19 CP-1475 - Add patient defined term for Ultrasound Acquisition Geometry 1 Status Final Text 2 Date of Last Update 2015/11/10 3 Person Assigned David Clunie 4 5 Page 1 mailto:[email protected] Submitter Name 6 David Clunie mailto:[email protected] 7 Submission Date 8 Correction Number CP-1475 9 Log Summary: Add patient defined term for Ultrasound Acquisition Geometry 10 Name of Standard 11 PS3.3 2015c 12 Rationale for Correction: 13 14 The Enhanced US Volume object added an Ultrasound Frame Of Reference Module with a descriptive term describing the characteristic of the ultrasound acquisition geometry. 15 16 It is useful to be able to identify when the geometry is patient relative, to signal that the geometry is the same as the patient-relative coordinate system. 17 Correction Wording: 18 2015/02/27 - Final Text - 45 CP-1475 - Add patient defined term for Ultrasound Acquisition Geometry Page 2 1 Amend DICOM PS3.3 as follows (changes to existing text are bold and underlined for additions and struckthrough for removals): 2 A.59.4 Enhanced US Volume Functional Group Macros Table A.59-2. Enhanced US Volume Functional Group Macros 3 4 Functional Group Macro Section Usage 5 ... ... ... 6 7 8 Plane Position (Patient) C.7.6.16.2.3 UC - Required if Ultrasound Acquisition Geometry (0020,9307) has a value of PATIENT. May be present otherwise. See Section A.59.4.1.2. 9 10 11 Plane Orientation (Patient) C.7.6.16.2.4 UC - Required if Ultrasound Acquisition Geometry (0020,9307) has a value of PATIENT. May be present otherwise. See Section A.59.4.1.2. 12 ... ... ... 13 14 Plane Position (Volume) C.7.6.16.2.21 M - May not be used as a Shared Functional Group. See Section A.59.4.1.2. 15 16 Plane Orientation (Volume) C.7.6.16.2.22 M - May not be used as a Per-Frame Functional Group. See Section A.59.4.1.2. 17 ... ... ... 18 A.59.4.1 Enhanced US Volume Functional Group Macros Content Constraints 19 A.59.4.1.2 Plane Position (Volume) and Plane Orientation (Volume) Macros 20 21 22 23 24 25 26 Image Position (Volume) (0020,9301) first value (X) shall be zero and second value (Y) shall be zero. Image Orientation (Volume) (0020,9302) values shall be 1\0\0\0\1\0. This ensures that the origins of each frame lies on the Volume Frame of Reference ZV axis, the rows of each frame are parallel to the Volume Frame of Reference XV axis, and the columns of each frame are parallel to the Volume Frame of Reference YV axis. 27 Adjacent planes in the volume shall be equally spaced in the Z direction. 28 Note 29 1. More than one frame may be encoded for the same plane, for example, with a different temporal or cardiac cycle position. 30 31 2. Frames with the same value of Image Position (Volume) (0020,9301) will also have the same second value of Dimension Index Value (the spatial position Dimension); See ???. 32 33 34 35 36 37 3. When Ultrasound Acquisition Geometry (0020,9307) has a value of PATIENT, the Plane Position (Patient) and Plane Orientation (Patient) functional group macros will be present. They may contain attributes with identical values to the corresponding attributes in the Plane Position (Volume) and Plane Orientation (Volume) functional group macros if the frames are transverse and the origin of the Patient Coordinate System and the volume coincide (i.e., to remain compliant with the first paragraph of this section, which constrains the origin and orientation of the Volume Frame of Reference. 