Leuze electronic - Galco Industrial Electronics

Leuze electronic
RK 96
Retro-reflective photoelectric sensors
Dimensioned drawing
18m
20-230 V
AC / DC
A2 LS
z Retro-reflective photoelectric sensor with a
large operating range
z Robust plastic housing, protection class
IP 67 for industrial application
z All-mains design 20 … 230VAC/DC with
relay output
z Relay with change-over contact, sensitivity
adjustment and delay before start-up for
optimal adaptation to the application
z Connection via comfortable terminal compartment up to 1.5mm²
We reserve the right to make changes • 96_b02e.fm
ISO
9001
IEC 60947...
C
UL
A
B
C
D
E
F
G
H
Indicator diode green
Indicator diode yellow
Optical axis
Screwed cable gland M16x1.5 for Ø 5 … 10mm
Countersinking for SK nut M5, 4.2 deep
Connection terminals
Cable entry
Sensitivity adjustment
US
Electrical connection
LISTED
IEC 60947...
IP 67
Accessories:
(available separately)
z Mounting systems
(BT 96, UMS 96, BT 450.1-96)
z Spark extinction
z Reflectors
z Reflective tapes
Leuze electronic GmbH + Co. KG
www.leuze.de
Post-box 1111 D-73277 Owen-Teck Tel. +49 7021 5730
RK 96 K/R-1560-25 - 06
Leuze electronic
RK 96
Specifications
Tables
Optical data
18m
see tables
LED (modulated light)
880nm (infrared)
Timing
Switching frequency
Response time
Delay before start-up
20Hz
25ms
≤ 200ms
Electrical data
Operating voltage UB
Power consumption
Switching output 3)
Function characteristics
Switching voltage, relay
Switching current, relay
Switching power, relay
Sensitivity
20 … 230VAC, 50/60Hz
20 … 230VDC
≤ 1.5VA
relay, 1 change-over contact
break-contact/make-contact
250VAC/DC
250VAC, 3A/30VDC, 3A
750VA, cosϕ=1
adjustable
Mechanical data
Housing
Optics cover
Weight
Connection type
ready
light path free
light path free, no performance reserve
1)
2)
3)
4)
5)
1
2
3
4
5
6
TK(S) 100x100
MTK(S) 50x50
TK(S)
30x50
TK(S)
20x40
TK(S)
82
Tape 2 100x100
0.3 … 15m
0.3 … 11m
0.3 … 6m
0.3 … 5m
0.3 … 11m
0.3 … 6m
1
2
3
4
5
6
0.1
0.1
0.1
0.1
0.1
0.1
15
6
6
5
6
18
11
7.1
12
11
8
12
TK …
TKS …
Tape 2
= adhesive
= screw type
= adhesive
Plastic housing
polycarbonate
plastic
150g
terminals
Diagrams
Typ. response behaviour (TKS 100x100)
Environmental data
Ambient temp. (operation/storage)
Protective circuit 4)
VDE safety class 5)
Protection class
LED class
Standards applied
Operating
range
Operating range [m]
Typ. operating range limit [m]
Indicators
LED green
LED yellow
LED yellow flashing
Reflectors
-20°C … +55°C/-40°C … +55°C
1, 4
II, all-insulated
IP 67
1 (acc. to EN 60825-1)
IEC 60947-5-2
Typ. operating range limit: max. attainable range without performance reserve
Operating range: recommended range with performance reserve
Suitable spark extinction must be provided with inductive or capacitive loads
1=transient protection, 4=interference blanking
Rating voltage 250VAC
Misalignment y [mm]
Typ. operating range limit (TK(S) 100x100) 1)
Operating range 2)
Light source
Wavelength
250
200
150
100
50
0
-50
-100
-150
-200
-250
y2
y1
0
5
10
15
20
Distance x [m]
y2
y1
x
Order guide
RK 96 K/R-1560-25 - 06
Remarks
Designation
Part No.
RK 96K/R-1560-25
RK 96K/R-156P-25
500 80484
500 30404
z PRK 96 K/R-156P-25
P = Reduction M16
0603