LINEAR BOX SERIES CEILING INSTALLATION NOTES: 1. FIELD CUT CEILING PANELS AS REQUIRED TO CREATE A RANDOM STAGGERED SEAM PATTERN. AVOID ALIGNED SEAMS. 2. DO NOT SPLICE PANELS DIRECTLY BELOW UNIVERSAL CARRIERS. PANEL SPLICES DO NOT FIT UNDER CARRIERS. 3. IF UNIVERSAL CARRIERS ARE DIRECTLY FASTENED TO STRUCTURE, CARRIER-TO- CARRIER ALIGNMENT TOLERANCES BECOME CRITICAL. CARRIER ALIGNMENT TOLERANCES SHOULD NOT EXCEED 1/32" +/- IN ANY DIRECTION WHEN DIRECT FASTENING CARRIERS TO STRUCTURE. FAILURE TO MAINTAIN TOLERANCES MAY RESULT IN CEILING PANEL DEFORMATION. 1 ", V.I.F. 1'-632 4. 1 Hunter Douglas Circle 5015 Oakbrook Parkway, Suite 100 Thornton, CO 80241 Norcross, GA 30093 866-556-1235 800-366-4327 / 770-806-9557 fax: 720-872-7850 fax: 770-806-0214 PROPER CARRIER TAB ALIGNMENT IS VERY DIFFICULT TO MAINTAIN WHEN CARRIER IS HARD FASTENED TO A RIGID SUBSTRUCTURE SUCH AS T-GRID OR CR STEEL CHANNEL. FOR THIS REASON, HUNTER DOUGLAS CANNOT ACCEPT RESPONSIBILITY FOR THE FINISHED APPEARANCE OF THE CEILING IF THE STRICT TOLERANCE GUIDELINES OUTLINED IN NOTE #3 ARE NOT FOLLOWED. www.hunterdouglascontract.com 18'-919", V.I.F. 32 R M E T A L C E I L I N G S R W O O D C E I L I N G S R 11", V.I.F. 10'-916 17'-223 32", V.I.F. 15'-817 32", V.I.F. 1'-6", V.I.F. A C O U S T I C A L C E I L I N G S 2'-8" O.C. MAX. CARRIER SPACING, SEE DETAIL 1/5 THIS SET X26 4'-0" MAX., TYP. 37'-225 32", V.I.F. UNIVERSAL CARRIER FOR INTERIOR SUSPENSION REQUIREMENTS, SEE DETAIL 1/4 THIS SET FOR INTERIOR SUSPENSION REQUIREMENTS, SEE DETAIL 1/4 THIS SET PROJECT SPECIFIC NOTES FOR INTERIOR SUSPENSION REQUIREMENTS, SEE DETAIL 1/4 THIS SET X28 9 ", V.I.F. 103'-832 UNIVERSAL CARRIER GENERAL NOTES 10'-912", V.I.F. FOR EXTERIOR SUSPENSION REQUIREMENTS, SEE DETAIL 1/5 THIS SET FOR INTERIOR SUSPENSION REQUIREMENTS, SEE DETAIL 1/4 THIS SET X32 Ceiling installation to be in accordance with ASTM C636 & ASTM E580, and local code requirements for seismic bracing. 2. The purpose of these drawings is to represent installation of Hunter Douglas products ONLY. All dimensions are to be field verified and approved by the contractor prior to fabrication. 3. Return approved shop drawings to Hunter Douglas to release for fabrication. 4. All quantities are to be reviewed and approved by the customer prior to fabrication. 5. This material list is an ESTIMATE ONLY. The customer is responsible for reviewing and verifying ALL information listed above prior to ordering material. Excess material will not be accepted for returns or credit. If additional material is necessary, set-up charges may apply. 6. Unless shown otherwise, all penetrations including light fixtures, diffusers, speakers, sprinkler heads, etc., are to be field located and field cut. Hunter Douglas will not be responsible for final location and placement of penetrations. Typically, penetrations are not dimensioned or located on Hunter Douglas shop drawings unless the holes are factory cut. All "fixtures" are to be independently supported. Trim for all penetrations are by others. Any fixture or other penetration shown is soley based on information provided to Hunter Douglas. 7. Architect / General Contractor: Please reference appropriate contract documents for coordination with other trades. 8. If there are any questions in relation to Hunter Douglas products on this project, please contact us at 1-800-366-4327 (8:00am - 5:00pm EST Monday-Friday). 36'-015 32", V.I.F. UNIVERSAL CARRIER FOR INTERIOR SUSPENSION REQUIREMENTS, SEE DETAIL 1/4 THIS SET X35 ADD SUPPLEMENTAL CARRIERS AS REQUIRED TO MAINTAIN MAX PANEL OVERHANG ADD SUPPLEMENTAL CARRIERS AS REQUIRED TO MAINTAIN MAX PANEL OVERHANG UNIVERSAL CARRIER FOR INTERIOR SUSPENSION REQUIREMENTS, SEE DETAIL 1/4 THIS SET All rights reserved. This drawing is the property of Hunter Douglas. It may not be copied or multiplied, neither wholly nor partly. It may not be submitted for perusal to third parties. 2'-2", V.I.F. 5 ", V.I.F. 31'-732 1. 1'-6", V.I.F. UNIVERSAL CARRIER FOR EXTERIOR SUSPENSION REQUIREMENTS, SEE DETAIL 1/5 THIS SET UNIVERSAL CARRIER 2'-8" O.C. MAX. CARRIER SPACING, SEE DETAIL 1/5 THIS SET FOR EXTERIOR SUSPENSION REQUIREMENTS, SEE DETAIL 1/5 THIS SET 71'-3 9 ", V 32 .I.F. ADD SUPPLEMENTAL CARRIERS AS REQUIRED TO MAINTAIN MAX PANEL OVERHANG REVISIONS: 1 1 1. PARTIAL R.C.P. AT HD METAL CEILINGS SCALE: 1/4" = 1'-0" 0 2' 4' Y3 Y2 Y1.9 DATE BY - - 8' NOTES: 1. ALL EDGE TRIM PIECES TO BE BLACK. 2. NO CLOSURE BETWEEN PANELS AT INTERIOR. 