of the product, such as on our website at vpgsensors.com. No license, express, implied, or otherwise, to any intellectual property rights is granted by this document, or by any conduct of VPG. The products shown herein are not designed for use in life-saving or life-sustaining applications unless otherwise expressly indicated. Customers using or selling VPG products not expressly indicated for use in such applications do so entirely at their own risk and agree to fully indemnify VPG for any damages arising or resulting from such use or sale. Please contact authorized VPG personnel to obtain written terms and conditions regarding products designed for such applications. Product names and markings noted herein may be trademarks of their respective owners. Copyright Vishay Precision Group, Inc., 2014. All rights reserved. Document No.: 63999 Revision: 15-Jul-2014 www.vpgsensors.com 1
© Copyright 2026 Paperzz