Van H. Gilbert Architect PC Construction Documents

PLAN SYMBOL LEGEND
1.
CONTRACTOR SHALL CAREFULLY EXAMINE ALL DRAWINGS AND SPECIFICATIONS TO PROPERLY DETERMINE SCOPE OF WORK.
SYMBOL
2.
DIVISION 22 SCOPE OF WORK INCLUDES THE INSTALLATION OF ALL SERVICE FITTINGS AND PIPING AS INDICATED ON FIXTURE &
EQUIPMENT SCHEDULES AND AS SHOWN ON LF- & LP- DRAWINGS (LABORATORY SERVICE FITTINGS FURNISHED BY DIVISION 11).
INSTALL ALL LABORATORY SERVICE FITTINGS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS AND INSTRUCTIONS.
FITTINGS ON LP-SERIES DRAWINGS ARE SYMBOLIC ONLY. REFER TO LF-SERIES DRAWINGS FOR ACTUAL FITTINGS, LOCATIONS
AND ARRANGEMENTS.
CONTRACTOR SHALL FIELD VERIFY CONDITIONS AT ALL POINTS OF CONNECTION PRIOR TO INSTALLATION.
4.
EQUIPMENT AND SYSTEM INSTALLATION SHALL CONFORM WITH ALL APPLICABLE LOCAL, STATE, FEDERAL AND HEALTH AUTHORITY
CODES.
5.
6.
ALL PIPING SHOWN ON DRAWINGS IS DIAGRAMMATIC. ADDITIONAL OFFSETS, WHICH MAY BE REQUIRED, IN WASTE & VENT RISERS
OR IN BELOW BENCH SERVICE PIPING SHALL BE PROVIDED UNDER DIVISION 22.
ALL EXPOSED TO VIEW PIPING SHALL BE INSTALLED WITH SPECIAL CARE GIVEN TO UNIFORM SPACING, LEVEL AND PLUMB, CLEAN
APPEARANCE FREE OF DEBRIS AND HANDLING MARKS, WITHOUT THE NEED FOR OFFSETS BELOW THE CEILING LEVEL.
8.
VALVES AND CAPS AT POINTS OF CONNECTION ARE SHOWN ON LP-SERIES DRAWINGS FOR COORDINATION ONLY, REFER TO
P-SERIES DRAWINGS FOR LOCATION AND SIZES.
9.
LABORATORY SINK (PROVIDED UNDER DIVISION 11)
CS*
CUP SINK (PROVIDED UNDER DIVISION 11)
FIXTURE/FITTING NO.
PIPE DROP ENCLOSURE (PROVIDED UNDER DIVISION 11). FOR
PIPING LAYOUT WITHIN PIPE DROP REFER TO DETAIL #5/LP-301.
ARCHITECTURE • INTERIORS • PLANNING
TW@DH
ICW
IHW
PW
1/2
1/2
1/2
1 1/2
1/2
1 1/2
SKB
1/2
1/2
1/2
SKC
1/2
1/2
1/2
LG
LA
LV
CA
P-TRAP & TRAP ARM
SAFETY SHOWER/RECESSED EYEWASH UNIT (PROVIDED UNDER
DIVISION 11)
FD
FLOOR DRAIN (SHOWN FOR COORDINATION PURPOSES ONLY.
REFER TO P-SERIES DRAWINGS.)
FS
FLOOR SINK (SHOWN FOR COORDINATION PURPOSES ONLY.
REFER TO P-SERIES DRAWINGS.)
SERVICE FITTING SCHEDULE
SF1
TW
ICW
IHW
PW
LG
LA
LV
CA
1/2
3/4
1/2
SF5
1/2
11. PROVIDE VALVED AND CAPPED CONNECTIONS WHERE "ROUGH-IN ONLY" OR "FUTURE SERVICES" ARE INDICATED ON DRAWINGS.
PIPE TEE & ELBOW UP
SF6
1/2
12. PIPE SIZES ARE INDICATED ON THESE DRAWINGS BY MEANS OF THE POINT OF CONNECTION, SERVICE DROP, FITTING, FIXTURE
AND EQUIPMENT CONNECTION SCHEDULES.
