TNA820A00 Y2 Y1 R1 B2 B1

TNA820A00
TRISECTOR PENTA-BAND 1x 790-960 MHz, 2x 1710-2170 MHz, 2x 2300-2600 MHz



Compact Antenna
Diameter 635 mm
External RET available
Electrical specifications*
Frequency Range (MHz)
R1 B1, B2 Y1, Y2 790—960
1710-2170
2300-2690
Polarization
Gain (dBi)
±45º
16,5
Electrical Tilt (continuously adjustable)
Horizontal Beamwidth (º), -3dB
Vertical Beamwidth (º), -3dB
16,8
18
2—10
65,2
56,9
60,2
8
7
6,1
Front to Back Ratio (dB)
180º±30º total power
B2 >25
Cross Polar Discrimination (dB)
Boresight
>17
>23
>17
Sidelobe suppresssion (dB)
First sidelobe above horizon
17
17
16
Typ 18
Typ 20
Typ 22
First null fill (dB)
Impedance (W)
VSWR
50
< 1.5:1
Intraband isolation (dB)
> 30
Interband isolation (dB)
> 30
Intermodulation IM3 (dBc)
Max power per input (W)
External RET
Y2 < -150
300
B1 Y1 R1 AISG 2.0 / 3GPP Protocol
*All specifications are subject to change without notice. Refer to TELNET for the most current informa-
Mechanical specifications
Input
Position
Dimensions (mm), H x Ø
30 x 7/16 female connectors
Bottom, 3 x 10 (7/16)
2230 + 300 x 450
Weight (Kg)
102
Max wind speed (Km/h)
200
Azimuth (Full antenna / Per Sector)
1 of 2
± 50º / ± 0º
www.telnet‐ri.es V150803 TNA820A00
Materials
Radome
End Caps
Screws and nuts
Fiber glass + polyester
Stainless Steel
Stainless Steel
Environmental and mechanical tests IEC 60068-2-1: Cold
IEC 60068-2-32: Free Fall Test
IEC 60068-2-2: Dry heat
IEC 60068-2-56: Damp Heat Steady State
IEC 60068-2-6: Sine Vibration
IEC 60068-2-64: Random Vibration
IEC 60068-2-14: Change of Temperature
IEC 60529: IP Code Test
IEC 60068-2-18: Water (Handheld shower)
IEC 60695-2-1/2: Resistance to fire
IEC 60068-2-27: Shock Test
UNE-EN 60598-2-3: Resistance to wind
IEC 60068-2-29: Bump Test
Particular Specification: Resistance to ice
IEC 60068-2-30: Damp Heat Cyclic
Environmental RET test
Temperature
Humidity
Saline Fog
IP specification
2 of 2
–33º C a 70º C
50º C, 98HR
IEC68-2-52, severity 2
IP66, IEC 60529 (Feb 2001)
www.telnet‐ri.es V150803