3. ALL VISIBLE CEILING SUPPORT MEMBERS TO BE PAINTED BLACK AS REQUIRED. Y6 - FABRICATION MAY PROCEED IF NOTES ON SUBMISSION ARE FOLLOWED, RESUBMITTAL NOT REQUIRED CORRECTION & RESUBMITTAL FOR RECORD PURPOSES REQUIRED DRAWN BY: A PRICE CHECKED BY: DATE: 8/15/14 PAGE SIZE: 36" x 48" (ARCH "E") PROJECT: SHAKE SHACK - LAS VEGAS REJECTED AND RESUBMIT This review is for general conformance with the design concept and contract documents. Markings or comments shall not be constructed as relieving the Contractor from compliance with the project plans and specifications. The Contractor remains responsible for details and accuracy for confirming and correlating all quantities and dimensions which also shall be confirmed at the site for selecting fabrication processes for techniques of assembly and for performing his work in safe manner. By & Date : By Tim Grantham at 2:23 pm, Aug 22, 2014 CUSTOMER: PAGE TITLE: R.C.P. DRAWING NUMBER: 441181-1 SHEET: 1 OF 5 SCALE: 1/4" = 1'-0" LINEAR BOX SERIES CEILING INSTALLATION NOTES: 5 3 EXTERIOR TRIM CONDITION P CEILING ELEVATION 16'-11 3/4" AFF, V.I.F. CEILING ELEVATION 16'-3 1/4" AFF, V.I.F. 1. FIELD CUT CEILING PANELS AS REQUIRED TO CREATE A RANDOM STAGGERED SEAM PATTERN. AVOID ALIGNED SEAMS. 2. DO NOT SPLICE PANELS DIRECTLY BELOW UNIVERSAL CARRIERS. PANEL SPLICES DO NOT FIT UNDER CARRIERS. 3. IF UNIVERSAL CARRIERS ARE DIRECTLY FASTENED TO STRUCTURE, CARRIER-TO- CARRIER ALIGNMENT TOLERANCES BECOME CRITICAL. CARRIER ALIGNMENT TOLERANCES SHOULD NOT EXCEED 1/32" +/- IN ANY DIRECTION WHEN DIRECT FASTENING CARRIERS TO STRUCTURE. FAILURE TO MAINTAIN TOLERANCES MAY RESULT IN CEILING PANEL DEFORMATION. 4. 1 Hunter Douglas Circle 5015 Oakbrook Parkway, Suite 100 Thornton, CO 80241 Norcross, GA 30093 866-556-1235 800-366-4327 / 770-806-9557 fax: 720-872-7850 fax: 770-806-0214 PROPER CARRIER TAB ALIGNMENT IS VERY DIFFICULT TO MAINTAIN WHEN CARRIER IS HARD FASTENED TO A RIGID SUBSTRUCTURE SUCH AS T-GRID OR CR STEEL CHANNEL. FOR THIS REASON, HUNTER DOUGLAS CANNOT ACCEPT RESPONSIBILITY FOR THE FINISHED APPEARANCE OF THE CEILING IF THE STRICT TOLERANCE GUIDELINES OUTLINED IN NOTE #3 ARE NOT FOLLOWED. www.hunterdouglascontract.com 5 3 EXTERIOR TRIM CONDITION W R INTERIOR TRIM CONDITION A INTERIOR TRIM CONDITION A CEILING ELEVATION 12'-0" AFF 1 3 1 3 PANEL NUMBER CEILING ELEVATION 17'-2 3/16" AFF, V.I.F. CEILING ELEVATION 16'-5 1/4" AFF, V.I.F. CEILING ELEVATION 16'-1 15/16" AFF, V.I.F. X26 EXTERIOR TRIM CONDITION P 5 3 1 3 C E I L I N G S TABLE 1 - INTERIOR OBTUSE TRIM CONDITIONS @ WALLS LINEAR BOX CEILING SYSTEM INTERIOR TRIM CONDITION A CEILING ELEVATION 10'-0" AFF CEILING ELEVATION 12'-0" AFF M E T A L TYPICAL SECTION CONDITION A DETAIL 1/3 B DETAIL 2/3 C DETAIL 2/3 D DETAIL 2/3 E DETAIL 2/3 FF DETAIL 2/3 JJ DETAIL 2/3 R W ANGLE OF SLOPE WALL ANGLE (TOTAL ANGLE) O O D C E I L I N G S R A C O U S T I C A L C E I L I N G S TABLE 2 - INTERIOR TRIM CONDITIONS @ SEAMS LINEAR BOX CEILING SYSTEM PANEL NUMBER FLEX TRIM AT COLUMN BY OTHERS, NOT BY HUNTER DOUGLAS INTERIOR TRIM CONDITION G 3 3 3 3 3 3 H DITIO N CON IM TR DETAIL 3/3 TYPICAL SECTION CONDITION HH DETAIL 4/3 CC DETAIL 4/3 KK DETAIL 4/3 W EXTERIOR TRIM CONDITION Q X32 DETAIL 5/3 S DETAIL 5/3 T DETAIL 5/3 U DETAIL 5/3 V DETAIL 5/3 W DETAIL 5/3 TYPICAL SECTION CONDITION X DETAIL 6/3 Y DETAIL 6/3 ANGLE OF SLOPE WALL ANGLE (TOTAL ANGLE) GENERAL NOTES 1. Ceiling installation to be in accordance with ASTM C636 & ASTM E580, and local code requirements for seismic bracing. TYPICAL SECTION CONDITION Q DETAIL 7/3 R DETAIL 7/3 ANGLE OF SLOPE WALL ANGLE (TOTAL ANGLE) 2. The purpose of these drawings is to represent installation of Hunter Douglas products ONLY. All dimensions are to be field verified and approved by the contractor prior to fabrication. 3. Return approved shop drawings to Hunter Douglas to release for fabrication. 4. All quantities are to be reviewed and approved by the customer prior to fabrication. 5. This material list is an ESTIMATE ONLY. The customer is responsible for reviewing and verifying ALL information listed above prior to ordering material. Excess material will not be accepted for returns or credit. If additional material is necessary, set-up charges may apply. 6. Unless shown otherwise, all penetrations including light fixtures, diffusers, speakers, sprinkler heads, etc., are to be field located and field cut. Hunter Douglas will not be responsible for final location and placement of penetrations. Typically, penetrations are not dimensioned or located on Hunter Douglas shop drawings unless the holes are factory cut. All "fixtures" are to be independently supported. Trim for all penetrations are by others. Any fixture or other penetration shown is soley based on information provided to Hunter Douglas. 7. Architect / General Contractor: Please reference appropriate contract documents for coordination with other trades. 