Copper Meter Setters 11/12

Copper
Meter
Setters
To Set 5/8", 5/8" x 3/4", 3/4",
1", 1 1/2" & 2" Water Meters
11/12
Table of Contents
A.Y. McDonald Mfg. Co. is pleased to present its extensive line of copper meter setters, resetters and tandem setters. These fine,
high quality products offer the user greater versatility due to the wide variety of end connections, heights, valve options, sizes and
special configurations.
Versatility. That's the theme of our complete and flexible line of copper meter setters. It also describes our system of model numbers.
If you have requirements that are not contained in this catalog, please contact our customer service department at 1-800-2922737. Our professional staff will be happy to work with you to select the product that will fit your needs.
Page
Page
General Information.....................................................2-3
Meter Dimensions.......................................................... 3
Series 728
Integral MNPT x Integral MNPT............................... 20-21
Meter Setters - 5/8", 5/8" x 3/4", 3/4", & 1"
Series 729
Integral Flare x Integral Flare.................................. 22-23
Horizontal Inlet and Outlet
Vertical Inlet and Outlet
Series 720
Double Purpose x Double Purpose...............................4-5
Series 730
Double Purpose x Double Purpose.......................... 24-25
Series 721
Integral CTS, PEP, or C903 Compression......................6-7
Series 731
Integral CTS, PEP, or C903 Compression................. 26-27
Series 722
Integral CTS, PEP, PVC, IP Compression........................8-9
Series 732
Integral CTS, PEP, PVC, IP Compression................... 28-29
Series 723
Double Purpose x Integral CTS, PEP, or
C903 Compression................................................. 10-11
Series 737
Integral Flare x Integral Flare.................................. 30-31
Series 724
Integral CTS, PEP, or C903 Compression x
Double Purpose...................................................... 12-13
Series 725
Double Purpose x Integral CTS, PEP, PVC, or
IP Compression...................................................... 14-15
Series 726
Integral CTS, PEP, PVC, or IP Compression x
Double Purpose...................................................... 16-17
Series 727
Special "K" Thread x "K" Thread................................... 18
"K" Style - Valves & Fittings......................................... 19
Series 738
Integral MNPT x Integral MNPT............................... 32-33
Series 739
Integral Flare x Double Purpose.............................. 34-35
Series 760 - 763
Horizontal "F" Style................................................ 36-37
Series 764
Low Rise "F" Style.................................................. 38-39
Series 770
Integral CTS Compression x Double
Purpose.................................................................. 40-41
Meter Dimensions
3/4" Short Meter,
Meter Size
5/8"
5/8" x 3/4"
3/4"
A-Meter Threads
3/4"
1"
1"
B-Lay Length
7 1/2"
7 1/2"
9"
A.Y. McDonald Spacing* 7 13/16"
7 13/16"
9 5/16"
3/4" x 1"
1"
1 1/4"
1 1/4"
9"
10 3/4"
9 5/16"
11 3/32"
*Allows for meter and two gaskets.
2
800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com
11-12
Table of Contents
Page
Page
Meter Setters - 11⁄2" & 2"
Series 731
Integral Q/T CTS Compression...................................... 51
Series 720
No Rise - FNPT x MNPT................................................. 42
FNPT Inlet x FNPT Outlet............................................... 43
Series 721
Integral CTS Compression............................................. 44
Series 722
Integral -22 CTS Compression...................................... 45
Series 723
FNPT x Integral Q/T CTS Compression.......................... 46
Series 724
Integral Q/T CTS Compression x FNPT.......................... 47
Series 725
FNPT x Integral -22 CTS Compression........................... 48
Series 732
Integral -22 CTS Compression...................................... 52
Series 739
CTS Compression......................................................... 53
Unions | Setters | Tandem Style
Unions ......................................................................... 54
Setters & Resetters 1 1/2" & 2".................................. 56
Tandem Styles / Options........................................ 57-58
Setters with Bypass...................................................... 58
Accessories
Idlers............................................................................ 55
Gaskets........................................................................ 55
Series 726
Integral -22 CTS Compression x FNPT........................... 49
Series 730
FNPT x FNPT................................................................. 50
GENERAL INFORMATION
- Brass materials meet or exceed AWWA C-800 (latest revision)
- Copper tubing has a 13/16" O.D. for 5/8", 5/8" x 3/4" or 3/4" meter setters, 1 1/8" O.D. for 1" meter setters, 1 5/8" for 1 1/2" meter setters and 2 1/8" for 2" meter setters.
- Meter swivel nuts with meter support saddle are standard, except on tandem style meter setters.
- All copper meter setters can be supplied with a test valve on the outlet tubing.
- Solder is no-lead.
- For dual check backflow valves, see Dual Check Section.
- EPDM rubber gaskets are furnished as standard. Contact factory for fiber or leather gaskets.
- Brace eye hole accepts 1/2" iron pipe or PVC for 5/8", 5/8" x 3/4" and 3/4" meters and 1" vertical meter setters.
- All meter setters are factory tested air under water at 85 PSIG.
- Brace eye hole accepts 3/4" iron pipe for PVC for 1", horizontal meter setters.
- Brass support bar is standard on 18" and higher meter setters.
- Meter setter heights over 24" available on special order.
- All meter swivel nuts have wire seal hole.
- Brace eye hole accepts 1" iron pipe or PVC for 1 1/2" & 2", horizontal meter setters.
- Lockwing ball style meter valves are standard.
11-12
800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com
3
Copper Meter Setters
720 SERIES
FOR 5/8", 5/8" x 3/4", or 3/4" METERS | Horizontal Style, Double Purpose Union x Double Purpose Union
Setters normally supplied with Double Purpose End Connections. See Page 56 to order end connections separately.
To order 720 Series: Model No. 720-207WXDD
720
-
2
07
33
above means:
INLET OUTLET
INLET OUTLET
WX
DD
33
Series
Style
Meter Size
Meter Height
Inlet and Outlet Valves Type of connection Blank Space Size Inlet & Outlet
Inlet and Outlet
Series 720
1
=
5/8"
07
=
7"
720
1 = 1/2"
– = Standard
C= Full Port Angle Single 2 = 5/8" x 3/4" 09 = 9"
Standard
3 = 3/4"
12 = 12"
Check Valve
3 = 3/4"
4 = 1"
15 = 15"
D=
Full
Port
Angle
Dual
18 = 18"
Check Valve (ASSE 1024)
21 = 21"
W= Angle Lockwing Ball C = Copper Flare Union (3/4" or 1")
24 = 24"
D = Double Purpose Union (Flare or FNPT) (3/4" or 1")
27 = 27"
Valve rated at 300 PSIG
X = Flanged Tubing with F = FNPT Union (1/2" or 1")
Additional
18" & Taller includes
G = G CTS McGrip Compression Union (3/4")
Meter Nut
heights
available,
Brace Support Bar
contact factory For other special meter
J = C903 Compression Union (3/4")
connections, contact factory.
M= MNPT Union (3/4", 1", or 1 1/4")
Q = Q CTS McQuick Compression Union (3/4")
S = Solder Union (3/4" or 1")
Series 750 - Tandem
For Tandem Series
T = T CTS Compression Union (3/4" or 1")
A = Full Port Angle Single Z = -3Q PEP McQuick Compression Union (3/4")
Check Valve
2 = -22 CTS MacPak Compression Union (3/4" or 1")
F = Full Port Angle Dual 3 = -33 PEP MacPak Compression Union (3/4")
Check Valve (ASSE 1024)
4 = -44 PVC MacPak Compression Union (3/4")
750
N = Flanged Tubing with 5 = -55 IP MacPak Compression Union (3/4")
Series
Meter Nut
Horizontal
Q = Angle Lockwing Ball
Tandem
Example
750-207QNDD
33
Valve Rated at 300 PSIG
Setter
Tandem setters are supplied with
adapters and “S” tube. Please specify
device length and threads when ordering.
NOTE: Unless specified all tandem components have meter nut without saddles.
OPTIONS
-Assemblies shipped with two 1/8" EPDM rubber meter gaskets, and two union nut gaskets.
-Insert stiffeners are required on all flexible plastic connections.
-Not all combinations available, contact factory with your requirements.
-Most Meter Setters are Made to order and are not returnable.
-Please verify with the factory that the model number you have configured is available and meets your requirements.
4
800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com
11-12
Copper Meter Setters
720 SERIES
1 " METERS | Horizontal Style, Double Purpose Union x Double Purpose Union
Setters normally supplied with Double Purpose End Connections. See Page 56 to order end connections separately.
To order 720 Series: Model No. 720-410WXDD
720
-
4
10
44
above means:
INLET OUTLET
INLET OUTLET
WX
DD
44
Series
Style
Meter Size
Meter Height
Inlet and Outlet Valves Type of connection Blank Space Size Inlet & Outlet
Inlet and Outlet
Series 720
4= 1"
4 = 1"
10 = 10"
–
=
Standard
720
C= Full Port Angle Single 12 = 12"
Standard
Check Valve
15 = 15"
18 = 18"
D= Angle Dual Check Valve 21 = 21"
(ASSE 1024) D = Double Purpose Union (Flare or FNPT) (1")
24 = 24"
12 minimum height
M= MNPT Union (1" or 1 1/4")
27 = 27"
J = Full Port Angle Lockwing S = Solder Union (1")
Additional
Ball Valve 300 PSIG
heights available,
18" & Taller includes
M= Full Port Angle Dual contact
factory
Brace Support Bar
Valve (ASSE 1024)
W= Angle Lockwing Ball Valve rated at 300 PSIG
X = Flanged Tubing with Meter Nut
For other special meter
connections, contact factory.
For Tandem Series
750
Series
Horizontal
Tandem
Setter
Example 750-412QNDD 44
Tandem setters are supplied with
adapters and “S” tube. Please specify
device length and threads when ordering.
12" minimum height
Series 750 - Tandem
A = Full Port Angle Single Check Valve
F = Angle Dual Check Valve (ASSE 1024)
K= Full Port Angle Lockwing Ball Valve 300 PSIG
N = Flanged Tubing with Meter Nut
P = Full Port Angle Dual
Valve (ASSE 1024)
Q = Angle Lockwing Ball
Valve Rated at 300 PSIG
NOTE: Unless specified all tandem components have meter nuts without saddles.
OPTIONS
-Assemblies shipped with two 1/8" EPDM rubber meter gaskets, and two union nut gaskets.
-Insert stiffeners are required on all flexible plastic connections.
-Not all combinations available, contact factory with your requirements.
-Most Meter Setters are Made to order and are not returnable.
-Please verify with the factory that the model number you have configured is available and meets your requirements.
11-12
800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com
5
Copper Meter Setters
721 SERIES
FOR 5/8", 5/8" x 3/4", or 3/4" METERS | Horizontal Style, Integral CTS, PEP or C903 Compression In & Out
Compression Connections - B, G, H, J, Q, T, Y, Z Inlet/Outlet
To order 721 Series Model No. 721-207WXTT
721
-
2
07
33
above means:
INLET OUTLET
INLET OUTLET
WX
TT
33
Series
Style
Meter Size
Meter Height
Inlet and Outlet Valves Type of connection Blank Space Size Inlet & Outlet
Inlet and Outlet
Series 721
721
07 = 7"
– = Standard
1 = 5/8"
3 = 3/4"
C= Full Port Angle Single Standard
2 = 5/8" x 3/4" 09 = 9"
4 = 1"
Check Valve
12 = 12"
3 = 3/4"
5 = 1 1/4"
D= Full Port Angle Dual 15 = 15"
Check Valve (ASSE 1024)
18 = 18"
B = -3G PEP McGrip Compression Integral
21 = 21"
W= Angle Lockwing Ball (3/4", 1", 3/4" x 1", 1" x 3/4")
Valve rated at 300 PSIG
24 = 24"
G = G CTS McGrip Compression Integral
27 = 27"
X = Flanged Tubing with 18" & Taller includes
(3/4", 1", 1 1/4", 3/4" x 1", 1" x 3/4", Meter
Nut
Additional
1" x 1 1/4", or 1 1/4" x 1")
Brace Support Bar
heights available, For other special meter H = H CTS PE Handyloc Compression Integral
contact factory
connections, contact factory.
(3/4", 1", 3/4" x 1", 1" x 3/4")
J = C903 Compression Integral (3/4", 1", 3/4" x 1", 1" x 3/4")
For Tandem Series
Series 751 - Tandem
Q = Q CTS McQuick Compression Integral
(3/4", 1", 1 1/4", 3/4" x 1", 1" x 3/4", A = Full Port Angle Single 1"x 1 1/4", or 1 1/4" x 1")
Check Valve
T = T CTS Compression Integral F = Full Port Angle Dual (3/4", 1", 1 1/4", 3/4" x 1", 1" x 3/4", Check Valve (ASSE 1024)
1" x 1 1/4", or 1 1/4" x 1")
751
N = Flanged Tubing with Series
Y = -3H PEP Handyloc Compression Integral
Meter Nut
Horizontal
(3/4", 1", 3/4" x 1", 1" x 3/4")
Q
=
Angle
Lockwing
Ball
Tandem
Valve Rated at 300 PSIG Z = -3Q PEP McQuick Compression Integral Setter
Example 751-207QNTT 33
(3/4", 1", 3/4" x 1", 1" x 3/4")
Tandem setters are supplied with
adapters and “S” tube. Please specify
device length and threads when ordering.
NOTE: Unless specified all tandem components have meter nuts without saddles.
OPTIONS
-Assemblies shipped with two 1/8" EPDM rubber meter gaskets.
-Insert stiffeners are required on all flexible plastic connections.
-Not all combinations available, contact factory with your requirements.
-Most Meter Setters are Made to order and are not returnable.
-Please verify with the factory that the model number you have configured is available and meets your requirements.
6
800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com
11-12
Copper Meter Setters
721 SERIES
1" METERS | Horizontal Style, Integral CTS, PEP or C903 Compression In & Out
Compression Connections - B, G, H, J, Q, T, Y, Z Inlet/Outlet
To order 721 Series: Model No. 721-410WXTT
721
-
4
10
44
above means:
INLET OUTLET
INLET OUTLET
WX
TT
44
Series
Style
Meter Size
Meter Height
Inlet and Outlet Valves Type of connection Blank Space Size Inlet & Outlet
Inlet and Outlet
Series 721
721
10 = 10"
4 = 1"
4 = 1"
Standard
– = Standard
12 = 12"
C= Full Port Angle Single 5 = 1 1/4"
15 = 15"
Check Valve
6 = 1 1/2"
18 = 18"
D= Angle Dual Check Valve
21 = 21"
B = -3G PEP McGrip Compression Integral (1")
(ASSE 1024) 24 = 24"
12 minimum height
G = G CTS McGrip Compression Integral 27 = 27"
(1", 1 1/4", 1 1/2")
J = Full Port Angle Lockwing Additional
Ball Valve 300 PSIG
H = H CTS PE Handyloc Compression Integral (1")
heights available,
18" & Taller includes
M= Full Port Angle Dual
J = C903 Compression Integral (1")
contact factory
Brace Support Bar
Q = Q CTS McQuick Compression Integral Valve (ASSE 1024)
(1", 1 1/4", 1 1/2")
W= Angle Lockwing Ball T = T CTS Compression Integral (1", 1 1/4", 1 1/2")
Valve rated at 300 PSIG
Y = -3H PEP Handyloc Compression Integral (1")
X = Flanged Tubing with Meter Nut
Z = -3Q PEP McQuick Compression Integral (1")
For other special meter connections,
contact factory.
For Tandem Series
751
Series
Horizontal
Tandem
Setter
Example 751-412QNTT 44
Tandem setters are supplied with
adapters and “S” tube. Please specify
device length and threads when ordering.
12" minimum height
Series 751 - Tandem
A = Full Port Angle Single Check Valve
F = Angle Dual Check Valve (ASSE 1024)
K= Full Port Angle Lockwing Ball Valve 300 PSIG
N = Flanged Tubing with Meter Nut
P = Full Port Angle Dual Valve (ASSE 1024)
Q = Angle Lockwing Ball Valve Rated at 300 PSIG
NOTE: Unless specified all tandem components have meter nuts without saddles.
OPTIONS
-Assemblies shipped with two 1/8" EPDM rubber meter gaskets.
-Insert stiffeners are required on all flexible plastic connections.
-Not all combinations available, contact factory with your requirements.
-Most Meter Setters are Made to order and are not returnable.
-Please verify with the factory that the model number you have configured is available and meets your requirements.
11-12
800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com
7
Copper Meter Setters
722 SERIES
FOR 5/8", 5/8" x 3/4", or 3/4" METERS
Horizontal Style, Integral -22 CTS, -33 PEP, -44 PVC, or -55 IP Compression Inlet & Outlet
To order 722 Series Model No. 722-207WX22
722
-
2
07
33 above means:
INLET OUTLET
INLET OUTLET
WX
22
33
Series
Style
Meter Size
Meter Height
Inlet and Outlet Valves Type of connection Blank Space Size Inlet & Outlet
Inlet and Outlet
Series 722
722
07 = 7"
3 = 3/4"
1 = 5/8"
Standard
4 = 1"
– = Standard
C= Full Port Angle Single 2 = 5/8" x 3/4" 09 = 9"
5 = 1 1/4"
12 = 12"
Check Valve
3 = 3/4"
15 = 15"
D= Full Port Angle Dual 18 = 18"
Check Valve (ASSE 1024)
2 = -22 CTS MacPak Compression Integral
21 = 21"
(3/4", 1", 1 1/4", 3/4" x 1", 1" x 3/4",
W=
Angle
Lockwing
Ball
24 = 24"
Valve rated at 300 PSIG
1" x 1 1/4", or 1 1/4" x 1")
27 = 27"
18" & Taller includes
X = Flanged Tubing with 3 = -33 PEP MacPak Compression Integral
Additional
Brace Support Bar
heights available, Meter Nut
(3/4", 1", 3/4" x 1", 1" x 3/4")
contact factory
4 = -44 PVC MacPak Compression Integral
For other special meter connections, contact factory.
