Meter Box Details Head

CERTCLAD Vertical Shiplap Weatherboards Cavity System
Meter Box Details
Head
Internal lining
Additional building wrap
to overlap cavity closer
Framing
Minimum 15mm Drip edge
(Closure of cavity to bottom of cladding)
35mm 'Z' Flashing to
Mini
Building wrap turned
into trimmed opening
with flexible flashing
tape at corners
mum
5mm
capi
llary
Minimum 10mm cover
gap
Seal and rivet Meterbox Head Flashing
to both 35mm 'Z' Flashing and Meterbox
Air seal over backing rod
fitted all sides
around meterbox
Metal
meterbox
Meterbox Head Flashing
Note: Refer to the Vertical Shiplap Cavity System Installation Manual for full details