8. If there are any questions in relation to Hunter Douglas products on this project, please contact us at 1-800-366-4327 (8:00am - 5:00pm EST Monday-Friday). INTERIOR TRIM CONDITION A CO IM IO INTERIOR TRIM CONDITION HH 4 3 4 3 INTERIOR TRIM CONDITION A INTERIOR TRIM CONDITION A 1 3 2 2 INTERIOR TRIM CONDITION G SCALE: 1 1/2" = 1'-0" INTERIOR INSTALLATION NOTE: ATTACHMENT TO STRUCTURE DESIGNED AND PROVIDED BY OTHERS, NOT BY HUNTER DOUGLAS 4 3 INTERIOR TRIM CONDITION A INTERIOR TRIM CONDITION A CO IN T M ON ITI ND 1 3 K 2 2 SCALE: 1 1/2" = 1'-0" INTERIOR INSTALLATION CEILING ELEVATION 19'-9 3/8" AFF, V.I.F. All rights reserved. This drawing is the property of Hunter Douglas. It may not be copied or multiplied, neither wholly nor partly. It may not be submitted for perusal to third parties. NOTE: ATTACHMENT TO STRUCTURE DESIGNED AND PROVIDED BY OTHERS, NOT BY HUNTER DOUGLAS CEILING ELEVATION 20'-0 1/2" AFF, V.I.F. TE EX 5 3 O RI R 6 3 OR RI J IO IT ND ND IM J N ND ND IT IO CO INTERIOR TRIM CONDITION C INTERIOR TRIM CONDITION CC INTERIOR TRIM CONDITION KK 1 3 INTERIOR TRIM CONDITION JJ TE RIO R K TR N IM CO 2 3 ITIO 4' IM 2' TR 0 R SCALE: 1/4" = 1'-0" RIO PARTIAL R.C.P. AT HD METAL CEILINGS TE 1 2 IN 1 3 INTERIOR TRIM CONDITION C IN IN TE CEILING ELEVATION 25'-1 13/16" AFF, V.I.F. INTERIOR TRIM CONDITION JJ RI OR K TR ON X CO 2 3 ITI ON 7 3 CO ITI R M ND I TR CO NDITI ON Y TE IM TR IM CO IN 6 3 N EXTERIOR TRIM CONDITION V INTERIOR TRIM CONDITION G 1 3 4 3 3 2 SCALE: 1 1/2" = 1'-0" INTERIOR INSTALLATION NOTE: ATTACHMENT TO STRUCTURE DESIGNED AND PROVIDED BY OTHERS, NOT BY HUNTER DOUGLAS INTERIOR TRIM CONDITION CC INTERIOR TRIM CONDITION KK ER IO I TR R R TR INTERIOR TRIM CONDITION A INTERIOR TRIM CONDITION HH ND IT IO N J 4 3 INTERIOR TRIM CONDITION G 1 3 INTERIOR TRIM CONDITION A INTERIOR TRIM CONDITION FF INTERIOR TRIM CONDITION FF X35 INTERIOR TRIM CONDITION C IOR T R CONDITION ANGLE OF SLOPE WALL ANGLE (TOTAL ANGLE) INTERIOR TRIM CONDITION A R TE 5 3 PROJECT SPECIFIC NOTES 1 3 IN 2 3 CEILING ELEVATION 14'-0" AFF, V.I.F. ANGLE OF SLOPE WALL ANGLE (TOTAL ANGLE) TYPICAL SECTION CONDITION P L EXTERIOR TRIM CONDITION U L PANEL NUMBER 3 3 EXTER EXTERIOR TRIM CONDITION S DETAIL 3/3 INTERIOR TRIM CONDITION G 3 2 CEILING ELEVATION 14'-7 13/16" AFF, V.I.F. EXTERIOR T RIM K ON ITI ND INTERIOR TRIM CONDITION D CO CEILING ELEVATION 18'-3 15/16" AFF, V.I.F. DETAIL 3/3 TABLE 6 - EXTERIOR OBTUSE TRIM CONDITIONS @ WALLS LINEAR BOX CEILING SYSTEM CEILING ELEVATION 12'-0" AFF CEILING ELEVATION 14'-2 7/16" AFF, V.I.F. EXTERIOR TRIM CONDITION T J PANEL NUMBER EXTERIOR TRIM CONDITION OR RI TE IN 5 3 DETAIL 3/3 TABLE 5 - EXTERIOR CONDITIONS @ SEAMS LINEAR BOX CEILING SYSTEM 5 3 INTERIOR TRIM CONDITION B CEILING ELEVATION 10'-0" AFF TRIM 1 3 3 3 CEILING ELEVATION 16'-4 1/16" AFF, V.I.F. H PANEL NUMBER 7 3 3 3 5 3 DETAIL 3/3 TABLE 4 - EXTERIOR ACUTE TRIM CONDITIONS @ WALLS LINEAR BOX CEILING SYSTEM 2 3 2 3 G X28 2 2 INTERIOR TRIM CONDITION A DETAIL 3/3 PANEL NUMBER INTE RIOR CEILING ELEVATION 12'-0" AFF F ANGLE OF SLOPE WALL ANGLE (TOTAL ANGLE) TABLE 3 - INTERIOR ACUTE TRIM CONDITIONS @ WALLS LINEAR BOX CEILING SYSTEM INTERIOR TRIM CONDITION G INTERIOR TRIM CONDITION E INTERIOR TRIM CONDITION F 2 3 TYPICAL SECTION CONDITION 1 3 REVISIONS: 1. - DATE BY - - 8' 4 3 3 2 SCALE: 1 1/2" = 1'-0" INTERIOR INSTALLATION NOTE: ATTACHMENT TO STRUCTURE DESIGNED AND PROVIDED BY OTHERS, NOT BY HUNTER DOUGLAS DRAWN BY: A PRICE CHECKED BY: DATE: 8/15/14 PAGE SIZE: 36" x 48" (ARCH "E") PROJECT: SHAKE SHACK - LAS VEGAS CUSTOMER: Y6 Y3 Y2 Y1.9 PAGE TITLE: HD R.C.P. REFERENCE GUIDE DRAWING NUMBER: 441181-2 SHEET: 2 OF 5 SCALE: AS SHOWN 12" MAXIMUM, TYPICAL ALL INTERIOR HD BOX CEILINGS 12 GA HANGER WIRE BY OTHERS, NOT BY HUNTER DOUGLAS 48" MAX O.C. CARRIER SPACING 12" MAXIMUM, TYPICAL ALL INTERIOR HD BOX CEILINGS 12 GA HANGER WIRE BY OTHERS, NOT BY HUNTER DOUGLAS 5015 Oakbrook Parkway, Suite 100 Thornton, CO 80241 Norcross, GA 30093 866-556-1235 800-366-4327 / 770-806-9557 fax: 720-872-7850 fax: 770-806-0214 www.hunterdouglascontract.com FASTENERS BY OTHERS, TYPICAL. NOT BY HUNTER DOUGLAS 12" MAX PANEL OVERHANG, TYP. BOTH ENDS UNIVERSAL BOX CARRIER FIELD CUT & SPLICE TO FIT ALLOW 14" FOR EXPANSION 1" x 34" 'J' CAP TRIM, STANDARD 12 GA HANGER WIRE, TYP., NOT BY HUNTER DOUGLAS R UNIVERSAL BOX CARRIER FIELD CUT & SPLICE TO FIT FASTENERS BY OTHERS, TYPICAL. NOT BY HUNTER DOUGLAS 1 Hunter Douglas Circle M E T A L VARIABLE ANGLE, SEE TABLE 2 ON THIS SHEET VARIABLE ANGLE, SEE TABLE 1 ON THIS SHEET R W UNIVERSAL CARRIER 1" WALL ANGLE BOX 6 CEILING PANEL FIELD CUT & SPLICE TO FIT FACTORY PANEL END, BOX 6 SHOWN, ALL LINEAR BOX PANEL SIZE SIMILAR C E I L I N G S O D C E I L I N G 5" 532 S R FIELD CUT PANEL END, BOX 6 SHOWN, ALL LINEAR BOX PANEL SIZE SIMILAR 27" 32 1" WALL ANGLE, USE ANGLE ABOVE AS HOLD DOWN INSIDE PANEL IF REQUIRED O 1" 1" A C O U S T I C A L C E I L I N G S 1" BOX 6 CEILING PANEL FIELD CUT & SPLICE TO FIT 5" 532 27" 32 DOUBLE SIDED ADHESIVE TAPE TO SECURE ANGLE INTERIOR INSTALLATION 1" x 1" ANGLE INSIDE 'J' TRIM TO SECURE CUT PANEL EDGE INTERIOR INSTALLATION INTERIOR INSTALLATION 1-34" 'J' TRIM 1 3 2 3 NOTE: SCALE: 3" = 1'-0" ATTACHMENT TO STRUCTURE DESIGNED