explosive gas detector CH4 - H2 - C3H8 - CxHy ... Principles: CATALYTIC INFRARED Connection: 3 wires Output signal: Wheatstone bridge ATEX marking: II 2G Ex db IIC T6 - T4 II 2D Ex tb IIIC Tx °C THE BELGIAN PIONEER IN GAS DETECTION DALEMANS-FT-detDAX3F_I•LINE_EN To guarantee safety and performance, all gas detection installations must be calibrated and maintained regularly in accordance with the manufacturer’s instructions. DAX 3F MEASUREMENT PRINCIPLE CATALYTIC The detector sensing element is made up of two platinum filaments electrically heated to around 400°C. One of them (1) is covered with an active catalytic layer which heats up strongly in the presence of a combustible gas. Sensing head Stainless steel 1,4404 (AISI 316L) Sintered metal filter Stainless steel 1,4404 (AISI 316L) Junction box Aluminium Dimensions (LxWxH) / Weight 170 x 145 x 90 mm / 1400 g Output signal 3-wire mV (Wheatstone bridge) Response time (T90) < 30 s Type DAX 3F-CA DAX 3F-IR Measuring principles Catalytic Infrared Supply voltage * 1,925 - 2,025 V 3,2 - 5,0 V Consumption * 155 - 195 mA 75 - 85 mA Operating temperature -20 °C to +55 °C (T6 t° class) -20 °C to +50 °C Storage temperature -40 °C to +80 °C -20 °C to +50 °C Ambient humidity 20 - 90 % RH 0 - 95 % RH ± 3 % full scale < 60 % LEL ± 0,5 % full scale < 50 % LEL Accuracy ± 5 % full scale > 60 % LEL ± 1 % full scale > 50 % LEL Lifetime > 2 years > 5 years Cable cross section 1,5 - 2,5 mm2 (solid wires) Cable entry 1 x M20 / 6,1 - 11,7 mm (other sizes available) Refer to the installation instructions Max. cable length of the control unit Hazardous areas Zone 1 or 2 (gas). Zone 21 or 22 (dust) Casing ingress protection IP66 Equipment gas grouping IIC (methane, propane, ethylene, hydrogen, acetylene) Equipment dust grouping IIIC (conductive dust) Standards EN 60079-0 • EN 60079-1 • EN 60079-31 Approval (ATEX + IECEx) II 2G Ex db IIC T6 - T4 • II 2D Ex tb IIIC Tx °C Certificates FTZU 09 ATEX 0313X * Depends on type of cell used. GASES CONCERNED Measurement Density range L.E.L. Gas Formula (air=1) (% L.E.L.) (% vol.) DAX 3F-CA 0,90 0 – 100 2,30 Acetylene (CH)2 • 2,05 0 – 100 1,40 Butane C4H10 • 0 – 100 3,10 Ethylene oxide C2H6O 1,59 • Natural gas - 0,68 0 – 100 - • Hydrogen H2 0,07 0 – 100 4,00 • Isobutane (CH3)3CH 2,00 0 – 100 1,30 • Methane CH4 0,55 0 – 100 4,40 • Propane C3H8 1,56 0 – 100 1,70 • DAX 3F-IR • • • This temperature increase causes an increase in the resistance of the filament which is measured in the unit. The other filament (2), passive, serves as a thermal compensator. 1 2 GAS INFRARED The infrared cell functions according to the non-dispersive infrared (NDIR) principle. It is made up of a casing comprising: - a diffusion membrane (1), - a measurement chamber (2), - an IR radiation source (3), - an active sensor (4) and - a reference sensor (4’). The gas that reaches the measurement chamber absorbs - within a very precise range of wavelengths - a part of the radiation emitted by the IR source. The active sensor measures the remaining IR radiation and thereby determines the concentration of the gas present. The reference sensor measures the IR radiation within a range of wavelengths that is not influenced by the incoming gas. Its signal serves to compensate any variation in IR radiation which is not due to absorption caused by the targeted gas, such as a variation in temperature, humidity level, etc. This enables us to obtain an accurate and reliable measurement in all conditions. 3 2 • • Other gases upon request. 4 4’ 1 GAS rue Jules Mélotte 27 - B-4350 Remicourt Tel.: +32 (0)19 33 99 43 • Fax: +32 (0)19 33 99 44 • [email protected] www.dalemans.com The information contained in this documentation is non-contractual and subject to modifications. CHARACTERISTICS
© Copyright 2026 Paperzz