N2XCH-FE 180/E 30 security cable, halogen-free, 0,6/1kV, with improved fire characteristics Technical data Cable structure Properties Ⴠ Halogen-free security cable with improved characteristics in the case of fire to DINVDE0266 Ⴠ Insulation integrity 180 minutes to DINVDE0472 part814 Ⴠ Functionality 30 minutes to DINVDE4102 part12 Ⴠ Temperature range -30 °C to +70 °C Ⴠ Permissible operating temperature at conductor +90 °C Ⴠ Nominal voltage U0/U 0,6/1 kV Ⴠ Test voltage 4000 V Ⴠ Minimum bending radius approx. 15x cable ø Ⴠ Radiation resistance up to 200x106 cJ/kg (up to 200 Mrad) Ⴠ Caloric load values see Technical Informations Tests Ⴠ Flame test to VDE 0482 part 266-2, BS 4066 part 3/ DIN EN 50266-2/ IEC 60332-3 (equivalent DIN VDE 0472 part 804 test method C) Ⴠ Corrosiveness of combustion gases according to VDE 0482 part 267/ DIN EN 50267-2-2/ IEC 60754-2 (equivalent DIN VDE 0472 part 813) Ⴠ Halogen-free according to VDE 0482 part 267/ DIN EN 50267-2-1/ IEC 60754-1 (equivalent DIN VDE 0472 part 815) Ⴠ Smoke density according to VDE 0482 part 1034-1+2/ IEC 61034-1+2/ DIN EN 61034-1+2/ BS 7622 part 1+2 (equivalent DIN VDE 0472 part 816) Ⴠ Insulation integrity under flame propagation to VDE 0472 part 814 ฬ IEC 60331 Funktionserhalt von Kabelanlagen nach DIN 4102 part 12 (30 min) Ⴠ Bare copper conductor, solid or stranded, to DINVDE0295 cl.1 or cl.2, BS6360 cl.1 or2, IEC60228 cl.1 or 2, HD383 Ⴠ Core with double insulation: Flame retardant MICA-tape over conductor Core insulation with cross-linked polyethylene, compound type 2XI1 to DINVDE0276 part604 Ⴠ Cores colour coding to DINVDE0293-308 and 0276 part604 Ⴠ Cores stranded in layers Ⴠ Overall core covering, halogen-free filling compound, pressed Ⴠ Concentric conductor of Cu-bare wires with helix of copper tape Ⴠ Outer jacket of thermoplastic halogen-free polyolefine, compound type HM4 to DINVDE0276 part604, flame retardant, colour orange Ⴠ LS0H = Low Smoke Zero Halogen-free. Ⴠ Halogen-free; no evolution of corrosive and toxic gases Ⴠ Flame retardant Ⴠ Hardly flammable Ⴠ Self-extinguished and fire resistant Ⴠ No flame propagation, therefore security from fire Ⴠ Low smoke density, no darkening of emergency exits without hindering the fire extinguishing works Ⴠ Toxicological harmless Ⴠ No self-ignition Ⴠ Maintenance of functionality during the increased current load Ⴠ FE180: Insulation integrity for 180 minutes. Tests to DINVDE0472 part814 IEC60331. Insulation integrity under direct flame propagation for the test period of 180minutes. Ⴠ E 30: Functionality of electrical cable systems for minimum 30minutes. Test method to DIN4102 part12. This fulfils the demands of technical guide lines for fire protection (supplement1 to DINVDE0108 part1). The functionality for 30minutes assures when persons and animals are to be saved from a burning building. 