AND PROVIDED BY OTHERS, NOT BY HUNTER DOUGLAS SECTION DETAIL AT OBTUSE WALL ANGLES 3 3 NOTE: SCALE: 6" = 1'-0" ATTACHMENT TO STRUCTURE DESIGNED AND PROVIDED BY OTHERS, NOT BY HUNTER DOUGLAS SECTION DETAIL AT PANELS SEAMS NOTE: SCALE: 6" = 1'-0" ATTACHMENT TO STRUCTURE DESIGNED AND PROVIDED BY OTHERS, NOT BY HUNTER DOUGLAS SEE DETAIL 1/5 THIS SET, TABLE 1 FOR MAX O.C. SPACING REQUIREMENTS 12 GA HANGER WIRE BY OTHERS, NOT BY HUNTER DOUGLAS PROJECT SPECIFIC NOTES 6" MAX CARRIER OVERHANG, SEE DETAIL 1/5 THIS SET, TABLE 1 FOR REQUIREMENTS 12" MAXIMUM, TYPICAL ALL INTERIOR HD BOX CEILINGS VERTICAL SUPPORT DIETRICH STE-20 2-12" 20 GA GALV. STEEL STUD OR EQUAL, MAX LENGTH 85", SEE DETAIL 1/5 THIS SET, NOTE 3 FOR VERTICAL SUPPORT REQUIREMENTS 12 GA HANGER WIRE, WITHIN 3" OF VERTICAL SUPPORT, TYP., NOT BY HUNTER DOUGLAS UNIVERSAL BOX CARRIER FIELD CUT & SPLICE TO FIT UNIVERSAL BOX CARRIER FIELD CUT & SPLICE TO FIT VARIABLE ANGLE, SEE TABLE 3 ON THIS SHEET ALLOW 14" GAP MIN. FOR EXPANSION, TYP. BOTH SIDES SEE DETAIL 1/5 THIS SET, TABLE 1 FOR MAX O.C. SPACING REQUIREMENTS 6" MAX CARRIER OVERHANG, SEE DETAIL 1/5 THIS SET, TABLE 1 FOR REQUIREMENTS 27" 32 VARIABLE ANGLE, SEE TABLE 4 ON THIS SHEET FASTENERS BY OTHERS, TYPICAL. NOT BY HUNTER DOUGLAS VERTICAL SUPPORT DIETRICH STE-20 2-12" 20 GA GALV. STEEL STUD OR EQUAL, MAX LENGTH 85", SEE DETAIL 1/5 THIS SET, NOTE 3 FOR VERTICAL SUPPORT REQUIREMENTS 5" 532 FLAT RECESSED CLOSURE BOX 6 CEILING PANEL FIELD CUT & SPLICE TO FIT ALLOW 14" VARIABLE ANGLE, SEE TABLE 5 ON THIS SHEET FIELD CUT PANEL SIDE, BOX 6 SHOWN, ALL LINEAR BOX PANEL SIZE SIMILAR UNIVERSAL BOX CARRIER FIELD CUT & SPLICE TO FIT 1"X2" WALL ANGLE, USE ANGLE ABOVE AS HOLD DOWN INSIDE PANEL IF REQUIRED 1" GAP MIN. FOR EXPANSION, TYP. BOTH SIDES FLAT RECESSED CLOSURE 12 GA HANGER WIRE, WITHIN 3" OF VERTICAL SUPPORT, TYP., NOT BY HUNTER DOUGLAS FIELD CUT PANEL SIDE, BOX 6 SHOWN, ALL LINEAR BOX PANEL SIZE SIMILAR 1" GENERAL NOTES 1" ALLOW 14" GAP MIN. FOR EXPANSION, TYP. BOTH SIDES INTERIOR INSTALLATION EXTERIOR INSTALLATION FLAT RECESSED CLOSURE EXTERIOR INSTALLATION SECTION DETAIL AT ACUTE WALL ANGLES SCALE: 6" = 1'-0" 4 3 NOTE: ATTACHMENT TO STRUCTURE DESIGNED AND PROVIDED BY OTHERS, NOT BY HUNTER DOUGLAS SEE DETAIL 1/5 THIS SET, TABLE 1 FOR MAX O.C. SPACING REQUIREMENTS SECTION DETAIL AT ACUTE WALL ANGLES SCALE: 6" = 1'-0" NOTE: ATTACHMENT TO STRUCTURE DESIGNED AND PROVIDED BY OTHERS, NOT BY HUNTER DOUGLAS 5 3 SECTION DETAIL AT PANEL SEAMS 13 4 " J-TRIM, USE ANGLE ABOVE AS HOLD DOWN INSIDE PANEL IF REQUIRED ATTACHMENT TO STRUCTURE DESIGNED AND PROVIDED BY OTHERS, NOT BY HUNTER DOUGLAS 3. Return approved shop drawings to Hunter Douglas to release for fabrication. 4. All quantities are to be reviewed and approved by the customer prior to fabrication. 5. This material list is an ESTIMATE ONLY. The customer is responsible for reviewing and verifying ALL information listed above prior to ordering material. Excess material will not be accepted for returns or credit. If additional material is necessary, set-up charges may apply. 6. Unless shown otherwise, all penetrations including light fixtures, diffusers, speakers, sprinkler heads, etc., are to be field located and field cut. Hunter Douglas will not be responsible for final location and placement of penetrations. Typically, penetrations are not dimensioned or located on Hunter Douglas shop drawings unless the holes are factory cut. All "fixtures" are to be independently supported. Trim for all penetrations are by others. Any fixture or other penetration shown is soley based on information provided to Hunter Douglas. 7. Architect / General Contractor: Please reference appropriate contract documents for coordination with other trades. 8. If there are any questions in relation to Hunter Douglas products on this project, please contact us at 1-800-366-4327 (8:00am - 5:00pm EST Monday-Friday). 1-34" 'J' TRIM All rights reserved. This drawing is the property of Hunter Douglas. It may not be copied or multiplied, neither wholly nor partly. It may not be submitted for perusal to third parties. 6" MAX CARRIER OVERHANG, SEE DETAIL 1/5 THIS SET, TABLE 1 FOR REQUIREMENTS VERTICAL SUPPORT DIETRICH STE-20 2-12" 20 GA GALV. STEEL STUD OR EQUAL, MAX LENGTH 85", SEE DETAIL 1/5 THIS SET, NOTE 3 FOR VERTICAL SUPPORT REQUIREMENTS TABLE 1 - INTERIOR OBTUSE TRIM CONDITIONS @ WALLS LINEAR BOX CEILING SYSTEM PANEL NUMBER VARIABLE ANGLE, SEE TABLE 6 ON THIS SHEET UNIVERSAL BOX CARRIER FIELD CUT & SPLICE TO FIT TYPICAL SECTION CONDITION ANGLE OF SLOPE WALL ANGLE (TOTAL ANGLE) TABLE 4 - EXTERIOR ACUTE TRIM CONDITIONS @ WALLS LINEAR BOX CEILING SYSTEM PANEL NUMBER DETAIL 1/3 P DETAIL 5/3 B DETAIL 2/3 S DETAIL 5/3 C DETAIL 2/3 T DETAIL 5/3 D DETAIL 2/3 U DETAIL 5/3 E DETAIL 2/3 V DETAIL 5/3 FF DETAIL 2/3 W DETAIL 5/3 JJ DETAIL 2/3 TABLE 2 - INTERIOR TRIM CONDITIONS @ SEAMS LINEAR BOX CEILING SYSTEM PANEL NUMBER FIELD CUT PANEL SIDE, BOX 6 SHOWN, ALL LINEAR BOX PANEL SIZE SIMILAR 1"X2" WALL ANGLE, USE ANGLE ABOVE AS HOLD DOWN INSIDE PANEL IF REQUIRED TYPICAL SECTION CONDITION A 1" FLAT RECESSED CLOSURE The purpose of these drawings is to represent installation of Hunter Douglas products ONLY. All dimensions are to be field verified and approved by the contractor prior to fabrication. 