PowerPlex Fusion 6C System ® Performance Packed. Performance Packed. The PowerPlex® Fusion 6C System offers rapid-cycling, direct-amplification capabilities and superior sensitivity along with SE33 and three Y-STR loci for improved mixture interpretation and unbeatable performance with challenging casework samples. Additionally, the system is optimized and QC-tested to work at full- or half-volume reactions with some protocol modifications recommended depending on sample type. This six-color system allows co-amplification and fluorescent detection of the new 20 CODIS Core Loci: CSF1PO, D3S1358, D5S818, D7S820, D8S1179, D13S317, D16S539, D18S51, D21S11, FGA, TH01, TPOX, vWA, D1S1656, D2S441, D2S1338, D10S1248, D12S391, D19S433 and D22S1045 (1) plus Amelogenin and DYS391 for gender discrimination. Penta D, Penta E and SE33 also are included to increase discrimination and allow searching of databases that contain profiles with these loci. Eleven loci are less than 250bp, making them ideal for working with degraded samples. Finally, two rapidly mutating Y-STR loci, DYS570 and DYS576, are included in the multiplex to help determine the number of contributors in a mixture. D3S1358 D16S539 TH01 D8S1179 DYS391 60 65 100 D1S1656 D2S441 D2S1338 D18S51 vWA D12S391 D10S1248 D21S11 CSF1PO D7S820 D19S433 D5S818 Penta E Penta D TPOX SE33 FGA 200 D13S317 D22S1045 DYS576 300 DYS570 400 500 12469MA A* *A = Amelogenin Figure 1. Configuration of the PowerPlex® Fusion 6C System. The PowerPlex® Fusion 6C System allows co-amplification and fluorescent detection of 27 loci, including all CODIS and ESS loci: D3S1358, D1S1656, D2S441, D10S1248, D13S317, D16S539, D18S51, D2S1338, CSF1PO, TH01, vWA, D21S11, D7S820, D5S818, TPOX, D8S1179, D12S391, D19S433, SE33, D22S1045, FGA and DYS391, as well as DYS576, DYS570, Penta E, Penta D and Amelogenin. 1. Hares, D.R. (2015) Selection and implementation of expanded CODIS core loci in the United States. Forensic Sci. Int. Genet. 17, 33–4. Enhanced Sensitivity 25,000 120 PowerPlex® Fusion 6C System 20,000 100 GlobalFiler® PCR Amplification Kit 80 15,000 60 10,000 40 5,000 Investigator® 24Plex QS Kit 20 2ng 1ng 500pg 250pg 125pg 62.5pg 31.2pg 0 13141MA 0 Alleles Called (%) Peak Height (RFU) The PowerPlex® Fusion 6C System reliably produces complete profiles from as little as 125pg of human DNA and useable, partial profiles from DNA inputs lower than 125pg. Input DNA Amount Figure 2. The average peak heights (vertical bars) and percentage of alleles called (diamonds) at varying amounts of 2800M Control DNA. Error bars represent the standard deviation of the mean from triplicate amplification reactions. Superior Inhibitor Tolerance Casework samples are typically laden with inhibitors and can often require laboratories to re-amplify samples and repeat analyses. The PowerPlex® Fusion 6C System contains a robust buffer system to meet those challenges head on and increases your chances for success with even the most difficult samples. 120 PowerPlex® Fusion 6C System GlobalFiler® PCR Amplification Kit Figure 3. Resistance to PCR inhibitors. Human genomic DNA (1ng) was amplified with the indicated kits in the presence of common PCR inhibitors. Amplified products were separated on an Applied Biosystem® 3500 Genetic Analyzer (1.2kV, 15-second injection). Percentage of alleles detected is indicated for each system. 80 60 40 20 0 12560MA Alleles Called (%) 100 500µM 750µM Hematin 1,000µM 100ng/µl 200ng/µl 300ng/µl 100ng/µl 300ng/µl 400ng/µl Humic Acid Tannic Acid PowerPlex® Fusion 6C System Direct-Amplification Capabilities The PowerPlex Fusion 6C System allows direct amplification from unwashed FTA® card punches as well as pretreated nonFTA card punches and typically used swabs to streamline workflows and expand your laboratory’s sample throughput. Extracted DNA FTA® Punches NonFTA Punches Swabs Extract DNA from sample Punch FTA® card into plate Punch card into plate; treat with PunchSolution™ Reagent Incubate swab in SwabSolution™ Reagent Add up to 15µl of sample to reaction Add PCR amplification mix Add PCR amplification mix to dried punch Add 2µl of extract to PCR amplification mix ® 11140MC To maximize the cost effectiveness of STR systems, many laboratories incorporate the use of half-volume (12.5μl) amplification reactions in their workflow. The PowerPlex® Fusion 6C system is designed and QC-tested to work at full- or half-volume reactions with various protocol modifications recommended depending on sample type. Cycling time ~65 minutes for all applications FTA® Punch Analysis Buccal Swab Analysis Buccal Sample on FTA® Card D1S1656 D3S1358 A… 50 100 150 D2S441 