Data sheet - Leuze electronic

Leuze electronic
PRK 96
Retro-reflective photoelectric sensors with polarisation filter
Dimensioned drawing
10m
28m
10 - 30 V
DC
A2 LS
z Polarised retro-reflective photoelectric
sensor with large operating range in visible
red light
z Robust metal housing with glass cover or
plastic housing, protection class IP 67 for
industrial application
z Complementary outputs for standard
applications and a wide range of input and
output variants for optimum adaptation to
the application
z Connection via M12 connector or terminal
compartment
z Multiple options with warning output, activation input, switching delays and optics
heating for use at low temperatures
A
B
C
D
E
F
G
H
I
K
L
Indicator diode green
Indicator diode yellow
Receiver
Transmitter
Optical axis
Device plug M12x1
Screwed cable gland M 16x1.5 for Ø 5 … 10mm
Countersinking for SK nut M5, 4.2 deep
Connection terminals
Cable entry
Sensitivity adjustment
Electrical connection
C
UL
US
We reserve the right to make changes • 96_b14e.fm
LISTED
IEC 60947...
IEC 60947...
IP 67
Accessories:
(available separately)
z Mounting systems
(BT 96, BT 96.1, UMS 96, BT 450.1-96)
z M12 connectors (KD …)
z Ready-made cables (K-D …)
z Reflectors
z Reflective tapes
Leuze electronic GmbH + Co. KG
www.leuze.de
Post-box 1111 D-73277 Owen-Teck Tel. +49 7021 5730
PRK 96 K/P… - 09
Leuze electronic
PRK 96
Specifications
Tables
10m models
Optical data
Typ. operating range limit (TK(S) 100x100)
Operating range 2)
Light spot diameter
Light source
Wavelength
1)
10m/28m
see tables
approx. 130mm at 6m
LED (modulated light)
660nm (visible red light, polarised)
Timing
Switching frequency
Response time
Delay before start-up
1000Hz/20Hz
0.5ms/25ms
≤ 200ms
Electrical data
Operating voltage UB
Residual ripple
Bias current
Switching output
Function characteristics
Signal voltage high/low
Output current
Sensitivity
10 … 30VDC (incl. residual ripple)
≤ 15% of UB
≤ 40mA, ≤ 75mA with optics heating
PNP transistor
light/dark switching (reversible)
≥ (UB -2V)/≤ 2V
max. 100mA
adjustable
0.3 … 8m
0.3 … 7m
0.3 … 4.5m
0.3 … 3m
0.3 … 6m
0.3 … 4m
1
2
3
4
5
6
0.1
0.1
0.1
0.1
0.1
0.1
8
4.5
4
3
4
1 TK(S)
10
7
5
8.5
6
5.5
7.5
Operating
range
100x100 0.3 … 28m
1 0.1
26
28
Operating range [m]
Typ. operating range limit [m]
polycarbonate
plastic
150g
terminals or M12 connector
Diagrams
10m models
Environmental data
Typ. response behaviour (TKS 100x100)
-20°C … +55°C/-40°C … +55°C
1, 2, 3, 4
II, all-insulated
IP 67
1 (acc. to EN 60825-1)
IEC 60947-5-2
Misalignment y [mm]
150
Options
Warning output autoControl warn
Optics heating
Low temperature
Switching delay (slow oper./release)
PNP transistor, 100mA, counting principle
for temperature changes, prevents fogging
to -35°C
0 … 10s (separately adjustable)
y2
100
50
0
-50
-100
-150
y1
0
2
4
6
8
10
12
Distance x [m]
28m models
Typ. operating range limit: max. attainable range without performance reserve
Operating range: recommended range with performance reserve
1=transient protection, 2=polarity reversal protection, 3=short circuit protection for all outputs, 4=interference blanking
Rating voltage 250VAC
Order guide
Typ. response behaviour (TKS 100x100)
200
Misalignment y [mm]
Ambient temp. (operation/storage)
Protective circuit 3)
VDE safety class 4)
Protection class
LED class
Standards applied
150
y2
100
50
0
-50
-100
y1
-150
-200
0
5
10
15
20
25
30
PRK 96K/P-1380-21
Part No. 500 25164
PRK 96K/P-1380-41
Part No. 500 25166
PRK 96K/P-1365-45
Part No. 501 03003
PRK 96K/P-1360.1-41
Part No. 501 03216
PRK 96K/N-1380-46
Part No. 500 81325
metal
plastic
Light
red light (10m)
source
red light (28m)
Connection terminals
M12 connector
Features
switching delay
warning output
activation input
PIN 2 = NC *
PIN 4 = dark switching
PIN 4 = light/dark reversible
NPN switching output
PRK 96K/P-3368-41
Part No. 500 41042
Equipment Ð
PRK 96K/P-1360-41
Part No. 500 25165
Order code Î
PRK 96K/P-1360-21
Part No. 500 25163
Distance x [m]
Selection table
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
Housing
PRK 96 K/P… - 09
TK(S) 100x100
MTK(S) 50x50
TK(S)
30x50
TK(S)
20x40
TK(S)
82
Tape 2 100x100
Plastic housing
Housing
Optics cover
Weight
Connection type
1)
2)
3)
4)
1
2
3
4
5
6
Reflectors
ready
light path free
light path free, no performance reserve
Mechanical data
Operating
range
28m models
Indicators
LED green
LED yellow
LED yellow flashing
Reflectors
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
y2
y1
x
Remarks
z The polarised retro-reflective photoelectric sensor is
also available with an integrated AS-i chip for direct
connection to the AS-i
system.
z *For direct connection to
AS-i I/O coupling modules
(PRK 96K/P-1365-45 and
PRK 96K/P-1360.1-41)
z
z
0603