The Way - VSSI.com

The
Way
It’s a Better Way to Weigh!
Instruction Manual
Table of Contents
Pre-Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Parts Identification . . . . . . . . . . . . . . . . . . . . . . . . 3
Assembly & Installation . . . . . . . . . . . . . . . . . . . 3-4
Post Mounted Display . . . . . . . . . . . . . . . . . . . . . . 5
Features/Operation. . . . . . . . . . . . . . . . . . . . . . . . 6
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Care & Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Product Warranty . . . . . . . . . . . . . . . . . . . . . . . . . 8
TM
Pre-Installation
Thank you for purchasing
The VSSI Way ™ Scale!
NOTE:
Open packages carefully. Please inspect
the shipping cartons and contents for
any visible damage. This is important in
the event that any breakage has occurred
during transit.
PLEASE SAVE ALL
PACKAGING
UNTIL CERTAIN
YOU ARE SATISFIED
WITH THE PRODUCT
The VSSI Way ™ platform scale is
contained within two boxes. Below is
a list of everything you should receive:
• The VSSI Way ™ platform scale base
• 1 ribbed vinyl platform mat
• The VSSI Way ™ display/readout box
with mounting bracket
• 1 AC adapter power cord
• 1 stainless steel scale cover
Refer to the drawing on the next page to
identify parts.
Specifications
Platform Size:
Maximum Capacity:
44" x 22" x 2 5/8" tall
300 pounds
Accuracy:
Within 0.2% at 300 pounds
Electrical:
Operates on standard 110 VAC
or one 9-volt DC battery
Shipping Weight:
45 pounds
Display Mount Post Height: 36"
2
Parts Identification
Wall Mount
Bracket
No. 310-0110-00
Ribbed Vinyl
Platform Mat
No. 210-0117-01
The VSSI Way ™
Display/Readout
No. 735-0001-00
Platform Scale Top
No.619-0032-00
Display Support Post
(Optional)
No. 210-0117-02
AC Adapter
No. 703-0000-20
THIS E
SID P
U
TM
The VSSI Way ™
Platform Scale Base
No.310-2110-02
Assembly & Installation
If assembling a scale purchased with the optional post mount
for the display panel, go to “Post Mounted Displays”, page 5,
for Post Mount installation instructions.
1. Place the scale on a flat, level surface
with no less than 1" clearance on
each side. We do not recommend
recessing the scale into the floor.
Tip the scale on end and locate the
phone jack, with phone cord coming
out of the side.
Phone Jack
2. The side of the scale with the display
cord plug-in should be placed nearest
to the wall. Be sure the scale is level
continued
3
Assembly & Installation
Note: Always keep the readout display
matched to its proper base. If
multiple scales have been purchased, match the serial number
that is on the back of the display
with the same serial number
found on the phone jack.
after positioning. Screw-in feet on the
bottom of the scale base may be
adjusted as necessary.
3. Plug the end of the phone jack cord
into the jack marked “Base” on the
back side of the scale display. If you
purchased a secondary display, plug
the additional cord into the jack
marked “Remote” on the back side
of the main display and connect the
other end to the back of the second
ary display.
Remote
Cord
Plug-In
4. If you are using AC power to operate
the scale, you may now plug the
power cord into the back of the
display panel, and plug the AC
adapter into a standard wall outlet.
5. Mount the wall bracket
securely to the wall
(or counter) with
appropriate hardware
(not supplied).
See suggestions for
mounting hardware
at right. Suggested
height for the
mounting bracket
is 48” to 60"
from the floor.
continued
A/C
Adapter
Plug-In
Base
Cord
Plug-In
Back view of Display/Readout
Display
Wall
Wall
Toggle
Wall
Anchor
6. Press the “ON/ZERO” button.
Operating The VSSI Way ™ scale with
battery power requires one 9-volt battery.
The scale ships with a battery installed.