(3/4", 1", 3/4" x 1", 1" x 3/4")
5 = -55 IP MacPak Compression Integral
(3/4", 1", 3/4" x 1", 1" x 3/4")
For Tandem Series
Series 752 - Tandem
752
Series
Horizontal
Tandem
Setter
Example 752-207QN22 33
Tandem setters are supplied with
adapters and “S” tube. Please specify
device length and threads when ordering.
A = Full Port Angle Single Check Valve
F = Full Port Angle Dual Check Valve (ASSE 1024)
N = Flanged Tubing with Meter Nut
Q = Angle Lockwing Ball
Valve Rated at 300 PSIG
NOTE: Unless specified all tandem components have meter nuts without saddles.
OPTIONS
-Assemblies shipped with two 1/8" EPDM rubber meter gaskets.
-Insert stiffeners are required on all flexible plastic connections.
-Not all combinations available, contact factory with your requirements.
-Most Meter Setters are Made to order and are not returnable.
-Please verify with the factory that the model number you have configured is available and meets your requirements.
8
800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com
11-12
Copper Meter Setters
722 SERIES
1" METERS
Horizontal Style, Integral -22 CTS, -33 PEP, -44 PVC, or -55 IP Compression Inlet & Outlet
To order 722 Series Model No. 722-410WX22
722
-
4
10
44 above means:
INLET OUTLET
INLET OUTLET
WX
22
44
Series
Style
Meter Size
Meter Height
Inlet and Outlet Valves Type of connection Blank Space Size Inlet & Outlet
Inlet and Outlet
Series 722
722
10 = 10"
4 = 1"
4 = 1"
Standard
5 = 1 1/4"
C= Full Port Angle Single Check Valve
– = Standard
12 = 12"
6 = 1 1/2"
15 = 15"
D= Angle Dual Check Valve 18 = 18"
(ASSE 1024) 12 minimum height
21 = 21"
2 = -22 CTS MacPak Compression Integral
24 = 24"
J = Full Port Angle Lockwing (3/4", 1", 1 1/4", 1 1/2")
27 = 27"
Ball Valve 300 PSIG
3 = -33 PEP MacPak Compression Integral (1")
Additional
M= Full Port Angle Dual
18" & Taller includes
4 = -44 PVC MacPak Compression Integral (1")
heights available, Valve (ASSE 1024)
Brace Support Bar
contact factory
5 = -55 IP MacPak Compression Integral (1")
W= Angle Lockwing Ball Valve rated at 300 PSIG
X = Flanged Tubing with Meter Nut
For other special meter
connections, contact factory.
For Tandem Series
752
Series
Horizontal
Tandem
Setter
Example 752-412QN22 44
Tandem setters are supplied with
adapters and “S” tube. Please specify
device length and threads when ordering.
12" minimum height
Series 752 - Tandem
A = Full Port Angle Single C
heck Valve
F = Angle Dual Check Valve
(ASSE 1024)
K= Full Port Angle Lockwing Ball Valve 300 PSIG
N = Flanged Tubing with Meter Nut
P = Full Port Angle Dual Valve (ASSE 1024)
Q = Angle Lockwing Ball
Valve Rated at 300 PSIG
NOTE: Unless specified all tandem components have meter nuts without saddles.
OPTIONS
-Assemblies shipped with two 1/8" EPDM rubber meter gaskets.
-Insert stiffeners are required on all flexible plastic connections.
-Not all combinations available, contact factory with your requirements.
-Most Meter Setters are Made to order and are not returnable.
-Please verify with the factory that the model number you have configured is available and meets your requirements.
11-12
800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com
9
Copper Meter Setters
723 SERIES
FOR 5/8", 5/8" x 3/4", or 3/4" METERS
Horizontal Style, Double Purpose Union Inlet x Integral CTS, PEP or C903 Compression - B, G, H, J, Q, T, Y, Z Outlet
Setters normally supplied with Double Purpose End Connections. See Page 56 to order end connections separately.
To order 723 Series Model No. 723-207WXDT
723
-
2
07
33
above means:
INLET OUTLET
INLET OUTLET
WX
DT
33
Series
Style
Meter Size
Meter Height
Inlet and Outlet Valves Type of connection Blank Space Size Inlet & Outlet
Inlet and Outlet
Series 723
723
1 = 1/2"
– = Standard
07 = 7"
1 = 5/8"
Standard
3 = 3/4"
2 = 5/8" x 3/4" 09 = 9"
C= Full Port Angle Single 12 = 12"
4 = 1"
3 = 3/4"
Check Valve
Inlet
Connections
15 = 15"
D= Full Port Angle Dual C = Copper Flare Union (3/4" or 1")
18 = 18"
Check Valve (ASSE 1024)
21 = 21"
D = Double Purpose Union (Flare or FNPT) (3/4")
24 = 24"
W= Angle Lockwing Ball F = FNPT Union (1/2" or 1")
27 = 27"
Valve rated at 300 PSIG
G = G CTS McGrip Compression Union (3/4")
Additional
X = Flanged Tubing with 18" & Taller includes
J = C903 Compression Union (3/4")
heights
available,
Meter
Nut
Brace Support Bar
contact factory
M= MNPT Union (3/4", 1" or 11⁄4")
For other special meter
Q
= Q CTS McQuick Compression Union (3/4")
connections, contact factory.
S = Solder Union (3/4" or 1")
T = T CTS Compression Union (3/4" or 1")
For Tandem Series
Z = -3Q PEP McQuick Compression Union (3/4")
Series 753 - Tandem
A = Full Port Angle Single 2 = -22 CTS MacPak Compression Union (3/4" or 1")
3 = -33 PEP MacPak Compression Union (3/4")
Check Valve
F = Full Port Angle Dual 4 = -44 PVC MacPak Compression Union (3/4")
Check Valve (ASSE 1024)
5 = -55 IP MacPak Compression Union (3/4")
753
N = Flanged Tubing with Series
Meter Nut
Outlet Connections
Horizontal
Q = Angle Lockwing Ball
B = -3G PEP McGrip Compression Integral (3/4")
Tandem
Example 753-207QNDT 33
Setter
Valve
Rated
at
300
PSIG
G = G CTS McGrip Compression Integral (3/4", 1", or 1 1/4")
Tandem setters are supplied with
adapters and “S” tube. Please specify
NOTE: Unless specified all tandem H = H CTS PE Handyloc Compression Integral (3/4"or 1")
device length and threads when ordering.
components have meter nuts J = C903 Compression Integral (3/4")
without saddles.
Q = Q CTS McQuick Compression Integral (3/4", 1", or 1 1/4")
T = T CTS Compression Integral (3/4", 1", or 1 1/4")
Y = -3H PEP Handyloc Compression Integral (3/4"or 1")
Z = -3Q PEP McQuick Compression Integral (3/4", or 1")
OPTIONS
-Assemblies shipped with two 1/8" EPDM rubber meter gaskets and two union nut gaskets.
-Insert stiffeners are required on all flexible plastic connections.
-Not all combinations available, contact factory with your requirements.
-Most Meter Setters are Made to order and are not returnable.
-Please verify with the factory that the model number you have configured is available and meets your requirements.
10
800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com
11-12
Copper Meter Setters
723 SERIES
1" METERS
Horizontal Style, Double Purpose Union Inlet x Integral CTS, PEP or C903 Compression - B, G, H, J, Q, T, Y, Z Outlet
Setters normally supplied with Double Purpose End Connections. See Page 56 to order end connections separately.
To order 723 Series Model No. 723-410WXDT
723
-
4
10
44
above means:
INLET OUTLET
INLET OUTLET
WX
DT
44
Series
Style
Meter Size
Meter Height
Inlet and Outlet Valves Type of connection Blank Space Size Inlet & Outlet
Inlet and Outlet
4 = 1"
Series 723
723
– = Standard
10 = 10"
4 = 1"
12 = 12"
Standard
C= Full Port Angle Single Inlet Connections
15 = 15"
Check Valve
18 = 18"
D= Angle Dual Check Valve D = Double Purpose Union (Flare or FNPT) (3/4")
21 = 21"
1
(ASSE 1024) M= MNPT Union (3/4",1", or 1 ⁄4")
24 = 24"
12
minimum
height
S
=
S
older
Union
(3/4"
or
1")
27 = 27"
J = Full Port Angle Lockwing Additional
18" & Taller includes
heights available, Ball Valve 300 PSIG
Outlet Connections
Brace Support Bar
contact factory
M= Full Port Angle Dual Valve B = -3G PEP McGrip Compression Integral (1")
(ASSE 1024)
G = G CTS McGrip Compression Integral (1", 1 1/4")
W= Angle Lockwing Ball H = H CTS PE Handyloc Compression Integral (1")
Valve rated at 300 PSIG
J = C903 Compression Integral (1")
X = Flanged Tubing with M
eter Nut Q = Q CTS McQuick Compression Integral (1", 1 1/4")
For other special meter T = T CTS Compression Integral (1", 1 1/4")
connections, contact factory.
Y = -3H PEP Handyloc Compression Integral (1")
Z = -3Q PEP McQuick Compression Integral (1")
Series
753
Tandem
For Tandem Series
A = Full Port Angle Single Check Valve
F = Angle Dual Check Valve (ASSE 1024)
K= Full Port Angle Lockwing 753
Ball Valve 300 PSIG
Series
N = Flanged Tubing with M
eter Nut
Horizontal
P = Full Port Angle Dual Valve Tandem
(ASSE 1024)
Example 753-412QNDT 44
Setter
Tandem setters are supplied with
Q = Angle Lockwing Ball Valve adapters and “S” tube. Please specify
Rated at 300 PSIG
device length and threads when ordering.
12" minimum height
NOTE: Unless specified all tandem components have meter nuts without saddles.
OPTIONS
-Assemblies shipped with two 1/8" EPDM rubber meter gaskets and two union nut gaskets.
-Insert stiffeners are required on all flexible plastic connections.
-Not all combinations available, contact factory with your requirements.
-Most Meter Setters are Made to order and are not returnable.
-Please verify with the factory that the model number you have configured is available and meets your requirements.
11-12
800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com
11
Copper Meter Setters
724 SERIES
FOR 5/8", 5/8" x 3/4", or 3/4" METERS
Horizontal Style, Integral CTS, PEP or C903 Compression - B, G, H, J, Q, T, Y, Z Inlet x Double Purpose Union Outlet
Setters normally supplied with Double Purpose End Connections. See Page 56 to order end connections separately.
To order 724 Series Model No. 724-207WXTD
724
-
2
07
33
above means:
INLET OUTLET
INLET OUTLET
WX
TD
33
Series
Style
Meter Size
Meter Height
Inlet and Outlet Valves Type of connection Blank Space Size Inlet & Outlet
Inlet and Outlet
Series 724
1 = 1/2"
724
– = Standard
07 = 7"
1 = 5/8"
3 = 3/4"
Standard
C= Full Port Angle Single 2 = 5/8" x 3/4" 09 = 9"
4 = 1"
12 = 12"
Check Valve
3 = 3/4"
Inlet Connections
15 = 15"
D= Full Port Angle Dual B = -3G PEP McGrip Compression Integral (3/4" or 1")
18 = 18"
Check Valve (ASSE 1024)
G = G CTS McGrip Compression Integral
21 = 21"
W= Angle Lockwing Ball (3/4", 1", or 1 1/4")
24 = 24"
Valve rated at 300 PSIG
H = H CTS PE Handyloc Compression Integral
27 = 27"
Additional
X = Flanged Tubing with (3/4"or 1")
18" & Taller includes
heights available, Meter Nut
J = C903 Compression Integral (3/4" or 1")
Brace Support Bar
contact factory
For other special meter Q = Q CTS McQuick Compression Integral
connections, contact factory.
(3/4", 1", or 1 1/4")
T = T CTS Compression Integral (3/4", 1", or 1 1/4")*
Y = -3H PEP Handyloc Compression Integral
(3/4"or 1")
Series 754 - Tandem
For Tandem Series
Z = -3Q PEP McQuick Compression Integral A = Full Port Angle Single (3/4" or 1")
Check Valve
F = Full Port Angle Dual Outlet Connections
Check Valve (ASSE 1024)
C = Copper Flare Union (3/4" or 1")
N
=
Flanged
Tubing
with
D = Double Purpose Union (Flare or FNPT) (3/4")
754
Meter Nut
F = FNPT Union (1/2" or 1")
Series
Q = Angle Lockwing Ball
G = G CTS McGrip Compression Union (3/4")
Horizontal
Tandem
Example 754-207QNTD 33
Valve Rated at 300 PSIGJ = C903 Compression Union (3/4")
Tandem setters are supplied with
Setter
M= MNPT Union (3/4", 1", or 1 1/4")
adapters and “S” tube. Please specify
Q = Q CTS McQuick Compression Union (3/4")
NOTE:
Unless
specified
all
t
andem
device length and threads when ordering.
components have meter nuts S = Solder Union (3/4" or 1")
without saddles.
T = T CTS Compression Union (3/4" or 1")
Z = -3Q PEP McQuick Compression Union (3/4")
2 = -22 CTS MacPak Compression Union (3/4" or 1")
3 = -33 PEP MacPak Compression Union (3/4")
OPTIONS
4 = -44 PVC MacPak Compression Union (3/4")
5 = -55 IP MacPak Compression Union (3/4")
-Assemblies shipped with two 1/8" EPDM rubber meter gaskets and two union nut gaskets.
-Insert stiffeners are required on all flexible plastic connections.
-Not all combinations available, contact factory with your requirements.
-Most Meter Setters are Made to order and are not returnable.
-Please verify with the factory that the model number you have configured is available and meets your requirements.
12
800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com
11-12
Copper Meter Setters
724 SERIES - 1" Meter
1" METERS
Horizontal Style, Integral CTS, PEP or C903 Compression - B, G, H, J, Q, T, Y, Z Inlet x Double Purpose Union Outlet
Setters normally supplied with Double Purpose End Connections. See Page 56 to order end connections separately.
To order 724 Series Model No. 724-410WXTD
724
-
4
10
44
above means:
INLET OUTLET
INLET OUTLET
WX
TD
44
Series
Style
Meter Size
Meter Height
Inlet and Outlet Valves Type of connection Blank Space Size Inlet & Outlet
Inlet and Outlet
Series 724
4 = 1"
– = Standard
724
10 = 10"
4 = 1"
Standard
12 = 12"
C= Full Port Angle Single Inlet Connections
15 = 15"
Check Valve
B = -3G PEP McGrip Compression Integral (1")
18 = 18"
D= Angle Dual Check Valve G = G CTS McGrip Compression Integral (1", 1 1/4")
21 = 21"
(ASSE 1024) H = H CTS PE Handyloc Compression Integral (1")
24 = 24"
12 minimum height
27 = 27"
J = C903 Compression Integral (1")
J = Full Port Angle Lockwing Additional
Q = Q CTS McQuick Compression Integral (1", 1 1/4")
18" & Taller includes
Ball
Valve
300
PSIG
heights available,
T = T CTS Compression Integral (1", 1 1/4")
Brace Support Bar
contact factory
M= Full Port Angle Dual
Y = -3H PEP Handyloc Compression Integral (1")
Valve (ASSE 1024)
Z = -3Q PEP McQuick Compression Integral (1")
W= Angle Lockwing Ball Outlet Connections
Valve rated at 300 PSIG
X = Flanged Tubing with D = Double Purpose Union (Flare or FNPT) (1")
M= MNPT Union (1" or 1 1/4")
Meter Nut
S = Solder Union (1")
For other special meter connections, contact factory.
For Tandem Series
754
Series
Horizontal
Tandem
Setter
Example 754-412QNTD 44
Tandem setters are supplied with
adapters and “S” tube. Please specify
device length and threads when ordering.
12" minimum height
Series 754 - Tandem
A = Full Port Angle Single C
heck Valve
F = Angle Dual Check Valve (ASSE 1024)
K= Full Port Angle Lockwing Ball Valve 300 PSIG
N = Flanged Tubing with M
eter Nut
P = Full Port Angle Dual
Valve (ASSE 1024)
Q = Angle Lockwing Ball Valve Rated at 300 PSIG
NOTE: Unless specified all tandem components have meter nuts without saddles.
OPTIONS
-Assemblies shipped with two 1/8" EPDM rubber meter gaskets and two union nut gaskets.
-Insert stiffeners are required on all flexible plastic connections.
-Not all combinations available, contact factory with your requirements.
-Most Meter Setters are Made to order and are not returnable.
-Please verify with the factory that the model number you have configured is available and meets your requirements.
11-12
800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com
13
Copper Meter Setters
725 SERIES
FOR 5/8", 5/8" x 3/4", or 3/4" METERS
Horizontal Style, Double Purpose Union Inlet x Integral CTS, PEP or IP Compression -22, -33, -44, -55 Outlet
Setters normally supplied with Double Purpose End Connections. See Page 56 to order end connections separately.
To order 725 Series Model No. 725-207WXD2
725
-
2
07
33
above means:
INLET OUTLET
INLET OUTLET
WX
D2
33
Series
Style
Meter Size
Meter Height
Inlet and Outlet Valves Type of connection Blank Space Size Inlet & Outlet
Inlet and Outlet
Series 725
725
– = Standard
07 = 7"
1 = 1/2"
1 = 5/8"
Standard
3 = 3/4"
2 = 5/8" x 3/4" 09 = 9"
C= Full Port Angle Single 12 = 12"
Check Valve
4 = 1"
3 = 3/4"
Inlet Connections
15 = 15"
D= Full Port Angle Dual C = Copper Flare Union (3/4" or 1")
18 = 18"
Check Valve (ASSE 1024)
21 = 21"
W= Angle Lockwing Ball D = Double Purpose Union (Flare or FNPT) (3/4")
24 = 24"
F = FNPT Union (1/2" or 1")
Valve rated at 300 PSIG
27 = 27"
G = G CTS McGrip Compression Union (3/4")
X
=
Flanged
Tubing
with
18" & Taller includes
Meter Nut
Additional
J = C903 Compression Union (3/4")
Brace Support Bar
heights available, For other special meter M= MNPT Union (3/4" or 1")
contact factory
connections, contact factory.
