Data sheet: Wilo-Stratos GIGA 40/1-45/3,8-R1 Pump curves Approved fluids (other fluids on request) H/m Wilo-Stratos GIGA 40/1-45/3,8 Qmin 50 p/kPa 500 n=const. 100% 40 400 90% 30 300 80% Heating water (in accordance with VDI 2035) • Water-glycol mixtures (for 20-40 vol.% glycol and fluid temperature ≤ 40 °C) • Cooling and cold water • Heat transfer oil Special version at additional charge 70% 20 200 60% 50% 10 100 40% 30% 10% 0 0 5 10 0 15 2 20 25 4 30 6 35 Q/m³/h 0 Permitted field of application 10 Q/l/s 8 Standard version for operating pressure P1/kW 100% 4 90% 3 80% 2 70% 1 0 60% 0 40% 30% 10% 5 10 15 50% 20 25 H/m 30 pmax 16 bar (up to +120 °C) bar 13 bar (up to +140 °C) bar Temperature range at max. ambient temperature +40 °C -20...+140 °C (depending on the fluid) Max. ambient temperature 40 °C Installation in closed buildings • Outdoor installation − 35 Q/m³/h Wilo-Stratos GIGA 40/1-45/3,8 p/kPa 500 Pipe connections 400 Nominal flange diameter DN 40 30 300 Flanges (according to EN 1092-2) PN 16 20 200 Flange with pressure-measurement connections R 1/8 10 100 Qmin 50 Δp-c 40 Δp 0 0 5 0 Δp-c P1/kW 3 2 1 0 0 max -v 10 2 15 20 4 . 25 6 30 45m Materials Pump housing EN-GJL-250 Lantern EN-GJL-250 23m Impeller PPS-GF40 Impeller (special version) – Pump shaft 1.4122 Mechanical seal AQ1EGG Other mechanical seals On request 12m 5 1m 10 15 20 25 30 35 Q/m³/h η hyd./% NPSH/m 12 80 η hyd. 8 40 4 0 0 10 Q/l/s 8 34m 35 Q/m³/h NPSH 0 5 10 15 20 25 30 35 Q/m³/h 0 Electrical connection Mains connection Speed 3~480 V ±10%, 50/60 Hz 3~440 V ±10%, 50/60 Hz 3~400 V ±10%, 50/60 Hz 3~380 V ±10%, 50/60 Hz n 500 - 4850 rpm Minimum Efficiency Index (MEI) Minimum Efficiency Index (MEI) ≥ 0.70 Motor/electronics Motor technology Subject to change without prior notice. www.wilo.co.uk 50 Hz EC motor 2015-02 1/7 Data sheet: Wilo-Stratos GIGA 40/1-45/3,8-R1 Dimension drawing ∅168 Integrated full motor protection • Protection class IP 55 Insulation class F Emitted interference EN 61800-3 Interference resistance EN 61800-3 Residual-current protection device (RCD) • No. of poles 6 Rated current (approx.) IN 3~40 6.6 A 0V Maximum power consumption P1 4.1 kW Nominal motor power P2 3.8 kW 140 89 89 280 Ø 150 Ø 110 Ø 84 50 Ø18 120 40 4 x Ø 19 50 90 3 x M12 x 20 78 463 129 277 1xM12/2xM16/1xM20/1xM25 225 248 DN 40 Installation options Pipe installation (≤ 15 kW motor power) • Support-bracket mounting • Information for order placements Weight approx. m 41 kg Make Wilo Type Stratos GIGA 40/1-45/3,8-R1 Art no. 2117155 Please observe pump name plate data Subject to change without prior notice. www.wilo.co.uk 50 Hz 2015-02 2/7 Dimensions and dimension drawings: Wilo-Stratos GIGA 40/1-45/3,8-R1 Dimension drawing ∅168 140 89 89 280 50 Ø18 120 4 x Ø 19 50 Ø 150 Ø 110 Ø 84 90 3 x M12 x 20 78 463 129 277 1xM12/2xM16/1xM20/1xM25 225 248 DN 40 40 Subject to change without prior notice. www.wilo.co.uk 50 Hz 2015-02 3/7 Pump curves: Wilo-Stratos GIGA 40/1-45/3,8-R1 Pump curves H/m Wilo-Stratos GIGA 40/1-45/3,8 Qmin 50 p/kPa 500 n=const. 100% 40 400 90% 30 300 80% 70% 20 200 60% 50% 10 100 40% 30% 10% 0 0 5 10 0 15 2 20 25 4 30 6 35 Q/m³/h 0 10 Q/l/s 8 P1/kW 100% 4 90% 3 80% 2 70% 1 0 60% 0 40% 30% 10% 5 10 15 50% 20 25 H/m 35 Q/m³/h Wilo-Stratos GIGA 40/1-45/3,8 Qmin 50 30 p/kPa 500 Δp-c 400 40 Δp max -v . 30 300 20 200 10 100 0 0 5 0 Δp-c P1/kW 3 2 1 0 0 10 2 15 20 4 25 6 30 45m 23m 12m 5 1m 10 15 20 25 30 35 Q/m³/h η hyd./% NPSH/m 12 80 η hyd. 8 40 4 0 0 10 Q/l/s 8 34m 35 Q/m³/h NPSH 0 5 10 15 20 25 30 Subject to change without prior notice. 