To replace the battery, refer to the
drawing at right. To perform an AC/DC
switch see page 6.
4
Post Mounted Displays
1. The display cord and AC adapter cord
should be threaded through the post
mount column. Start at the bottom of
the column and thread the cords up
through the top.
2. Place the scale base in the desired
location. Tip the scale up and locate
the corner you wish to install the
post mount on.
Display
Support Post
3. Next install the post mount as shown
at right by first removing the leveling
foot. Use the leveling foot and hex
bolt provided to attach the post
mount to the scale platform.
Note: The scale will now be uneven.
The remaining three feet must be
adjusted to match the foot inserted
in the post mount.
Spacer Plate
No. 610-0392-00
Washer
No. 819-2500-01
Hex Head Bolt
No. 816-2510-02
Leveling Foot
No. 810-0000-00
4. Fasten the scale display box to the
top of the mount post with the two
Phillips head screws. Plug the
display connector cord and AC
adapter cord coming from the top
of the mount post into the back of
the display. (See page 4)
Phillips Head Screw (2 places)
No. 815-1005-00
Note: Always keep the display matched
to its proper base. If multiple
scales have been purchased,
match the serial number on
the back of the display with
the same serial number found
on the phone jack.
The VSSI Way ™
Display/Readout
Display
Support Post
6. If using AC power to operate the
scale, plug the power cord into the
back of the display panel, and plug
the AC adapter into a standard wall
outlet. If operating the scale with
battery power see pages 4 and 6.
7. Press the “ON/ZERO” button.
5
Scale Features/Operation
Using The Control Panel:
ON
ZERO
LB/KG
RECALL
Weight Hold:
Press and hold the ON/ZERO button.
While holding the ON/ZERO button,
press and hold the RECALL button.
Display will show “ zero ” then “ h on ” or
“ h off ”. Release buttons when selection
is made. Default setting is “ h on ”.
Push to turn unit on. Display
shows the following:
^^^^ – self test
vssi – checks display segments
u 1.7 – software revision
b xx.x – battery voltage
(varies with AC plug
in and internal 9v
battery.) A reading of
6.0v indicates the need
for battery replacement;
the unit will shut off at
a reading of 5.5v.
0.0 – ready to weigh
Automatic Shut Off:
In AC mode, the indicator will shut
off in one hour. In battery mode, the
indicator will shut off in one minute.
Calibration:
To calibrate, install fresh 9 volt battery
in indicator and unplug indicator’s AC
adapter from back of indicator.
Push and hold until display
indicates unit shift.
Display will show “ conv ” until
the conversion is complete.
Press and hold the ON/ZERO button.
While holding the ON/ZERO button,
press and hold the LG/KG button.
After approximately 3 seconds, the
message on the display will change
from “zero” to “CAL0”.
Push the RECALL button –
The display will show the
message “ rECL” then alternately
flash between the last stable
weight and the “ rECL” message.
Press ON/ZERO button to return
to normal weighing.Works only
with hold function active.
Make sure the platform is empty and
press the ON/ZERO button. The indicator
will show a countdown from “16” to “1”.
Then it will show “C50”. Place a 50 lb.
weight on the platform and press the
ON/ZERO button. The indicator will
show a countdown from “16” to “1”. Then
will show “50”. Remove the 50 lb. weight
and press the ON/ZERO button. The scale
is now calibrated and has automatically
returned to normal weight mode.
Features:
Tare Function:
Any weight within the scale capacity can
be zeroed out by pressing the ON/ZERO
button. When the weight is removed, the
display flashes the tared weight. Press
ON/ZERO button to return to normal
weighing.
Re-plug indicator’s AC adapter into back
of indicator.
Switching from AC to DC:
Unplug the AC power cord from the
display. Then press the ON/ZERO
button to turn the indicator back on.
Weighing Function:
Display will blank out until a close range
of the weight is reached. With the hold
function active, the display will show the
stable weight and the “ hold ” indication.
