Infinity Segments

INSTALLATION INSTRUCTIONS
CP5002, CP5004, CP5006
Model:
INFINITY PERFORMANCE
Fixture Family:
Document Description: Installation Instructions for
INFINITY SEGMENTS
1717 West Civic Drive Milwaukee, WI 53209
414-354-6600
Design Modification Rights Reserved
© Visa Lighting
REF. CHART
C
F
A
E
D
Drawing: 760763XX
B
I
A
Rev:
H
CEILING MATERIAL
G
Sheet: 1 of 3
K
J
1) Depending on the length of the screws supplied with the junction box (by others)
you may need to use the longer screws provided. Fasten Cast Swivel Plate (A) to
junction box.
3) While supporting far end of fixture, lift other fixture end and swivel ball (D) through slot
(E) in the cast swivel plate and drop into center hub, aligning anti-rotation groove in
swivel ball with tab in the cast swivel plate.
4) Fasten retainer (F) to cast swivel plate with screws provided.
5) Lift far end of fixture and push 1/16 stainless steel cable (G) into griplock assembly (C).
Level fixture by adjusting griplock assembly and other griplock postions.
6) Make all wire connections per local and national codes.
7) Lift canopy (H) in place and secure with screws (I) provided.
8) Position non-supporting cable trim assembly (J) and slide o-ring (K) up to hold in place.
!
When using electrical equipment, basic safety precautions should always be followed, including the following:
• Read all instructions carefully before installing and save for future use.
• Make sure all connections are in accordance with the National Electrical Code and local regulations.
• To avoid possible electric shock, be sure the power supply is turned off before servicing or installing the fixture
• Service should be performed by qualified personnel.
• These instructions may not cover all details or variations. If additional information is needed, please contact Visa Lighting.
Date Drawn:
2) For drywall ceilings drill clearance hole for toggle bolt (B) per chart on center from center
of junction box. For Suspended ceilings install 512 HD Caddy Clip (by others) at location
of per chart on center from center of junction box and supply a 1/4-20 all thread drop
through ceiling. Install Griplock assembly (C) keeping trimwasher to the ceiling side and
tighten.
MTC
Eng:
CABLE ADJUSTERS
INSTALLATION INSTRUCTIONS
CP5002, CP5004, CP5006
Model:
INFINITY PERFORMANCE
Fixture Family:
Document Description: Installation Instructions for
INFINITY SEGMENTS
1717 West Civic Drive Milwaukee, WI 53209
414-354-6600
Design Modification Rights Reserved
© Visa Lighting
Drawing: 760763XX
A
Rev:
Sheet: 2 of 3
C
A
MODEL:
A
B
C
CP5002
12 3/4"
62"
31"
Date Drawn:
POWER IN
AIRCRAFT
CABLE
CP5004
6 7/8"
70"
35"
CP5006
8 3/4"
88 1/4"
44 1/8"
MOUNTING LOCATIONS
!
When using electrical equipment, basic safety precautions should always be followed, including the following:
• Read all instructions carefully installing and save for future use.
• Make sure all connections are in accordance with the National Electrical Code and local regulations.
• To avoid possible electric shock, be sure the power supply is turned off before servicing or installing the fixture
• Service should be performed by qualified personnel.
• These instructions may not cover all details or variations. If additional information is needed, please contact Visa Lighting.
MTC
Eng:
B
INSTALLATION INSTRUCTIONS
CP5002, CP5004, CP5006
Model:
INFINITY PERFORMANCE
Fixture Family:
Document Description: Installation Instructions for
INFINITY SEGMENTS
1717 West Civic Drive Milwaukee, WI 53209
414-354-6600
Design Modification Rights Reserved
© Visa Lighting
MOVING THE POWER IN
(CURVES & STRAIGHTS)
2. Unscrew splice box cover. Disconnect power and ground
wires and cap off according to electrical standard practice.
(Note: The orange quick disconnect will remain in place, and
serves as a power disconnect when PAC is connected to either
end.)
PAC
Drawing: 760763XX
1. Remove glass lense(s) by unscrewing the lens clips and set
aside.
3. Unscrew lamplate to access Power Art Cable (PAC) connection.
A
4. Detach aircaft cable from apposite end, and replace with PAC.
Rev:
3. Remove 1/4-20 nut which secures PAC.
5. If necessary remove PAC from the PAC plate by removing
the #8 screw. Attach the plate to the 1/4-20 stud on the
other end, then put the wires through the lamplate and reattach
to the PAC plate.
PAC PLATE
7. Reattach lamplate, splice box covers, glass lense(s), and
aircraft cable at opposite end.
Sheet: 3 of 3
6. Make all electrical connections within the splice box, which
already contains another set of lead wires.
SCREW #8
1/4-20 NUT
LAMPLATE
1/4-20 STUD
HOUSING
!
When using electrical equipment, basic safety precautions should always be followed, including the following:
• Read all instructions carefully before installing and save for future use.
• Make sure all connections are in accordance with the National Electrical Code and local regulations.
• To avoid possible electric shock, be sure the power supply is turned off before servicing or installing the fixture
• Service should be performed by qualified personnel.
• These instructions may not cover all details or variations. If additional information is needed, please contact Visa Lighting.
Date Drawn:
SPLICE BOX
COVER
MTC
Eng:
8-32 SCREW