Q = Q CTS McQuick Compression Union (3/4" or 1")
S = Solder Union (3/4", 1", or 1 1/4")
T = T CTS Compression Union (3/4" or 1")
For Tandem Series
Series 755 - Tandem
Z = -3Q PEP McQuick Compression Union (3/4")
A = Full Port Angle Single 2 = -22 CTS MacPak Compression Union (3/4" or 1")
Check Valve
3 = -33 PEP MacPak Compression Union (3/4")
F = Full Port Angle Dual 4 = -44 PVC MacPak Compression Union (3/4")
Check Valve (ASSE 1024)
755
N = Flanged Tubing with 5 = -55 IP MacPak Compression Union (3/4")
Series
Meter Nut
Horizontal
Outlet Connections
Q = Angle Lockwing Ball
Example 755-207QND2 33
Tandem
Valve Rated at 300 PSIG2 = -22 CTS MacPak Compression Integral
Tandem setters are supplied with
Setter
(3/4", 1", or 1 1/4")
adapters and “S” tube. Please specify
NOTE: Unless specified all tandem 3 = -33 PEP MacPak Compression Integral (3/4" or 1")
device length and threads when ordering
components have meter nuts 4 = -44 PVC MacPak Compression Integral (3/4" or 1")
without saddles.
5 = -55 IP MacPak Compression Integral (3/4" or 1")
OPTIONS
-Assemblies shipped with two 1/8" EPDM rubber meter gaskets and two union nut gaskets.
-Insert stiffeners are required on all flexible plastic connections.
-Not all combinations available, contact factory with your requirements.
-Most Meter Setters are Made to order and are not returnable.
-Please verify with the factory that the model number you have configured is available and meets your requirements.
14
800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com
11-12
Copper Meter Setters
725 SERIES
1" METERS
Horizontal Style, Double Purpose Union Inlet x Integral CTS, PEP or IP Compression -22, -33, -44, -55 Outlet
Setters normally supplied with Double Purpose End Connections. See Page 56 to order end connections separately.
To order 725 Series Model No. 725-410WXD2
725
-
4
10
44
above means:
INLET OUTLET
INLET OUTLET
WX
D2
44
Series
Style
Meter Size
Meter Height
Inlet and Outlet Valves Type of connection Blank Space Size Inlet & Outlet
Inlet and Outlet
Series 725
– = Standard
725
10 = 10"
4 = 1"
4 = 1"
Standard
C= Full Port Angle Single 12 = 12"
5 = 11⁄4"
Check Valve
15 = 15"
Inlet Connections
18 = 18"
D= Angle Dual Check Valve D = Double Purpose Union (Flare or FNPT) (1")
(ASSE 1024) 21 = 21"
M= MNPT Union (1" or 1 1/4")
12 minimum height
24 = 24"
S = Solder Union (1")
27 = 27"
J = Full Port Angle Lockwing Ball
Valve
300
PSIG
Additional
18" & Taller includes
Outlet Connections
heights available, M= Full Port Angle Dual
Brace Support Bar
contact factory
2 = -22 CTS MacPak Compression Integral (1", 1 1/4")
Valve (ASSE 1024)
3 = -33 PEP MacPak Compression Integral (1")
W= Angle Lockwing Ball Valve rated at 300 PSIG
4 = -44 PVC MacPak Compression Integral (1")
X = Flanged Tubing with 5 = -55 IP MacPak Compression Integral (1")
Meter Nut
For other special meter
connections, contact factory.
For Tandem Series
755
Series
Horizontal
Tandem
Setter
Example 755-412QND2 44
Tandem setters are supplied with
adapters and “S” tube. Please specify
device length and threads when ordering
12" minimum height
Series 755 - Tandem
A = Full Port Angle Single C
heck Valve
F = Angle Dual Check Valve (ASSE 1024)
K= Full Port Angle Lockwing Ball Valve 300 PSIG
N = Flanged Tubing with M
eter Nut
P = Full Port Angle Dual
Valve (ASSE 1024)
Q = Angle Lockwing Ball Valve Rated at 300 PSIG
NOTE: Unless specified all tandem
components have meter nuts without saddles.
OPTIONS
-Assemblies shipped with two 1/8" EPDM rubber meter gaskets and two union nut gaskets.
-Insert stiffeners are required on all flexible plastic connections.
-Not all combinations available, contact factory with your requirements.
-Most Meter Setters are Made to order and are not returnable.
-Please verify with the factory that the model number you have configured is available and meets your requirements.
11-12
800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com
15
Copper Meter Setters
726 SERIES
FOR 5/8", 5/8" x 3/4", or 3/4" METERS
Horizontal Style, Integral -22 CTS, -33 PEP, -44 PVC or -55 IP Compression Inlet x Double Purpose Union Outlet
Setters normally supplied with Double Purpose End Connections. See Page 56 to order end connections separately.
To order 726 Series Model No. 726-207WX2D
INLET OUTLET
726
-
2
07
WX
33
above means:
INLET OUTLET
2D
33
Series
Style
Meter Size
Meter Height
Inlet and Outlet Valves Type of connection Blank Space Size Inlet & Outlet
Inlet and Outlet
Series 726
– = Standard
726
1 = 5/8"
07 = 7"
1 = 1/2"
Standard
C= Full Port Angle Single 2 = 5/8" x 3/4" 09 = 9"
3 = 3/4"
Check Valve
3 = 3/4"
12 = 12"
4 = 1"
Inlet Connections
D= Full Port Angle Dual 15 = 15"
2
=
22
CTS
MacPak
Compression
Integral
Check Valve (ASSE 1024)
18 = 18"
(3/4", 1", or 1 1/4")
W= Angle Lockwing Ball 21 = 21"
3 = -33 PEP MacPak Compression Integral (3/4", or 1")
Valve
rated
at
300
PSIG
24 = 24"
4 = -44 PVC MacPak Compression Integral (3/4", or 1")
X
=
Flanged
Tubing
with
27 = 27"
18" & Taller includes
5 = -55 IP MacPak Compression Integral (3/4", or 1")
Meter
Nut
Additional
Brace Support Bar
heights available, For other special meter contact factory connections, contact factory.
Outlet Connections
C = Copper Flare Union (3/4" or 1")
D = Double Purpose Union (Flare or FNPT) (3/4")
Series 756 - Tandem
For Tandem Series
F = FNPT Union (1/2" or 1")
A = Full Port Angle Single G = G CTS McGrip Compression Union (3/4")
Check Valve
J = C903 Compression Union (3/4")
F = Full Port Angle Dual M= MNPT Union (3/4", 1", or 1 1/4")
Check Valve (ASSE 1024)
N = Flanged Tubing with Q = Q CTS McQuick Compression Union (3/4")
S = Solder Union (3/4" or 1")
Meter Nut
756
T = T CTS Compression Union (3/4" or 1")
Series
Q = Angle Lockwing Ball
Horizontal
Valve Rated at 300 PSIG Z = -3Q PEP McQuick Compression Union (3/4")
Tandem
2 = -22 CTS MacPak Compression Union (3/4" or 1")
Example 756-207QN2D 33
Setter
Tandem setters are supplied with
NOTE: Unless specified all tandem 3 = -33 PEP MacPak Compression Union (3/4")
adapters and “S” tube. Please specify
components have meter nuts 4 = -44 PVC MacPak Compression Union (3/4")
device length and threads when ordering.
without saddles.
5 = -55 IP MacPak Compression Union (3/4")
OPTIONS
-Assemblies shipped with two 1/8" EPDM rubber meter gaskets and two union nut gaskets.
-Insert stiffeners are required on all flexible plastic connections.
-Not all combinations available, contact factory with your requirements.
-Most Meter Setters are Made to order and are not returnable.
-Please verify with the factory that the model number you have configured is available and meets your requirements.
16
800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com
11-12
Copper Meter Setters
726 SERIES
1" METERS
Horizontal Style, Integral -22 CTS, -33 PEP, -44 PVC or -55 IP Compression Inlet x Double Purpose Union Outlet
Setters normally supplied with Double Purpose End Connections. See Page 56 to order end connections separately.
To order 726 Series Model No. 726-410WX2D
726
-
4
10
44
above means:
INLET OUTLET
INLET OUTLET
WX
2D
44
Series
Style
Meter Size
Meter Height
Inlet and Outlet Valves Type of connection Blank Space Size Inlet & Outlet
Inlet and Outlet
Series 726
726
4 = 1"
– = Standard
10 = 10"
4 = 1"
Standard
C= Full Port Angle Single 5 = 1 1/4"
12 = 12"
Check Valve
15 = 15"
Inlet Connections
D= Angle Dual Check Valve 2 = -22 CTS MacPak Compression Integral (1", 1 1/4")
18 = 18"
(ASSE 1024) 21 = 21"
3 = -33 PEP MacPak Compression Integral (1")
12 minimum height
24 = 24"
J = Full Port Angle Lockwing 4 = -44 PVC MacPak Compression Integral (1")
27 = 27"
5 = -55 IP MacPak Compression Integral (1")
Ball Valve 300 PSIG
18" & Taller includes
Additional
Brace Support Bar
heights available, M= Full Port Angle Dual
contact factory
Outlet Connections
Valve (ASSE 1024)
W= Angle Lockwing Ball D = Double Purpose Union (Flare or FNPT) (1")
Valve rated at 300 PSIG
M= MNPT Union (1")
X = Flanged Tubing with S = Solder Union (1")
Meter Nut
For other special meter connections, contact factory.
For Tandem Series
756
Series
Horizontal
Tandem
Setter
Example 756-412QN2D 44
Tandem setters are supplied with
adapters and “S” tube. Please specify
device length and threads when ordering.
12" minimum height
Series 756 - Tandem
A = Full Port Angle Single C
heck Valve
F = Angle Dual Check Valve (ASSE 1024)
K= Full Port Angle Lockwing Ball Valve 300 PSIG
N = Flanged Tubing with M
eter Nut
P = Full Port Angle Dual
Valve (ASSE 1024)
Q = Angle Lockwing Ball
Valve Rated at 300 PSIG
NOTE: Unless specified all tandem components have meter nuts without saddles.
OPTIONS
-Assemblies shipped with two 1/8" EPDM rubber meter gaskets and two union nut gaskets.
-Insert stiffeners are required on all flexible plastic connections.
-Not all combinations available, contact factory with your requirements.
-Most Meter Setters are Made to order and are not returnable.
-Please verify with the factory that the model number you have configured is available and meets your requirements.
11-12
800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com
17
Copper Meter Setters
727 SERIES
FOR 5/8", 5/8" x 3/4", or 3/4" METERS | Horizontal Style, Special "K" Thread x Special "K" Thread
"Cut-In" Style Meter Setting: This setting is a quick and easy installation that involves cutting out a section of service line that is
approximately 1/2" longer than the brass bottom bar of the setter, cleaning approximately 3" of service line on both sides of the setter,
then slipping on the compression assemblies (sold separately) on to the service line. The setter is then inserted into the spacing, the
compression assemblies are tightened to the setter, and the compression nuts are tightened per instructions.
To order 727 Series Model No. 727-207WX above means:
INLET OUTLET
727
-
2
07
Series
Style
Meter Size
Meter Height
Inlet and Outlet Valves
1 = 5/8"
2 = 5/8"x 3/4"
3 = 3/4"
07 = 7"
09 = 9"
12 = 12"
15 = 15"
18 = 18"
21 = 21"
24 = 24"
27 = 27"
Additional
heights available,
contact factory
Series 727
C = Full Port Angle Single Check Valve
D= Full Port Angle Dual Check Valve (ASSE 1024)
W= Angle Lockwing Ball Valve rated at 300 PSIG
X = Flanged Tubing with Meter Nut
For other special meter connections, contact factory.
727
Standard
– = Standard
18" & Taller includes
Brace Support Bar
For Tandem Series
757
Series
Horizontal
Tandem
Setter
Example 757-207QN
Tandem setters are supplied with
adapters and “S” tube. Please specify
device length and threads when ordering.
WX
Series 757 - Tandem
A = Full Port Angle Single Check Valve
F = Full Port Angle Dual Check Valve (ASSE 1024)
N = Flanged Tubing with Meter Nut
Q = Angle Lockwing Ball
Valve Rated at 300 PSIG
NOTE:Unless specified all tandem components have meter nuts without saddles.
OPTIONS
-Assemblies shipped with two 1/8" EPDM rubber meter gaskets.
-Insert stiffeners are required on all flexible plastic connections.
-Not all combinations available, contact factory with your requirements.
-Most Meter Setters are Made to order and are not returnable.
-Please verify with the factory that the model number you have configured is available and meets your requirements.
18
800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com
11-12
Copper Meter Setters
727 SERIES
Valves for Model 727-1, 727-2 or 727-3
"K" Style Inlets & Outlets
Compression Assemblies & Ball Valves
MODEL
VALVE SIZE
DESCRIPTION
761001S
3/4" x 5/8" x 3/4" “K” Swivel Nut x “K” Male Thread
761001SD
3/4" x 5/8" x 3/4" “K” Swivel Nut x “K” Male Thread with test port/drain
761001SW
3/4" x 5/8" x 3/4" “K” Swivel Nut x “K” Male Thread with lockwing
41S O-ring available-25 per bag (sold in bags only)
41SKBV O-ring available-25 per bag (sold in bags only)
761011W
3/4" x 5/8" x 3/4" FNPT x “K” Thread
761011W
3/4"
FNPT x “K” Thread
761021W
3/4" x 5/8" x 3/4" Flare x “K” Thread
761021W
3/4"
Flare x “K” Thread
761021W
1" x 3/4" x 3/4" Flare x “K” Thread
761021WT
3/4" x 5/8" x 3/4" T CTS compression x “K” Thread
761021WT
3/4"
T CTS compression x “K” Thread
761021WT
1" x 3/4" x 3/4" T CTS compression x “K” Thread
761021W-22 3/4" x 5/8" x 3/4" -22 CTS compression x “K” Thread
761021W-22
3/4"
-22 CTS compression x “K” Thread
761021W-22 1" x 3/4" x 3/4" -22 CTS compression x “K” Thread
761021W-33
3/4"
-33 PEP compression x “K” Thread
761021W-44
3/4"
-44 PVC compression x “K” Thread
761021W-55
3/4"
-55 IP compression x “K” Thread
747541T
761021W
761011W
41S
o-ring
761021WT
761001S
41S
o-ring
761021W-22
761021W-33
761021W-44
747541-55
747541-22, 747541-33
747541-44
Fittings for Model 727-1, 727-2, or 727-3
MODEL
747541P 747541S 747541S 747541-22
747541-22
747541-22
747541-22
747541-22
747541Q 747541T 747541T SIZEDESCRIPTION
3/4"
1/2" x 3/4"
3/4"
3/4"
1/2" x 3/4"
1" x 3/4"
1 1/4" x 3/4"
1 3/16" x 3/4"
3/4"
3/4"
1" x 3/4"
MNPT x “K” Thread
Solder x “K” Thread
Solder x “K” Thread
-22 CTS compression x “K” Thread
-22 CTS compressionx “K” Thread
-22 CTS compression x “K” Thread
-22 CTS compression x “K” Thread
-22 CTS compression x “K” Thread
Q CTS compression x “K” Thread
T CTScompression x “K” Thread
T CTS compression x “K” Thread
MODEL
747541T
747541-33
747541-33
747541-3Q
747541-44
747541-44
747541-44
747541-55
747541-55
47541GSKT SIZEDESCRIPTION
11⁄4" x 3/4"
3/4"
1" x 3/4"
1" x 3/4"
1/2" x 3/4"
3/4"
1" x 3/4"
3/4"
1" x 3/4"
–
T CTS compression x “K” Thread
-33 PEP compression x “K” Thread
-33 PEP compression x “K” Thread
-3Q PEP compression x “K” Thread
-44 PVC compression x “K” Thread
-44 PVC compression x “K” Thread
-44 PVCcompression x “K” Thread
-55 IP compression x “K” Thread
-55 IP compression x “K” Thread
Copper spacing gasket
OPTIONS
-Insert stiffeners are required on all flexible plastic connections.
11-12
800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com
19
Copper Meter Setters
728 SERIES
FOR 5/8", 5/8" x 3/4", or 3/4" METERS | Horizontal Style, Integral MNPT x Integral MNPT
To order 728 Series Model No. 728-207WXPP
728
-
2
07
33
above means:
INLET OUTLET
INLET OUTLET
WX
PP
33
Series
Style
Meter Size
Meter Height
Inlet and Outlet Valves Type of connection Blank Space Size Inlet & Outlet
Inlet and Outlet
Series 728
– = Standard
728
07 = 7"
1 = 5/8"
3 = 3/4"
Standard
C= Full Port Angle Single 2 = 5/8" x 3/4" 09 = 9"
4 = 1"
Check Valve
12 = 12"
3 = 3/4"
P = MNPT Integral (3/4", 1")
D= Full Port Angle Dual 15 = 15"
Check Valve (ASSE 1024)
18 = 18"
W= Angle Lockwing Ball 21 = 21"
Valve rated at 300 PSIG
24 = 24"
X = Flanged Tubing with 27
=
27"
18" & Taller includes
Meter Nut
Additional
Brace Support Bar
heights available, For other special meter contact factory
connections, contact factory.
For Tandem Series
758
Series
Horizontal
Tandem
Setter
Example 758-207QNPP 33
Tandem setters are supplied with
adapters and “S” tube. Please specify
device length and threads when ordering.
Series 758 - Tandem
A = Full Port Angle Single Check Valve
F = Full Port Angle Dual Check Valve (ASSE 1024)
N = Flanged Tubing with Meter Nut
Q = Angle Lockwing Ball
Valve Rated at 300 PSIG
NOTE: Unless specified all tandem components have meter nuts without saddles.