30minutes secures the functional performance of the fire warning and alarm systems, safety and spare lighting, passenger lifts with evacuation circuits, except the cables which are installed within the ladder shafts and engine rooms. Note Ⴠ rm = round conductor, multiple-wire; re = round conductor, single-wire. Ⴠ AWG sizes are approximate equivalent values. The actual cross-section is in mm². Application Everywhere, where in case of fire human life and material assets are to be protected and safety conciousness take a special significance, e.g. in industrial complexes, power stations, communal establishment, hotels, airports, underground railway networks, hospitals and outpatients clinic (DINVDE0107), department stores, data processing centres, theaters, cinemas, in multi-storey buildings, public gatherings, schools etc. (DINVDE0108), mining works, offshore plants, leading centres, traffic communication, emergency power supply and alarm systems. Suitable for fixed installation in dry and moist rooms, in, above, on and beneath plaster as well as in masonary walls and in concrete. These cables are suitable for outdoor applications and in underground by using in conduits or tubes. Additionally valid also DINVDE0298 part1 and 2. For the installation in conduit all precautions must be taken that no accumulation of water can occur in the pipes. = The product is conformed with the EC Low-Voltage Directive 2006/95/EG. Part no. 52098 52099 52100 No.cores x cross-sec. mm² 2x1,5 / 1,5 re 2x2,5 / 2,5 re 2x4 / 4 re Outer Ø approx. mm 13,0 14,0 15,0 Cop. weight kg/km 52,0 80,0 123,0 Weight approx. kg/km 200,0 250,0 310,0 AWG-No. 16 14 12 Part no. 52101 52102 52103 No.cores x cross-sec. mm² 2x6 / 6 re 2x10 / 10 re 3x1,5 / 1,5 re Outer Ø approx. mm 16,0 17,5 13,0 Cop. weight kg/km 182,0 312,0 66,0 Weight approx. kg/km 400,0 570,0 220,0 AWG-No. 10 8 16 Continuation Ⴇ Q 33 N2XCH-FE 180/E 30 security cable, halogen-free, 0,6/1kV, with improved fire characteristics Part no. 52104 52105 52106 52107 52108 52109 52110 52111 52112 52113 52114 52115 52116 52117 52118 52119 No.cores x cross-sec. mm² 3x2,5 / 2,5 re 3x4 / 4 re 3x6 / 6 re 3x10 / 10 re 3x16 / 16 re 3x25 / 16 rm 3x35 / 16 rm 3x50 / 25 rm 3x70 / 35 rm 3x95 / 50 rm 3x120 / 70 rm 3x150 / 70 rm 3x185 / 95 rm 3x240 / 120 rm 4x1,5 / 1,5 re 4x2,5 / 2,5 re Outer Ø approx. mm 14,0 15,5 16,5 18,5 21,0 25,5 29,0 31,5 36,5 40,0 46,0 50,5 55,0 61,5 15,0 16,0 Cop. weight kg/km 104,0 161,0 240,0 408,0 643,0 902,0 1190,0 1723,0 2410,0 3296,0 4236,0 5100,0 6383,0 8242,0 81,0 128,0 Weight approx. kg/km 270,0 360,0 470,0 680,0 960,0 1390,0 1720,0 2320,0 3260,0 4310,0 5520,0 6620,0 8180,0 10620,0 260,0 310,0 AWG-No. 14 12 10 8 6 4 2 1 2/0 3/0 4/0 300 kcmil 350 kcmil 500 kcmil 16 14 Part no. 52120 52121 52122 52123 52124 52125 52126 52127 52128 52129 52130 52131 52132 52133 52134 No.cores x cross-sec. mm² 4x4 / 4 re 4x6 / 6 re 4x10 / 10 re 4x16 / 16 re 4x25 / 16 rm 4x35 / 16 rm 4x50 / 25 rm 4x70 / 35 rm 4x95 / 50 rm 4x120 / 70 rm 4x150 / 70 rm 4x185 / 95 rm 4x240 / 120 rm 7x1,5 / 2,5 re 30x1,5 / 6 re Outer Ø approx. mm 17,0 18,0 20,0 22,5 28,0 30,5 32,0 39,5 43,5 49,5 55,5 60,0 68,0 16,5 29,0 Cop. weight kg/km 200,0 297,0 504,0 796,0 1142,0 1526,0 2203,0 3082,0 4208,0 5388,0 6558,0 8159,0 10546,0 133,0 499,0 Weight approx. kg/km 420,0 540,0 800,0 1150,0 1670,0 2160,0 2860,0 3980,0 5300,0 6740,0 8210,0 10200,0 12900,0 360,0 1070,0 AWG-No. 12 10 8 6 4 2 1 2/0 3/0 4/0 300 kcmil 350 kcmil 500 kcmil 16 16 Dimensions and specifications may be changed without prior notice. (RQ02) Q Q 34
© Copyright 2026 Paperzz