The Ryoden G-Series Dumbwaiter represents a more
advanced environment-friendly model which offers
improved operability, functionality, and safety, as well as
an automatic energy-saving mode which effectively
reduces power consumption.
Automatic energy-saving mode
●The energy-saving mode is automatically established
if the dumbwaiter is not operated within the prescribed
period of time. Compared to the past series, this
mode allows up to 53% of energy saving.
Normal dumbwaiter operation can be resumed by
Cage operation is disabled by a switch when the
pressing the Energy-saving mode release button.
door is open. A more reliable forced locking type
has also been adopted.
〈Energy-saving mode release button〉
p
a
g
e
1
p
a
g
e
2
operating panel
Operating panel
p
a
g
e
3
p
a
g
e
4
1.3
2.5
1.7
3.0
2.8
4.6
on handcarts into the car.
operating panel
5.7
8.4
6.8
10.0
7.7
15.1
Operating panel
p
a
g
e
5
p
a
g
e
6
Ryoden G-Series Dumbwaiter
Op ti o n s
Specifications Table
Basic specifications
Cage lamp (LED)
Option
Item
Cage lighting ensures
that delivered items
(even small items) are
clearly visible in dark
environments.
More efficient operability to
facilitate ease of use
* This lighting does not
apply to some models.
For details, please contact
Ryoden.
Convenience
Application
Power service door
This function locks all
doors when an operation
STOP status exists,
thus preventing
mischievous operations,
etc.
Small freight items
●
●
3-phase 200 VAC, 50/60Hz * Power transformer is option.
●
●
Control format
Inverter control
●
●
Energy-saving
Automatic energy-saving mode
●
●
Traction format
●
●
Operation format
Mutual-floors operation format (SEN)
●
●
Number of stops
2 to 8 stops
●
●
Max. 15m
●
●
From 15m to 30m
○
○
45m/min
●
-
Load capacity: 200, 300kg = 45m/min
-
●
Load capacity: 500kg = 23m/min
-
●
Service door: manual upper/lower bi-parting doors
●
●
Cage door: power upper/lower bi-parting doors
●
●
●
●
Auto announce
●
●
Cage position indicator lamp
●
●
Error code indicator lamp
●
●
DOOR OPEN warning (buzzer, announcement)
●
●
Service door lock
●
●
Service door switch
●
●
Cage door gate switch
●
●
Cage overrun limiting switch
●
●
AST system
●
●
Emergency Stop button
●
●
Overload alarm unit
●
●
Drive format
Rated speed
Both the service and
cage doors can be
opened simultaneously by
pressing a button. The
optional remote control
function can also be used
for increased
convenience. An optional
function which
automatically opens the
doors when the cage
arrives is also available.
Return-to-reference-floor function
Additional cage shelf board
An additional shelf
board can be added or
removed according to
the sizes, etc., of the
items being delivered.
* RT type only
Door format
Communication format Interphone: hand-free / press & talk (selectable)
Signal functions
Safety equipment
This function automatically
returns the cage to a specified
floor after its contents have
been delivered. In systems
where the transport direction is
always the same, this function
eliminates the need to recall
the cage, thus increasing
operation efficiency. A learning
function can also be added to
increase efficiency in systems
with frequent-stop floors.
● : Basic specifications ○ : Optional (additional fee) specifications
Specifications table
Jamb
Threshold
Option
Rust-resistant stainless
steel is used at
decorative surfaces.
This also contributes to
a sanitary environment
which is ideal for
restaurant kitchens, etc.
Equipped for better
cleanliness
* Standard construction for
the RT type's floor, shelf
boards, and table.
Sanitary
Operating panel
Service door
Cage interior
Cage door
Service door lock
Option
The service door can be
locked by a dedicated
key.
For increased
operation safety
Table Type
RT
Floor Type
RL
Painted steel plate
●
●
Stainless steel hairline
○
○
Stainless steel hairline
●
-
Painted copper plate
-
●
Stainless steel hairline
-
○
Sealed plastic sheet (splash-proof)
●
●
Stainless steel hairline face plate
○
○
Painted copper plate
●
●
Stainless steel hairline
○
○
Ceiling and walls: painted copper plate
●
●
Ceiling and walls: stainless steel hairline
○
○
Cage floor: stainless steel hairline
●
○
Painted and checkered steel plate for floor
-
●
Shelf boards: stainless steel hairline
●
-
Painted copper plate
●
●
Stainless steel hairline
○
○
Operation STOP switch (with parking function)
○
○
Return-to-reference-floor function
○
○
Cage shelf board addition (1 shelf)
○
-
Power service door
○
○
Service door lock
○
○
Cage, weight emergency stop unit
○
○
Item
Table
Stainless steel construction
Service functions
● : Basic specifications ○ : Optional (additional fee) specifications
Safety
p
Floor Type
RL
Power supply
UP/DOWN distance
Operation STOP & parking function
Table Type
RT
a
g
e
7
p
a
g
e
8
The operating panel is shown in the horizontally oriented type for shutdown (4).