The displayed weight will lock until the
weight is removed.
Switching from DC to AC:
Plug the AC adapter into a standard wall
socket and the cord into the AC outlet
on the back of the display. Then press
the ON/ZERO button to turn the
indicator back on.
6
Troubleshooting
Indicators:
In The Event Of A Problem:
Messages on the readout indicate
operating condition:
In the event that a problem occurs, a VSSI
factory technician is ready to assist you.
In order to save time, please check the
following items before calling:
OL
OPEN
Indicates weight on scale
exceeds capacity or
malfunction of scale display.
•
Does the readout display have a
message that indicates what the
problem is ? Refer to “Indicators”
at left for descriptions.
•
Check all cables/connections.
•
Unplug AC power and battery, then
plug-in again to reset the scale.
Indicates malfunctioning
of base or cable, or the
scale needs to be calibrated.
Indicates batteries are
discharged.
VSSI Tech Support: 1-800-299-9525
Care & Cleaning
Avoid use of chlorine bleach
for cleaning. Chlorides, bromides,
The VSSI Way ™ scale platform may be
cleaned with any commercially available
product recommended for use on
stainless steel. Frequent cleaning will
prolong the life and help maintain the
natural luster of the stainless steel.
iodides and thiocyanates will cause
pitting, corrosion and discoloration of the
metal. If using bleach, clean thoroughly
with water to completely remove bleach
residue.
To prevent scratching, use a soft cloth to
clean the scale. If scrubbing is necessary,
use a nylon or plastic type scrubber.
When cleaning, always rub in the direction of the “grain” of the metal.
Avoid excessive moisture.
The VSSI Way ™ platform scale contains
electronic components that may be
damaged by excessive exposure to
moisture. When cleaning or mopping
the floor, do not leave the scale in
standing water. For thorough cleaning, the
stainless steel platform cover may
be lifted off the scale base and cleaned
separately, away from electronic
components.
To remove minor scratches, we recommend using a 3M ScotchBrite ® scouring
pad rubbed lightly in the direction of
the “grain” of the metal.
Never use steel wool or steel
brushes when cleaning your platform
scale. Steel particles may become
embedded into the stainless steel and
cause rust.
7
Product Warranty
This product is warranted for 2 years from the date of delivery
to the original purchaser only. Warranty is only applicable if
customer complies with all instructions and specifications
furnished by VSSI, Inc. relating to installation, care, and application.
Customer agrees that they will not modify, misapply, or misuse
product in any manner which deviates from the VSSI, Inc.
instructions. Any repairs, alterations, or services provided by
parties other than VSSI, Inc. or its authorized representatives
may void warranty. The buyer is responsible for all
freight charges on returned items.
Product Satisfaction Policy
In the event that the customer is not fully satisfied with the products
purchased, VSSI, Inc. may, at its own discretion, arrange for the customer’s
account to be credited (excluding shipping charges) or replace the product.
The customer must notify VSSI of any claim of nonconformity or defect in
writing within 30 days from the date of receipt. The product must be
returned to VSSI in its original packaging, undamaged and showing no
unusual wear within 20 days of the customer’s written notice.
To return an item, follow these simple instructions:
•Call VSSI, Inc. for complete instructions (800-299-9525)
•A sales representative will give you a Return Authorization Number
•If a Restocking Fee applies, you will be informed at this time
•Label the boxes with this Return Authorization Number
(All items must have a Return Authorization Number)
•Return the items, postage/freight prepaid
If necessary, the VSSI sales representative will assist you with
freight arrangements.
Note: Custom orders and/or custom colors may not be returned.
, INC.
#1 Civil War Road - Area 5 • P.O. Box 431 • Carthage, MO 64836
1-800-299-9525 • fax 417-358-4716
email [email protected] • www.vssi.com
8
01/14 ©2014, VSSI, Inc.