200 D10S1248 250 300 D13S317 350 Swab Sample Penta E D3S1358 A… 400 450 500 50 8000 100 D1S1656 150 D2S441 D10S1248 200 250 200 250 300 D13S317 350 Penta E 400 450 500 450 500 450 500 8000 4000 4000 0 0 D16S539 50 100 D18S51 150 D2S1338 200 250 CSF1PO 300 350 Penta D 400 450 D16S539 500 50 8000 100 D18S51 150 D2S1338 CSF1PO 300 350 Penta D 400 8000 4000 4000 0 0 TH01 50 100 vWA 150 D21S11 200 250 D7S820 300 TPOX D5S818 350 TH01 400 450 500 50 8000 8000 4000 4000 0 100 vWA 150 D21S11 200 D7S820 250 300 250 300 250 300 D5S818 350 TPOX 400 0 D8S1179 50 100 D12S391 150 SE33 D19S433 200 250 300 350 D22S1045 400 450 D8S1179 500 50 8000 8000 4000 4000 0 100 D12S391 D19S433 150 200 150 200 SE33 350 D22S1045 400 450 500 450 500 0 100 150 200 DYS576 250 300 350 DYS391 DYS570 400 450 50 500 8000 4000 0 Figure 4. Direct amplification of two 1.2mm punches from a buccal sample on an FTA® card. Two 1.2mm punches were added to a plate, and PCR amplification mix was added to the punches following the recommended protocol for 12.5µl reactions. Amplified products were separated using an Applied Biosystems® 3500 Genetic Analyzer (1.2kV, 15-second injection). 100 FGA DYS576 350 DYS570 400 8000 4000 0 Figure 5. Direct amplification of DNA from buccal swabs. A buccal swab was pretreated with SwabSolution™ Reagent as recommended in the SwabSolution™ Kit Technical Manual. Following incubation, 2μl of extract was added to the PCR amplification mix using the recommended protocol for 12.5µl reactions. Amplified products were separated using an Applied Biosystems® 3500 Genetic Analyzer (1.2kV, 15-second injection). 12563MA 50 FGA 12562MA DYS391 PowerPlex® Fusion 6C System NonFTA® Punch Analysis Buccal Sample on Bode Buccal DNA Collector™ Device D1S1656 D3S1358 A… 50 100 150 D2S441 D10S1248 200 250 200 250 300 D13S317 350 Figure 6. Direct amplification of a single 1.2mm punch from a buccal sample collected using the Bode Buccal DNA Collector™ device. A punch was pretreated with PunchSolution™ Reagent as recommended in the PunchSolution™ Technical Manual. Following incubation, PCR amplification mix was added to the dried punch following the recommended protocol for 12.5µl reactions. Amplified products were separated using an Applied Biosystems® 3500 Genetic Analyzer (1.2kV, 15-second injection). Penta E 400 450 500 450 500 450 500 14000 7000 0 D16S539 50 100 D18S51 150 D2S1338 CSF1PO 300 350 Penta D 400 14000 7000 0 TH01 50 100 vWA 150 D21S11 200 D7S820 TPOX D5S818 250 300 350 250 300 350 250 300 400 14000 7000 0 D8S1179 50 100 D12S391 SE33 D19S433 150 200 150 200 D22S1045 400 450 500 450 500 14000 7000 0 100 FGA DYS576 350 DYS570 400 7000 0 13144MA DYS391 50 14000 Product Information The PowerPlex® Fusion 6C System is compatible with the Applied Biosystems® 3500 and 3500xL Genetic Analyzers as well as Applied Biosystems® 3130 and 3130xl Genetic Analyzers with Data Collection Software Version 4.0 with the DC v4 6-Dye Module v1 License (Life Technologies). Each PowerPlex® Fusion 6C System contains: • PowerPlex® Fusion 6C 5X Master Mix • PowerPlex® Fusion 6C 5X Primer Pair Mix • 2800M Control DNA, 10ng/μl • Water, Amplification Grade • PowerPlex® Fusion 6C Allelic Ladder Mix • WEN Internal Lane Standard 500 For more information, visit: www.promega.com/PowerPlexFusion PowerPlex® Fusion 6C System Ordering Information Product Size Cat.# 50 (or 100 direct-amp) reactions DC2705 200 (or 400 direct-amp) reactions DC2720 5 preps DG4900 PunchSolution Kit 100 preps DC9271 SwabSolution Kit 100 preps DC8271 5X AmpSolution Reagent 100 preps DM1231 PowerPlex Fusion 6C System ® PowerPlex 6C Matrix Standard ® ™ ™ ™ Maxwell, Plexor and PowerPlex are registered trademarks of Promega Corporation. AmpSolution, Differex, DNA IQ, Identity Automation, PowerQuant, PunchSolution, Slicprep and SwabSolution are trademarks of Promega Corporation. Applied Biosystems is a registered trademark of Applied Biosystems. Bode Buccal DNA Collector is a trademark of the Bode Technology Group, Inc. FTA is a registered trademark of Flinders Technologies, Pty, Ltd., and is licensed to Whatman.GlobalFiler is a registered trademark of Life Technologies. Investigator is a registered trademark of Qiagen GmbH Corp. Products may be covered by pending or issued patents or may have certain limitations. Please visit our Web site for more information. PROMEGA CORPORATION www.promega.com • • 2800 WOODS HOLLOW ROAD © 2016 PROMEGA CORPORATION • ALL RIGHTS RESERVED • • MADISON, WI 53711-5399 USA • PRICES AND SPECIFICATIONS SUBJECT TO CHANGE WITHOUT PRIOR NOTICE • TELEPHONE 608-274-4330 PRINTED IN USA 8/16 • 32644123 • PART #BR277
© Copyright 2026 Paperzz