35 Q/m³/h 0 www.wilo.co.uk 50 Hz 2015-02 4/7 Specification texts: Wilo-Stratos GIGA 40/1-45/3,8-R1 High-efficiency in-line pump with EC motor (efficiency levels above IE4 limit values acc. to IEC TS 60034-31 Ed.1) and electronic duty adaptation in glanded pump design. The pump is configured as a single-stage low-pressure centrifugal pump with flange connection and mechanical shaft seal. The Stratos GIGA has been predominantly designed for pumping heating water (acc. to VDI 2035), cold water and water/glycol mixtures without abrasive substances in heating, air-conditioning and cooling systems. Design • Single-stage low-pressure centrifugal pump with one-piece shaft in monobloc design • Spiral housing in in-line design (suction and pressure ports with the same flanges in a line) • PN 16 flange – drilled according to EN 1092-2 • Pump housing and motor flange with cataphoretic coating as standard • Mechanical seal for pumping water up to Tmax. = +140°C. A glycol admixture of 20 to 40% by volume is permitted up to T ≤ +40°C. An alternative mechanical shaft seal must be provided in water/glycol mixtures with glycol proportions > 40% up to maximum 50% by volume and a fluid temperature of > + 40°C up to maximum +120°C or fluids other than water. • Connection voltages 3~400 V ±10%, 50/60 Hz, 3~380 V -5%/+10%, 50/60 Hz Accessories: • Mounting brackets for fixing to the foundation Standard equipment: • Red button manual operation level for: • Pump display for displaying: Additional functions: • Analogue interfaces 0-10 V, 2-10 V, 0-20 mA, 4-20 mA, built-in dual pump management, two configurable signalling relays for operating and fault signals, configurable fault response adapted to HVAC applications, access disable on the pump, built-in full motor protection (TRS) with trip electronics, condensation drain holes in the motor housing as standard (sealed in delivered condition), infrared interface for wireless communication with the operating and service device Wilo-IR-Module and Wilo-IR-Monitor, plug-in position for Wilo IF-Module Modbus, BACnet, CAN, PLR, LON for connecting to the building automation. Materials Pump housing: EN-GJL-250 Lantern: EN-GJL-250 Impeller: PPS-GF40 Pump shaft: 1.4122 Mechanical seal: AQ1EGG Permitted field of application Standard version for operating pressure: 16 bar (up to +120 °C) / bar13 bar (up to +140 °C) bar Temperature range at max. ambient temperature +40 °C: -20...+140 °C (depending on the fluid) Max. ambient temperature: 40 °C Pipe connections Nominal flange diameter: DN 40 Overall length: 280 mm Flanges (according to EN 1092-2): PN 16 1 Flange with pressure-measurement connections: R / 8 Subject to change without prior notice. www.wilo.co.uk 50 Hz 2015-02 5/7 Specification texts: Wilo-Stratos GIGA 40/1-45/3,8-R1 Minimum Efficiency Index (MEI) Minimum Efficiency Index (MEI): ≥ 0.70 Motor/electronics Integrated full motor protection: • Protection class: IP 55 Insulation class: F Emitted interference: EN 61800-3 Interference resistance: EN 61800-3 Mains connection: 3~480 V ±10%, 50/60 Hz / 3~440 V ±10%, 50/60 Hz / 3~400 V ±10%, 50/60 Hz / 3~380 V ±10%, 50/60 Hz Speed: 500 - 4850 rpm No. of poles: 6 Rated current (approx.): 6.6 A Maximum power consumption: 4.1 kW Nominal motor power: 3.8 kW Weight Weight approx.: 41 kg Information for order placements Art no.: 2117155 Type: Stratos GIGA 40/1-45/3,8-R1 Make: Wilo Subject to change without prior notice. www.wilo.co.uk 50 Hz 2015-02 6/7 Terminal diagram : Wilo-Stratos GIGA 40/1-45/3,8-R1 Terminal diagram L1 L2 L3 PE PE SSM SBM AUX Ext. off L H In2 GND In1 GND +24V L1, L2, L3: Mains connection: 3~380 V - 3~480 V (±10 %), 50/60 Hz PE: Protective conductor connection DDG: Connection for differential pressure sensor In1 (1): Actual value input 0-10 V/0-20 mA; 2-10 V/4-20 mA GND (2): Ground connection for In1 and In2 + 24 V (3): DC voltage output for an external consumer/sensor. Max load 60 mA In2: Setpoint input 0-10 V/0-20 mA; 2-10 V/420 mA MP: Multi-pump, interface for dual pump management MP (1) (2) (3) Ext. off: DDG "Overriding Off" control input The pump can be switched on or off via an external, potential-free contact (24 V DC/10 mA). O OFF Subject to change without prior notice. S ON www.wilo.co.uk 50 Hz SBM:* Potential-free collective run signal (changeover contact according to VDI 3814) SSM:* Potential-free collective fault signal (changeover contact according to VDI 3814) aux: External pump cycling (only with dual pump operation). Pump cycling can be performed using an external, potential-free contact (24 VDC/10 mA) DIP switch: 1: Switchover between operation (O) and service mode (S) 2: Activate/deactivate the menu for access disable Option: IF-Module for connection to building automation 2015-02 7/7
© Copyright 2026 Paperzz