HCT.CO.,LTD 105-1, Jangamri Majangmyeon Ichensi Gyeonggido, 467-811. Republic of Korea T. 82-31-6456365 Email. [email protected] www.hct.co.kr www.particle-science.com HCT - Technology Changing How We Live PC-3106P (Optical Particle Counter) PC-3106P is an instrument which can measure the particles suspended in the air above 0.3μm in diameter. Its sampling flow rate is 1 CFM ( 28.3L/min ). It provides several analog input (4~20mA) terminals for external sensor or probe – air velocity, temperature & humidity, differential pressure, etc. PC-3106P complies with the requirements of ISO 21501-4 or JIS B9921 and is calibrated using a condensation particle counter with NIST traceable PSL. PC-3106P provides measurement result reports for ISO 14644-1 and FS209E via the onboard thermal printer. Measurement data can be stored in the internal memory up to 30,000 records. PC-3106P can either be used as a stand-alone particle counter or as a part of in the Facility Monitoring System (FMS). Feature and Benefits • Up to 6 channels of simultaneous particle count data • Data storage 30,000 samples records • 4 to 20 mA input (T/H, Velocity, Diff. Pressure) • Touch screen operation • Reports for ISO14644-1, FS209E Applications • Cleanroom Monitoring • Facility Monitoring • Hospital Surgical Suites • Pharmaceutical • Electronics (Semiconductor, Flat Panel, LED,Hard Disk) Monitoring SPECIFICATIONS Particle channel sizes 0.3, 0.5, 1.0, 5.0, 10, 25 ㎛ or 0.3, 0.5, 1.0, 3.0, 5.0, 10 ㎛ , 6ch Counting efficiency 50% at 0.3 ㎛, 100% for particles > 0.45 ㎛ (Meets ISO and JIS Standards) Concentration limit < 1,000,000 / ft3 at 5% coincidence loss Light source Laser diode Zero count < 1 count per 5 minutes (per ISO21501-4 and JIS B9921) Flowrate 28.3 L/min (1.0 CFM) ± 5% accuracy (meets ISO 21501-4 and JIS B9921) Sampling time 1 sec ~ 1 hrs Data storage 30,000 samples records (internal memory) Communication Ethernet, USB Serial, RS 485 Printer Thermal Printer Vacuum source Internal pump Battery Li –Ion battery Battery runtime 3 hours (2 Battery) Dimension (LWH) 30 x 24 x 23 cm(11.8 x 9.45 x 9.05 in) Weight 5.2 kg(11.46 lbs) Power 24V / 4.0 Adapter 100 ~240VAC, 50/60 Hz Parts Number 6C06008 6C06007 6P02016 7004022 6P02030 8007141 9005011 1401017 Power Cable USB Download cable, type A to B & LAN cable Li-Ion battery Purge Filter Assy Adaptor Software program CD Printer paper Isokinetic probe & Cap HCT Instruments INC. 1229 38th Ave N MS – 161, Myrtle Beach, So Carolina 29577 Tel: 970-481-5721, Email. [email protected] www.hctinstruments.com HCT - Technology Changing How We Live HCT.CO.,LTD 105-1, Jangamri Majangmyeon Ichensi Gyeonggido, 467-811. Republic of Korea T. 82-31-6456365 Email. [email protected] www.hct.co.kr www.particle-science.com HPS-0405W (Hybrid Particle Sensor) HPS is a new product that combines the functions of the existing Optical Particle Counter and Virtual Impactor all into one package. It can count the number of particles per particle size and also sample the particles at the same time. Feature and Benefits Real Time Insitu Particle Counting and Sizing With Particle Capture For Off Line Analysis • Four Channels of Simultaneous Particle Count Data • Ease to install • Easily installed in the Process Equipment Eliminating Transport Tubing Losses • Ag Sample Collecting Plate for Off line Particle analysis • Meets or Exceeds current JIS (JIS : Japanese Industrial Standards) Sensor