1" x 1" ANGLE INSIDE 'J' TRIM TO SECURE CUT PANEL EDGE ALLOW 14" GAP MIN. FOR EXPANSION, TYP. BOTH SIDES 12 GA HANGER WIRE, WITHIN 3" OF VERTICAL SUPPORT, TYP., NOT BY HUNTER DOUGLAS 2. DOUBLE SIDED ADHESIVE TAPE TO SECURE ANGLE NOTE: SCALE: 6" = 1'-0" Ceiling installation to be in accordance with ASTM C636 & ASTM E580, and local code requirements for seismic bracing. 1" FIELD CUT PANEL SIDE, BOX 6 SHOWN, ALL LINEAR BOX PANEL SIZE SIMILAR EXTERIOR INSTALLATION 4 3 1"X2" WALL ANGLE, USE ANGLE ABOVE AS HOLD DOWN INSIDE PANEL IF REQUIRED 1. TYPICAL SECTION CONDITION F DETAIL 3/3 G DETAIL 3/3 H DETAIL 3/3 ANGLE OF SLOPE WALL ANGLE (TOTAL ANGLE) TABLE 5 - EXTERIOR CONDITIONS @ SEAMS LINEAR BOX CEILING SYSTEM PANEL NUMBER ANGLE OF SLOPE WALL ANGLE (TOTAL ANGLE) TYPICAL SECTION CONDITION X DETAIL 6/3 Y DETAIL 6/3 ANGLE OF SLOPE WALL ANGLE (TOTAL ANGLE) REVISIONS: TABLE 6 - EXTERIOR OBTUSE TRIM CONDITIONS @ WALLS LINEAR BOX CEILING SYSTEM J DETAIL 3/3 K DETAIL 3/3 PANEL NUMBER L DETAIL 3/3 Q DETAIL 7/3 R DETAIL 7/3 TYPICAL SECTION CONDITION 1. - DATE BY - - ANGLE OF SLOPE WALL ANGLE (TOTAL ANGLE) TABLE 3 - INTERIOR ACUTE TRIM CONDITIONS @ WALLS LINEAR BOX CEILING SYSTEM PANEL NUMBER EXTERIOR INSTALLATION TYPICAL SECTION CONDITION HH DETAIL 4/3 CC DETAIL 4/3 KK DETAIL 4/3 ANGLE OF SLOPE WALL ANGLE (TOTAL ANGLE) DRAWN BY: A PRICE CHECKED BY: DATE: 8/15/14 PAGE SIZE: 36" x 48" (ARCH "E") PROJECT: SHAKE SHACK - LAS VEGAS CUSTOMER: PAGE TITLE: INTERIOR/EXTERIOR BOX 6 DETAILS AND TRIM ANGLE CHARTS DRAWING NUMBER: 441181-3 6 3 SECTION DETAIL AT OBTUSE WALL ANGLES SCALE: 6" = 1'-0" NOTE: ATTACHMENT TO STRUCTURE DESIGNED AND PROVIDED BY OTHERS, NOT BY HUNTER DOUGLAS 9 3 CHARTS FOR ANGLE OF WALL ANGLES SCALE: NOT TO SCALE NOTE: ATTACHMENT TO STRUCTURE DESIGNED AND PROVIDED BY OTHERS, NOT BY HUNTER DOUGLAS SHEET: 3 OF 5 SCALE: AS SHOWN SIDE VIEW OF UNIVERSAL CARRIER WITH PANEL 1 Hunter Douglas Circle 5015 Oakbrook Parkway, Suite 100 Thornton, CO 80241 Norcross, GA 30093 866-556-1235 800-366-4327 / 770-806-9557 fax: 720-872-7850 fax: 770-806-0214 48" MAX O.C. CARRIER SPACING SCALE: 3" = 1'-0" www.hunterdouglascontract.com 12" MAX PANEL OVERHANG, TYP. BOTH ENDS R 12 GA HANGER WIRE, TYP., NOT BY HUNTER DOUGLAS END VIEW OF UNIVERSAL CARRIER WITH PANEL M E T A L C E I L I N G S SCALE: 3" = 1'-0" 1-34" 'J' TRIM R W O O D C E I L I N G S UNIVERSAL CARRIER R FACTORY PANEL END, BOX 6 SHOWN, ONLY STANDARD LINEAR BOX SIMILAR 1-34" 'J' TRIM BOX 6 PANEL FIELD CUT PANEL END, BOX 6 SHOWN, ONLY STANDARD LINEAR BOX SIMILAR A C O U S T I C A L C E I L I N G S SUPPLEMENTAL CARRIER FOR 'J' TRIM ATTACHMENT, TYP. BOTH ENDS UNIVERSAL CARRIER* SUSPENSION SPECIFICATIONS MATERIAL: 0.040" ALUMINUM FINISH: MATTE BLACK PART LENGTH: 16'-0" *CARRIER SPLICE REQUIRED, SEE DETAIL A1.5 UNIVERSAL CARRIER SCALE: NOT TO SCALE INTERIOR INSTALLATION 1 4 SUSPENSION SPECIFICATIONS SCALE: NOT TO SCALE INTERIOR INSTALLATION 4 4 NOTE: ATTACHMENT TO STRUCTURE DESIGNED AND PROVIDED BY OTHERS, NOT BY HUNTER DOUGLAS SECTION AT HD LINEAR BOX CEILING TERMINATION NOTE: SCALE: 3" = 1'-0" ATTACHMENT TO STRUCTURE DESIGNED AND PROVIDED BY OTHERS, NOT BY HUNTER DOUGLAS INTERIOR INSTALLATION PROJECT SPECIFIC NOTES BOX 6 PANEL BOX 6 PANEL SPLICE 48" MAX O.C. SPACING FOR CARRIER SPAN BOX 6 PANEL 12" MAX CARRIER OVERHANG, TYP. BOTH ENDS NO CLOSURE AT INTERIOR 12 GA HANGER WIRE, TYP., NOT BY HUNTER DOUGLAS BOX 6 PANEL FLAT RECESSED CLOSURE OPTIONAL GENERAL NOTES UNIVERSAL CARRIER UNIVERSAL CARRIER NOTE 1: DO NOT SPLICE PANELS DIRECTLY BELOW UNIVERSAL CARRIERS. PANEL SPLICES DO NOT FIT UNDER CARRIERS. 1" WALL ANGLE NOTE 2: FIELD CUT PANELS AS REQUIRED TO CREATE A RANDOM STAGGERED SEAM PATTERN. AVOID ALIGNED SEAMS. BOX 6 PANEL SPLICE FACTORY PANEL SIDE, BOX 6 SHOWN, ALL LINEAR BOX PANEL SIZE SIMILAR FIELD CUT PANEL SIDE, BOX 6 SHOWN, ALL LINEAR BOX PANEL SIZE SIMILAR 1. Ceiling installation to be in accordance with ASTM C636 & ASTM E580, and local code requirements for seismic bracing. 2. The purpose of these drawings is to represent installation of Hunter Douglas products ONLY. All dimensions are to be field verified and approved by the contractor prior to fabrication. 3. Return approved shop drawings to Hunter Douglas to release for fabrication. 4. All quantities are to be reviewed and approved by the customer prior to fabrication. 