LED BARGRAPH WITH SINGLE OR DUAL STRIP LIGHT BGL144 (144 x 48 mm) • Process Input: mA, mV, V (Selectable) • Display: 40 leds strip light, 10 000 pts led display Red, Green, Yellow, Blue colors available • BGL144-1: Single strip light with display version • BGL144-2: Dual strip light with display version • BGL144/R: 2 alarms relays option • BGL144-L: Low cost version (without display) • BGL144 H: Horizontal mounting version BGL144 device is a digital bargraph. It permit, thanks to it’s strip lights to quickly appreciate the measure order of magnitude as well as it’s variance. It’s digital display permit if needed, a more accurate reading. FUNCTIONALITY: Setting: Inputs: Full device setting in front panel or via RS232 link with every terminal emulating system Example: HyperTerminal Windows The two input channels are independently configurable for voltage or direct current measures. - Current 0..4....20 mA, - Voltage on 3 ranges : 0….150mVdc , 0...20Vdc ,0….200Vdc (all scales can be carried out in ranges limits) Measures: - Physical unit range conversion (customizable front scale) - Square root extraction - Non linear scale (polyline) Front panel: - Measure visualization strip light; 40 points resolution (two display mode : dot or bar) - Over-current alarm threshold setting - 4 digits led alphanumerical display; 10 000 points resolution - Visualization of channel 1 or 2 setting in front panel - Displayed channel indication led - Alarm indication led - Three buttons keyboard for full device setting (input type, thresholds setting, communication, output) (locking available on RS232 link). Relays: 4 relay outputs maximum (2 for each channel) which can be used in alarm or regulation mode (input current loop breaking detection) Threshold, direction, hysteresis and delay individual setting for each relays (on & off delay) Analog output: General characteristics: - Slot-in enclosure (144mm x 48mm x 85mm HxLxD) - Snap-in fixing by means of plastic clamps - Wiring on plug in spring loaded terminals (wire gauge: 1mm² maxi) - Tropicalization varnish - IP20 Tightness - Galvanic insulation input / output / power supply / relays / communication - Universal power supply non polarized AC - DC - Setting parameters backup on FLASH - Possible firmware update Versions and order codes: BGL144-1: BGL144-2: Single strip light with display version Dual strip light with display version BGL144L: BGL144H: Low cost version (without 4 digits display) Horizontal mounting version OPTION : /R1: /R2: /S: /CM /CP /CMTCP 1 relay for each measure channels 1 relays for each measure channels 1 analog output for each measure channels RS485 MODBUS / JBUS link RS485 PROFIBUS-DP link Ethernet MODBUS TCP link 1 insulated analog output for each measure channels in option current or voltage settable: 0 ... 4 ... 20 mA ; 0...1...5...10 V Settable response time and burn-out value for each output Remarks: Communication interface: * default display color: red Several communication protocol available in option for measure reading: - RS485 : Modbus , Profibus - Ethernet : Modbus TCP Connectors : * /R2, /S, /CM, /CP, CMTCP options may not be combined ! removable screw connections spring plug connectors on request BARGRAPH E1 90 days accuracy (20 °C +/- 2 °C) THIS DATASHEET CAN BE DOWNLOADED ON WWW.LOREME.FR TYPE Voltage Input impedance INPUT (12 bits resolution) CALIBER ACCURACY 200 mV +/- 0.3mV >1 M Voltage Input impedance 20 V 250 k +/- 0.015 V Voltage Input impedance 200 V 2 M +/- 0.15 V Current Input impedance 20 mA 100 +/- 0.01 mA TECHNICAL SPECIFICATIONS RECOMMENDED OPERATING CONDITIONS Temperature: Operating -10 à +60 °C Storage -20 à +85 °C Influence 0.005 % / °C (of full scale) Relative humidity 85 % (non condensed) Weight ~ 400g Tightness IP20, (IP54 in option) Dielectric strength inputs / power supply / relays 1500 Vac continuous POWER SUPPLY (to be defined at order) 20 à 265 Vac / Vdc, 3 VA 9 à 30 Vdc, 3 W Reverse polarity protection Response time: 125 ms / Channel (8 measures per seconds) ANALOG OUTPUT RANGE ACCURACY 0 ... 4 ... 20 mA +/- 10 µA 750 Ohms TYPE Current Maximum load Electromagnetic Compatibility RELAYS Insulated reverser contact - Switching power : 1 A / 250 Vac COMMUNICATION Modbus RTU on RS485 from 1200 to 38400 bauds Profibus DP on RS485 from 9600 to 1.5M bauds. Wires on terminal connection Modbus TCP on Ethernet 10/100 base T (RJ 45 connection) Generic standards: NFEN50081-2 / NFEN50082-2 EN55011 EN61000-4-2 EN61000-4-4 EN61000-4-5 EN61000-4-8 EN61000-4-11 meet no influence < +/- 5 % < +/- 5 % no influence < +/- 5 % group 1 / class A B ENV50140 B ENV50141 B ENV50204 A B DBT < +/- 5 % < +/- 10 % no influence 73/23/CEE WIRING AND OUTLINE DIMENSIONS: Cut-off format: 44 x 139 E 2 LOREME 12, rue des Potiers d'Etain - 57071 Metz 03.87.76.32.51 - Fax 03.87.76.32.52 - Email: [email protected] - [email protected] On account of the constant technologies and standards evolution, LOREME keeps the possibility to modify the specifications of the included products without notice.
© Copyright 2026 Paperzz