2AV 2`X 2` SMD - Acuity Brands

Catalog
Number
Notes
FEATURES & SPECIFICATIONS
INTENDED USE — The Avante side-mounted diffuser is for use as general area lighting and for private
offices. Especially suited for conference rooms, corridors and reception areas where soft distinctive lighting
is required. Certain airborne contaminants can diminish integrity of acrylic. Click here for Acrylic
Environmental Compatibility table for suitable uses.
CONSTRUCTION — Housing is gloss white enamel on cold rolled steel. All edges hemmed or rounded.
All shieldings pivot on light traps and swing down for easy lamp access.
Molded light traps prevent light leaks between shielding and endplates.
OPTICAL SYSTEM — Matte white polyester powder paint finished reflector provides uniform light
distribution. Optional low brightness diffuse aluminum stepped reflector available.
All diffusers control direct light distribution and glare by shielding lamps from direct view.
Metal diffuser staggered round holes (MDR) 52% open perforated metal with .075” diameter holes backed
with white acrylic diffuser.
Metal diffuser aligned mini slots (MDM) 46% open perforated metal backed with white acrylic diffuser.
ELECTRICAL SYSTEM — All ballasts supplied are class P, thermally protected, resetting, HPF, non-PCB, UL
Listed. Ballasts are sound rated A. Standard combinations conform to UL 935. All T5 and T5HO ballasts are
program start.
Step-level dimming option allows system to be switched to 50% power for compliance with common energy
codes while maintaining fixture appearance.
INSTALLATION — Trims available for standard 1” and 9/16” tee bar or screw slot grids.
Fixtures can be row mounted end-to-end.
Drywall ceiling adapters available.
LISTING — UL Listed to US and Canadian safety standards. Chicago Plenum approved and NYC approved
(see Options).
Avante is covered by one or more of the following patents: 5,988,829; 399,586; 411,641; 413,402;
2,212,513; 87,513.
WARRANTY — 1-year limited warranty. Complete warranty terms located at
www.acuitybrands.com/CustomerResources/Terms_and_conditions.aspx.
Actual performance may differ as a result of end-user environment and application.
Note: Specifications subject to change without notice.
Type
2AV 2’X 2’ SMD
SIDE-MOUNTED DIFFUSER
LINEAR FLUORESCENT
T5 OR T5HO
2 OR 4 LAMPS
Specifications
Length: 24” (602)
Width: 24” (602)
Diffuser Width: 6” (153)
Depth: 5-1/2” (140)
All dimensions are inches (millimeters) unless otherwise specified.
ORDERING INFORMATION
Example: 2AV G 2 24T5HO MDR SMD MVOLT GEB10PS
For shortest lead times, configure products using bolded options.
2AV
SMD
Series
Trim type
2AV 2’ wide
Voltage
G
ST
Air function
(blank) Static (no air
function)
A
Air return/supply
Grid trim
Screw slot
Number of lamps
2
4
Not included.
14T5
14W T5 (22”)
24T5HO 24W T5HO
(22”)
Diffuser
MDR
MDM
Lamp distribution
Metal diffuser, round holes
Metal diffuser, mini slots
SMD
Side-mounted
diffuser
Others available.
Options
347
MVOLT1
Others available.
GEB10PS
GEB115
GEB115S
ALG
EL14
GLR
LP_
Electronic ballast, < 10% THD, program start
1.15 ballast factor, two-lamp only2
1.15 ballast factor, step-dim2
Acrylic litter guard3
Emergency battery pack (nominal 1200 lumens, see Life Safety section)4
Internal fast-blow fuse5
Lamped. Specify lamp type and color
Accessories: Order as separate catalog number.
DGA22
Lamp type
Drywall ceiling adapter, unit installation. Use G trim plus DGA accessory for fixture
trim flange and fixture support in plaster or plasterboard ceilings.