5. This material list is an ESTIMATE ONLY. The customer is responsible for reviewing and verifying ALL information listed above prior to ordering material. Excess material will not be accepted for returns or credit. If additional material is necessary, set-up charges may apply. 6. Unless shown otherwise, all penetrations including light fixtures, diffusers, speakers, sprinkler heads, etc., are to be field located and field cut. Hunter Douglas will not be responsible for final location and placement of penetrations. Typically, penetrations are not dimensioned or located on Hunter Douglas shop drawings unless the holes are factory cut. All "fixtures" are to be independently supported. Trim for all penetrations are by others. Any fixture or other penetration shown is soley based on information provided to Hunter Douglas. 7. Architect / General Contractor: Please reference appropriate contract documents for coordination with other trades. 8. If there are any questions in relation to Hunter Douglas products on this project, please contact us at 1-800-366-4327 (8:00am - 5:00pm EST Monday-Friday). 1" WALL ANGLE, USE ANGLE ABOVE AS HOLD DOWN INSIDE PANEL IF REQUIRED UNIVERSAL CARRIER BEYOND PANEL SEAM UNIVERSAL CARRIER BOX 6 PANEL SECTION 'A' SCALE: 3" = 1'-0" SECTION 'B' BOX 6 PANEL SPLICE, WILL NOT FIT UNDER UNIVERSAL CARRIER SCALE: 3" = 1'-0" BOX 6 PANEL SPLICE, WILL NOT FIT UNDER UNIVERSAL CARRIER BOX 6 PANEL *HANGER WIRE OMITTED FOR CLARITY 2 4 PANEL SPLICES DETAILS SCALE: 3" = 1'-0" INTERIOR INSTALLATION 5 4 NOTE: ATTACHMENT TO STRUCTURE DESIGNED AND PROVIDED BY OTHERS, NOT BY HUNTER DOUGLAS SECTION AT HD LINEAR BOX CEILING TERMINATION NOTE: SCALE: 3" = 1'-0" ATTACHMENT TO STRUCTURE DESIGNED AND PROVIDED BY OTHERS, NOT BY HUNTER DOUGLAS INTERIOR INSTALLATION All rights reserved. This drawing is the property of Hunter Douglas. It may not be copied or multiplied, neither wholly nor partly. It may not be submitted for perusal to third parties. UNIVERSAL CARRIER SPLICE UNIVERSAL CARRIER LATERAL BRACING: BRACE WITH HANGER WIRES AND STRUTS PER ASTM E-580 AND IN ACCORDANCE WITH LOCAL CODE REQUIREMENTS. UNIVERSAL CARRIER SECTION 'A' BOX 6 PANEL 'B' 'B' UNIVERSAL CARRIER SPLICE STRUT FASTENED TO MAIN RUNNER SHALL BE EXTENDED TO AND FASTENED TO STRUCTURE ABOVE. SPLAYED WIRE AND STRUT BRACING TO BE PLACED NOT MORE THAN 12 FEET ON CENTER IN EACH DIRECTION, WITH FIRST POINT WITHIN 4 FEET FROM EACH WALL. E BOX 6 PANEL COMPRESSION STRUT/ VERTICAL SUPPORT N E SCALE: 3" = 1'-0" N IF THE DESIRED CARRIER LENGTH EXCEEDS THE MAXIMUM OF 16'-0", USE A LUXALON CARRIER SPLICE TO CONNECT THE FACTORY CARRIER ENDS. SNAP SPLICE TABS INTO UNIVERSAL CARRIER S W THE TABS OF THE SPLICE SNAP INTO THE HOLES IN THE CARRIER AND ADDITIONAL FIXING IS NOT NECESSARY. THE MODULE IS CONTINUED AUTOMATICALLY. S REVISIONS: W 1. - DATE BY - - FIELD DRILL HOLES IN UNIVERSAL CARRIER AS NEEDED TO ALLOW FOR THE FOUR SPLAYED HANGER WIRES AS SHOWN UNIVERSAL CARRIER BOX 4 PANEL SHOWN, ALL LINEAR BOX SIMILAR SECTION 'B' DRAWN BY: A PRICE CHECKED BY: DATE: 8/12/14 PAGE SIZE: 36" x 48" (ARCH "E") PROJECT: SHAKE SHACK - LAS VEGAS SCALE: FULL (1:1) CUSTOMER: PAGE TITLE: INTERIOR BOX 6 DETAILS INTERIOR INSTALLATION DRAWING NUMBER: 441181-4 SHEET: 4 *HANGER WIRE OMITTED FOR CLARITY OF 5 3 4 CARRIER SPLICE DETAIL SCALE: NOT TO SCALE INTERIOR INSTALLATION NOTE: ATTACHMENT TO STRUCTURE DESIGNED AND PROVIDED BY OTHERS, NOT BY HUNTER DOUGLAS 3 4 ISOMETRIC VIEW OF HD LINEAR BOX SEISMIC DETAIL SCALE: NOT TO SCALE INTERIOR INSTALLATION NOTE: ATTACHMENT TO STRUCTURE DESIGNED AND PROVIDED BY OTHERS, NOT BY HUNTER DOUGLAS SCALE: 3" = 1'-0" NOTE A: CARRIER SPACING (PANEL SPAN) AND CARRIER SPAN (HANGER WIRE & VERTICAL SUPPORT SPACING) VARIES DEPENDING ON DESIGN WIND PRESSURE (POUNDS PER SQUARE FOOT). AS A GENERAL GUIDE, REFER TO THE DETAIL AND WIND LOAD TABLE 1 BELOW FOR CARRIER SPACING AND CARRIER SPAN. THE WIND LOAD CRITERIA IS BASED ON USING 3 OR MORE ROWS OF CARRIER. MAXIMUM PANEL OVERHANG = 6". MAXIMUM CARRIER OVERHANG = 6". UNIVERSAL CARRIER, .040" ALUMINUM VERTICAL SUPPORT 1/2" X 1-1/2" 16 GA GALV. CRC , MAX LENGTH 28", SEE DETAIL 2/5 THIS SHEET FOR VERTICAL SUPPORT REQUIREMENTS AND EQUALS SEE TABLE 1 ON DETAIL 1/5 THIS SHEET FOR MAX O.C. SPACING REQUIREMENTS, TYPICAL 1 Hunter Douglas Circle 5015 Oakbrook Parkway, Suite 100 Thornton, CO 80241 Norcross, GA 30093 866-556-1235 800-366-4327 / 770-806-9557 fax: 720-872-7850 fax: 770-806-0214 12 GA HANGER WIRE, WITHIN 3" OF VERTICAL SUPPORT, TYPICAL, NOT BY HUNTER DOUGLAS HANGER WIRE (12 GA MIN.) MUST BE LOCATED AT EACH VERTICAL SUPPORT STRUT. VERTICAL SUPPORT STRUT MUST NOT EXCEED SPACING SHOWN FOR A GIVEN DESIGN WIND PRESSURE. SEE DETAIL 2/5 THIS SHEET FOR VERTICAL SUPPORT SPECIFICATION. HANGER WIRE AND VERTICAL SUPPORT STRUT MUST BE ATTACHED TO STRUCTURE ABOVE TO SAFELY SUPPORT ALL LOADS IMPOSED BY SOFFIT SYSTEM. ATTACHMENT TO STRUCTURE DESIGNED AND PROVIDED BY OTHERS, NOT BY HUNTER DOUGLAS. www.hunterdouglascontract.com 6" MAX AT CARRIER SPLICE, TYPICAL VERTICAL SUPPORT 1/2" X 1-1/2" 16 GA GALV. CRC OR EQUAL, MAX LENGTH 28", SEE NOTE A ON DETAIL 2/5 THIS SHEET FOR VERTICAL SUPPORT REQUIREMENTS NOTE B: ALL PENETRATIONS IN CEILING TO BE FIELD LOCATED AND FIELD CUT. TRIM FOR THESE ITEMS NOT BY HUNTER DOUGLAS. NOTE C: ATTACHMENT TO STRUCTURE DESIGNED AND PROVIDED BY OTHERS, NOT BY HUNTER DOUGLAS. 