Installation Instructions T/PC PRT Contact Temperature Sensor Important: Retain these instructions UNPACKING T/PC Installation Instructions TG100508 Installation 97 mm (3.82”) Dimensions 109 mm (4.29”) 1 2 m (6’6”) cable T /P C M A N U F A C T U R E D IN E U T R E N D C O N T R O L S Y S T E M S L T D U K 57 mm (2.24”) 2 Requirements measurement range /-40 /40 /110 /160 -40 °C to +50 °C (-40 °F to +122 °F) -10 °C to +40 °C (+14 °F to +104 °F) -10 °C to +110 °C (+14 °F to +230 °F) -10 °C to +160 °C (+14 °F to +320 °F) 0 %RH 95 %RH H O 2 Protection :IP67, NEMA6 2 m (6’6”) max T /P C M A N U F A C T U R E D IN E U T R E N D C O N T R O L S Y S T E M S L T D U K -40 °C to +50 °C (-40 °F to +122 °F) T/PC PRT Contact Temperature Sensor Installation Instructions TG100508A Issue 4/B 13/02/07 1 T/PC Installation Instructions Installation (continued) 3 b Tighten 2 screws Drill 2 pilot holes 85 mm (3.35”) a Fix to Wall 2 off No 6 (M3.5) screws Fix Probe 4 or use cable tie(s) (not provided) either use jubilee clip (provided) recommended use of thermally conductive paste Remove Lid 5 b a 6 Remove Connector Caution: This unit contains static sensitive devices. Suitable anti-static precautions should be taken throughtout the operation to prevent damage to the units. BS EN100015/ 1 Basic Specification: protection of electrostatic sensitive devices. 2 T/PC PRT Contact Temperature Sensor Installation Instructions TG100508A Issue 4/B 13/02/07 Installation Instructions T/PC Installation (continued) Insert Cable 7 or use M16 cable gland either use M20 flexible conduit 8 Wire to Controller IQ1xx, IQ2xx 24 Vdc Sensor IN polarity independent IQ system TP/I/22/HF/200 (Belden 8761) cable recommended. Terminal size 0.5 to 2.5 mm2 (14 to 20 AWG) I Terminate screen at IQ end only IQ3 0 (0 V) Sensor N (in) + (24 V) Analogue input channel linked for current (I) Note that if connecting to an IQ22x controller (including /ADL or /OC), do not connect directly to C (+24V), instead connect to AUX+ (+24V). 9 Replace Connector Replace Lid 10 b a Note that IP67 (NEMA6) rating is only achieved if the sensor is correctly installed with cable or conduit connection fully tightened. T/PC PRT Contact Temperature Sensor Installation Instructions TG100508A Issue 4/B 13/02/07 3 T/PC Installation Instructions Installation (continued) 11 Configure IQ IQ or IQ 12 IQ Configuration Manual 90-1533 Set up IQ Sensor Type It is recommended to use SET (Software Tool) for the setting of the sensor type module. For all IQ2 series controllers with firmware version 2.1 or greater, or IQ3 series controllers, the following SET Unique Sensor References should be used: (T/PC/-40) PRT I -40+50 (°C) PRT I -40+122 F (°F) (T/PC/40) PRT I -10+40 (°C) PRT I +14+104 F (°F) (T/PC/110) PRT I -10+110 (°C) PRT I +14+230 F (°F) (T/PC/160) PRT I -10+160 (°C) PRT I +14+320 F (°F) Alternatively enter scaling manually as defined in table below. For all other IQ controllers see Sensor Scaling Reference Card TB100521A tYpe Sensor digI/P Driver Function loGic Loop scHedule seQnc Analog digBit Knob sWitch Time Zone Oss User addRess intcoN calarM reView Plot calEndar Unit /-40 /40 /110 /160 = ? Y E Yn<CR> TYPE n :=? S=5 (characterise) Y= , E= , U= , L= , P= , I1= , I2= , O1= , O2= X <CR> 13 U L P x 1 2 ΔT IQ T /P C T R E N D C O N T R O L S Y S T E M S L T D U K 2 (current) 3 °C °F 50 122 -40 -40 2 2 Ox Ox -40 -40 50 122 2 (current) 3 °C °F 40 104 -10 14 2 2 Ox Ox -10 14 40 104 2 (current) 3 °C °F 110 230 -10 14 2 2 Ox Ox -10 14 110 230 2 (current) 3 °C °F 160 320 -10 14 2 2 Ox Ox -10 14 160 320 Disposal Test system M A N U F A C T U R E D IN E U input type Exponent Units Upper Lower Points Ix 4 20 WEEE Directive : At the end of their useful life the packaging and product should be disposed of by a suitable recycling centre. Do not dispose of with normal household waste. Do not burn. Manufactured for and on behalf of the Environmental and Combustion Controls Division of Honeywell Technologies Sàrl, Ecublens, Route du Bois 37,Switzerland by its Authorized Representative, Trend Control Systems Limited. Trend Control Systems Limited reserves the right to revise this publication from time to time and make changes to the content hereof without obligation to notify any person of such revisions or changes. Trend Control Systems Limited P.O. Box 34, Horsham, West Sussex, RH12 2YF, UK. Tel:+44 (0)1403 21888 Fax:+44 (0)1403 241608 www.trend-controls.com Trend Control Systems USA 6670 185th Avenue NE, Redmond, Washington 98052, USA. Tel: (425)897-3900, Fax: (425)869-8445 www.trend-controls.com 4 T/PC PRT Contact Temperature Sensor Installation Instructions TG100508A Issue 4/B 13/02/07
© Copyright 2026 Paperzz