addendum 3 - Coleman Construction Ltd

Post Tender Addendum
Project Name:
Nation Municipality Garage
Project No.:
Issue Date:
2017-03-31
Client:
The Nation Municipality
Address:
958 RTE 500 West, Casselman Ontario
Attention:
Graham E Lancaster, P. Eng
Senior Manager, EXP Services Inc.
Addendum No.:
Phone:
2783
3
613-764-5444
The following addendum, clarification and revision items as they relate to the drawings and specifications previously issued are
noted.
1. Architectural additions and clarifications:
1.1 Drawings
A200, A201 & A202:
Revise wall assembly F1 - FOUNDATION WALL to the following:
·
76mm CONCRETE FACED RIGID INSULATION
·
POURED CONCRETE FOUNDATION WALL, REFER TO STRUCTURAL
Revise wall assembly F2X – EXTERIOR WALL TYPE 2 to the following:
·
PRE-FINISHED METAL SIDING, REFER TO ELEVATIONS FOR TYPE
·
114mm RIGID INSULATION
·
114mm HORIZONTAL SUB-GIRT
·
SELF ADHERED FLEXIBLE AIR / VAPOUR BARRIER MEMBRANE
·
16mm FIBREGLASS MAT GYPSUM PANELS
·
152mm STRUCTURAL STEEL STUDS
·
16mm GYPSUM BOARD
·
PAINT FINISH
A351 – WOMEN WASHROOM RM 205 & MEN WASHROOM RM 206
Revise PT in showers to PT1 and delete requirement for PT3.
1.2 Specifications
Dreessen Cardinal Architects Inc.
1350 Wellington St., West, Ottawa, ON K1Y 3C1
Page 1 of 3
2783 - ADDENDUM 33
Post Tender Addendum
Div. 01 74 21:
Delete sentence 1.6.6 and its requirements.
Div. 07 21 13:
Revise sentence 2.1.1.3 to the following:
Thickness: 76.2mm. (min. RSI 2.64)
Div. 07 46 13:
Revise section 2.1 to the following:
.1.1 Finish coating: 2 coat series 10,000 series finish Dry film thickness of 1.0 +/- mils
.1.2 Colour: ID 690 Maritime Grey
.1.4 Thickness: .66 mm base metal thickness.
.3.4 Thickness: .66 mm base metal thickness.
.4.4 Thickness: .66 mm base metal thickness.
Div. 08 71 00:
Revise sentence 1.3.4.2 to the following:
Obtain the services of a qualified Architectural Hardware Consultant (AHI), certified by the Door and
Hardware Institute to: develop hardware schedule. Cash allowance of $1,500 to be used.
Div. 08 36 13.02:
Revise sentence 2.1.12 to the following:
Color: Exterior, to be selected by architect from manufactures standard range of colours; Interior,
Manufacturer's standard White.
Revise sentence 2.4.1.3 to the following:
Motor: 3/4 HP, standard warranty. Confirm that door motor size is adequate for O/H door size and
weight. Remote push-button stations; flush mounted, with “open-Stop-Close” designation on
pushbuttons in English. Cable Control: pendent hung control to open, close and stop.
Div. 08 11 16: Revise sentence 2.6.1.1 to the following:
Clear anodic finish: clear anodic exterior, clear anodic interior.
Div. 09 30 13: Revise sentence 2.1 to the following:
WASHROOMS RM-108, RM-117, RM-118, RM-205 & RM-206
Div. 09 65 16: Revise section 2.1 to include the following:
Static Dissipative Tile:
Manufacturer: Armstrong
Texture: Imperial
Series: Standard Excelon
Colour: Pearl White #51953
Size: 305mm x 305mm
Dreessen Cardinal Architects Inc.
1350 Wellington St., West, Ottawa, ON K1Y 3C1
Page 2 of 3
2783 - ADDENDUM 3
Post Tender Addendum
Derek Ruddy
Digitally signed by Derek Ruddy
DN: cn=Derek Ruddy, o=Dreessen Cardinal Architects
Inc., ou, [email protected], c=CA
Date: 2017.03.31 15:10:41 -04'00'
Issued by: Derek Ruddy, Lic. Tech. OAA, Dreessen Cardinal Architects Inc.
Dreessen Cardinal Architects Inc.
1350 Wellington St., West, Ottawa, ON K1Y 3C1
Page 3 of 3
2783 - ADDENDUM 3