OPTIONS
-Assemblies shipped with two 1/8" EPDM rubber meter gaskets.
-Insert stiffeners are required on all flexible plastic connections.
-Not all combinations available, contact factory with your requirements.
-Most Meter Setters are Made to order and are not returnable.
-Please verify with the factory that the model number you have configured is available and meets your requirements.
20
800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com
11-12
Copper Meter Setters
728 SERIES
1" METERS | Horizontal Style, Integral MNPT x Integral MNPT
To order 728 Series Model No. 728-410WXPP
728
-
4
10
44
above means:
INLET OUTLET
INLET OUTLET
WX
PP
Series
Style
Meter Size
Meter Height
Inlet and Outlet Valves Type of connection Blank Space
Inlet and Outlet
Series 728
728
– = Standard
10 = 10"
4 = 1"
Standard
C= Full Port Angle Single 12 = 12"
Check Valve
15 = 15"
P = MNPT Integral
D= Angle Dual Check Valve 18 = 18"
(1", 1 1/4" or 1 1/2")
(ASSE 1024) 21 = 21"
12
minimum
height
24 = 24"
J = Full Port Angle Lockwing 27 = 27"
Ball Valve 300 PSIG
18" & Taller includes
Additional
Brace Support Bar
heights available, M= Full Port Angle Dual Valve (ASSE 1024)
contact factory
W= Angle Lockwing Ball Valve rated at 300 PSIG
X = Flanged Tubing with Meter Nut
For other special meter c onnections,
contact factory.
For Tandem Series
758
Series
Horizontal
Tandem
Setter
Example 758-412QNPP 44
Tandem setters are supplied with
adapters and “S” tube. Please specify
device length and threads when ordering.
12" minimum height
44
Size Inlet & Outlet
4 = 1"
5 = 1 1/4"
6 = 1 1/2
Series 758 - Tandem
A = Full Port Angle Single C
heck Valve
F = Angle Dual Check Valve (ASSE 1024)
K= Full Port Angle Lockwing Ball Valve 300 PSIG
N = Flanged Tubing with Meter Nut
P = Full Port Angle Dual Valve (ASSE 1024)
Q = Angle Lockwing Ball Valve Rated at 300 PSIG
NOTE: Unless specified all tandem components have meter nuts without saddles.
OPTIONS
-Assemblies shipped with two 1/8" EPDM rubber meter gaskets.
-Insert stiffeners are required on all flexible plastic connections.
-Not all combinations available, contact factory with your requirements.
-Most Meter Setters are Made to order and are not returnable.
-Please verify with the factory that the model number you have configured is available and meets your requirements.
11-12
800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com
21
Copper Meter Setters
729 SERIES
FOR 5/8", 5/8" x 3/4", or 3/4" METERS | Horizontal Style, Integral Flare x Integral Flare
To order 729 Series Model No. 729-207WXCC
729
-
2
07
33
above means:
INLET OUTLET
INLET OUTLET
WX
CC
33
Series
Style
Meter Size
Meter Height
Inlet and Outlet Valves Type of connection Blank Space Size Inlet & Outlet
Inlet and Outlet
Series 729
729
– = Standard
07 = 7"
3 = 3/4"
1 = 5/8"
Standard
C= Full Port Angle Single 2 = 5/8" x 3/4" 09 = 9"
Check Valve
12 = 12"
3 = 3/4"
C = Copper Flare Integral (3/4")
15 = 15"
D= Full Port Angle Dual 18 = 18"
Check Valve (ASSE 1024)
21 = 21"
W= Angle Lockwing Ball 24 = 24"
Valve rated at 300 PSIG
27 = 27"
X = Flanged Tubing with 18" & Taller includes
Additional
Meter Nut
Brace Support Bar
heights available,
For other special meter c onnections,
contact factory
contact factory.
For Tandem Series
759
Series
Horizontal
Tandem
Setter
Example 759-207QNCC 33
Tandem setters are supplied with
adapters and “S” tube. Please specify
device length and threads when ordering.
Series 759 - Tandem
A = Full Port Angle Single C
heck Valve
F = Full Port Angle Dual C
heck Valve (ASSE 1024)
N = Flanged Tubing with M
eter Nut
Q = Angle Lockwing Ball V alve Rated at 300 PSIG
NOTE: Unless specified all tandem components have meter nuts without saddles.
OPTIONS
-Assemblies shipped with two 1/8" EPDM rubber meter gaskets.
-Insert stiffeners are required on all flexible plastic connections.
-Not all combinations available, contact factory with your requirements.
-Most Meter Setters are Made to order and are not returnable.
-Please verify with the factory that the model number you have configured is available and meets your requirements.
22
800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com
11-12
Copper Meter Setters
729 SERIES - 1" Meter
1" METERS | Horizontal Style, Integral Flare x Integral Flare
To order 729 Series Model No. 729-410WXCC
729
-
4
10
44
above means:
INLET OUTLET
INLET OUTLET
WX
CC
44
Series
Style
Meter Size
Meter Height
Inlet and Outlet Valves Type of connection Blank Space Size Inlet & Outlet
Inlet and Outlet
Series 729
– = Standard
729
10 = 10"
4 = 1"
4 = 1"
Standard
C= Full Port Angle Single 12 = 12"
Check Valve
15 = 15"
C = Copper Flare Integral (1")
D= Angle Dual Check Valve 18 = 18"
(ASSE 1024) 21 = 21"
12 minimum height
24 = 24"
J = Full Port Angle Lockwing 27 = 27"
18" & Taller includes
Ball Valve 300 PSIG
Additional
Brace Support Bar
heights available, M= Full Port Angle Dual Valve (ASSE 1024)
contact factory
W= Angle Lockwing Ball Valve rated at 300 PSIG
X = Flanged Tubing with M
eter Nut
For other special meter connections, contact factory.
For Tandem Series
759
Series
Horizontal
Tandem
Setter
Example 759-412QNCC 44
Tandem setters are supplied with
adapters and “S” tube. Please specify
device length and threads when ordering.
12" minimum height
Series 759 - Tandem
A = Full Port Angle Single C
heck Valve
F = Angle Dual Check Valve (ASSE 1024)
K= Full Port Angle Lockwing Ball Valve 300 PSIG
N = Flanged Tubing with M
eter Nut
P = Full Port Angle Dual Valve (ASSE 1024)
Q = Angle Lockwing Ball V alve Rated at 300 PSIG
NOTE: Unless specified all tandem components have meter nuts without saddles.
OPTIONS
-Assemblies shipped with two 1/8" EPDM rubber meter gaskets.
-Insert stiffeners are required on all flexible plastic connections.
-Not all combinations available, contact factory with your requirements.
-Most Meter Setters are Made to order and are not returnable.
-Please verify with the factory that the model number you have configured is available and meets your requirements.
11-12
800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com
23
Copper Meter Setters
730 SERIES
FOR 5/8", 5/8" x 3/4", or 3/4" METERS | Vertical Style, Double Purpose Union Inlet x Double Purpose Union Outlet
Setters normally supplied with Double Purpose End Connections. See Page 56 to order end connections separately.
To order 730 Series Model No. 730-2--WXDD
730
-
2
--
33
above means:
INLET OUTLET
INLET OUTLET
WX
DD
33
Series
Style
Meter Size
Meter Height
Inlet and Outlet Valves Type of connection Blank Space Size Inlet & Outlet
Inlet and Outlet
Series 730
1 = 1/2"
– = Standard
730
-- = 7"
1 = 5/8"
3 = 3/4"
Standard
C= Full Port Angle Single 2 = 5/8" x 3/4" 09= 9"
Check Valve
12= 12"
3 = 3/4"
D= Full Port Angle Dual C = Copper Flare Union (3/4" or 1")
15= 15"
Check Valve (ASSE 1024)
D = Double Purpose Union (Flare or FNPT) (3/4")
18= 18"
W= Angle Lockwing Ball F = FNPT Union (1/2" or 1")
21= 21"
Valve rated at 300 PSIG
24= 24"
G = G CTS McGrip Compression Union (3/4")
X = Flanged Tubing with J = C903 Compression Union (3/4")
27= 27"
Meter Nut
Additional
18" & Taller includes
M= MNPT Union (3/4",1", or 1 1/4")
heights available, For other special meter Brace Support Bar
Q = Q CTS McQuick Compression Union (3/4")
contact factory
connections, contact factory.
S = Solder Union (3/4" or 1")
T = T CTS Compression Union (3/4" or 1")
For Tandem Series
Z = -3Q PEP McQuick Compression Union (3/4")
Series 750R - Tandem
A = Full Port Angle Single 2 = -22 CTS MacPak Compression Union (3/4" or 1")
Check Valve
3 = -33 PEP MacPak Compression Union (3/4")
F = Full Port Angle Dual 4 = -44 PVC MacPak Compression Union (3/4")
Check Valve (ASSE 1024)
5 = -55 IP MacPak Compression Union (3/4")
N = Flanged Tubing with 750R
Meter Nut
Series
Vertical
Q = Angle Lockwing Ball
Tandem
Valve Rated at 300 PSIG
Example 750R2--QNDD 33
Setter
Tandem setters are supplied with
adapters and “S” tube. Please specify
device length and threads when ordering.
NOTE: Unless specified all tandem components have meter nuts without saddles.
OPTIONS
-Assemblies shipped with two 1/8" EPDM rubber meter gaskets and two union nut gaskets.
-Insert stiffeners are required on all flexible plastic connections.
-Not all combinations available, contact factory with your requirements.
-Most Meter Setters are Made to order and are not returnable.
-Please verify with the factory that the model number you have configured is available and meets your requirements.
24
800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com
11-12
Copper Meter Setters
730 SERIES - 1" Meter
1" METERS | Vertical Style, Double Purpose Union Inlet x Double Purpose Union Outlet
Setters normally supplied with Double Purpose End Connections. See Page 56 to order end connections separately.
To order 730 Series Model No. 730-4--WXDD
730
-
4
--
44
above means:
INLET OUTLET
INLET OUTLET
WX
DD
44
Series
Style
Meter Size
Meter Height
Inlet and Outlet Valves Type of connection Blank Space Size Inlet & Outlet
Inlet and Outlet
Series 730
4 = 1"
730
– = Standard
-- = 10"
4 = 1"
Standard
C= Full Port Angle Single 12= 12"
Check Valve
15= 15"
D = Double Purpose Union (Flare or FNPT) (1")
D= Angle Dual Check Valve 18= 18"
M= MNPT Union (1" or 1 1/4")
(ASSE 1024)
21= 21"
S = Solder Union (1")
12 minimum height
24= 24"
27= 27"
J = Full Port Angle Lockwing Ball Valve 300 PSIG
Additional
18" & Taller includes
heights available, M= Full Port Angle Dual
Brace Support Bar
contact factory
Valve (ASSE 1024)
W= Angle Lockwing Ball Valve rated at 300 PSIG
X = Flanged Tubing with M
eter Nut
For other special meter connections,
contact factory.
For Tandem Series
750R
Series
Vertical
Tandem
Setter
Example 750R412QNDD 44
Tandem setters are supplied with
adapters and “S” tube. Please specify
device length and threads when ordering.
12" minimum height
Series 750R - Tandem
A = Full Port Angle Single C
heck Valve
F = Angle Dual Check Valve (ASSE 1024)
K= Full Port Angle Lockwing Ball Valve 300 PSIG
N = Flanged Tubing with M
eter Nut
P = Full Port Angle Dual Valve (ASSE 1024)
Q = Angle Lockwing Ball Valve Rated at 300 PSIG
NOTE: Unless specified all tandem components have meter nuts without saddles.
OPTIONS
-Assemblies shipped with two 1/8" EPDM rubber meter gaskets and two union nut gaskets.
-Insert stiffeners are required on all flexible plastic connections.
-Not all combinations available, contact factory with your requirements.
-Most Meter Setters are Made to order and are not returnable.
-Please verify with the factory that the model number you have configured is available and meets your requirements.
11-12
800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com
25
Copper Meter Setters
731 SERIES
FOR 5/8", 5/8" x 3/4", or 3/4" METERS | Vertical Style, Integral CTS, PEP or C903 Compression Inlet & Outlet
Compression Connections - B, G, H, J, Q, T, Y, Z Inlet/Outlet
To order 731 Series Model No. 731-2--WXTT
731
-
2
--
33
above means:
INLET OUTLET
INLET OUTLET
WX
TT
33
Series
Style
Meter Size
Meter Height
Inlet and Outlet Valves Type of connection Blank Space Size Inlet & Outlet
Inlet and Outlet
3 = 3/4"
Series 731
731
– = Standard
-- = 7"
1 = 5/8"
4 = 1"
Standard
C= Full Port Angle Single 2 = 5/8" x 3/4" 09= 9"
Check Valve
12= 12"
3 = 3/4"
B = -3G PEP McGrip Compression Integral (3/4")
15= 15"
D= Full Port Angle Dual G = G CTS McGrip Compression Integral (3/4" or 1")
18= 18"
Check Valve (ASSE 1024)
H = H CTS PE Handyloc Compression Integral (3/4" or 1")
21= 21"
W= Angle Lockwing Ball J = C903 Compression Integral (3/4" or 1")
24= 24"
Valve rated at 300 PSIG
Q = Q CTS McQuick Compression Integral (3/4" or 1")
27= 27"
X = Flanged Tubing with T = T CTS Compression Integral (3/4" or 1")
Additional
18" & Taller includes
Y = -3H PEP Handyloc Compression Integral (3/4" or 1")
heights available, Meter Nut
Brace Support Bar
For other special meter Z = -3Q PEP McQuick Compression Integral (3/4")
contact factory
connections, contact factory.
For Tandem Series
751R
Series
Vertical
Tandem
Setter
Example 751R207QNTT 33
Tandem setters are supplied with
adapters and “S” tube. Please specify
device length and threads when ordering.
Series 751R - Tandem
A = Full Port Angle Single C
heck Valve
F = Full Port Angle Dual Check Valve (ASSE 1024)
N = Flanged Tubing with M
eter Nut
Q = Angle Lockwing Ball
Valve Rated at 300 PSIG
NOTE: Unless specified all tandem components have meter nuts without saddles.
OPTIONS
-Assemblies shipped with two 1/8" EPDM rubber meter gaskets.
-Insert stiffeners are required on all flexible plastic connections.
-Not all combinations available, contact factory with your requirements.
-Most Meter Setters are Made to order and are not returnable.
-Please verify with the factory that the model number you have configured is available and meets your requirements.
26
800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com
11-12
Copper Meter Setters
731 SERIES
1" METERS | Vertical Style, Integral CTS, PEP or C903 Compression Inlet & Outlet
Compression Connections - B, G, H, J, Q, T Inlet/Outlet
To order 731 Series Model No. 731-4--WXTT
731
-
4
--
44
above means:
INLET OUTLET
INLET OUTLET
WX
TT
4
Series
Style
Meter Size
Meter Height
Inlet and Outlet Valves Type of connection Blank Space Size Inlet & Outlet
Inlet and Outlet
Series 731
4 = 1"
731
– = Standard
-- = 10"
4 = 1"
Standard
12= 12"
C= Full Port Angle Single Check Valve
15= 15"
G = G CTS McGrip Compression Integral (1")
18= 18"
D= Angle Dual Check Valve H = H CTS PE Handyloc Compression Integral (1")
21= 21"
(ASSE 1024)
J = C903 Compression Integral (1")
24= 24"
12 minimum height
Q = Q CTS McQuick Compression Integral (1")
27= 27"
J = Full Port Angle Lockwing T = T CTS Compression Integral (1")
Additional
18" & Taller includes
Ball Valve 300 PSIG
heights
available,
Brace Support Bar
M= Full Port Angle Dual contact factory
Valve (ASSE 1024)
W= Angle Lockwing Ball V alve rated at 300 PSIG
X = Flanged Tubing with M
eter Nut
For other special meter connections,
contact factory.
For Tandem Series
751R
Series
Vertical
Tandem
Setter
Example 751R412QNTT 44
Tandem setters are supplied with
adapters and “S” tube. Please specify
device length and threads when ordering.
12" minimum height
Series 751R - Tandem
A = Full Port Angle Single C
heck Valve
F = Angle Dual Check Valve (ASSE 1024)
K= Full Port Angle Lockwing Ball Valve 300 PSIG
N = Flanged Tubing with M
eter Nut
P = Full Port Angle Dual Valve (ASSE 1024)
Q = Angle Lockwing Ball Valve rated at 300 PSIG
NOTE: Unless specified all tandem components have meter nuts without saddles.
OPTIONS
-Assemblies shipped with two 1/8" EPDM rubber meter gaskets.
-Insert stiffeners are required on all flexible plastic connections.
-Not all combinations available, contact factory with your requirements.
-Most Meter Setters are Made to order and are not returnable.
-Please verify with the factory that the model number you have configured is available and meets your requirements.
11-12
800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com
27
Copper Meter Setters
732 SERIES
FOR 5/8", 5/8" x 3/4", or 3/4" METERS | Vertical Style, Integral -22 CTS, -33 PEP, -44 PVC, or -55 IP
Compression Inlet & Outlet
To order 732 Series Model No. 732-2--WX22
732
-
2
--
33
above means:
INLET OUTLET
INLET OUTLET
WX
22
33
Series
Style
Meter Size
Meter Height
Inlet and Outlet Valves Type of connection Blank Space Size Inlet & Outlet
Inlet and Outlet
Series 732
– = Standard
-- = 7"
3 = 3/4"
1 = 5/8"
732
C= Full Port Angle Single Standard
4 = 1"
2 = 5/8" x 3/4" 09= 9"
Check Valve
12= 12"
3 = 3/4"
D= Full Port Angle Dual 2 = -22 CTS MacPak Compression Integral 15= 15"
(3/4" or 1")
Check Valve (ASSE 1024)
18= 18"
W= Angle Lockwing Ball 3 = -33 PEP MacPak Compression Integral (3/4")
21= 21"
4 = -44 PVC MacPak Compression Integral (3/4")
Valve rated at 300 PSIG
24= 24"
X = Flanged Tubing with 5 = -55 IP MacPak Compression Integral (3/4")
27= 27"
Meter Nut
Additional
18" & Taller includes
heights
available,
For other special meter Brace Support Bar
contact factory
connections, contact factory.
