EF205, EF370 electronic overload relays 63 to 380 A 2CDC231010V0012 Description The EF205 and EF370 are self-supplied electronic overload relays, which means no extra external supply is needed. It offers reliable protection for motors in the event of overload or phase failure. Easy to use like a thermal overload relay and compatible with standard motor applications, the electronic overload relay is convincing, above all, due to its wide setting range, high accuracy, high operational temperature range and the possibility to select a trip class (10E, 20E, 30E). Further features are the temperature compensation, trip contact (N.C.), signal contact (N.O.), automatic or manual reset selectable, trip-free mechanism, STOP and TEST function and a trip indication. The overload relays are connected directly to the contactors. EF205-210 Ordering details Setting range Short-circuit protective device A 63 ... 210 Type Order code 1250 A, Fuse type gG 10E, 20E, 30E EF205-210 1SAX531001R1101 Weight (1 pce) kg 1.210 1600 A, Fuse type gG 10E, 20E, 30E EF370-380 1SAX611001R1101 1.430 2CDC231013V0012 115 ... 380 Trip class EF370-380 Main dimensions mm, inches 122.8 17.9 122 4.8" 30 1.18" 4.83" 4.59" 5 0.2" 17.5 0.69" Ø 0.33" 35 1.38" 35 1.38" 35 1.38" 2CDC232004F0012 Ø 8.5 10 0.39" 18.5 0.73" 5 0.2" 0.7" 11 0.43" 7.4 0.29" 116.5 10 0.39" 4.13" 151 5.9" 105 5 0.2" 121.7 4.79" EF205-210 122.8 10 0.39" 5 0.2" 43.8 1.72" EF370-380 C2 | ABB 20 0.79" 43.8 1.72" 35 1.38" 5 0.2" 121.7 4.79" 2CDC107040C0201 Ø 0.43" 2CDC232005F0012 Ø 11 14 0.55" 22.8 0.9" 122 5 0.2" 30 1.18" 6.4" 0.7" 4.83" 4.59" 163.6 17.9 93.8 3.69" 0.29" 0.4' 7.4 116.5 4.13" 11 0.43" 105 EF205, EF370 electronic overload relays Technical data Main circuit – Utilization characteristics according to IEC/EN Type Standards Rated operational voltage Ue Rated frequency Trip class Number of poles Duty time Operating frequency without early tripping Rated impulse withstand voltage Uimp Rated insulation voltage Ui EF205, EF370 IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1 1000 V AC 50/60 Hz 10E, 20E, 30E, selectable 3 100 % Up to 15 operations/h, see "Technical diagram – Intermittent periodic duty" 8 kV 1000 V Auxiliary circuit according to IEC/EN Type Rated operational voltage Ue Conventional free air thermal current Ith Rated frequency Number of poles Ie / Rated operational current AC-15 acc. to IEC/EN 60947-5-1 for utilization category 110-120 V 220-230-240 V 400 V 480-500 V Ie / Rated operational current DC-13 acc. to IEC/EN 60947-5-1 for utilization category 24 V 60 V 110-120-125 V 250 V Minimum switching capacity Short-circuit protective device Rated impulse withstand voltage Uimp Rated insulation voltage Ui EF205, EF370 600 V AC / DC 6A DC, 50/60 Hz 1 N.C. + 1 N.O. 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 3.00 3.00 1.10 0.75 A A A A 1.50 A 0.55 A 0.55 A 0.27 A 12 V / 3 mA 6 A, Fuse type gG 6 kV 690 V Technical diagram – Intermittent periodic duty (Op/h) 140 100 ta = 0.5 80 = 60 ta = 5 s 40 60 80 100 (%) duty ratio 2CDC232005F0211 20 20 s 1.5 s 3s ta = 0 1 ta = 40 0 s ta switching frequency 120 2CDC107040C0201 ta: Motor starting time ABB | C3 EF205, EF370 electronic overload relays Technical data Main circuit – Utilization characteristics according to UL/CSA Type Standards Maximum operational voltage Trip rating Full load amps (FLA) Short-circuit rating RMS symmetrical Short-circuit protective device EF205, EF370 UL 508, CSA 22.2 No. 14, UL 600 V AC 125 % of FLA See table "Full load amps and See table "Full load amps and See table "Full load amps and 60947-4-1A short-circuit protective device" short-circuit protective device" short-circuit protective device" Auxiliary circuit according to UL/CSA Type Contact rating N.C., 95-96 N.O., 97-98 Conventional thermal current EF205, EF370 B600, Q600 B600, Q600 6A Full load amps and short-circuit protective device Type 210 A 380 A Short-circuit protective device 480 V AC SCCR Fuse type 10 kA 400 A, R5/RK5 18 kA 800 A, L/T 600 V AC SCCR 10kA 18kA Fuse type 400 A, R5/RK5 800 A, L/T SCCR 100 kA - Fuse type 400 A, J - 2CDC107040C0201 EF205-210 EF370-380 Full load amps (FLA) C4 | ABB EF205, EF370 electronic overload relays Technical data General data Type Pollution degree Phase loss sensitive Ambient air temperature Operation Open - compensated acc. to IEC/EN 60947-4-1 Storage Ambient air temperature compensation Maximum operating altitude permissible Resistance to shock acc. to IEC 60068-2-27 Resistance to vibrations acc. to IEC 60068-2-6 Mounting position Mounting housing Degree of protection EF205, EF370 3 Yes -25 ... +70 °C -50 ... +85 °C Acc. to IEC/EN 60947-4-1 2000 m 25 g / 11 ms 5 g / 3 … 150 Hz Position 1-6 Mount on the contactor and tighten the screws of the main circuit terminals IP20 main circuit terminals IP00 Electrical connection Main circuit Type Connecting capacity Rigid Flexible Lugs Bars Stranded acc. to UL/CSA Flexible acc. to UL/CSA 1x 2x 1x 2x L≤ Ø> 1x 2x 1x 2x Stripping length Tightening torques Connection screw Auxiliary circuit Type Connecting capacity EF370 16 ... 185 mm² 16 ... 120 mm² 16 ... 185 mm² 16 ... 120 mm² 24 mm 8 mm AWG 6-0000 AWG 6-0000 AWG 6-0000 AWG 6-0000 18 Nm / 160 lb.in M8 50 ... 240 mm² 50 ... 150 mm² 50 ... 240 mm² 50 ... 150 mm² 32 mm 10 mm AWG 1-500 kcmil AWG 1-500 kcmil AWG 1-500 kcmil AWG 1-500 kcmil 28 Nm / 247 lb.in M10 EF205, EF370 1 or 2 x 1 or 2 x 1 or 2 x 1 or 2 x 1 or 2 x 1 or 2 x 1 ... 4 mm² 0.75 ... 2.5 mm² 0.75 ... 2.5 mm² 0.75 ... 2.5 mm² AWG 18-10 AWG 18-10 9 mm 0.8 ... 1.2 Nm / 7 ... 11 Ib.in M3.5 (Pozidriv 2) 2CDC107040C0201 Rigid Flexible with ferrule Flexible with insulated ferrule Flexible Stranded acc. to UL/CSA Flexible acc. to UL/CSA Stripping length Tightening torques Connection screw EF205 ABB | C5
© Copyright 2026 Paperzz