B38P High flow filter/regulator (stainless steel) 1/4 NPT, 3/8 NPT, G1/4 or G3/8 High flow filter/regulator designed for use in corrosive environment Metallic parts meet NACE* Standard MR-01-75 Applications include marine environment, oil and gas productions * National Association of Corrosion Engineers – recognised oil-field recommendation for resistance to sulphide stress cracking common in well-head and other corrosive environments Technical features Port sizes: 1/4 NPT, 3/8 NPT, G1/4 or G3/8 1/4 PTF (gauge) and 1/4 NPT (automatic drain) Drain: Manual or automatic Automatic drain operation conditions (float operated): To close: > 0,3 bar (4,35 psi) To open: < 0,2 bar (2,9 psi) Minimum air flow required to close 1 dm3/s Medium: Compressed air only Maximum inlet pressure: 31 bar (449 psi) (manual drain) 17 bar (246 psi)(autodrain) Outlet pressure range: 0,5 ... 10 bar (7,25 ... 145 Psi) Flow: 40 dm3/s Element: 5, 25 or40 μm Fluid/Ambient temperature: -20 ... +80°C (-4 ... +176°F) (FKM seals) -40 ... +80°C (-40 ... +176°F) (NBR seals) Air supply must be dry enough to avoid ice formation at temperatures below +2°C(+35°F). Materials: Body, bowl, bonnet, filter element and adjusting screw: 316 stainless steel Elastomers: FKM or NBR Technical data, standard model, relieving and panel nut Symbol Port size Outlet pressure *1) (bar) Element (μm) Flow *2) (dm3/s) Drain Weight (kg) Model 1/4 NPT 0,5 ... 10 5 40 Manual 1,61 B38P-254-B1MA 3/8 NPT 0,5 ... 10 5 40 Manual 1,60 B38P-354-B1MA 1/4 NPT 0,5 ... 10 5 40 Automatic 1,74 B38P-254-A1MA 3/8 NPT 0,5 ... 10 5 40 Automatic 1,73 B38P-354-A1MA *1) Outlet pressure can be adjusted to pressures in excess of, and less than, those specified. Do not use these units to control pressures outside of the specified ranges. *2) Typical flow with 10 bar inlet pressure, 6,3 bar set pressure and a 1 bar drop from set. Option selector Port size * B38P-˙˙4-˙˙M˙ Substitute Thread form 1/4” 2 NPT 3/8” 3 ISO G parallel Temperature range -20 ... +80°C (FKM seals) -40 ... +80°C (NBR seals) * 1/2” port size on request 11/13 2011-A8168c Substitute Substitute A Element G Substitute 5 5 µm 1 4 25 µm 2 Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. © 2013 Norgren China 40 µm 3 Drain Substitute Automatic A Manual short bowl B N/en/en 8.530.350.01 B38P Flow characteristics Inlet pressure: 10 bar, filter element: 5 µm, port size: 1/4 NPT bar Outlet pressure 8 8,0 bar 6 6,3 bar 4 4,0 bar 2 0 2,5 bar 0 10 20 30 dm3/s 40 Flow Regulating characteristics P2 (bar) Regulation 10 % flow 8 bar (0,7 dm3/s) 6 6,3 bar (0,56 dm3/s) 4 4 bar (0,37 dm3/s) 2 1 2 3 4 8 bar (7 dm3/s) 6 6,3 bar (5,6 dm3/s) 4 4 bar (3,7 dm3/s) 2 2,5 bar (0,25 dm3/s) 0 Regulation 100 % flow 8 Outlet pressure Outlet pressure 8 0 P2 (bar) 5 6 7 8 9 10 P1(bar) 0 2,5 bar (2,5 dm3/s) 0 1 2 Inlet pressure 3 4 6 7 8 9 10 P1(bar) 11/13 Inlet pressure Accessories Panel nut Neck mounting bracket Gauge *1) Plastic adjusting knob 5988-02 18-001-973 (includes panel nut) 18-013-913 (0 ... 6 bar, -40 ... 65°C) 74630-04 18-013-909 (0 ... 10 bar, -40 ... 65°C) *1) Stainless steel items not strictly to NACE standard MR-01-75. Spare parts Filter element Reparatursatz Filter element A080823-01 *2) 5 µm: 5984-01 A080823-03 *3) 25 µm: A080874-02 A080823-02 *4) 40 µm: A080874-03 A080823-04 *5) *2) manual drain, FPM *3) manual drain, NBR *4) auto drain, FPM *5) auto drain, NBR N/en/en 8.530.350.02 Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. © 2013 Norgren China 2011-A8168c B38P Dimensions Dimensions shown in mm Manual drain Projection/First angle 0 ... 6 0 ... 6 Auto drain ø38 55 200 48 1 172 # 135 113 # 48 1 55 117 ø38 2 117 2 13 8,5 63 25 63 1/4 NPT # Minimum clearance required to remove bowl 1 1/4 PTF Gauge port 2 1/8 PTF Exhaust port 13 63 63 Neck mounting bracket 75 25 8,5 1,5 35 54 65 38 6,5 41 Warning These products are intended for use in industrial compressed air systems only. Do not use these products where pressures and temperatures can exceed those listed under »Technical features«. Before using these products with fluids other than those specified, for non-industrial applications, life-support systems, or other applications not within published specifications, consult NORGREN. Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. 11/13 2011-A8168c The system designer is warned to consider the failure modes of all component parts used in pneumatic systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure. System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided. System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products. Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. © 2013 Norgren China N/en/en 8.530.350.03
© Copyright 2026 Paperzz