For Tandem Series
752R
Series
Vertical
Tandem
Setter
Example 752R207QN22 33
Tandem setters are supplied with
adapters and “S” tube. Please specify
device length and threads when ordering.
Series 752R - Tandem
A = Full Port Angle Single Check Valve
F = Full Port Angle Dual Check Valve (ASSE 1024)
N = Flanged Tubing with Meter Nut
Q = Angle Lockwing Ball
Valve Rated at 300 PSIG
NOTE: Unless specified all tandem components have meter nuts without saddles.
OPTIONS
-Assemblies shipped with two 1/8" EPDM rubber meter gaskets.
-Insert stiffeners are required on all flexible plastic connections.
-Not all combinations available, contact factory with your requirements.
-Most Meter Setters are Made to order and are not returnable.
-Please verify with the factory that the model number you have configured is available and meets your requirements.
28
800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com
11-12
Copper Meter Setters
732 SERIES
1" METERS | Vertical Style, Integral -22 CTS Compression Inlet & Outlet
To order 732 Series Model No. 732-4--WX22
INLET OUTLET
732
-
4
--
WX
44
above means:
INLET OUTLET
22
44
Series
Style
Meter Size
Meter Height
Inlet and Outlet Valves Type of connection Blank Space Size Inlet & Outlet
Inlet and Outlet
Series 732
– = Standard
-- = 10"
4 = 1"
4 = 1"
732
C= Full Port Angle Single 12= 12"
Standard
Check Valve
15= 15"
2 = -22 CTS MacPak Compression Integral (1")
D= Angle Dual Check Valve 18= 18"
(ASSE
1024)
21= 21"
12 minimum height
24= 24"
J = Full Port Angle Lockwing 27= 27"
Ball Valve 300 PSIG
Additional
18" & Taller includes
heights available, M= Full Port Angle Dual
Brace Support Bar
contact factory
Valve (ASSE 1024)
W= Angle Lockwing Ball Valve rated at 300 PSIG
X = Flanged Tubing with M
eter Nut
For other special meter connections, contact factory.
For Tandem Series
752R
Series
Vertical
Tandem
Setter
Example 752R412QN22 44
Tandem setters are supplied with
adapters and “S” tube. Please specify
device length and threads when ordering.
12" minimum height
Series 752R - Tandem
A = Full Port Angle Single C
heck Valve
F = Angle Dual Check Valve (ASSE 1024)
K= Full Port Angle Lockwing Ball Valve 300 PSIG
N = Flanged Tubing with M
eter Nut
P = Full Port Angle Dual Valve (ASSE 1024)
Q = Angle Lockwing Ball V alve Rated at 300 PSIG
NOTE: Unless specified all tandem components have meter nuts without saddles.
OPTIONS
-Assemblies shipped with two 1/8" EPDM rubber meter gaskets.
-Insert stiffeners are required on all flexible plastic connections.
-Not all combinations available, contact factory with your requirements.
-Most Meter Setters are Made to order and are not returnable.
-Please verify with the factory that the model number you have configured is available and meets your requirements.
11-12
800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com
29
Copper Meter Setters
737 SERIES
FOR 5/8", 5/8" x 3/4", or 3/4" METERS | Vertical Style, Integral Flare x Integral Flare
To order 737 Series Model No. 737-2--WXCC
737
-
2
--
33
above means:
INLET OUTLET
INLET OUTLET
WX
CC
33
Series
Style
Meter Size
Meter Height
Inlet and Outlet Valves Type of connection Blank Space Size Inlet & Outlet
Inlet and Outlet
Series 737
737
– = Standard
-- = 7"
3 = 3/4"
1 = 5/8"
Standard
C= Full Port Angle Single 09= 9"
4 = 1"
2 = 5/8" x 3/4"
Check Valve
12= 12"
3 = 3/4"
D= Full Port Angle Dual C = Copper Flare Integral (3/4" or 1")
15= 15"
Check Valve (ASSE 1024)
18= 18"
W= Angle Lockwing Ball 21= 21"
Valve rated at 300 PSIG
24= 24"
X = Flanged Tubing with 27= 27"
Meter Nut
Additional
18" & Taller includes
heights available, For other special meter
Brace Support Bar
contact factory
connections, contact factory.
For Tandem Series
759R
Series
Vertical
Tandem
Setter
Example 759R207WXCC 33
Tandem setters are supplied with
adapters and “S” tube. Please specify
device length and threads when ordering.
Series 759R - Tandem
A = Full Port Angle Single Check Valve
F = Full Port Angle Dual Check Valve (ASSE 1024)
N = Flanged Tubing with Meter Nut
Q = Angle Lockwing Ball
Valve Rated at 300 PSIG
NOTE: Unless specified all tandem components have meter nuts without saddles.
OPTIONS
-Assemblies shipped with two 1/8" EPDM rubber meter gaskets.
-Insert stiffeners are required on all flexible plastic connections.
-Not all combinations available, contact factory with your requirements.
-Most Meter Setters are Made to order and are not returnable.
-Please verify with the factory that the model number you have configured is available and meets your requirements.
30
800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com
11-12
Copper Meter Setters
737 SERIES
1" METERS | Vertical Style, Integral Flare x Integral Flare
To order 737 Series Model No. 737-4--WXCC
737
-
4
--
44
above means:
INLET OUTLET
INLET OUTLET
WX
CC
Series
Style
Meter Size
Meter Height
Inlet and Outlet Valves Type of connection Blank Space
Inlet and Outlet
Series 737
737
– = Standard
-- = 10"
4 = 1"
Standard
C= Full Port Angle Single 12= 12"
Check Valve
15= 15"
C = Copper Flare Integral (1")
D= Angle Dual Check Valve 18= 18"
(ASSE 1024) 21= 21"
12 minimum height
24= 24"
J = Full Port Angle Lockwing 27= 27"
Ball Valve 300 PSIG
Additional
18" & Taller includes
M= Full Port Angle Dual
heights
available,
Brace Support Bar
contact factory
Valve (ASSE 1024)
W= Angle Lockwing Ball Valve rated at 300 PSIG
X = Flanged Tubing with M
eter Nut
For other special meter connections, contact factory.
For Tandem Series
759R
Series
Vertical
Tandem
Setter
Example 759R412WXCC 44
Tandem setters are supplied with
adapters and “S” tube. Please specify
device length and threads when ordering.
12" minimum height
44
Size Inlet & Outlet
4 = 1"
Series 759R - Tandem
A = Full Port Angle Single C
heck Valve
F = Angle Dual Check Valve (ASSE 1024)
K= Full Port Angle Lockwing Ball Valve 300 PSIG
N = Flanged Tubing with M
eter Nut
P = Full Port Angle Dual
Valve (ASSE 1024)
Q = Angle Lockwing Ball
Valve Rated at 300 PSIG
NOTE: Unless specified all tandem components have meter nuts without saddles.
OPTIONS
-Assemblies shipped with two 1/8" EPDM rubber meter gaskets.
-Insert stiffeners are required on all flexible plastic connections.
-Not all combinations available, contact factory with your requirements.
-Most Meter Setters are Made to order and are not returnable.
-Please verify with the factory that the model number you have configured is available and meets your requirements.
11-12
800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com
31
Copper Meter Setters
738 SERIES
FOR 5/8", 5/8" x 3/4", or 3/4" METERS | Vertical Style, Integral MNPT x Integral MNPT
To order 738 Series Model No. 738-2--WXPP
738
-
2
--
33
above means:
INLET OUTLET
INLET OUTLET
WX
PP
33
Series
Style
Meter Size
Meter Height
Inlet and Outlet Valves Type of connection Blank Space Size Inlet & Outlet
Inlet and Outlet
Series 738
738
– = Standard
-- = 7"
3 = 3/4"
1 = 5/8"
Standard
C= Full Port Angle Single 2 = 5/8" x 3/4" 09= 9"
Check Valve
12= 12"
3 = 3/4"
D= Full Port Angle Dual P = Male Iron Pipe Integral (3/4")
15= 15"
Check Valve (ASSE 1024)
18= 18"
W= Angle Lockwing Ball 21= 21"
Valve rated at 300 PSIG
24= 24"
X = Flanged Tubing with M
eter Nut
27=
27"
18" & Taller includes
Additional
For other special meter Brace Support Bar
heights available, connections, contact factory.
contact factory
For Tandem Series
758R
Series
Vertical
Tandem
Setter
Example 758R207WXPP 33
Tandem setters are supplied with
adapters and “S” tube. Please specify
device length and threads when ordering.
Series 758R - Tandem
A = Full Port Angle Single Check Valve
F = Full Port Angle Dual Check Valve (ASSE 1024)
N = Flanged Tubing with Meter Nut
Q = Angle Lockwing Ball
Valve Rated at 300 PSIG
NOTE: Unless specified all tandem components have meter nuts without saddles.
OPTIONS
-Assemblies shipped with two 1/8" EPDM rubber meter gaskets.
-Insert stiffeners are required on all flexible plastic connections.
-Not all combinations available, contact factory with your requirements.
-Most Meter Setters are Made to order and are not returnable.
-Please verify with the factory that the model number you have configured is available and meets your requirements.
32
800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com
11-12
Copper Meter Setters
738 SERIES
1" METERS | Vertical Style, Integral MNPT x Integral MNPT
To order 738 Series Model No. 738-4--WXPP
738
-
4
--
44
above means:
INLET OUTLET
INLET OUTLET
WX
PP
44
Series
Style
Meter Size
Meter Height
Inlet and Outlet Valves Type of connection Blank Space Size Inlet & Outlet
Inlet and Outlet
Series 738
738
– = Standard
-- = 10"
4 = 1"
4 = 1"
Standard
C= Full Port Angle Single 12= 12"
Check Valve
15= 15"
P = Male Iron Pipe Integral (1")
D= Angle Dual Check Valve 18= 18"
(ASSE 1024)
21= 21"
12 minimum height
24= 24"
27= 27"
J = Full Port Angle Lockwing Ball Valve 300 PSIG
Additional
18" & Taller includes
heights available, M= Full Port Angle Dual
Brace Support Bar
contact factory
Valve (ASSE 1024)
W= Angle Lockwing Ball Valve rated at 300 PSIG
X = Flanged Tubing with M
eter Nut
For other special meter connections, contact factory.
For Tandem Series
758R
Series
Vertical
Tandem
Setter
Example 758R412WXPP 44
Tandem setters are supplied with
adapters and “S” tube. Please specify
device length and threads when ordering.
12" minimum height
Series 759R - Tandem
A = Full Port Angle Single C
heck Valve
F = Angle Dual Check Valve (ASSE 1024)
K= Full Port Angle Lockwing Ball Valve 300 PSIG
N = Flanged Tubing with M
eter Nut
P = Full Port Angle Dual Valve (ASSE 1024)
Q = Angle Lockwing Ball Valve Rated at 300 PSIG
NOTE: Unless specified all tandem components have meter nuts without saddles.
OPTIONS
-Assemblies shipped with two 1/8" EPDM rubber meter gaskets.
-Insert stiffeners are required on all flexible plastic connections.
-Not all combinations available, contact factory with your requirements.
-Most Meter Setters are Made to order and are not returnable.
-Please verify with the factory that the model number you have configured is available and meets your requirements.
11-12
800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com
33
Copper Meter Setters
739 SERIES
FOR 5/8", 5/8" x 3/4", or 3/4" METERS | Vertical / Horizontal Style,
Multiple Combinations
Flare Integral
To order 739 Series Model No. 739-207WXCD
INLET OUTLET
739
-
2
07
WX
33
Double Purpose Outlet*
above means:
INLET OUTLET
CD
33
Series
Style
Meter Size
Meter Height
Inlet and Outlet Valves Type of connection Blank Space Size Inlet & Outlet
Inlet and Outlet
Series 739
1 = 1/2"
– = Standard
-- = 7"
1 = 5/8"
739
C= Full Port Angle Single 3 = 3/4"
Standard
09=
9
"
2 = 5/8" x 3/4"
Check Valve
4 = 1"
12= 12"
3 = 3/4"
D=
Full
Port
Angle
Dual
15= 15"
Check Valve (ASSE 1024)
18= 18"
W= Angle Lockwing Ball Integral Inlet x Double Purpose Outlet*
21= 21"
C = Copper Flare Integral (3/4")
Valve rated at 300 PSIG
24= 24"
T = T CTS Compression Integral (3/4")
X
=
Flanged
Tubing
with
27= 27"
18" & Taller includes
2 = -22 CTS MacPak Compression Integral (3/4")
Meter
Nut
Brace Support Bar
Additional
For
other
special
meter
heights available,
Double Purpose Inlet* x Integral Outlet
connections, contact factory.
contact factory
Q = Q CTS McQuick Compression Integral (3/4")
G = G CTS McGrip Compression Integral (3/4")
H = H CTS PE Handyloc Compression Integral (3/4")
For Tandem Series
T = T CTS Compression Integral (3/4")
Series 759 - Tandem
A = Full Port Angle Single 2 = -22 CTS MacPak Compression Integral (3/4")
Check Valve
F = Full Port Angle Dual Integral Inlet / Outlet
C = Copper Flare Integral (3/4")
Check Valve (ASSE 1024)
759
T = T CTS Compression Integral (3/4")
N = Flanged Tubing with 2 = -22 CTS MacPak Compression Integral (3/4")
Series
Meter Nut
Vertical
Tandem
Q = Angle Lockwing Ball
Example 759-207WXCD 33
Double Purpose Options
Setter
Tandem setters are supplied with
Valve Rated at 300 PSIG C = Copper Flare Union (3/4" or 1")
adapters and “S” tube. Please specify
D = Double Purpose Union (Flare or FNPT) (3/4")
device length and threads when ordering.
NOTE: Unless specified all tandem F = FNPT Union (1/2" or 1")
components have meter nuts G = G CTS McGrip Compression Union (3/4")
without saddles.
J = C903 Compression Union (3/4")
M= MNPT Union (3/4", 1" or 1 1/4")
Q = Q CTS McQuick Compression Union (3/4")
S = Solder Union (3/4" or 1")
T = T CTS Compression Union (3/4", 1" or 1 1/4")
2 = -22 CTS MacPak Compression Union (3/4", 1" or 1 1/4")
3 = -33 PEP MacPak Compression Union (3/4" or 1")
4 = -44 PVC MacPak Compression Union (3/4" or 1")
5 = -55 IP MacPak Compression Union (3/4" or 1")
OPTIONS
-Assemblies shipped with two 1/8" EPDM rubber meter gaskets and two union nut gaskets.
-Insert stiffeners are required on all flexible plastic connections.
-Not all combinations available, contact factory with your requirements.
-Most Meter Setters are Made to order and are not returnable.
-Please verify with the factory that the model number you have configured is available and meets your requirements.
*For Double Purpose Inlet / Outlet options - see Double Purpose options.
34
800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com
11-12
Copper Meter Setters
739 SERIES
1" METERS | Vertical / Horizontal Style, Multiple Combinations
Flare Integral
Double Purpose Outlet*
To order 739 Series Model No. 739-410WXCD
739
-
4
10
44
above means:
INLET OUTLET
INLET OUTLET
WX
CD
44
Series
Style
Meter Size
Meter Height
Inlet and Outlet Valves Type of connection Blank Space Size Inlet & Outlet
Inlet and Outlet
Series
739
– = Standard
-- = 10"
4 = 1"
4 = 1"
739
C= Full Port Angle Single 12= 12"
Standard
5 = 1 1/4"
Check Valve
15= 15"
6 = 1 1/2"
D= Angle Dual Check Valve 18= 18"
(ASSE 1024)
21= 21"
12 minimum height
Integral Inlet x Double Purpose Outlet*
24= 24"
C = Copper Flare Integral (1")
J = Full Port Angle Lockwing 27= 27"
Ball Valve 300 PSIG
G = G CTS McGrip Compression Integral (1")
Additional
18" & Taller includes
H = H CTS PE Handyloc Compression Integral (1")
heights available, M= Full Port Angle Dual
Brace Support Bar
contact factory
Q = Q CTS McQuick Compression Integral (1")
Valve (ASSE 1024)
T = T CTS Compression Integral (1")
W= Angle Lockwing Ball 2 = -22 CTS MacPak Compression Integral (1")
Valve rated at 300 PSIG
X = Flanged Tubing with Double Purpose Inlet* x Integral Outlet
Meter Nut
Q = Q CTS McQuick Compression Integral (1")
For other special meter connections,
G = G CTS McGrip Compression Integral (1")
contact factory.
H = H CTS PE Handyloc Compression Integral (1")
T = T CTS Compression Integral (1")
Series 759 - Tandem
For Tandem Series
2 = -22 CTS MacPak Compression Integral (1")
A = Angle Single Check Valve
F = Angle Dual Check Valve Integral Inlet / Outlet
(ASSE 1024)
G = G CTS McGrip Compression Integral K= Full Port Angle Lockwing (1" or 1 1/4" x 1")
Ball Valve 300 PSIG
H = H CTS Handyloc Compression Integral (1" or 1 1/4" x 1")
759
N = Flanged Tubing with M
eter Nut
Series
Q = Q CTS McQuick Compression Integral P = Full Port Angle Dual Valve Vertical
(1" or 1 1/4" x 1")
(ASSE 1024)
Tandem
T = T CTS Compression Integral (1" or 1 1/4" x 1")
Q = Angle Lockwing Ball Valve Example 759-412WXCD 44
Setter
2 = -22 CTS MacPak Compression Integral rated at 300 PSIG
Tandem setters are supplied with
(1" or 1 1/4" x 1")
adapters and “S” tube. Please specify
NOTE: Unless specified all tandem device length and threads when ordering.
components have meter nuts 12" minimum height
Double Purpose Options
without saddles.