Talk indicator
Talk button
Call indicator
Call button Floor indicator
Error code display
End button
Stop button
Energy-saving
mode release
button
UP/DOWN indicator
Volume button
Operation
Description
Operation of
each section
on the operating panel
Pin
microphone
Service
indicator
Speaker
Station indicator
Station selective button
Door-close
indicator
Interphone Operation Section
Sending/Calling button
Indicator Section
Dumbwaiter Operation Section
Automatic energy-saving mode
The operation panel's indicator lamps are switched OFF and the energy-saving mode (control power OFF) is automatically established if
the dumbwaiter is not operated within 10 minutes after the Service indicator lamp switches OFF.
To resume dumbwaiter operation from this status, simply press the Energy-saving mode release button.
* The energy-saving mode is disabled when an error is active (when an error No. is displayed)
* The energy-saving mode is automatically established when the dumbwaiter is not in use, even if the interphone is in use or a standby status exists.
1
Operation of Each Section on the Operating Panel
Dumbwaiter operation section
Function
Item
Sending/Calling button
(your floor is indicated in yellow.)
Stop button
2
● Calls or sends the car.
● The target floor name in the indicator section flickers when registered.
● Stops the car when the car senses an error during operation.
● The“E0”lamp in the error code display turns on while the button is pressed.
Indicator Section
Function
Item
: Indicates the car is upward.
: Indicates the car is downward.
Travel indicator (orange)
Floor indicator (red)
Error code display (red)
Door-close indicator (green)
Service indicator (yellow)
3
: Indicates the name of the floor where the car is stopped.
: Indicates the target floor name while the car is traveling.
ON
Flicker
E0 to E9 and EA, Eb : Indicates an error occurred.
●Indicates that the service door and car door are fully closed.
●Indicates that the service door is open, or that the car is in operation.
Interphone operation section
Item
Station selective button
(indicator: red)
Function
●Talk with the target floor.
●The indicator turns on when the station is selected.
Call button (indicator: red)
●Sounds in tremolo on the selected floor. (This button also allows you to call the selected floor by voice.)
●The indicator turns on while the call button is pressed.
Talk button (indicator: red)
●Switches the talk mode from hands-free to press-talk.
●The indicator turns on in press-talk mode. (The indicator turns off in hands-free talk mode.)
●The indicator turns on when the interphone is in use in an area other than your station.
End button
Volume button
Speaker
Pin Microphone
●Ends talking.
●Adjust the volume of the call, talk, and auto announcement sound to one of three levels,
in the order of low R medium R high.
●Sounds call, talk, and auto announcement.
●Picks up voices. (The microphone is highly sensitive and does not require proximity during talking.)
WORKS NOT INCLUDED IN INSTALLATION CONTRACT
NOTES
1.THE CONSTRUCTION WORKS OF HOISTWAY AND MACHINE ROOM.
2.HOLES OF MACHINE ROOM FLOOR AND OPENINGS OF EACH FLOOR.
3.MACHINE ROOM ENTRANCE.
4.OPENING FOR CARRYING CONTROL PANEL AND MACHINE,AND THEIR POURING.
5.PIT WATERPROOF WORKS.
6.WIRINGS FOR POWER SUPPLY INCLUDING EARTHING TO POWER RECEIVING BOX IN MACHINE ROOM.
7.WIRING FOR SIGNAL POWER SUPPLY TO POWER RECEIVING BOX IN MACHINE ROOM.
8.ILLUMINATION EQUIPMENT WORKS IN MACHINE ROOM AND ELECTRIC OUTLET FOR INSPECTION.
9.IF A GROUND FAULT INTERRUPTER IS USED AS THE CIRCUIT BREAKER,SET THE CURRENT SENSITIVITY TO 100 mA OR GREATER.
1.VOLTAGE FLUCTUATION SHAL BE WITHIN +5%∼-10%
2.THE FOLLOWING CONDITIONS ARE REQUIRED FOR MAINTAINING THE PREDETERMINED PERFORMANCE.
(1)ENSURE THAT A 0℃ TO 40℃ TEMPERATURE IS MAINTAINED IN THE MACHINE ROOM AND THE UP/DOWN PASSAGEWAY,
WITH THE AVERAGE MONTHLY HUMIDITY NOT EXCEEDING 90%, AND THE AVERAGE DAILY HUMIDITY NOT EXCEEDING 95%.
(2)MOISTURE SHOULD BE BELOW 90% ON A MONTHLY AVERAGE AND BELOW 95% ON A DAILY AVARAGE.
(3)MACHINE ROOM AND THE HOISTWAY SHOULD BE FREE OF DUST OR HARMFUL GAS.
3.THE TUBE APPARATUSES FOR ELECTRICITY OR WARTER SUPPLY SHALL NOT BE BURIED INTO HOISTWAY WALL.
p
a
g
e
9
p
a
g
e
10
Table
Table Type
Type // Floor
Floor Type
Type
http://www.resco.co.jp/ryodenlift/
NAGOYA WORKS:1‐25 NISHIMATABEICHO.
MINAMI - KU. NAGOYA.AICHI 457 - 0835 JAPAN
TEL. : +81‐52‐618‐3260
Published: Nov e m b e r 2014
The contents of the document herein are subject to change without notice.
p
a
g
e
5