inside Applications • Clean Room and Facility Monitoring • Particle Trend Analysis • Indoor Air Quality (IAQ) Analysis • Real Time InSitu Particle Monitoring in the Process Equipment. SPECIFICATION Size range Particle channel sizes Counting efficiency Flow rate Max. concentration Sampling time Light source Zero count level Vacuum requirement 0.5 ~ 10.0 ㎛ 0.5, 1.0, 2.0, 5.0㎛ (4ch) or 0.5, 1.0, 5.0, 10.0 (4ch) 50 % at 0.5 ㎛ , 100 % > 1.0 ㎛ 28.3 L/min (1.0 CFM) ) ± 5% accuracy 1,000,000 particles/CFM @ 0.5 um 1 sec ~ 60 sec Laser Diode (35 mW) < 1/sec @ 5 min. External Vacuum Pump ( < 160 mmHg ) Communication Enclosure Surface of sampling plate Dimension (LWH) Weight Power (main) 90 Kpa ± 10% (Vacuum) Ethernet Steel Ag coated 7 x 14 × 12.5 cm (2.8 x 5.5 x 5 in) 0.89 kg (1.96 lbs) 100 ~ 230 VAC, 50 ~ 65 HZ (Adapter) * System components excluded : Stand Parts Number • 1001027 • 1003004 • 1003003 • 1003002 5V, 4A ▼ Before Sampling Main inlet Inlet tube connector Stand (for bottom) Bracket (for wall) ▼ HPS Monitoring Software 300 1.0 mm 2.0 mm 5.0 mm 10.0 mm ▼ After Sampling Particle Counts, #.sec 250 200 150 100 50 0 0 100 200 300 400 500 600 700 800 900 1000 Time, sec HCT Instruments INC. PO Box 3532 Myrtle Beach, SC 29578 T. 843-808-9224, Email. [email protected] www.hctinstruments.com HCT - Technology Changing How We Live HCT.CO.,LTD 105-1, Jangamri Majangmyeon Ichensi Gyeonggido, 467-811. Republic of Korea T. 82-31-6456365 Email. [email protected] www.hct.co.kr www.particle-science.com CAS-01 (Clean Air Supply) AG-01 (Aerosol Atomizer) Aerosol generation is very important and necessary in the field of aerosol science. AG-01 is a nebulizer type aerosol generator. Aerosol jets generated by compressed air throughout the critical orifice collide with the wall inside AG-01. Small droplets (including particle droplets) divided by impaction is exhausted outside AG-01. Application: SPECIFICATIONS • Filter Media Test • Particle generation in wind tunnel • Particle deposition in wafer deposition system SPECIFICATIONS • • • • • • • Air Flow Rate : 4.5 L/min at 2.5 kg/cm3 Particle Concentration : < 106 particles/cm3 Geometric Standard Deviation : 1.3 ~2.0 Pressure Source : Air compressor Number of Jets : 1 Dimensions (height) : 130 mm (5.12 in) Weight : 0.5 kg (1.1 lbs) • Part Number § 2601003 § 2601004 § 2601001 § 2601006 Clean Air Supply, CAS-01 can provide clean and dry compressed air for aerosol experiments. The Water & Oil trap removes large water & oil drops included in the compressed air. Compressed air is then dried in the desiccant dryer, then exhausted throughout the HEPA filter. . Maximum pressure : 10 kg/cm3 Flow rate : 50 LPM (Max.) Dimension (LWH): 450 x 240 x 400 mm (17.7 x 9.45 x 15.7 in) Weight : 10 kg (22.05 lb) • • • • • Part Number § 2501004 § 7004004 Oil trap HEPA Filter Orifice 0.3 mm Orifice 0.5 mm Lid (tempered glass) Lid (Quartz) XRC-05 (Soft X-Ray Charger) XRC-05 is a bipolar charger that uses soft X-ray instead of radioactive source such as Am241 (Americium-241), Kr85 (Krypton-85), Po210 (Polonium-210). It changes irregularly charged particles to equilibrium charged state. Particles introduced into XRC-05 is collided with ions (+) or electrons (-) generated by soft X-ray radiation. Ions or electrons being attached onto the particle surfaces, neutralizing the particles. XRC-05 does not generate Ozone due to its air ionization effect. DD-01 (Diffusion