D = Double Purpose Union (Flare or FNPT) (1")
M= MNPT Union (1" or 1 1/4")
S = Solder Union (1")
OPTIONS
-Assemblies shipped with two 1/8" EPDM rubber meter gaskets and two union nut gaskets.
-Insert stiffeners are required on all flexible plastic connections.
-Not all combinations available, contact factory with your requirements.
-Most Meter Setters are Made to order and are not returnable.
-Please verify with the factory that the model number you have configured is available and meets your requirements.
*For Double Purpose Inlet / Outlet - see Double Purpose options.
11-12
800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com
35
Copper Meter Setters
760, 761, 762, 763 SERIES
FOR 5/8", 5/8" x 3/4", or 3/4" METERS | Horizontal "F" Style
Model Number Example
760-212WX22 33
Model Number Example
760-212WX22 33X18
Picture I
Picture II
Vertical Brace Eye Hole
Standard
Vertical Brace Eye Hole
Standard
Extended Leg
OPTIONAL
Optional Horizontal Brace Eye Hole
To order 760 Series Model No. 760-212WX22
760
-
2
12
33x18
INLET OUTLET
INLET OUTLET
WX
22
above means:
33
X18
Series
Style
Meter Size
Meter Height
Inlet and Outlet Valves Type of connection
Blank
Size Inlet Extended
Inlet and Outlet
Space
& Outlet
Leg
12 = 12"
760
– = Standard
1 = 5/8"
Series 760/762
Standard
H = Horizontal 2 = 5/8" x 3/4" 15 = 15"
C= Full Port Angle Single 1 = 1/2"
9"
Brace Eye 3 = 3/4"
18 = 18"
Check Valve
3 = 3/4"
12"
762 Series
(3/4" or 1")
21 = 21"
D= Full Port Angle Dual 4 = 1"
15"
Vertical/Horizontal
24 = 24"
Check Valve (ASSE 1024)
18"
27 = 27"
W= Angle Lockwing Ball 24"
Additional
Valve rated at 300 PSIG
heights available, X = Flanged Tubing with 18" & Taller includes
contact factory
B = -3G PEP McGrip Compression Integral (3/4" or 1")
Meter Nut
Brace Support Bar
C = Copper Flare Integral (3/4" or 1")
For other special meter
D = Double Purpose Union (Flare or FNPT) (3/4")
connections, contact factory.
F = FNPT Union (1/2" or 1")
G = G CTS McGrip Compression Integral (3/4" or 1")
Series 761/763 - Tandem
For Tandem Series
H = H CTS PE Handyloc Compression Integral (3/4"or 1")
A = Full Port Angle Single J = C903 Compression Integral (3/4" or 1")
Check
Valve
761
M= MNPT Union (3/4", 1" or 1 1/4")
F = Full Port Angle Dual Series
Check Valve (ASSE 1024)
Horizontal
P = MNPT Integral (3/4" or 1")
Tandem
N = Flanged Tubing with Q = Q CTS McQuick Compression Integral (3/4" or 1")
Setter
Meter Nut
S = Solder Union (3/4" or 1")
Q = Angle Lockwing Ball Valve T = T CTS Compression Integral (3/4" or 1")
763 Series
rated at 300 PSIG
Example 761-207WX
Vertical
Y = -3H PEP Handyloc Compression Integral (3/4"or 1")
Tandem setters are supplied with
NOTE: Unless specified all tandem Horizontal
adapters and “S” tube. Please specify
Z = -3Q PEP McQuick Compression Integral (3/4")
components have meter nuts Tandem
device length and threads when ordering.
2 = -22 CTS MacPak Compression Integral (3/4" or 1")
without saddles.
3 = -33 PEP MacPak Compression Integral (3/4")
4 = -44 PVC MacPak Compression Integral (3/4")
5 = -55 IP MacPak Compression Integral (3/4")
OPTIONS
-Assemblies shipped with two 1/8" EPDM rubber meter gaskets and two union nut gaskets.
-Insert stiffeners are required on all flexible plastic connections.
-Not all combinations available, contact factory with your requirements.
-Most Meter Setters are Made to order and are not returnable.
-Please verify with the factory that the model number you have configured is available and meets your requirements.
36
800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com
11-12
Copper Meter Setters
760, 761, 762,
763 SERIES
1" METERS | Horizontal "F" Style
Model Number Example
760-415WX22 44
Model Number Example
760-415WX22 44X18
Picture I
Picture II
Vertical Brace Eye Hole
Standard
Vertical Brace Eye Hole
Standard
Extended Leg
OPTIONAL
Optional Horizontal Brace Eye Hole
To order 760 Series Model No. 760-415WX22
760
-
4
15
44x18
INLET OUTLET
INLET OUTLET
WX
22
above means:
44
X18
Series
Style
Meter Size
Meter Height
Inlet and Outlet Valves Type of connection
Blank
Size Inlet Extended
Inlet and Outlet
Space
& Outlet
Leg
15 = 15"
760
– = Standard
4 = 1"
Series 760/762
Standard
18 = 18"
4 = 1"
9"
H = Horizontal C= Full Port Angle Single Brace Eye 21 = 21"
12"
Check Valve
762 Series
(3/4" or 1")
24 = 24"
15"
D= Angle Dual Check Valve Vertical/Horizontal
27 = 27"
18"
(ASSE 1024)
15 minimum height
Additional
24"
heights available, J = Full Port Angle Lockwing contact factory
Ball Valve 300 PSIG
18" & Taller includes
B = -3G PEP McGrip Compression Union (1")
M= Full Port Angle Dual
Brace Support Bar
C = Copper Flare Integral (1")
Valve (ASSE 1024)
D = Double Purpose Union (Flare or FNPT) 1")
W= Angle Lockwing Ball G = G CTS McGrip Compression Union (1")
Valve rated at 300 PSIG
H = H CTS PE Handyloc Compression Integral (1")
X = Flanged Tubing with M
eter Nut
J = C903 Compression Integral (1")
For other special meter connections,
M= MNPT Union (1" or 1 1/4)
contact factory.
P = MNPT Integral (1")
Q = Q CTS McQuick Compression Integral (1")
Series 761/763 - Tandem
For Tandem Series
A = Full Port Angle Single C
heck Valve S = Solder Union (1")
T = T CTS Compression Integral (1")
F = Angle Dual Check Valve
761
Y = -3H PEP Handyloc Compression Integral (1")
(ASSE
1024)
Series
Z = -3Q PEP McQuick Compression Integral (1")
Horizontal
K= Full Port Angle Lockwing 2 = -22 CTS MacPak Compression Integral (1")
Tandem
Ball Valve 300 PSIG
Setter
3 = -33 PEP MacPak Compression Integral (1")
N = Flanged Tubing with M
eter Nut
4 = -44 PVC MacPak Compression Integral (1")
P = Full Port Angle Dual Valve (ASSE 1024)
5 = -55 IP MacPak Compression Integral (1")
763
Example 761-415WX
Tandem setters are supplied with
Q = Angle Lockwing Ball Valve Series
adapters and “S” tube. Please specify
rated at 300 PSIG
Vertical
device
length
and
threads
when
ordering.
Horizontal
NOTE: Unless specified all tandem 15" minimum height
Tandem
components have meter nuts without saddles.without saddles.
OPTIONS
-Assemblies shipped with two 1/8" EPDM rubber meter gaskets and two union nut gaskets.
-Insert stiffeners are required on all flexible plastic connections.
-Not all combinations available, contact factory with your requirements.
-Most Meter Setters are Made to order and are not returnable.
-Please verify with the factory that the model number you have configured is available and meets your requirements.
11-12
800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com
37
Copper Meter Setters
764 SERIES
FOR 5/8", 5/8" x 3/4", or 3/4" METERS | Low Rise Horizontal "F" Style
To order 764 Series Model No. 764-204WDPP
764
-
2
04
33
above means:
INLET OUTLET
INLET OUTLET
WD
PP
33
Series
Style
Meter Size
Meter Height
Inlet and Outlet Valves Type of connection
Blank
Size Inlet
Inlet and Outlet
Space
& Outlet
– = Standard
1 = 5/8"
Series 764
04 = 4"
764
2 = 5/8" x 3/4" Additional
C= Full Port Angle Single Standard
1 = 1/2"
heights available, Check Valve
3 = 3/4"
3 = 3/4"
contact factory
D= Full Port Angle Dual 4 = 1"
Check Valve (ASSE 1024)
W= Angle Lockwing Ball Valve rated at 300 PSIG
X = Flanged Tubing with B = -3G PEP McGrip Compression Integral (3/4" or 1")
Meter Nut
C = Copper Flare Integral (3/4" or 1")
For other special meter
connections, contact factory.
D = Double Purpose Union (Flare or FNPT) (3/4")
F = FNPT Union (1/2" or 1")
G = G CTS McGrip Compression Integral (3/4" or 1")
Series 764 - Tandem
For Tandem Series
A = Full Port Angle Single H = H CTS PE Handyloc Compression Integral (3/4"or 1")
J = C903 Compression Integral (3/4" or 1")
Check Valve
F = Full Port Angle Dual M= MNPT Union (3/4",1" or 1 1/4")
Check Valve (ASSE 1024)
P = MNPT Integral (3/4" or 1")
764
N = Flanged Tubing with Q = Q CTS McQuick Compression Integral (3/4" or 1")
Series
Meter Nut
S = Solder Union (3/4" or 1")
Horizontal
Q
=
Angle
Lockwing
Ball
T = T CTS Compression Integral (3/4" or 1")
Tandem
Valve Rated at 300 PSIG
Example 764-207WX
Setter
Y = -3H PEP Handyloc Compression Integral
Tandem setters are supplied with
(3/4"or 1")
adapters and “S” tube. Please specify
NOTE: Unless specified all tandem device length and threads when ordering.
components have meter nuts Z = -3Q PEP McQuick Compression Integral (3/4")
2 = -22 CTS MacPak Compression Integral (3/4" or 1")
without saddles.
3 = -33 PEP MacPak Compression Integral (3/4")
4 = -44 PVC MacPak Compression Integral (3/4")
5 = -55 IP MacPak Compression Integral (3/4")
OPTIONS
-Assemblies shipped with two 1/8" EPDM rubber meter gaskets, and two union nut gaskets.
-Insert stiffeners are required on all flexible plastic connections.
-Not all combinations available, contact factory with your requirements.
-Most Meter Setters are Made to order and are not returnable.
-Please verify with the factory that the model number you have configured is available and meets your requirements.
38
800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com
11-12
Copper Meter Setters
764 SERIES
1" METERS | Low Rise Horizontal "F" Style
To order 764 Series Model No. 764-404WDPP
INLET OUTLET
764
-
4
04
WD
44
above means:
INLET OUTLET
PP
44
Series
Style
Meter Size
Meter Height
Inlet and Outlet Valves Type of connection
Blank
Size Inlet
Inlet and Outlet
Space
& Outlet
4 = 1"
06 = 6"
764
– = Standard
Series 764
Standard
Additional
C= Full Port Angle Single 1 = 1/2"
heights available, Check Valve
3 = 3/4"
contact factory
D= Angle Dual Check Valve
4 = 1"
(ASSE 1024)
J = Full Port Angle Lockwing Ball Valve 300 PSIG
B = -3G PEP McGrip Compression Union (1")
M= Full Port Angle Dual Valve (ASSE 1024)
C = Copper Flare Integral (1")
W= Angle Lockwing Ball D = Double Purpose Union (Flare or FNPT) 1")
Valve rated at 300 PSIG
G = G CTS McGrip Compression Union (1")
X = Flanged Tubing with H = H CTS PE Handyloc Compression Integral (1")
Meter Nut
J = C903 Compression Integral (1")
For other special meter M= MNPT Union (1" or 1 1/4")
connections, contact factory.
P = MNPT Integral (1")
Q = Q CTS McQuick Compression Integral (1")
Series 764 - Tandem
For Tandem Series
S = Solder Union (1")
A = Full Port Angle Single T = T CTS Compression Integral (1")
Check Valve
Y = -3H PEP Handyloc Compression Integral (1")
F = Angle Dual Check Valve
Z = -3Q PEP McQuick Compression Integral (1")
(ASSE 1024)
2 = -22 CTS MacPak Compression Integral (1")
K= Full Port Angle Lockwing 3 = -33 PEP MacPak Compression Integral (1")
Ball Valve 300 PSIG
4 = -44 PVC MacPak Compression Integral (1")
N
=
Flanged
Tubing
with
M
eter
Nut
764
5 = -55 IP MacPak Compression Integral (1")
Series
P = Full Port Angle Dual
Horizontal
Valve (ASSE 1024)
Tandem
Q = Angle Lockwing Ball
Example
764-207WX
Setter
Tandem setters are supplied with
Valve Rated at 300 PSIG
adapters and “S” tube. Please specify
device length and threads when ordering
NOTE: Unless specified all tandem components have meter nuts without saddles.without saddles.
OPTIONS
-Assemblies shipped with two 1/8" EPDM rubber meter gaskets, and two union nut gaskets.
-Insert stiffeners are required on all flexible plastic connections.
-Not all combinations available, contact factory with your requirements.
-Most Meter Setters are Made to order and are not returnable.
-Please verify with the factory that the model number you have configured is available and meets your requirements.
11-12
800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com
39
Copper Meter Setters
770 SERIES
FOR 5/8", 5/8" x 3/4", or 3/4" METERS | Horizontal "L" Style, Multiple Combinations
To order 770 Series Model No. 770-2--GN2D
770
-
2
--
33
above means:
INLET OUTLET
INLET OUTLET
GN
2D
33
Series
Style
Meter Size
Meter Height
Inlet and Outlet Valves Type of connection Blank Space Size Inlet & Outlet
Inlet and Outlet
Series 726
– = Standard
770
-- = Standard
1 = 5/8"
3 = 3/4"
Standard
A = Full Port Angle Single 2 = 5/8" x 3/4"
4 = 1"
Check
Valve
3 = 3/4"
F = Full Port Angle Dual Inlet & Outlet Connections
C = Copper Flare Union (3/4" or 1")
Check Valve (ASSE 1024)
G= Angle Lockwing Plug D = Double Purpose Union (Flare or FNPT) (3/4")
F = FNPT Union (1/2" or 1")
Valve rated at 100 PSIG
N= Flanged Tubing with G = G CTS McGrip Compression Integral (3/4")
H = H CTS PE Handyloc Compression Integral (3/4")
Meter Nut
Q= Angle Lockwing Ball Valve M= MNPT Union (3/4", 1" or 1 1/4")
Q = Q CTS McQuick Compression Integral (3/4")
rated at 300 PSIG
S = Solder Union (3/4" or 1")
T = T CTS Compression Integral (3/4" or 1" union)
NOTE: Unless specified all series
770 components have meter nuts 2 = -22 CTS MacPak Compression Integral (3/4" or 1" union)
3 = -33 PEP MacPak Compression Union (3/4")
without saddles.
4 = -44 PVC MacPak Compression Union (3/4")
5 = -55 IP MacPak Compression Union (3/4")
OPTIONS
-Assemblies shipped with two 1/8" EPDM rubber meter gaskets, and two union nut gaskets.
-Insert stiffeners are required on all flexible plastic connections.
-Not all combinations available, contact factory with your requirements.
-Most Meter Setters are Made to order and are not returnable.
-Please verify with the factory that the model number you have configured is available and meets your requirements.
40
800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com
11-12
Copper Meter Setters
770 SERIES
1" METERS | Horizontal "L" Style, Multiple Combinations
To order 770 Series Model No. 770-4--GN2D
INLET OUTLET
770
-
4
--
GN
44
above means:
INLET OUTLET
2D
44
Series
Style
Meter Size
Meter Height
Inlet and Outlet Valves Type of connection Blank Space Size Inlet & Outlet
Inlet and Outlet
Series 726
770
– = Standard
-- = Standard
4 = 1"
4 = 1"
Standard
A = Full Port Angle Single Check Valve
F = Angle Dual Check Valve Inlet & Outlet Connections
C = Copper Flare Integral (1")
(ASSE 1024)
G= Angle Lockwing Plug D = Double Purpose Union (Flare or FNPT) (1")
G = G CTS McGrip Compression Integral (1")
Valve rated at 100 PSIG
N= Flanged Tubing with H = H CTS PE Handyloc Compression Integral (1")
M= MNPT Union (1" or 1 1/4")
Meter Nut
(1", 1 1/4")
Q= Angle Lockwing Ball Valve Q = Q CTS McQuick Compression Integral
T = T CTS Compression Integral (1", 11⁄4")
rated at 300 PSIG
Y = -3H PEP Handyloc Compression Integral (1")
Z = -3Q PEP McQuick Compression Integral (1")
NOTE: Unless specified all series
770 components have meter nuts 2 = -22 CTS MacPak Compression Integral (1")
without saddles.
OPTIONS
-Assemblies shipped with two 1/8" EPDM rubber meter gaskets, and two union nut gaskets.
-Insert stiffeners are required on all flexible plastic connections.
-Not all combinations available, contact factory with your requirements.
-Most Meter Setters are Made to order and are not returnable.
-Please verify with the factory that the model number you have configured is available and meets your requirements.
11-12
800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com
41
Copper Meter Setters
720 SERIES - No-Rise
1 1/2" & 2" METERS | Horizontal Style, Multiple Options
To order 720 Series: Model No. 720R600WWFP
720
R
6
00
666
INLET OUTLET
INLET OUTLET
WW
FP
above means:
66
Series
Style
Meter Size
Meter Height
Inlet and
Type of connection
Outlet Valves
Inlet and Outlet
R = Offset 720
6 = 1 1/2" 00 = No Rise Standard
Bypass
Series 720
Standard
7 = 2"
Standard
W= Full Port Lockwing Ball Valve rated at 300 PSIG
For other special meter
connections, contact factory.
