8 CM Series | Damper Actuator 2 Nm / 5 Nm Modulating Control PRODUCT FEATURES • Torque 2 Nm / 5 Nm • Damper size 0.4 m2 / 1.0 m2 • Power Supply AC/DC 24 V • Control Modulating DC 0(2)...10 V • Shaft dimensions - Ø 6 to 15 mm round / 5 to 10.5 mm square • Minimum shaft length 40 mm • Selectable direction of rotation • Adjustable angle of rotation • Actuator with 1000 mm cable connection • Customer version on request MODEL SELECTION TABLE Torque Running Time Power Supply Auxiliary Switch Model / Type 2 Nm 60...90 sec AC/DC 24 V ± 10% No 02CM - 24 5 Nm 70...100 sec AC/DC 24 V ± 10% No 05CM - 24 9 CM Series | Damper Actuator 2 Nm / 5 Nm Modulating Control 93 23 59 30 1000 CW 115 CCW TECHNICAL SPECIFICATION 02 / 05CM. Torque 2 Nm / 5 Nm Damper Size 0.4 m2 / 1.0 m2 Shaft dimensions Ø 6 to 15 mm round / 5 to 12 mm square Power Supply AC/DC 24 V ± 10% Frequency 50 - 60 Hz Control Signal (Input) DC 0(2)...10 V Position Signal (Output) DC 0...10 V Power Consumption - Operating 2.0 W - End Position 2.0 W For Wire Sizing 4.0 VA Protection Class III Angle of Rotation 0°...90° (95° mechanical) Angle of Limiting 0°...90° (max. 0°...30° / 60°...90°) Weight < 0.7 Kg Life Cycle 60,000 rotation Sound Level 40 dB (A) IP Protection IP54 (dust protected & protected against splash water) Operating Temperature -20o...+50o as per IEC 721-3-3 Non-Operating Temperature -30°...+60° C / IEC 721-3-2 Ambient Humidity 5%...95% rH non condensing / EN 60730-1 Maintenance Maintenance free Mode of Operation Type I / EN 60730-1 EMC CE according to 89 / 336 / EEC III 65 10 CM Series | Damper Actuator 2 Nm / 5 Nm Modulating Control Changing Direction of Rotation 02/05 CM Wiring Diagram 02/05 CM Power Supply AC/DC 24 V black red 1 CW Factory-set CW! M M yellow green 2 AC 24 V ± 10% DC 24 V ±10% 5 6 Y U CW The direction of rota- tion can be changed by pushing the CW/ CCW switch on the actuator’s housing. CCW DC 0(2)...10 V DC 0...10 V Adjustment of Control Signal 02/05 CM JP PCB Control Signal 5 Input Resistance Factory-set DC 0...10 V Ri 100 kOhm Control Signal 5 Input Resistance On request DC 2...10 V Ri 500 Ohm JP JP Wiring Diagram 02/05 CM Parallel Connection Remark 1 red 5 M black 1 yellow green 2 red 6 yellow green 2 5 Y1 AC 24 V ± 10% DC 24 V ±10% 6 Master M black Slave When 02/05 CM actuators operate in parallel, the output signal U = DC 0...10 V (terminal 6) of the master actuator must be con- nected to terminal 5 of the next slave actuator. DC 0(2).... 10 V max The power consumption must be observed. 11 CM Series | Damper Actuator 2 Nm / 5 Nm Modulating Control Wiring Diagram 02/05 CM NPG-1 Position Transmitter AC/DC 24 V Releasing the Adapter 02/05 CM Releasing the adapter is not required and not necessary. black 1 NPG-1 M red 3 2 U U =DC 0(2)...10 V black 1 red 2 yellow 5 NACM 1.2... M AC 24 V ± 10% DC 24 V ±10% Limiting Angle of Rotation NACA 1/2... (S1) Adjustment of Mechanical Limiter 1. Loosen screw of mechanical limiter 2. Move limiter to appropriate position * 3. Tighten screw * Working range of 90o can be reduced up to 30o from each end position. 0°...90° 0°...90° (30o) This actuator includes electrical and electronic components and may not be disposed as household garbage. Please consider the local valid legislation. AC / DC 24 V: Connect via safety isolating transformer. AC 230 V: To isolate from the main power supply, the system must incorporate a device which disconnects the phase conductor (with at least a 3 mm contact gap). (30o)
© Copyright 2025 Paperzz