Smartlink Meter AP.fm

SMARTLINKTM Meter
10 - 30.9-AP - 1
E - i - 5/11
Assembly Numbers
SMARTLINKTM Meter
Order using one of the configured item numbers below. Segment choices are on the following pages.
Natural gas meters
Nominal flow body size (in)
Configured Item Number
2
0200 SLM
3
0300 SLM
4
0400 SLM
6
0600 SLM
Air meters
Nominal flow body size (in)
Configured Item Number
8
0800 SLM
12
1200 SLM
16
1600 SLM
20
2000 SLM
24
2400 SLM
28
2800 SLM
w w w . m a x o n c o r p . c o m
combustion systems for industry
Maxon reserves the right to alter specifications and data without prior notice.
© 2011 Copyright Maxon Corporation. All rights reserved.
10 - 30.9-AP - 2
E - i - 5/11
SMARTLINKTM Meter
Segment Choice Detail - Gas Meters
Segment Name
Segment Name Description
SENSOR/BODY OR
BDYONLY
Choice of sensor, flow body
or both
FLUID
Choice of fluid
SENSOR CAL (VELOCITY
Sensor calibration
AND TEMP)
SENSOR MATERIAL
Choice of material for sensor
POWER INPUT
(VOLTAGE)
Choice of voltage
I/O CONFIGURATION
Input/output configuration
LCD DISPLAY POSITION
Choice of orientation for LCD
display
SOFTWARE VERSION
Choice of software version
FLOW BODY AND
SCREEN MATERIAL
Choice of material for flow
body and screen
END CONNECTIONS
Choice of end connections
HARDWARE (GASKET,
FSTNRS)
Choice of hardware
TAGGING
Type of tag
INSTRUCTION
LANGUAGE
Choice of language for
instructions
Segment Choices
(DEFAULT is shaded)
B
F
M
N
*
1
*
S
*
A
B
*
1
*
I
U
**
01
*
B
*
A
*
2
ALW
NONE
SSP
SSW
E
F
G
Segment Choice Description
Both (sensor + flow body)
Flow body replacement only
Meter only
(N) Natural gas
(*) N/A flow body only order
(1) Standard velocity/temperature range
(*) N/A flow body only order
316 stainless steel
(*) N/A flow body only order
(A) 24V DC
(B) 100-240 VAC
(*) N/A flow body only order
(1) Analog/digital output mod
(*) N/A flow body only order
(I) Inverted
(U) Upright (standard)
(**) N/A flow body order only
(01) Original release
(*) N/A sensor only order
(B) CS body; CS screen (N.G.)
(*) N/A sensor only order
(A) ANSI 150 lb flanged
(*) N/A sensor order only
(2) None (N.G.)
Aluminum (wire-on)
No tagging
Stainless steel (permanent)
Stainless steel (wire-on)
(E) English
(F) French
(G) German
w w w . m a x o n c o r p . c o m
combustion systems for industry
Maxon reserves the right to alter specifications and data without prior notice.
© 2011 Copyright Maxon Corporation. All rights reserved.
SMARTLINKTM Meter
10 - 30.9-AP - 3
E - i - 5/11
Segment Choice Detail - Air Meters
Segment Name
Segment Name Description
SENSOR/BODY OR BDY
ONLY
Choice of sensor, flow body
or both
FLUID
Choice of fluid
SENSOR CAL (VELOCITY
AND TEMP)
Sensor calibration
SENSOR MATERIAL
Choice of sensor material
POWER INPUT (VOLTAGE)
Choice of voltage
I/O CONFIGURATION
Input/output configuration
LCD DISPLAY POSITION
Orientation of LCD display
SOFTWARE VERSION
Choice of software version
FLOW BODY AND SCREEN
MATERIAL
Choice of material for flow
body and screen
END CONNECTIONS
Choice of end connection
HARDWARE (GASKET,
FSTNRS)
Choice of gasket and
fastener material
SCREEN POSITION
Choice of screen position
TAGGING
Type of tag
INSTRUCTION LANGUAGE
Choice of language for
instructions
Segment Choices
(DEFAULT is shaded)
B
F
M
A
*
1
*
S
*
A
B
*
1
*
I
U
**
01
*
A
*
B
*
1
*
B
L
R
ALW
NONE
SSP
SSW
E
F
G
w w w . m a x o n c o r p . c o m
combustion systems for industry
Maxon reserves the right to alter specifications and data without prior notice.
© 2011 Copyright Maxon Corporation. All rights reserved.
Segment Choice Description
Both (sensor + flow body)
Flow body replacement only
Meter only
(A) Air
(*) N/A flow body only order
(1) Standard velocity/temperature range
(*) N/A flow body only order
(S) 316 stainless steel
(*) N/A flow body only order
(A) 24V
(B) 100-240 VAC
(*) N/A flow body only order
(1) Analog/digital output mod
(*) N/A flow body only order
(I) Inverted
(U) Upright (standard)
(**) N/A flow body order only
(01) Original release
(*) N/A sensor only order
(A) CS body; 304SS screen (air)
(*) N/A sensor only order
(B) ANSI 1/2” thick flanged
(*) N/A sensor order only
(1) Plated fastener/fiber gasket (air)
N/A sensor order only
Bottom position for air
Left position for air standard
Right position for air
Aluminum (wire-on)
No tagging
Stainless steel (permanent)
Stainless steel (wire-on)
(E) English
(F) French
(G) German