'B' UNIVERSAL CARRIER SPLICE UNIVERSAL CARRIER R M E T A L 'B' SECTION 'A' BOX 6 PANEL C E I L I N G S FLAT RECESSED CLOSURE R SCALE: 3" = 1'-0" W O O D C E I L I N G S R TABLE 1 - DESIGN WIND LOAD - LINEAR BOX EXTERIOR CEILING SYSTEM A C O U S T I C A L SNAP SPLICE TABS INTO UNIVERSAL CARRIER PANEL TYPE: .025", .032", OR .040" ALUMINUM, BOX 6 PANEL CARRIER TYPE: .040" ALUMINUM, UNIVERSAL CARRIER C E I L I N G S ALLOWABLE CARRIER SPACING (PANEL SPAN) ALLOWABLE CARRIER SUPPORT SPACING (HANGER WIRE/VERTICAL SUPPORT SPACING) BOX 6 PANEL, .025", .032", OR .040" ALUMINUM REQUIRED FOR EXTERIOR * NOTE: CARRIER SPACING BASED ON USING 3 OR MORE CARRIERS ** POUNDS PER SQUARE FOOT DESIGN WIND PRESSURE (POSITIVE OR NEGATIVE PSF**) FLAT RECESSED CLOSURE REQUIRED FOR EXTERIOR INSTALLATION 1 5 SUSPENSION SPECIFICATIONS CARRIER SPACING * (PANEL SPAN) CARRIER SPAN (VERTICAL SUPPORT SPACING) 20 2'-8" 2'-2" 25 2'-5" 2'-1" 30 2'-2" 1'-11" 35 2'-0" 1'-10" 40 1'-11" 1'-9" 45 1'-10" 1'-9" NOTE: SCALE: NOT TO SCALE ATTACHMENT TO STRUCTURE DESIGNED AND PROVIDED BY OTHERS, NOT BY HUNTER DOUGLAS EXTERIOR INSTALLATION PROJECT SPECIFIC NOTES NOTE A: DIETRICH STE-20 2-1/2" 20 GA GALV. STEEL STUD 12 GA HANGER WIRE, WITHIN 3" OF VERTICAL SUPPORT, NOT BY HUNTER DOUGLAS 1/2" X 1-1/2" 16 GA GALV. CRC 12 GA HANGER WIRE, WITHIN 3" OF VERTICAL SUPPORT, TYPICAL, NOT BY HUNTER DOUGLAS VERTICAL SUPPORT STRUTS (MINIMUM 1-1/2" 16 GA GALV. 'C' CHANNEL OR EQUAL, MAX LENGTH OF 28"). SEE DETAIL 1/5 THIS SHEET FOR EXTERIOR SUSPENSION REQUIREMENTS. VERTICAL SUPPORTS SHALL BE LOCATED WITHIN 6" OF THE ENDS OF EACH CARRIER AND WITHIN 6" ON BOTH SIDES OF A CARRIER SPLICE. 12 GA (.109") MIN X 3/4" WIDTH MIN VERTICAL SUPPORT EQUALS: 1/2" X 1-1/2" 16 GA GALV. CRC SECURED TO CARRIER WITH 12 GA GALV. BRACKET, NOT BY HUNTER DOUGLAS UNIVERSAL CARRIER 12 GA GALV. BRACKET, NOT BY HUNTER DOUGLAS DIETRICH STE-20 2-1/2" 20 GA GALV. MAX LENGTH OF 85" 1/2" MAX *** ATTACHMENT TO STRUCTURE ABOVE SHALL BE DESIGNED AND PROVIDED BY OTHERS TO SUPPORT ALL LOADS IMPOSED BY CEILING SOFFIT SYSTEM *** UNIVERSAL CARRIER DIETRICH TRNB-25 MAX LENGTH OF 78" BOX 6 PANEL 1" MIN UNIVERSAL CARRIER SPLICE GENERAL NOTES FLAT RECESSED CLOSURE OR BOX 6 PANEL FLAT RECESSED CLOSURE 1/4" DIAMETER X 20 GRADE 2 NUT & BOLT IN PREPUNCHED CARRIER HOLE, NOT BY HUNTER DOUGLAS 12 GA BRACKET GALV., NOT BY HUNTER DOUGLAS NOTE A: ATTACHMENT TO STRUCTURE DESIGNED AND PROVIDED BY OTHERS, NOT BY HUNTER DOUGLAS 2 5 17" 32 BOX 6 PANEL, .025", .032", OR .040" ALUMINUM REQUIRED FOR EXTERIOR VERTICAL SUPPORT 1/2" X 1-1/2" 16 GA GALV. CRC, MAX LENGTH 28", SEE NOTE A THIS SHEET FOR VERTICAL SUPPORT REQUIREMENTS 12 GA HANGER WIRE, WITHIN 3" OF VERTICAL SUPPORT, NOT BY HUNTER DOUGLAS VERTICAL SUPPORT DIETRICH STE-20 2-1/2" 20 GA GALV. STEEL STUD OR EQUAL, MAX LENGTH 85", SEE NOTE A THIS SHEET FOR VERTICAL SUPPORT REQUIREMENTS (2) NO. 10 TEK SCREWS, NOT BY HUNTER DOUGLAS (2) NO. 10 TEK SCREWS, NOT BY HUNTER DOUGLAS IF THE DESIRED CARRIER LENGTH EXCEEDS THE MAXIMUM OF 16'-0", USE A UNIVERSAL CARRIER SPLICE TO CONNECT THE FACTORY CARRIER ENDS. THE TABS OF THE SPLICE SNAP INTO THE HOLES IN THE CARRIER AND ADDITIONAL FIXING IS NOT NECESSARY. THE MODULE IS CONTINUED AUTOMATICALLY. 5" 532 SECTION 'A' 27" 32 UNIVERSAL CARRIER, .040" ALUMINUM SCALE: NOT TO SCALE EXTERIOR INSTALLATION ITEM # 3. Return approved shop drawings to Hunter Douglas to release for fabrication. 4. All quantities are to be reviewed and approved by the customer prior to fabrication. 5. This material list is an ESTIMATE ONLY. The customer is responsible for reviewing and verifying ALL information listed above prior to ordering material. Excess material will not be accepted for returns or credit. If additional material is necessary, set-up charges may apply. 6. Unless shown otherwise, all penetrations including light fixtures, diffusers, speakers, sprinkler heads, etc., are to be field located and field cut. Hunter Douglas will not be responsible for final location and placement of penetrations. Typically, penetrations are not dimensioned or located on Hunter Douglas shop drawings unless the holes are factory cut. All "fixtures" are to be independently supported. Trim for all penetrations are by others. Any fixture or other penetration shown is soley based on information provided to Hunter Douglas. 7. Architect / General Contractor: Please reference appropriate contract documents for coordination with other trades. 