Sartolab DY 0.15L

User Manual
Sartolab DY 0.15L
83057-549-15
Contents
Liability..................................................................................... 2
Directions for Use.................................................................. 3
Introduction............................................................................ 3
Method – Description ......................................................... 4
Method – Images ................................................................. 5
Order Numbers ..................................................................... 6
Application Support............................................................. 7
Return of Used Products..................................................... 7
Liability
The products described in this document are intended
to be used for the clarification of mammalian and
microbial cell cultures. Sartorius shall not assume any
liability if Sartolab® products have been subjected
to improper use. The use of this product for any other
applications or in another manner than described
in this manual may result in personal injury or
malfunction of the product. Please follow the
instructions in this user manual to ensure your own
safety and to obtain optimal filtration results.
In the interest of product development, we reserve
the right to make changes.
2
Contents | Liability
Directions for Use
The purpose of this document is to outline the
­appropriate method for using the Sartolab DY 0.15L
kit for body feed filtration.
The device described in the document is intended to
be used for the clarification of animal and microbial
cell cultures and other fluids of biological origin.
Introduction
The addition of filter aids like diatomaceous earth
(DE) to increase the total throughput in clarification
applications is used in many different industries.
DE is a highly porous, insoluble material and can
be used as a spacer between solid particles. While
these p
­ articles are entrapped in a filter cake, liquid,
including dissolved substances, can easily flow
through the filter cake by passing through the porous
structure of the DE particles.
The Sartolab DY 0.15L kit is appropriate for the
­clarification of cell cultures containing a maximum
of 12% wet biomass.
Directions for Use | Introduction
3
Method – Description
4
Method – Description
1
Connect your Sartolab DY 0.15L filter unit to
a vacuum system, e.g. Microsart® e-jet pump,
order no. 166MP-4 (vacuum max. 0.4-bar).
2
Take a 150 mL sample of your cell culture.
3
Optional step: When using mammalian cell
lines producing therapeutic antibody product,
it is recommended to adjust your sample to a
pH of 5 using acetic acid (2M or 30%) and to
stir the suspension for a minimum of 45 min.
before filtration. This will allow correct precipitation of small particle portions. Gentle mixing
with a magnetic stirring bar is recommended.
4
Add your sample to 1 bottle of DE and vortex
to homogenize. You need to perform this
procedure in a ventilated area, such as under a
fume hood, to avoid inhaling dust particles.
5
Add your homogenized suspension to the
Sartolab DY 0.15L filter unit and turn on the
vacuum pump. Wait until your filter unit is
completely drained.
6
Optional step: To avoid any further precipitation reaction after filtration, adjust the filtrate
pH back to pH 7 using NaOH (1M).
7
Discard the top half of the Sartolab filter unit
containing the cell and diatomaceous earth
mixture in accordance with your local legal
regulations for waste disposal.
Method – Images
1
2
3
4
5
6
7
Waste
Waste
Waste
Method – Images
5
Order Numbers
Description
Order Number
Sartolab DY 0.15L kit
180K1----------V
Related Products
Sartoclear Dynamics® DE bags
DE Contents
Order Number
0.5 kg
29Z-B00005
1.5 kg
29Z-B00015
5 kg
29Z-B00050
10 kg
29Z-B00100
Sartoclear Dynamics® kit
29Z-K00001
Flexel® 3D Magmix bags
Volume
Order Number
100 L
FMB115027
200 L
FMB115026
400 L
FMB115025
650 L
FMB115024
1,000 L
FMB115022
Forklift
Trolley with integrated
lifting device
2ZG---0003
Adapter
2ZG---0004
Sartoclear Dynamics filter
29Z-H00001
Sartoclear manifold set
29Z-S00001
Sartoclear pilot filter holder
2ZGL--0005
Drip pan for Sartoclear
pilot filter holder
2ZGL--0008
®
®
®
®
6
Order Numbers
Applications Support
Contact your local Sartorius ­representative to obtain
general information and technical data. We will be
more than happy to assist you in performing your
trial filtration run – just ask for one of our team of
application specialists based around the globe.
Return of Used Products
All used materials must be properly sterilized prior to
shipping to Sartorius. This will enable our staff to
handle them with minimal risk during inspection of
these products. The law requires that a return shipment form (available through your local Sartorius
representative) be completed prior to shipping of
used filter materials.
Thank you for selecting and working with Sartorius.
We sincerely appreciate your business.
Applications Support | Return of Used Products
7
Sartorius Lab Instruments GmbH & Co. KG
Weender Landstrasse 94–108
37075 Goettingen, Germany
Phone +49.551.308.0
Fax +49.551.308.3289
www.sartorius.com
Copyright by
Sartorius Lab Instruments GmbH & Co. KG,
Goettingen, Germany.
All rights reserved. No part of this
­publication may be r­ eprinted or translated in
any form or by any means without the prior
written ­permission of Sartorius.
The status of the information, s­ pecifications
and illustrations in this m
­ anual is indicated
by the date given below. Sartorius
reserves the right to make c­ hanges to the
technology, features, s­ pecifications and
design of the equipment without notice.
Status:
02 | 2015,
Sartorius Lab Instruments GmbH & Co. KG,
Goettingen, Germany
Printed in the EU on paper bleached
without chlorine. | W
Publication No.: SL-6520-e150202