38 C.8.24.2 Ultrasound Frame of Reference Module 39 Table C.8.24.2-1 specifies the attributes of the Ultrasound Frame Of Reference Module. See ???. Table C.8.24.2-1. Ultrasound Frame of Reference Module Attributes 40 41 42 43 44 Attribute Name Volume Frame of Reference UID Tag Type (0020,9312) 1 Attribute Description Uniquely identifies this Volume Frame of Reference. - Final Text - 57 CP-1475 - Add patient defined term for Ultrasound Acquisition Geometry 1 Attribute Name Tag Type 2 15 3 Ultrasound Acquisition Geometry (0020,9307) 1 Page 3 Attribute Description Characteristic of the ultrasound acquisition geometry. Defined Terms: 4 5 6 7 8 APEX PATIENT there exists an apex of the scan lines from which the volume data was acquired. the ultrasound acquisition geometry is patient relative 9 Note 10 11 12 13 14 When the value is PATIENT, the Plane Position (Patient) and Plane Orientation (Patient) functional group macros will be present, and may or may not contain attributes with identical values to the corresponding attributes in the Plane Position (Volume) and Plane Orientation (Volume) functional group macros; see Section A.59.4.1.2. 16 17 18 19 20 Apex Position (0020,9308) 1C 21 22 49 23 Position of the apex (or phase center) of the acquisition geometry, encoded as xA, yA, and zA in mm units in the Volume Frame of Reference. The apex (xA, yA, zA) may be located in the volume or exterior to it. Required if value of Ultrasound Acquisition Geometry (0020,9307) is APEX. Volume to Transducer Relationship (0020,930B) 1C Relationship between the transducer and the acquired volume. Enumerated Values: 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 FIXED 47 48 Required if the transducer position and/or orientation relative to the volume is not constant. May be present otherwise. 50 51 52 53 54 55 56 The transducer position and orientation relative to the volume is constant and specified by Volume to Transducer Mapping Matrix (0020,9309). POSITION_VAR The transducer position relative to the volume varies during acquisition and the position specified by Volume to Transducer Mapping Matrix (0020,9309) is a nominal value. The transducer orientation relative to the volume is constant and specified by Volume to Transducer Mapping Matrix (0020,9309). ORIENTATION_VAR The transducer orientation relative to the volume varies during acquisition and the orientation specified by Volume to Transducer Mapping Matrix (0020,9309) is a nominal value. The transducer position relative to the volume is constant and specified by Volume to Transducer Mapping Matrix (0020,9309). VARIABLE The transducer position and orientation relative to the volume varies during acquisition and the position and orientation specified by Volume to Transducer Mapping Matrix (0020,9309) are nominal. Volume to Transducer Mapping Matrix (0020,9309) 1 A 4x4 rigid transformation matrix that maps the Volume Frame of Reference homogeneous coordinate system (XV, YV, ZV) to the Transducer Frame of Reference homogeneous coordinate system (XX,YX, ZX). Matrix elements shall be listed in row-major order. See ??? for details. - Final Text - 26 1 2 3 CP-1475 - Add patient defined term for Ultrasound Acquisition Geometry Attribute Name Patient Frame of Reference Source Tag Type (0020,930C) 1C Page 4 Attribute Description Indicates how the supplied Image Position (Patient) (0020,0032) and Image Orientation (Patient) (0020,0037) values are obtained. 4 Enumerated Values: 5 6 7 8 9 10 11 12 TABLE 13 14 Required if either Image Position (Patient) (0020,0032) or Image Orientation (Patient) (0020,0037) is present. A positioning device, such as a gantry, was used to generate these values. ESTIMATED Estimated patient position / orientation (e.g., estimated by the user), or if reliable information is not available. REGISTRATION Acquisition has been spatially registered to a prior image set. 15 17 16 Table Frame of Reference UID (0020,9313) 1C 18 19 20 21 22 23 Volume to Table Mapping Matrix (0020,930A) 1C 24 25 Uniquely identifies this Table Frame of Reference. Required if Patient Frame of Reference Source (0020,930C) is TABLE. A 4x4 rigid transformation matrix that maps the Volume Frame of Reference homogeneous coordinate system (XV,YV, ZV) to the Table Frame of Reference homogeneous coordinate system (XT,YT, ZT). Matrix elements shall be listed in row-major order. See ??? for details. Required if Patient Frame of Reference Source (0020,930C) is TABLE. - Final Text -
© Copyright 2026 Paperzz