Dryer) DD-01 removes water vapors contained in the aerosol and dries-off water on the surface of the droplet. The Water & Oil trap mounted at the inlet of DD-01 removes large water & oil drops. Aerosols are dried by the diffusion of water vapor in the desiccant dryer filled with molecular sieve or silica gel. SPECIFICATIONS • • • • • • • • • • Ion Generation Method: Soft X-ray Source: Soft X-ray tube Power Consumptions: 7.2W Cooling Method: Natural cooling Weight: 1.11 kg /2.45 (lb) Input Power: AC 100~240V, 50/60Hz (Adaptor Input) DC 12V, 3.33A Life Time: 1 year Indicating: Ion generation indicating Dimension (LWH):273 X 72 X191 mm (10.8 x 2.8 x 7.5 in) • Part Number § 2302002 § 2302004 DC 12V Adapter & power cord Safety Key SPECIFICATIONS • • • • Flow rate : 0 ~ 5 L/min Maximum pressure : 420kPa Relative humidity ; 20 % when incoming R.H. is 60 % Dimension (LWH): 570 x 160 x 210 mm ( 224.4 x 6.3 x 82.7 in) • Part Number § 2401001 § 2401002 § 2401003 § 2401004 § 2401005 § 9005009 Lid Stand Water trap Outer Cylinder Inner Diffusion Screen Silica gel (Optional) HCT Instruments INC. 1229 38th Ave N MS – 161, Myrtle Beach, So Carolina 29577 Tel: 970-481-5721, Email. [email protected] www.hctinstruments.com HCT - Technology Changing How We Live HCT.CO.,LTD 105-1, Jangamri Majangmyeon Ichensi Gyeonggido, 467-811. Republic of Korea T. 82-31-6456365 Email. [email protected] www.hct.co.kr www.particle-science.com AS-03 (Air-Sampler) VI-104 (4-Stage Impactor) Due to strict environmental rules, it is highly necessary to sample aerosols or gas-phase materials. Especially, the product protection against fine particles or gas-phase materials is essential in semiconductor, LCD or any precision manufacturing fields. The Model AS-03 is the instrument to sample these gas-phase materials. According to environmental regulations, it is needed to analyze airborne particles to identify their components or composition. Such particles should be collected to be analyzed. VI-104 is the instrument to be used to collect them. Application: Portable sampler Maximum of 12 hours (Using a built-in battery for operating with 2 LPM) User-friendliness • The touch screen enables a convenient control. • The sampling start or shutdown can be scheduled using the built-in timer. • Sampling can be done by setting either the sampling time or the total flow rate. • Aerosol Research : Particle sampling, collection, generation and transport • Particle analysis in clean-room and associated controlled environments • Indoor and outdoor air quality research • Bio-aerosol research Optimization for clean-room environments A built-in HEPA filter is used to prevent contamination by a pump, optimal for sampling in a clean-room Accuracy of flow rates • The differential pressure sensor assures a higher accuracy for the air sampler. • Guarantee of the accuracy of flow rates (±5% full scale) throughout flow rate correction. Application: • Sampling in hospital or bioengineering research center • Sampling in clean-room • Sampling in factories or industrial field SPECIFICATIONS • Sampling flow rate : 20 L/min • Particle Cut-off Diameter: 1.0, 2.5, 5.0 and 10 μm • Front panel display : Touch screen LCD Panel (Set-up reserved time / operation time / Display present time) • Dimension (LWH): Controller : 320 x 235 x 240 mm (12.6 x 9.3 x 9.5 in) Impactor : Ø78 x 265 H mm (Ø78 x 10.4 in) • Weight : 6.5 kg (14.3lb) • Power : 100 ~ 240 VAC, 