Blank
Space
6
Size Inlet & Outlet
Bypass
Size
6 = 1 1/2"
7 = 2"
6 = 1 1/2"
7 = 2"
F = FNPT Integral
G = G CTS McGrip Compression Integral
P = MNPT Integral
Q = Q CTS McQuick Compression Integral
T = T CTS Compression Integral
2 = -22 CTS MacPak Compression Integral
OPTIONS
-For dual check in bypass, contact factory.
-Ball valve available with attached brass handle
-Special flange to flange lay lengths available
-Assemblies shipped with two 1/8" EPDM rubber meter gaskets, and meter support brackets (assembly required)
-Not all combinations available, contact factory with your requirements.
-Most Meter Setters are Made to order and are not returnable.
-Please verify with the factory that the model number you have configured is available and meets your requirements.
42
800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com
11-12
Copper Meter Setters
720 SERIES
1 1/2" & 2" METERS | Horizontal Style, FNPT Inlet and Outlet
To order 720 Series: Model No. 720-609WNFF
720
-
6
09
Series
Style
Meter Size
Meter Height
09= 9"
6 = 1 1/2"
– = Standard
720
12= 12"
7 = 2"
Standard
B= Low Bypass
15= 15"
R= High Offset 18= 18"
Bypass
21= 21"
24= 24"
27= 27"
Additional
heights available,
contact factory
For Tandem Series
750
Series
Horizontal
Tandem
Setter
660
above means:
INLET OUTLET
INLET OUTLET
WN
FF
Inlet and
Outlet Valves
Type of connection
Inlet and Outlet
66
Blank
Space
Series 720
D= Full Port Angle Dual Check Valve (ASSE 1024)
N= Flanged Elbow W= Full Port Angle Lockwing F = FNPT Integral
Ball Valve rated at 300 PSIG
Size Inlet & Outlet
6 = 1 1/2"
7 = 2"
0
Bypass
Size
0 = No Bypass
5 = 1 1/4"
6 = 1 1/2"
7 = 2"
For other special meter connections, contact factory.
Example 750-612WNFF 660
Tandem setters are supplied with
adapters and “S” tube. Please specify
device length and threads when ordering.
OPTIONS
-Bypass available with inline or inline accessible dual check
-Angle dual check available with 1", 1 1/2" or 2" tap in cap - with or without plug
-Ball valve available with attached brass handle
-Special flange to flange lay lengths available
-Assemblies shipped with two 1/8" EPDM rubber meter gaskets, and meter support brackets (assembly required)
-Not all combinations available, contact factory with your requirements.
-Most Meter Setters are Made to order and are not returnable.
-Please verify with the factory that the model number you have configured is available and meets your requirements.
11-12
800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com
43
Copper Meter Setters
721 SERIES
1 1/2" & 2" METERS | Horizontal Style, Integral G, Q, & T CTS Compression Inlet and Outlet
To order 721 Series: Model No. 721-609WNTT
721
-
6
09
Series
Style
Meter Size
Meter Height
09= 9"
– = Standard
6 = 1 1/2"
721
12= 12"
B= Low Bypass
7 = 2"
Standard
15= 15"
R= High Offset 18= 18"
Bypass
21= 21"
24= 24"
27= 27"
Additional
heights available,
contact factory
660
above means:
INLET OUTLET
INLET OUTLET
WN
TT
Inlet and
Outlet Valves
Type of connection
Inlet and Outlet
66
Blank
Space
Size Inlet & Outlet
0
Bypass
Size
Series 721
0 = No Bypass
6 = 1 1/2"
D= Full Port Angle Dual 5 = 1 1/4"
7 = 2"
Check Valve (ASSE 1024)
6 = 1 1/2"
N= Flanged Elbow 7 = 2"
W= Full Port Angle Lockwing G = G CTS McGrip Compression Integral
Ball Valve rated at Q = Q CTS McQuick Compression Integral
300 PSIG
T = T CTS Compression Integral
For other special meter connections, contact factory.
For Tandem Series
751
Series
Horizontal
Tandem
Setter
Example 751-612WNTT 660
Tandem setters are supplied with
adapters and “S” tube. Please specify
device length and threads when ordering.
OPTIONS
-Bypass available with inline or inline accessible dual check
-Angle dual check available with 1", 1 1/2" or 2" tap in cap - with or without plug
-Ball valve available with attached brass handle
-Special flange to flange lay lengths available
-Assemblies shipped with two 1/8" EPDM rubber meter gaskets, and meter support brackets (assembly required)
-Not all combinations available, contact factory with your requirements.
-Most Meter Setters are Made to order and are not returnable.
-Please verify with the factory that the model number you have configured is available and meets your requirements.
44
800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com
11-12
Copper Meter Setters
722 SERIES
1 1/2" & 2" METERS | Horizontal Style, Integral -22 CTS Compression Inlet and Outlet
To order 722 Series: Model No. 722-609WN22
INLET OUTLET
722
-
6
09
Series
Style
Meter Size
Meter Height
09= 9"
– = Standard
6 = 1 1/2"
722
12= 12"
B=
L
ow
Bypass
7
=
2"
Standard
15= 15"
R= High Offset 18= 18"
Bypass
21= 21"
24= 24"
27= 27"
Additional
heights available,
contact factory
660
above means:
INLET OUTLET
WN
22
Inlet and
Outlet Valves
Type of connection
Inlet and Outlet
0
Blank
Space
Size Inlet & Outlet
Bypass
Size
Series 722
0 = No Bypass
6 = 1 1/2"
D= Full Port Angle Dual 5 = 1 1/4"
7 = 2"
Check Valve (ASSE 1024)
6 = 1 1/2"
N= Flanged Elbow 7 = 2"
W= Full Port Angle Lockwing 2 = -22 CTS MacPak Compression Integral
Ball Valve rated at 300 PSIG
For other special meter connections, contact factory.
For Tandem Series
752
Series
Horizontal
Tandem
Setter
Example 752-612WN22 660
Tandem setters are supplied with
adapters and “S” tube. Please specify
device length and threads when ordering.
OPTIONS
-Bypass available with inline or inline accessible dual check
-Angle dual check available with 1", 1 1/2" or 2" tap in cap - with or without plug
-Ball valve available with attached brass handle
-Special flange to flange lay lengths available
-Assemblies shipped with two 1/8" EPDM rubber meter gaskets, and meter support brackets (assembly required)
-Not all combinations available, contact factory with your requirements.
-Most Meter Setters are Made to order and are not returnable.
-Please verify with the factory that the model number you have configured is available and meets your requirements.
11-12
800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com
45
Copper Meter Setters
723 SERIES
1 1/2" & 2" METERS | Horizontal Style, FNPT Inlet and Integral G, Q, & T CTS Compression Outlet
To order 723 Series: Model No. 723-609WNFT
723
-
6
09
Series
Style
Meter Size
Meter Height
09= 9"
– = Standard
6 = 1 1/2"
723
12= 12"
B= Low Bypass
7 = 2"
Standard
15= 15"
R= High Offset 18= 18"
Bypass
21= 21"
24= 24"
27= 27"
Additional
heights available,
contact factory
For Tandem Series
753
Series
Horizontal
Tandem
Setter
660
above means:
INLET OUTLET
INLET OUTLET
WN
FT
Inlet and
Outlet Valves
Type of connection
Inlet and Outlet
Series 723
D= Full Port Angle Dual Check Valve (ASSE 1024)
N= Flanged Elbow W= Full Port Angle Lockwing Ball Valve rated at 300 PSIG
For other special meter
connections, contact factory.
66
Blank
Space
Size Inlet & Outlet
6 = 1 1/2"
7 = 2"
0
Bypass
Size
0 = No Bypass
5 = 1 1/4"
6 = 1 1/2"
7 = 2"
Inlet Connections
F = FNPT Integral
Outlet Connections
G = G CTS McGrip Compression Integral
Q = Q CTS McQuick Compression Integral
T = T CTS Compression Integral
Example 753-612WNFT 660
Tandem setters are supplied with
adapters and “S” tube. Please specify
device length and threads when ordering.
OPTIONS
-Bypass available with inline or inline accessible dual check
-Angle dual check available with 1", 1 1/2" or 2" tap in cap - with or without plug
-Ball valve available with attached brass handle
-Special flange to flange lay lengths available
-Assemblies shipped with two 1/8" EPDM rubber meter gaskets, and meter support brackets (assembly required)
-Not all combinations available, contact factory with your requirements.
-Most Meter Setters are Made to order and are not returnable.
-Please verify with the factory that the model number you have configured is available and meets your requirements.
46
800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com
11-12
Copper Meter Setters
724 SERIES
1 1/2" & 2" METERS | Horizontal Style, Integral G, Q, & T CTS Compression Inlet and FNPT Outlet
To order 724 Series: Model No. 724-609WNTF
724
-
6
09
Series
Style
Meter Size
Meter Height
09= 9"
– = Standard
6 = 1 1/2"
724
12= 12"
B= Low Bypass
7 = 2"
Standard
15= 15"
R= High Offset 18= 18"
Bypass
21= 21"
24= 24"
27= 27"
Additional
heights available,
contact factory
For Tandem Series
754
Series
Horizontal
Tandem
Setter
660
above means:
INLET OUTLET
INLET OUTLET
WN
TF
Inlet and
Outlet Valves
Type of connection
Inlet and Outlet
Series 724
D= Full Port Angle Dual Check Valve (ASSE 1024)
N= Flanged Elbow W= Full Port Angle Lockwing Ball Valve rated at 300 PSIG
For other special meter
connections, contact factory.
66
Blank
Space
Size Inlet & Outlet
6 = 1 1/2"
7 = 2"
0
Bypass
Size
0 = No Bypass
5 = 1 1/4"
6 = 1 1/2"
7 = 2"
Inlet Connections
G = G CTS McGrip Compression Integral
Q = Q CTS McQuick Compression Integral
T = T CTS Compression Integral
Outlet Connections
F = FNPT Integral
Example 754-612WNTF 660
Tandem setters are supplied with
adapters and “S” tube. Please specify
device length and threads when ordering.
OPTIONS
-Bypass available with inline or inline accessible dual check
-Angle dual check available with 1", 1 1/2" or 2" tap in cap - with or without plug
-Ball valve available with attached brass handle
-Special flange to flange lay lengths available
-Assemblies shipped with two 1/8" EPDM rubber meter gaskets, and meter support brackets (assembly required)
-Not all combinations available, contact factory with your requirements.
-Most Meter Setters are Made to order and are not returnable.
-Please verify with the factory that the model number you have configured is available and meets your requirements.
11-12
800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com
47
Copper Meter Setters
725 SERIES
1 1/2" & 2" METERS | Horizontal Style, FNPT Inlet and Integral -22 CTS Compression Outlet
To order 725 Series: Model No. 725-609WNF2
INLET OUTLET
725
-
6
09
Series
Style
Meter Size
Meter Height
09= 9"
– = Standard
6 = 1 1/2"
725
12= 12"
B= Low Bypass
7 = 2"
Standard
15= 15"
R= High Offset Bypass
18= 18"
21= 21"
24= 24"
27= 27"
Additional
heights available,
contact factory
For Tandem Series
755
Series
Horizontal
Tandem
Setter
660
above means:
INLET OUTLET
WN
F2
Inlet and
Outlet Valves
Type of connection
Inlet and Outlet
66
Blank
Space
Size Inlet & Outlet
0
Bypass
Size
Series 723
0 = No Bypass
6 = 1 1/2"
5 = 1 1/4"
D= Full Port Angle Dual 7 = 2"
Check Valve (ASSE 1024)
6 = 1 1/2"
7 = 2"
N= Flanged Elbow W= Full Port Angle Lockwing Inlet Connections
Ball Valve rated at F = FNPT Integral
300 PSIG
Outlet Connections
2 = -22 CTS MacPak Compression Integral
For other special meter connections, contact factory.
Example 755-612WNF2 660
Tandem setters are supplied with
adapters and “S” tube. Please specify
device length and threads when ordering.
OPTIONS
-Bypass available with inline or inline accessible dual check
-Angle dual check available with 1", 1 1/2" or 2" tap in cap - with or without plug
-Ball valve available with attached brass handle
-Special flange to flange lay lengths available
-Assemblies shipped with two 1/8" EPDM rubber meter gaskets, and meter support brackets (assembly required)
-Not all combinations available, contact factory with your requirements.
-Most Meter Setters are Made to order and are not returnable.
-Please verify with the factory that the model number you have configured is available and meets your requirements.
48
800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com
11-12
Copper Meter Setters
726 SERIES
1 1/2" & 2" METERS | Horizontal Style, Integral -22 CTS Compression Inlet and FNPT Outlet
To order 726 Series: Model No. 726-609WN2F
INLET OUTLET
726
-
6
09
Series
Style
Meter Size
Meter Height
09= 9"
– = Standard
6 = 1 1/2"
726
12= 12"
B= Low Bypass
7 = 2"
Standard
15= 15"
R= High Offset Bypass
18= 18"
21= 21"
24= 24"
27= 27"
Additional
heights available,
contact factory
For Tandem Series
756
Series
Horizontal
Tandem
Setter
660
above means:
INLET OUTLET
WN
2F
Inlet and
Outlet Valves
Type of connection
Inlet and Outlet
66
Blank
Space
Size Inlet & Outlet
0
Bypass
Size
Series 726
0 = No Bypass
6 = 1 1/2"
D= Full Port Angle Dual 5 = 1 1/4"
7 = 2"
Check Valve (ASSE 1024)
6 = 1 1/2"
7 = 2"
N= Flanged Elbow W= Full Port Angle Lockwing Inlet Connections
Ball Valve rated at 2 = -22 CTS MacPak Compression Integral
300 PSIG
Outlet Connections
F = FNPT Integral
For other special meter connections, contact factory.
Example 756-612WN2F 660
Tandem setters are supplied with
adapters and “S” tube. Please specify
device length and threads when ordering.
OPTIONS
-Bypass available with inline or inline accessible dual check
-Angle dual check available with 1", 1 1/2" or 2" tap in cap - with or without plug
-Ball valve available with attached brass handle
-Special flange to flange lay lengths available
-Assemblies shipped with two 1/8" EPDM rubber meter gaskets, and meter support brackets (assembly required)
-Not all combinations available, contact factory with your requirements.
-Most Meter Setters are Made to order and are not returnable.
-Please verify with the factory that the model number you have configured is available and meets your requirements.
11-12
800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com
49
Copper Meter Setters
730 SERIES
1 1/2" & 2" METERS | Vertical Style, FNPT Inlet and Outlet
To order 730 Series: Model No. 730-608WNFF
730
-
6
08
Series
Style
Meter Size
Meter Height
08= 8"
– = Standard
6 = 1 1/2"
730
12= 12"
B=
L
ow
Bypass
7
=
2"
Standard
15= 15"
R= High Offset Bypass
18= 18"
21= 21"
24= 24"
27= 27"
Additional
heights available,
contact factory
660
above means:
INLET OUTLET
INLET OUTLET
WN
FF
Inlet and
Outlet Valves
Type of connection
Inlet and Outlet
66
Blank
Space
Series 730
D= Full Port Angle Dual Check Valve (ASSE 1024)
N= Flanged Elbow W= Full Port Angle Lockwing F = FNPT Integral
Ball Valve rated at 300 PSIG
Size Inlet & Outlet
6 = 1 1/2"
7 = 2"
0
Bypass
Size
0 = No Bypass
5 = 1 1/4"
6 = 1 1/2"
7 = 2"
For other special meter connections, contact factory.
For Tandem Series
Contact Factory
Tandem setters are supplied with adapters and “S” tube.
Please specify device length and threads when ordering.
OPTIONS
-Bypass available with inline or inline accessible dual check
-Angle dual check available with 1", 1 1/2" or 2" tap in cap - with or without plug
-Ball valve available with attached brass handle
-Special flange to flange lay lengths available
-Assemblies shipped with two 1/8" EPDM rubber meter gaskets, and meter support brackets (assembly required)
-Not all combinations available, contact factory with your requirements.
-Most Meter Setters are Made to order and are not returnable.
-Please verify with the factory that the model number you have configured is available and meets your requirements.
50
800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com
11-12
Copper Meter Setters
731 SERIES
1 1/2" & 2" METERS | Vertical Style, Integral G, Q, & T CTS Compression Inlet and Outlet
To order 731 Series: Model No. 731-608WNTT
731
-
6
08
Series
Style
Meter Size
Meter Height
08= 8"
– = Standard
6 = 1 1/2"
731
12= 12"
B=
L
ow
Bypass
7
=
2"
Standard
15= 15"
R= High Offset Bypass
18= 18"
21= 21"
24= 24"
27= 27"
Additional
heights available,
contact factory
660
above means:
INLET OUTLET
INLET OUTLET
WN
TT
Inlet and
Outlet Valves
Type of connection
Inlet and Outlet
66
Blank
Space
Size Inlet & Outlet
0
Bypass
Size
Series 731
0 = No Bypass
6 = 1 1/2"
5 = 1 1/4"
D= Full Port Angle Dual 7 = 2"
Check Valve (ASSE 1024)
6 = 1 1/2"
7 = 2"
N= Flanged Elbow W= Full Port Angle Lockwing G = G CTS McGrip Compression Integral
Ball Valve rated at Q = Q CTS McQuick Compression Integral
300 PSIG
T = T CTS Compression Integral
For other special meter connections, contact factory.
For Tandem Series
Contact Factory
Tandem setters are supplied with adapters and “S” tube.
Please specify device length and threads when ordering.
OPTIONS
-Bypass available with inline or inline accessible dual check
-Angle dual check available with 1", 1 1/2" or 2" tap in cap - with or without plug
-Ball valve available with attached brass handle
-Special flange to flange lay lengths available
-Assemblies shipped with two 1/8" EPDM rubber meter gaskets, and meter support brackets (assembly required)
-Not all combinations available, contact factory with your requirements.