FLUORESCENT
PWS1836
QFC
NYC
CP
Reflector option
ASR
6’ prewire, 3/8” dia., 18-gauge, 3 wires
Quick-Flex® cable5
New York City approved
Chicago Plenum approved
Aluminum stepped reflector
Notes
1. MVOLT (120 - 277 volt).
2. For two-lamp 14T5 only.
3. Refer to options and accessories section for more detailed information.
4. Not available in Canada.
5. Must specify voltage, 120 or 277.
2AV 2X2 SMD T5
2AV 2x2 SMD Direct/Indirect Lighting
2AV G 2 24T5HO MDR SMD, (2) 24W T5HO lamps, 1760 lumens per lamp, s/m 1.2 (along) 1.3 (across), test no. LTL 10004
100
70°
200
300
50°
400
500
600
700
10°
0°
30°
CP Summary
0° 90
0° 749 749
5° 741 753
15° 715 730
25° 662 690
35° 580 629
45° 474 559
55° 353 485
65° 230 407
75° 122 314
85° 24 66
0
90 0
pf
pc
pw
0
1
2
3
4
5
6
7
8
9
10
RCR
90°
Coefficients of Utilization
20%
80%
70%
50%
70%50%30% 50%30%10% 50%30%10%
79 79 79
77 77 77
74 74 74
71 68 65
67 64 61
64 61 59
65 59 54
57 53 49
55 51 48
59 51 45
50 45 41
48 44 40
53 45 39
44 39 34
43 38 34
49 40 34
39 34 29
38 33 29
45 36 30
35 30 25
34 29 25
42 33 27
32 26 22
31 26 22
39 30 24
29 24 20
28 23 20
36 27 22
27 22 18
26 21 18
34 25 20
25 20 16
24 19 16
Zonal Lumen Summary
Zone
Lumens % Lamp % Fixture
0° - 30°
585
16.6
25.1
0° - 40°
962
27.3
41.2
0° - 60°
1735
49.3
74.4
0° - 90°
2333
66.3
100.0
90° - 180°
0
0.0
0.0
0° - 180° 2333
66.3
100.0
Efficiency: 66.3%
90°
2AV G 4 24T5HO MDR SMD, (4) 24W T5HO lamps, 1760 lumens per lamp, s/m 1.2 (along) 1.3 (across), test no. LTL 10007
200
70°
400
600
50°
800
1000
1200
10°
30°
0°
CP Summary
0°
90
0° 1287 1287
5° 1274 1291
15° 1229 1256
25° 1139 1188
35° 998 1086
967
45° 818
839
55° 610
705
65° 396
544
75° 208
112
85° 42
0
0
90
pf
pc
pw
0
1
2
3
4
5
6
7
8
9
10
RCR
90°
Coefficients of Utilization
20%
80%
70%
50%
70%50%30% 50%30%10% 50%30%10%
68 68 68
66 66 66
63 63 63
62 59 56
57 55 53
55 53 51
56 51 46
50 46 42
47 44 41
51 44 39
43 39 35
41 38 34
46 39 34
38 33 29
37 32 29
42 35 29
34 29 25
33 28 25
39 31 26
31 26 22
30 25 22
36 28 23
28 23 19
27 22 19
34 26 21
25 20 17
24 20 17
31 24 19
23 19 15
23 18 15
29 22 17
21 17 14
21 17 14
Zonal Lumen Summary
Zone
Lumens % Lamp % Fixture
0° - 30°
1007
14.3
25.1
0° - 40°
1657
23.5
41.2
0° - 60°
2992
42.5
74.4
0° - 90°
4020
57.1
100.0
90° - 180°
0
0.0
0.0
0° - 180° 4020
57.1
100.0
Efficiency: 57.1%
90°
2AV G 4 24T5HO MDR SMD ASR, (4) 24W T5HO lamps, 1760 lumens per lamp, s/m 1.3 (along) 1.6 (across), test no. LTL 10006
100
70°
200
300
400
50°
500
600
700
800
900
10°
0°
30°
CP Summary
0° 90
0° 764 764
5° 754 771
15° 740 776
25° 697 786
35° 621 785
45° 514 762
55° 392 713
65° 259 629
75° 153 469
85° 28 85
0
90 0
pf
pc
pw
0
1
2
3
4
5
6
7
8
9
10
RCR
90°
Coefficients of Utilization
20%
80%
70%
50%
70%50%30% 50%30%10% 50%30%10%
48 48 48
47 47 47
45 45 45
43 41 39
40 38 37
38 37 36
39 35 32
34 32 29
33 31 29
35 31 27
30 27 24
29 26 23
32 27 23
26 23 20
25 22 20
29 24 20
23 20 17
22 19 17
27 21 17
21 17 15
20 17 14
25 19 15
19 15 13
18 15 13
23 17 14
17 14 11
17 13 11
22 16 12
16 12 10
15 12 10
20 15 11
14 11 09
14 11 09
Zonal Lumen Summary
Zone
Lumens % Lamp % Fixture
0° - 30°
628
8.9
22.1
0° - 40°
1064
15.1
37.5
0° - 60°
2037
28.9
71.7
0° - 90°
2840
40.3
100.0
90° - 180°
0
0.0
0.0
0° - 180° 2840
40.3
100.0
Efficiency: 40.3%
90°
*The LER (Luminaire Efficacy Rating) is the lumens per watt rating for this fixture. It is used to compare the energy efficiency of various products. This photometric report is based upon IES testing procedures, as stated in LM-41-1998. The reported
lumen rating is based upon lamp manufacturer’s published lumen output for the cold spot temperature measured during lamp calibration.
MOUNTING DATA
Ceiling Type
Appropriate Trim Type
Exposed grid tee (1’ and 9/16”)
G
Concealed grid tee
G
Screw slot
ST
Plaster or plasterboard
G*
*DGA accessory available to provide ceiling trim flange and fixture support for plaster or plasterboard ceiling. Recommended rough-in dimensions for DGA
installation is 24-3/4” x 24-3/4” (Tolerance is +1/8”, -0”).
FLUORESCENT: One Lithonia Way Conyers, GA 30012 Phone: 800.858.7763 Fax: 770-929-8789 www.lithonia.com
2AV 2X2 SMD T5