50/60 Hz • Part Number § 6C06001 Power Cable § 7004004 HEPA Filter DMA-20/05 (Differential Mobility Analyzer) SPECIFICATIONS SPECIFICATIONS • • • • • • • • • • Sampling flow rate : 1~3L/min Flow rate accuracy : ± 5 % of full scale Gas temperature range : 10~50°C Gas pressure range : 1 ± 0.2 ATM Operating hours : 12 hrs @ 2 L/min (in full charging battery) Battery charging time : 4~5 hrs LCD display : Graphic color LCD (400 x 240 pixel) Dimensions (LWH) : 160 x 190 x 190 mm (7.5 x 6.3 x 7.5 in) Impinger : 240 mm x Ø 45 (9.5 lb x Ø 45) Weight : 2.6 kg (5.7 lb) Power : 100~240 VAC, 50/60 Hz • Part Number § 6C06001 § 1901001 • Particle Size Range : - DMA-05 : 2 ~ 160 nm - DMA-20 : 7 ~ 830 nm • Maximum input concentration : 107 particles/cm3 @ 10 nm • Aerosol pressure range : 1 ± 0.1 ATM • Flow rate : - Aerosol : 0.1~1.5 L/min - Sheath Air : 1 ~ 15 L./min - By pass : None • Voltage : 10 ~ 10,000 VDC • Dimensions : DMA-05 : 210 x 36 mm (8.3 x 1.4 in) DMA-20 : 420 x 76 mm (16.5 x 3.0 in) • Weight : DMA-05 : 2 kg (4.41 lb) / DMA-20 : 7 kg (15.43lb) Application: • Aerosol research : particle generation, nucleation, condensation, coagulation and transport • Particle charging and electrical mobility studies • Filter media test • Mono-disperse particle generation for instrument calibration Power Cable Impinger HCT Instruments INC. 1229 38th Ave N MS – 161, Myrtle Beach, So Carolina 29577 Tel: 970-481-5721, Email. [email protected] www.hctinstruments.com HCT.CO.,LTD 105-1, Jangamri Majangmyeon Ichensi Gyeonggido, 467-811. Republic of Korea T. 82-31-6456365 Email. [email protected] www.hct.co.kr www.particle-science.com HCT - Technology Changing How We Live WCPC-1003S(Water-based Condensation Particle Counter) A new approached is applied using particle condensation technique. When a particle is place in a super-saturated vapor, the super-saturated vapor molecules will start condense onto the particle. The particle with condensed vapor will continuously grow and become a large droplet. This large size droplet can easily be detected by optical electronic system. Benefits and Applications § Single Particle Counting with real-time for accurate measurement (0 ~ 10,000 particles/ cm3) § With water as the working fluid and HEPA-filtering of the exhaust – use the clean room environment § With High Pressure Diffuser(HPD-75), Possible to Monitoring in high pressure gas lines Feature § 10 nm Detection Limit § 2.83 L/min of aerosol Flow rate § Built-in Color Touch Screen Display (7“) § Adopted in Internal Thermal Printer § Contaminant particle detection in cleanroom and high purity gas systems § Ethernet, USB Serial Communication SPECIFICATIONS Particle Size Range : Min. Detectable Particle(D50): 10 nm, verified with DMA-classified Particle Concentration Range : Single Particle Counting: 0 to 10,000 particles/ ㎤ Particle Concentration and Accuracy : ±10 % at 10,000 particles/㎤ Flow rate : 2.83 ± 0.28 L/min Response Time : ~ 0.8 sec., (95% Response to Concentration Step Change) False Background Counts : ~5x10-6 /㎤, 12 hrs average Aerosol Medium : Inert Gas for Air, N2, Ar Environmental Operating Conditions : Ambient Temp. & Humidity: 10 to 35℃ and 0 to 90% RH, Non condensing The efficiency curve Inlet Pressure : 75 to 110 kPa Working Fluid : Distilled Water only 100 90 Vacuum : Internal Vacuum Pump 80 Outputs : USB Serial, Ethernet, SD Card, Internal Thermal Printer 70 Digital Display: 