-Most Meter Setters are Made to order and are not returnable.
-Please verify with the factory that the model number you have configured is available and meets your requirements.
11-12
800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com
51
Copper Meter Setters
732 SERIES
1 1/2" & 2" METERS | Vertical Style, Integral -22 CTS Compression Inlet and Outlet
To order 732 Series: Model No. 732-608WN22
732
-
6
08
Series
Style
Meter Size
Meter Height
08= 8"
– = Standard
6 = 1 1/2"
732
12= 12"
B= Low Bypass
7 = 2"
Standard
15= 15"
R= High Offset Bypass
18= 18"
21= 21"
24= 24"
27= 27"
Additional
heights available,
contact factory
660
above means:
INLET OUTLET
INLET OUTLET
WN
22
Inlet and
Outlet Valves
Type of connection
Inlet and Outlet
66
Blank
Space
Size Inlet & Outlet
0
Bypass
Size
Series 732
0 = No Bypass
6 = 1 1/2"
5 = 1 1/4"
D= Full Port Angle Dual 7 = 2"
Check Valve (ASSE 1024)
6 = 1 1/2"
7 = 2"
N= Flanged Elbow 2
=
22
CTS
MacPak
Compression
Integral
W= Angle Lockwing Ball Valve rated at 300 PSIG
For other special meter connections, contact factory.
For Tandem Series
Contact Factory
Tandem setters are supplied with adapters and “S” tube.
Please specify device length and threads when ordering.
OPTIONS
-Bypass available with inline or inline accessible dual check
-Angle dual check available with 1", 1 1/2" or 2" tap in cap - with or without plug
-Ball valve available with attached brass handle
-Special flange to flange lay lengths available
-Assemblies shipped with two 1/8" EPDM rubber meter gaskets, and meter support brackets (assembly required)
-Not all combinations available, contact factory with your requirements.
-Most Meter Setters are Made to order and are not returnable.
-Please verify with the factory that the model number you have configured is available and meets your requirements.
52
800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com
11-12
Copper Meter Setters
739 SERIES
1 1/2" & 2" METERS | Vertical / Horizontal Style
To order 739 Series: Model No. 739-608WN2F
739
-
6
08
Series
Style
Meter Size
Meter Height
08= 8"
– = Standard
6 = 1 1/2"
739
12= 12"
B= Low Bypass
7 = 2"
Standard
15= 15"
R= High Offset Bypass
18= 18"
21= 21"
24= 24"
27= 27"
Additional
heights available,
contact factory
660
above means:
INLET OUTLET
INLET OUTLET
WN
2F
Inlet and
Outlet Valves
Type of connection
Inlet and Outlet
66
Blank
Space
Size Inlet & Outlet
0
Bypass
Size
Series 739
0 = No Bypass
6 = 1 1/2"
5 = 1 1/4"
D= Full Port Angle Dual 7 = 2"
Check Valve (ASSE 1024)
6 = 1 1/2"
7 = 2"
N= Flanged Elbow F
=
F
NPT
Integral
W= Angle Lockwing Ball G = G CTS McGrip Compression Integral
Valve rated at 300 PSIG
Q = Q CTS McQuick Compression Integral
T = T CTS Compression Integral
For other special meter 2 = -22 CTS MacPak Compression Integral
connections, contact factory.
For Tandem Series
Contact Factory
Tandem setters are supplied with adapters and “S” tube.
Please specify device length and threads when ordering.
OPTIONS
-Bypass available with inline or inline accessible dual check
-Angle dual check available with 1", 1 1/2" or 2" tap in cap - with or without plug
-Ball valve available with attached brass handle
-Special flange to flange lay lengths available
-Assemblies shipped with two 1/8" EPDM rubber meter gaskets, and meter support brackets (assembly required)
-Not all combinations available, contact factory with your requirements.
-Most Meter Setters are Made to order and are not returnable.
-Please verify with the factory that the model number you have configured is available and meets your requirements.
11-12
800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com
53
Copper Meter Setters
Unions
5/8", 5/8" x 3/4", 3/4", or 1" | Double Purpose x Double Purpose
(Series 720, 723, 724, 725, 726, 730, 739, 743, 750, 753, 754, 755, 756, 760, 761, 762, 763, 764, 770)
Modeldescription
Modeldescription
720-C3
3/4" Flare union
720-24
1" -22 CTS Comp union with union Nut
720-C4
1" Flare union with union nut
720-Q3ASY
3/4" Q CTS Compression with union nut
720-F1
1/2" FNPT union
720-F4
1" FNPT union with union nut
720-D3
3/4" Double Purpose union
Flare or FNPT
720-M3
3/4" MNPT union
720-M4
1" MNPT union
720-S3
3/4" Solder union
720-S4
Modeldescript
720-33
3/4" -33 PEP Comp union
with union nut
720-43
3/4" -44 PVC Comp union
with union nut
720-53
3/4" -55 IP Comp union
with union nut
40-N
3/4" Union nut only
20G3
3/4" Double Purpose Gasket
720-J3
3/4" C903* Comp union
720-G3
3/4" G CTS Comp union
1" Solder union
1" Meters
720-Q3
3/4" Q CTS Comp union
40-4N
1" Union nut
720-T3
3/4" T CTS Comp union
740-4D4
1" Double purpose union flare or FNPT
(also used on 5/8" x 3/4", 3/4" meter
sets with 1" Double purpose connection)
720-T4
1" T CTS Comp union with union nut
740-4M4
740-4M5
1" MNPT union
1 1/4" MNPT union
720-Z3
escription
3/4" 3Q PEP Comp union with union nut
740-4S4
1" Solder union
720-23
3/4" -22 CTS Comp union
40G4
1" Double purpose gaskets
OPTIONS
-Insert stiffeners are required on all flexible plastic connections.
-Note: Insetters normally supplied with end connections. The table above is for ordering replacement couplings.
Note: Connections require gasket union nut connector
54
800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com
11-12
Copper Meter Setters
Idlers
C - Female Iron Pipe Thread
B
B
B
B
A
A
Meter Idler
Air Release / Vac Idler Tee
MODEL
METER
A
B MODEL
740MJ05★ 5/8"
7 1/2" 3/4" 740MJ10 x 10.12
40MJ05PVC
5/8" 7 1/2" 3/4" 740MJ10 x 13.00
740MJ07◆
5/8" x 3/4" 7 1/2" 1" 740MJ10 x 18.25
740MJ07 x 4.00
-- 4.001" 740MJ613
40MJ07PVC
5/8" x 3/4" 7 1/2" 1" 740MJ703
740MJ09◆
3/4" 9"1" 740MJ704
40MJ09PVC
3/4" 9"1" 740MJ706
740MJ10
1"
10 3/4" 1 1/4" 740MJ707
40MJ10PVC
1"
10 3/4" 1 1/4" 740MJ710
740MJ10 x 7.50
--
7.50 1 1/4" 740MJ711
740MJ10 x 9.50
--
9.50 1 1/4" 740MJ717
◆One piece casting
METER
--
--
--
1 1/2"
--
--
--
--
--
--
2
A
10.12
13.00
18.25
13.00
3.0
4.0
6.0
7.0
10.0
11.0
17.0
B
1 1/4"
1 1/4"
1 1/4"
1 1/2" Oval Flange
2" Oval Flange
2" Oval Flange
2" Oval Flange
2" Oval Flange
2" Oval Flange
2" Oval Flange
2" Oval Flange
MODEL METER A
B
715AV13 x 7.50
5/8"
7 1/2"
3/4"
715AV23 x7.50 5/8" x 3/4" 7 1/2"
1"
715AV33 x9.003/4" 9" 1"
715AV44 x10.75
1
10 3/4"
1 1/4"
715AV63 x7.50
1 1/2"
7 1/2" 7 1/2" Oval Flange
715AV64 x7.50
1 1/2"
7 1/2" 7 1/2" Oval Flange
715AV73 x7.00
2"
7"
2" Oval Flange
715AV74 x7.00
2"
7"
2" Oval Flange
C
3/4"
3/4"
3/4"
1"
3/4"
1"
3/4"
1"
★Wrought Copper
Gaskets
MODEL
DESCRIPTION
18-G15/8"Rubber
18-G1F5/8" Fiber
18-G1L 5/8" Waxed Leather
18-G2 3/4" Rubber
18-G2F 3/4" Fiber
18-G2L 3/4" Waxed Leather
18-G41" Rubber
18-G4F1" Fiber
18-G4L 1"
Waxed Leather
MODEL
DESCRIPTION
18-G6 1 1/2"
18-G72"
4620G 1 1/2"
4620G2"
11-12
METER
SIZE
5/8"
5/8"
5/8"
5/8" x 3/4" or 3/4"
5/8" x 3/4" or 3/4"
5/8" x 3/4" or 3/4"
1"
1"
1"
METER
SIZE
Flange-Rubber
1 1/2"
Flange-Rubber
2"
Round-Rubber
1 1/2"
Round-Rubber
2"
Two drop in flange
gaskets furnished.
Two meter support
brackets furnished.
2" Meter Flanges have
slotted bolt holes to fit
1 1/2" or 2" meters.
800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com
55
Copper Meter Setters
Setters
1 1/2" & 2" METERS
Other meter lay lengths must be specified. An additional 3/8" is added to top spacing to allow for gaskets: Standard 2" top spacing = 17 3/8".
Contact factory for: 360º turn valve, handle for ball valve, dielectric connections, check valve in bypass test valve solder to tube.
Top view less valves
No Bypass (–)
Low Bypass (B)
Meter Size
11⁄2"2"
Standard Lay Length
13"
Offset High Bypass (R)
17"
Features
1. All ball valves have lockwings.
6. Two drop in flange gaskets furnished.
11. All copper tubing is “K” weight.
2. 1" copper cross tube is standard for no by-pass setters.
7. Two meter support brackets furnished.
12. For special setting or resetting requirements, contact factory.
3. 1" brace eyes are standard.
8. Other vertical heights available, contact factory.
4. 1 1/2" bypass available on FNPT meter setters, contact factory.
9. 1 1/4" bypass has 1" x 1" x 1 1/4" ball valve.
5. 2" Meter flanges have slotted bolt holes to fit 1 1/2" or 2" meters.
10. Flanged elbow can be supplied with 1" top tap for test valve. Contact factory.
NOTE: 2" meter setters can be easily converted to 11⁄2" meter setters by cutting 4" out of 1" cross tube and/or bypass cross tube. Order 20A76 adapter kit to convert bottom inlet and outlet connections from 2" FNPT to 1 1/2" FNPT. Two bushings are provided with each kit, thread sealant should be used.
OPTIONS
- Insert stiffeners are required on all flexible plastic connections
- Not all combinations available, contact factory.
56
800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com
11-12
Copper Meter Setters
Horizontal Tandem Styles
Multiple End Connections
Series 750, 751, 752, 753, 754, 755, 756, 757, 758, & 759
Meter Sizes:
5/8", 5/8" x 3/4", 3/4" and 1"
Heights: 07", 09", 12", 15", 18", 21", 24"
12" minimum on 1 meter
Other heights on special order
Meter Valve/Nut Options:
A
F
K
P
Q
N
= Check valve with plain meter nut (no lip) on outlet
= Angle dual check valve with plain meter nut (no lip) on outlet (ASSE 1024)
= Full port angle lockwing ball valve 300 PSIG
= Full port angle dual check valve (ASSE 1024)
= Angle lockwing ball valve with plain meter nut (no lip)
= Flanged tubing with plain meter nut (no lip)
Inlet/Outlet Options:
All tandem setters are available with the same bottom bar inlet/outlet options as
our standard horizontal copper meter setter. See Table I.
TABLE II
TABLE I
Page
Series 750 See Series 720................................................. 4-5
Series 751 See Series 721................................................. 6-7
Series 752 See Series 722................................................. 8-9
Series 753 See Series 723.............................................10-11
Series 754 See Series 724.............................................12-13
Series 755 See Series 725.............................................14-15
Series 756 See Series 726.............................................16-17
Series 757 See Series 727.................................................. 18
Series 758 See Series 728.............................................20-21
Series 759 See Series 729.............................................22-23
Series 750R See Series 730.............................................24-25
Series 751R See Series 731.............................................26-27
Series 752R See Series 732.............................................28-29
Series 759R See Series 737.............................................30-31
Series 758R See Series 738.............................................32-33
Series 759 See Series 739 ............................................34-35
Series 760 See Series 760-763.....................................36-37
Series 764 See Series 764.............................................38-39
Meter Size
Device Length
(FNPT x FNPT)
Minimum
Recommended
Inside Pit Diameter
5/8"
5/8" x 3/4"
3/4"
1"
4" to 5"
4" to 5"
4" to 5"
5" to 6"
18"
18"
20"
21"
To order a 5/8" x 3/4" tandem meter setter having 3/4" double purpose
ends, inlet valve only and a 7" height with 4" to 5" device length, you would
order as follows:
11-12
750 -2 07 QN DD 33
800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com
57
Copper Meter Setters
Tandem Options
5/8", 5/8" x 3/4", 3/4", and 1" sizes
All A.Y. McDonald tandem copper setters are designed to provide the user with the option of placing an auxiliary device in addition to
a water meter in a space as small as 18" in diameter (see Table I). The auxiliary device could be a pressure regulator, pressure relief
valve, backflow preventer, etc. Table I shows typical lay lengths available for these devices. Other lengths can be provided. Contact our
customer service department for details.
- Standard centerline spread for 5/8", 5/8" x 3/4", 3/4" meters is 7". 1" meter is 9"
- Tandem meter setter “S” bar (4619S-size) and brass adapters (74619-size) come as standard when ordering tandem resetters, but are also available separately (see below). Contact factory.
- Resetters with cross-over meter sizes are available, contact factory.
Tandem "S" Bar
4619S 5/8"
- for use with 5/8" meter tandem
4619S 5/8" x 3/4" - for use with 5/8" x 3/4" meter tandem
4619S 3/4"
- for use with 3/4" meter tandem
Above items for use with 4"-5" device
4619S 1
- for use with 1" meter tandem
Above item for use with 5"-6" device
7"
9"
TABLE I
Meter Size
Device Length
(FNPT x FNPT)
Minimum
Recommended
Inside Pit Diameter
5/8"
5/8" x 3/4"
3/4"
1"
4" to 5"
4" to 5"
4" to 5"
5" to 6"
18"
18"
20"
21"
"S" Bar Adapter
Two pieces required per
device
74619 5/8"- (5/8" meter x 3/4" NPT)
74619 3/4"- (5/8" x 3/4" or 3/4" meter x 3/4" NPT)
74619 1" - (1" meter x 1" NPT)
Spread for 5/8", 5/8"x 3/4" and 3/4" Meters
Spread for 1" Meters
Note: Special length cross tubes and inverted tandem
cross tubes are available, contact factory.
Setters with Bypass
Available for 5/8" - 1" Meters
with multiple end connections.
Contact factory
58
800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com
11-12
Copper Meter Setters
NO-LEAD AHEAD
Are you ready?
WHAT IS No-lead BRASS?
A.Y. McDonald Mfg. Co. No-Lead Brass products meet the requirements of UNS
Copper Alloy C89833 per ASTM B584-09A. UNS Copper Alloy C89833 Mechanical
properties and Chemical composition have been certified by an independent
testing agency and are listed in ASTM specification B584-09A Copper Alloy Sand
Casting for General Applications (compositions and mechanical properties).
A.Y. McDonald’s No-Lead Brass contains a high percentage of copper and three
main alloying elements - Zinc, Tin and Bismuth.
Zinc is a potent alloying element in copper, imparting strength and hardness.
Tin is a potent solid-solution strengthener in copper, even more so than zinc.
Unlike zinc, tin also improves corrosion resistance.
Bismuth acts very much like lead in many respects. Unlike lead, Bismuth is not
known to be toxic in humans. Bismuth is lead’s neighbor on the periodic chart of
elements, making it’s behavior during casting and solidification similar. Bismuth
is nearly insoluble in copper and causes machining chips to break up into small,
easily removed particles.
How Can A.Y. Help?
A.Y. McDonald is committed to educating and assisting our customers with this transition to no-lead brass. We want to ensure
that this law doesn’t negatively impact your bottom line. As the first manufacturer in the industry to offer and market a complete
line of no-lead brass products – we have over 20 years of experience working in no-lead. During that time, we helped the city of
Los Angeles become the first in the country to transition to no-lead brass. Now we want to share our years of knowledge and
experience with you.
For more information on the industry’s switch to no-lead brass and how you can make the transition successfully,
please go to NOLEADBRASS.com.
For more information on NO-LEAD BRASS and how you can make the transition successfully; or for other product, pricing, and
industry information, sign-up to receive AY ALERTS at www.aymcdonald.com
11-12
800.292.2737 | FAX 800.832.9296 | [email protected] | aymcdonald.com
59
A.Y. McDonald Mfg. Co. is a leading manufacturer of Waterworks Brass, Plumbing Valves,
Pumps and Water Systems, and High Pressure Gas Valves and Meter Bars. The Company has
distinguished itself with a proud tradition of quality and reliability since its founding in 1856.
The mission of A.Y. McDonald Mfg. Co., in the words of our founder, is “to make good products
and sell them honestly.” We, the stockholders and employees, accomplish this by extending
the McDonald family culture through excellent customer service and by focusing on our
customers’ needs.
WARNING: It is unlawful in CALIFORNIA & VERMONT (effective 1/1/2010); MARYLAND (effective 1/1/2012); LOUISIANA
(effective 1/1/2013) and the UNITED STATES OF AMERICA (effective 1/4/2014) to use any product in the installation or
repair of any public water system or any plumbing in a facility or system that provides water for human consumption if the wetted
surface area of the product has a weighted average lead content greater than 0.25%. This prohibition does not extend to service saddles
used in California, Louisiana or under USA Public Law 111-380.
More than a brand. We’re a family.
11/12
aymcdonald.com
1-800-292-2737
[email protected]