Change Proposal Reference DTC CP 3397 Change Proposal Details Version Number 1.0 Change Type Normal Change Title Additional flow notes for the J0171 Reading Type 'X' value Change Summary DTC CP 3389 was accepted at MDB which introduced a new value of ‘X’ to the J0171 ‘Reading Type’ Data Item to allow meter reads to be flagged as being obtained remotely when passed to the Data Collector for the use in “routine” settlement purposes, or where a CoS read is required to complete this process via a D0086. Following MDBs decision, MIF132 was raised by a Meter Operator requesting clarification in the use and population of the new ‘X’ value for MOPs. At IREG_13_1015 the group discussed the use of the new value and agreed MOPs may use the new ‘X’ value for certain instances of routine reads however guidance should be provided to aid MOPs in the instances the new value of ‘X’ should be used and how to populate the D0010 where an ‘F’ or ‘I’ read is obtained remotely or physically. Date Raised Related MRA Issues Number th 16 October 2013 Originator Reference Related Preassessment Number Description Of Change Flow Notes Flow notes will be added to the 17 affected flows to ensure that rules for the use of the new read type will be clear for parties: Meter Operators should use the ‘X’ value where a requested read is obtained remotely, without meter reconfiguration, in place of a Special read. Where a Meter Operator obtains an ‘I’ or ‘F’ read, the J0012 Additional Information Data item should be populated with ‘Obtained Remotely’ or ‘Obtained Physically’ as appropriate. The new reading type would be used on the D0010, D0071, D0086, D0300, D0301 and D0311 only; however for consistency the flow notes are to be included on all 17 data flows (listed in the impact assessment section of the CP). Change Proposal Reference DTC CP 3397 Impact Assessment The values of reading type are: A - Actual Change of Supplier Read C - Customer own read D - Deemed (Settlement Registers) or Estimated (Non-Settlement Registers) F - Final I - Initial M - MAR O - Old Supplier's Estimated CoS Reading P - Electronically collected via PPMIP Q - Meter Reading modified manually by DC R - Routine S - Special T - Proving Test Reading W - Withdrawn X – Remotely Obtained Read Z - Actual Change of Tenancy Read There are 17 flows that use J0171 Reading Type as follows: 1. 2. 3. 4. 5. 6. D0004 – Notification of Failure to Obtain Reading D0071 – Customer Own Reading or Supplier Estimated Reading on Change of Supplier D0010 – Meter Readings D0086 – Notification of Change of Supplier Readings D0238 – Request and Information for Revenue Protection Investigation D0300 – Disputed Readings or Missing Readings on Change of Supplier Change Proposal Reference 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. DTC CP 3397 D0301 – Erroneous Transfer Communication D0307 – Debt Information D0309 – Confirmation of Debt Assigned D0311 – Notification of Old Supplier Information D0072 – Instruction to Obtain Change of Supplier Reading D0003 – Half Hourly Advances D0008 – Meter Advance Reconciliation Report D0139 – Confirmation or Rejection of Energisation Status Change D0192 – Readings and Settings from a Token or Key Meter D0202 – Readings and Settings from a Removed Smart Card Meter D0262 – Rejection of Disconnection Flow Notes Additional Flow notes will be added to the relevant flows to ensure that rules for the use of the new read type will be clear for parties: Meter Operators should use the ‘X’ value where a requested read is obtained remotely, without meter reconfiguration, in place of a Special read. Where a Meter Operator obtains an “F” or “I” read, the Additional Information field should be populated to state whether the read was taken remotely or physically using either “Obtained Remotely” or “Obtained Physically”. The new reading type would be used on the D0010, D0071, D0086, D0300, D0301 and D0311 only, however for consistency the flow notes are to be included on all 17 data flows. Originator Name Originator Company Originator Telephone Originator Email Originator’s view of Impacted Parties Originator’s view of Impacted on CAS Rachael Mottram obo IREG Gemserv 0207 090 7747 [email protected] Supplier Other Yes NHHDC / HHDC / MOA ECOES Impact No Green Deal Impact No Sponsor Name Dan Simons Sponsor Company EDF Energy Sponsor Telephone 07875 113701 Sponsor Email Distribution Yes [email protected] Settlements Yes Change Proposal Reference DTC CP 3397 Impact Assessment Proposed Date of Impact Assessment Closes Date Of Issue Implementation Details Implementation Date Implementation Technique 27 th February 2014 Parallel Test Start Date Big Bang Parallel Test End Date Affected D0004 /D0071 / D0010 / D0086 / D0238 / D0300 / D0301 / D0307 / D0309 / D0311 / D0072 / D0003 / D0008 / D0139 / D0202 / D0262 Data Flow Data Item DTC Version Affected J0171 Reading Type Domain Name Value Of Test Flag MAP MAP Version Affected Working Practice WPPS Version Affected E2E Reference Number E2E Version Affected MRA Clause MRA Version Affected Priority Provisions Affected Authority Consent Affected Codes And Agreements Code/Agreement version Affected Change Associations 10.7 Change Proposal Reference Associated Changes DTC CP 3397 Attachments
© Copyright 2026 Paperzz