7” Color touch screen Power : Adapter for 24 VDC, 6.0A Communication: USB Efficiency , % Water Supply System : External 1 Liter Bottle used (5 days of continuous operation) 60 50 40 Dimensions (LWH): 310 x 200 x 270 mm (12.2 x 7.9 x 10.6 in) 30 Weight: 9.4 kg (20.7 lb) 20 Parts Number • • • • • • • 10 6C06001 7004014 7008001 9005011 6C06007 9003005 2602022 Power Cable CPC Extra Filter Drain Bottle / Fill Bottle Printer paper USB Download cable, type A to B & LAN cable Sampling Tube (1 m) Monitoring software Program 0 1 10 100 Particle diameter , nm HCT Instruments INC. 1229 38th Ave N MS – 161, Myrtle Beach, So Carolina 29577 Tel: 970-481-5721, Email. [email protected] www.hctinstruments.com HCT - Technology Changing How We Live HCT.CO.,LTD 105-1, Jangamri Majangmyeon Ichensi Gyeonggido, 467-811. Republic of Korea T. 82-31-6456365 Email. [email protected] www.hct.co.kr www.particle-science.com DI-120 (Aerosol Dilutor) HCT Model DI-120 reduces particle concentrations of high-concentration aerosols. Feature & Benefits • Highly repeatable performance • Dual pressure gauges (indicate correct operation or signal need for maintenance) • Require NO power or NO compressed gas. • Simple maintenance • Trouble-free cleaning. DI-120 test using the 0.3mm PSL 140 SPECIFICATIONS 1.2 LPM 1.5 LPM 120 100 • Dilution ratio : 1:100 • Dimensions (LWH) : 85 x 420 x 107 mm ( 3.35 x 16.54 x 4.21 in) • Weight : 9.82 kg ( 21.65 lbs) Dilution ratio • Sample flow : 1 LPM (1.2 / 1.5 optional) 80 60 40 20 0 0 5 10 15 20 25 30 Clean Air Gauge (mmH2O) HPD-75 (High Pressure Diffuser) Connecting pressurized air or gas to a particle counter is able to damage the instrument. HPD-75 can reduce the pressure of these gases and allow the particle counter’s flow metering system to function as designed. No external flow meters needed SPECIFICATIONS • Air Flow Rate: 0.1 CFM • Material: Stainless steel body with orifice, exhaust filter • Pressure: 35 ~ 75 psi for 0.1 CFM • Inlet fitting: ¼” VCR Male Connector • Exhaust fitting: ¼” tube type • Sample gas: Dry, inert, non-toxic, non-flammable gases (CDA, Nitrogen, Argon) • Dimensions (HWD): 182 x 155 x 77 mm (7.17 x 6.10 x 3.03 in) • Weight : 782 g (1.72 lbs) • Included : Mounting brackets and exhaust tube (1 m) HCT Instruments INC. PO Box 3532 Myrtle Beach, SC 29578 T. 843-808-9224, Email. [email protected] www.hctinstruments.com HCT - Technology Changing How We Live HCT.CO.,LTD 105-1, Jangamri Majangmyeon Ichensi Gyeonggido, 467-811. Republic of Korea T. 82-31-6456365 Email. [email protected] www.hct.co.kr www.particle-science.com EPS-n (Electrical Particle Sizer with XRC-05) EPS-n is an instrument which classifies a particle according to its electrical mobility. Electrical mobility of a particle is decided by fluid resistance for ce and electrostatic force and can be converted to an equivalent particle diameter. The biggest advantage of EPS-n is that Soft X ray is used as the neutralizer instead of radioactive sources. The Soft X ray charger is installed inside the EPS-n making it smaller and more portable than its previous models. The EPS-n is a rudimentary instrument that generates mono-disperse aerosols and measures particle size distributions with high durability and repe atability. HCT provides two type of DMA, depending on your preferred particle size range. Benefits and Applications Aerosol Generation System • Fundamentals of aerosol research • Monitoring