8. If there are any questions in relation to Hunter Douglas products on this project, please contact us at 1-800-366-4327 (8:00am - 5:00pm EST Monday-Friday). SCALE: 3" = 1'-0" 4 5 CARRIER SPLICE DETAILS NOTE: SCALE: NOT TO SCALE ATTACHMENT TO STRUCTURE DESIGNED AND PROVIDED BY OTHERS, NOT BY HUNTER DOUGLAS EXTERIOR INSTALLATION All rights reserved. This drawing is the property of Hunter Douglas. It may not be copied or multiplied, neither wholly nor partly. It may not be submitted for perusal to third parties. BILL OF MATERIALS HUNTER DOUGLAS LINEAR BOX 6 CEILING SYSTEM - INTERIOR FINISH: #9125, HEMLOCK WOOD VENEER PERFORATION: NONE PANEL BACKING: NONE MATERIAL: .025" ALUMINUM DESCRIPTION SIZE QUANTITY BOX 6 LINEAR PANEL - FINISH: AS ABOVE 16'-0" PANELS WITH FINGER JOINT 10'-0" PANELS WITHOUT FINGER JOINT PANEL SPLICE - FINISH: BLACK 16'-0" 10'-0" N/A 365 583 365 OR 583 UNIVERSAL CARRIER - FINISH: BLACK UNIVERSAL CARRIER SPLICE 16'-0" N/A 63 63 1x1 WALL ANGLE - .025" ALUMINUM ANGLE A 10'-0" 6 1x2 WALL ANGLE - .025" ALUMINUM - OBTUSE ANGLE - FINISHED: TO BE DETERMINED 10'-0" 8 10'-0" 4 10'-0" 5 ANGLE E - 100.46 10'-0" 5 10'-0" 1 10'-0" 1 1x2 WALL ANGLE - .025" ALUMINUM - ACUTE ANGLE - FINISHED: TO BE DETERMINED 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 4 6 7 3 3 3 1 1 1 1-3/4" 'J' TRIM - .025" ALUMINUM - FINISHED: TO BE DETERMINED ANGLE F ANGLE G ANGLE H ANGLE J ANGLE K ANGLE L 4 6 7 3 3 3 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" ***QUANTITIES CONTAIN ZERO OVERAGE- ADD AS REQUIRED FOR ATTIC STOCK, ETC. BEFORE PRODUCTION*** ITEM # 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20 21. 22 23 24. 25. 26. 27 28. 29. 31. 32. 33. 34. 35. 36. 37. BILL OF MATERIALS HUNTER DOUGLAS LINEAR BOX 6 CEILING SYSTEM - EXTERIOR FINISH: #8486, DECORATED NORTHWEST MOUNTAIN HEMLOCK PERFORATION: NONE PANEL BACKING: NONE MATERIAL: .025" ALUMINUM DESCRIPTION SIZE QUANTITY BOX 6 LINEAR PANEL - FINISH: AS ABOVE PANEL SPLICE - FINISH: BLACK RECESSED CLOSURE - FINISH: BLACK 16'-0" N/A 12'-0" 151 151 202 UNIVERSAL CARRIER - FINISH: BLACK UNIVERSAL CARRIER SPLICE 16'-0" N/A 37 37 1x2 WALL ANGLE - .025" ALUMINUM - OBTUSE ANGLE - FINISHED: TO BE DETERMINED 10'-0" 11 10'-0" 8 1x2 WALL ANGLE - .025" ALUMINUM - ACUTE ANGLE - FINISHED: TO BE DETERMINED 10'-0" 10'-0" 10'-0" 10'-0" ANGLE V - 73.61 10'-0" 10'-0" 10'-0" 10'-0" 1-3/4" 'J' TRIM - .025" ALUMINUM - FINISHED: TO BE DETERMINED ANGLE X ANGLE Y 10'-0" 10'-0" 1 1 4 1 4 10 2 5 2 5 ***QUANTITIES CONTAIN ZERO OVERAGE- ADD AS REQUIRED FOR ATTIC STOCK, ETC. BEFORE PRODUCTION*** SHOP DRAWINGS - 441181 SHAKE SHACK - LAS VEGAS 8/15/14 N/A ITEM # 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20 21. 22 23 24. 25. 26. 27 28. 29. 31. 32. 33. 34. 35. 36. 37. HUNTER DOUGLAS LINEAR BOX 6 CEILING SYSTEM - HOLD DOWNS FINISH: ANY PERFORATION: NONE PANEL BACKING: NONE MATERIAL: .025" ALUMINUM DESCRIPTION SIZE QUANTITY 1x2 WALL ANGLE HOLD DOWN - .025" ALUMINUM - OBTUSE ANGLE - FINISHED: ANY 10'-0" 10'-0" 10'-0" ANGLE E - 100.46 10'-0" 10'-0" 10'-0" 8 4 5 5 1 1 1x2 WALL ANGLE HOLD DOWN - .025" ALUMINUM - ACUTE ANGLE - FINISHED: ANY 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 4 6 7 3 3 3 1 1 1 1x2 WALL ANGLE HOLD DOWN - .025" ALUMINUM - OBTUSE ANGLE - FINISHED: ANY 10'-0" 11 10'-0" 8 1x2 WALL ANGLE HOLD DOWN - .025" ALUMINUM - ACUTE ANGLE - FINISHED: ANY 10'-0" 10'-0" 10'-0" 10'-0" ANGLE V - 73.61 10'-0" 10'-0" 10'-0" 10'-0" 1 1 4 1 4 10 2 5 1X1 WALL ANGLE HOLD DOWN FOR J-TRIM - .025" ALUMINUM 33 N/A 5 SHEET(S) 10'-0" REVISIONS: 1. - DATE BY - - DRAWN BY: A PRICE CHECKED BY: DATE: 8/12/14 PAGE SIZE: 36" x 48" (ARCH "E") PROJECT: SHAKE SHACK - LAS VEGAS ***QUANTITIES CONTAIN ZERO OVERAGE- ADD AS REQUIRED FOR ATTIC STOCK, ETC. BEFORE PRODUCTION*** CUSTOMER: PAGE TITLE: EXTERIOR BOX 6 DETAILS & B.O.M. 5 SHEET(S) SHOP DRAWINGS - 441181 SHAKE SHACK - LAS VEGAS 8/15/14 SHOP DRAWINGS - 441181 SHAKE SHACK - LAS VEGAS 8/15/14 The purpose of these drawings is to represent installation of Hunter Douglas products ONLY. All dimensions are to be field verified and approved by the contractor prior to fabrication. SCALE: FULL (1:1) BILL OF MATERIALS 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20 21. 22 23 24. 25. 26. 27 28. 29. 31. 32. 33. 34. 35. 36. 37. 38. 2. FLAT RECESSED CLOSURE REQUIRED FOR EXTERNAL INSTALLATION NOTE B: ALL PENETRATIONS IN CEILING TO BE FIELD LOCATED AND FIELD CUT. TRIM FOR THESE ITEMS NOT BY HUNTER DOUGLAS. SUSPENSION SPECIFICATIONS SECTION 'B' 125 32" 6" Ceiling installation to be in accordance with ASTM C636 & ASTM E580, and local code requirements for seismic bracing. SEE TABLE 1 ON DETAIL 1/5 THIS SHEET FOR MAX O.C. SPACING REQUIREMENTS 114" (2) NO. 10 TEK SCREWS, NOT BY HUNTER DOUGLAS OR 1. N/A 5 SHEET(S) DRAWING NUMBER: 441181-5 SHEET: 5 OF 5 SCALE: AS SHOWN
© Copyright 2026 Paperzz