outdoor and indoor air quality • Filter Media Test for filter efficiency • Particle formation or growth research • Use for standard calibration tool of particle counter SNPS • Fundamentals of aerosol research • Atmospheric environment research • Research on semiconductor fabrication and material synthesis SPECIFICATIONS Maximum particle concentration : 107 particles/ ㎤ Particle size range - Using DMA-20 : 7~ 830 nm - Using DMA-05 : 2 ~ 160 nm Flow rate : - Aerosol : 0.1 ~ 1.5 L/min - Sheath air : 1 ~ 15 L./min Aerosol temperature range : 10 ~ 35°C TDMA Test Aerosol pressure range : 1 ± 0.1 ATM Front panel display : 800 x 480 pixel 60000 Power : 100 ~ 240 VAC, 50/60 Hz, 1.0A Dp = 20.28 s = 1.07 Dimensions (LWH): 260x375x350 mm ( 14.8 x 10.2 x 17.8 in) Dp = 29.98 s = 1.06 50000 Dp = 50.92 s = 1.06 Dp = 80.79 s = 1.06 • 6C06001 Power Cable • 6C05061 High voltage Cable • 6C05063 BNC Cable • 1801013 Impactor • 1804000 DMA-05 (Optional) • 1801000 DMA-20 (Optional) dType/dLogDp Parts Number 40000 Dp = 101.33 s = 1.06 30000 20000 10000 0 10 100 Particle diameter(nm) HCT Instruments INC. 1229 38th Ave N MS – 161, Myrtle Beach, So Carolina 29577 Tel: 970-481-5721, Email. [email protected] www.hctinstruments.com HCT - Technology Changing How We Live HCT.CO.,LTD 105-1, Jangamri Majangmyeon Ichensi Gyeonggido, 467-811. Republic of Korea T. 82-31-6456365 Email. [email protected] www.hct.co.kr www.particle-science.com SNPS-n20 (Scanning Nano Particle Spectrometer with XRC-05) SNPS-n20 is an instrument which can measure aerosol particles in the range from 7 to 830 nm in high resolution. SNPS-n20 consists of CPC and EPS, and these two devices are connected through a tube with each other. Particles classified corresponding to its electrical mobility in the EPS are introduced into the CPC, and then the particles are measured by the optical system in the CPC after condensational growth. Measured data is transferred in real time to a computer using the Scanning Mobility Particle Spectrometer software. Raw data is converted to particle size distribution through the inversion algorithm. SNPS-n20 is suitable to measure airborne particle size distributions, so SNPS is highly recommended monitoring atmospheric aerosol in the Meteorology. SNPS can be also used for measuring the size distribution of test aerosols in Inhalation toxicology test system or filter media test system. Applications Benefits • Indoor/outdoor air quality research • Real-time nanoparticle size measurements : 75 sec (scan + retrace) • Occupational hygiene/workplace exposure monitoring • High resolution : 64 channels per decade • Filter Media Test for filter efficiency • Nano particle size up to submicron particle size : 7 nm ~830 nm • Inhalation toxicology • Meet ISO 15900 : 2009 • Fundamentals of aerosol research • No radioactive materials • Nanotechnology applications • Built-in data logging • Atmospheric environment research • Size distributions down to 10 nanometers SPECIFICATIONS Maximum particle concentration : 107 particles/ ㎤ Maximum particle size resolution : 64 channel Particle size range - Using DMA-20 : 7~ 830 nm - Using DMA-05 : 2 ~ 160 nm Flowrate : - Aerosol : 0.1 ~ 1.5 L/min - Sheath air : 1 ~ 15 L./min CPC Type : Water based CPC or N-Butyl CPC Aerosol temperature range : 10 ~ 35°C Aerosol pressure range : 1 ± 0.1 ATM Communication : RS-232 Power : 100 ~ 240 VAC, 50/60 Hz, 1.0A Parts Number • 6C06001 Power Cable • 6C05061 High voltage Cable • 6C05063 BNC Cable • 1801013 Impactor • 1804000 DMA-05 (Optional) • 1801000 DMA-20 (Optional) • 7004014 CPC Extra Filter • 7008001 Drain Bottle / Fill Bottle • 1702002 HCT SNPS Software program HCT Instruments INC. 1229 38th Ave N MS – 161, Myrtle Beach, So Carolina 29577 Tel: 970-481-5721, Email. [email protected] www.hctinstruments.com HCT - Technology Changing How We Live HCT.CO.,LTD 105-1, Jangamri Majangmyeon Ichensi Gyeonggido, 467-811. Republic of Korea T. 82-31-6456365 Email. [email protected] www.hct.co.kr www.particle-science.com HCT-3710 (Mask Tester) HCT has developed a mask tester ideal for respirator testing and perfect for complying with standards such as NIOSH and EN 143. The multi-jet atomizer in the HCT-3710 is capable of generating a large amount of aerosol(120mg or 200mg) that can be easily adjusted by changing the nozzle part having a different number of nozzles. Feature & Benefits • The dehumidifier in the HCT-3710 maintains a less than 60% relative humidity for the generated aerosol. • HCT-3710 also features the HCT Soft X-ray which acts as a neutralizer that does not need special authorization to be used. It offers high performance efficiency for respirator tests. • The flow rate for the test can be automatically adjusted. • The automatic flow control can maintain the set flow rate for the duration of the test period providing a highly reliable mask performance review. • An anti-vibration and soundproof chamber is provided with the HCT-3710 to be used during high flow pump operations. • The user can monitor the process in real time. Its dedicated software has a functional graph tool suitable for data analysis and was designed to process large amounts of data. • The test parameters can be adjusted by varying the level of Relative Humidity and amount of aerosol challenge. It can test various type of masks by changing mask adaptor. * Mask adaptor must be ordered separately. When you order this product, we provide a basic type of mask adaptor. HCT-3710 has been enhanced to insure your final products meet global standards. Complied with En 143, NIOSH 42 CFR part 84. Generate a large amount of aerosol. Easy to use – smart software No radioactive source Low maintenance ▲ Display Environment data ▲ Display Chart & Data Particle Generation Particle detection Particle type Detection rate Environment data Features Specifications Particle Generator Atomizer Particle measurement system Photometer Sampling Flow rate Bypass & 1.5 L/min Sampling particle Dynamic range 0 ~ 400 μg/s DOP Diameter (count median) 0.18 μm, ±0.2 μm DOP Mass 17 mg/min Display : Pressure, Temperature, Relative humidity, Flow rate DOP Standard deviation <1.7 Chamber On/Off Paraffin diameter (count median) 0.18 μm, ±0.2 μm Control start and stop Paraffin mass 17 mg/min Paraffin Standard deviation <1.7 NaCl diameter (count median) 0.085 μm, ±10 nm NaCl Mass 3.6 mg/min NaCl Standard deviation <1.86 Efficiency rate 30 ~ 99.999 % Neutralizer Soft X-ray charger Flow rate 0 ~ 120 L/min Differential pressure 0 ~ 620 Pa Temperature 10 ~ 50 ℃ Humidity 20 ~ 60 % Communication USB to Serial Power 100 ~ 240 VAC, Dimension 1400 * 800 * 1080 (mm) Weight 300 kg ▲ Main Display at Window Aerosol type : NaCl, DOP, Paraffin HCT Instruments INC. PO Box 3532 Myrtle Beach, SC 29578 T. 843-808-9224, Email. [email protected] www.hctinstruments.com
© Copyright 2025 Paperzz