PIPE TEE & ELBOW DOWN
SF7
15. FLOOR DRAINS AND FLOOR SINKS ARE SHOWN ON LABORATORY PLUMBING PLANS FOR GENERAL LOCATION AND REFERENCE
ONLY. REFER TO PLUMBING DRAWINGS FOR ACTUAL LOCATION, SIZE AND TYPE OF DEVICE.
DETAIL NUMBER
DRAWING NUMBER
16. TEST ALL VALVES, SERVICE FITTINGS, EMERGENCY SHOWERS, EYEWASHES AND DRENCH HOSES AS SPECIFIED TO ENSURE
SYSTEM INTEGRITY AND PROPER OPERATION.
EQUIPMENT NO.
ICW
IHW
EQ1 ( AUTOCLAVE)
1
1/2
EQ2 (GLASSWARE WASHER)
1
1
PRV
LG
LA
LV
1
EW
PRESSURE REDUCING VALVE
TW
ICW
1
IHW
IHWR
PW
1/2
3/4
LG
LA
LV
1/2
1/2
3/4
21. REFERENCES TO LP DETAILS ARE SHOWN FOR SPECIFIC CONDITIONS ON THE LP FLOOR PLAN DRAWINGS. IN ADDITION, REFER
TO GENERAL NOTES AND PLAN SYMBOL LEGEND FOR MISCELLANEOUS DETAILS.
22. PROVIDE CLEANOUTS IN ACCORDANCE WITH PLUMBING CODE OR LOCAL, STATE, FEDERAL AND HEALTH AUTHORITY
REQUIREMENTS. COORDINATE CLEANOUT ACCESS LOCATIONS WITH LABORATORY CASEWORK INSTALLATION.
23. CONNECTIONS TO HOSE EYEWASHES AND/OR DRENCH HOSES TO BE PROTECTED BY BACK FLOW PREVENTERS INSTALLED
ACCORDING WITH PLUMBING CODE AND ACCEPTED BY THE LOCAL AUTHORITY HAVING JURISDICTION.
24. EMERGENCY SHOWERS, EYEWASHES AND DRENCH HOSES ARE FURNISHED UNDER DIVISION 11. INSTALL THESE DEVICES AS
DETAILED AND SHOWN ON PLANS. CONNECT TO TEPID WATER SUPPLY WITHOUT ISOLATION VALVES.
25. PROVIDE BACKFLOW PREVENTERS ON EQUIPMENT CONNECTIONS TO POTABLE WATER AS REQUIRED BY LOCAL CODE AND
ACCEPTED BY LOCAL AUTHORITY HAVING JURISDICTION.
3/4
1/2
A.F.C.
ABOVE FINISHED CEILING
BV
BALL VALVE
DN
DOWN
N.T.S.
NOT TO SCALE
P.O.C.
POINT OF CONNECTION
SIM.
SIMILAR
TYP.
TYPICAL
U.O.N.
UNLESS OTHERWISE NOTED
6
1/2
3/4
3/4
1/2
ROOM NAME
C
3/4
ROOM NO.
CHME MINATURE CHEMICAL
PILOT PLANT
C:\Users\rilao\Documents\LP-NMSU-JETT HALL-2015_romelrfd.rvt
9/14/2015 1:27:02 PM
FIXTURE, SERVICE FITTING AND EQUIPMENT LEGEND
INDUSTRIAL HOT WATER RETURN
DESIGNATES LABORATORY SINK(FURNISHED UNDER DIVISION 11 - U.O.N. REFER TO PLANS)
LA
LABORATORY AIR (15 psig)
DESIGNATES TYPES OF PLUMBING SERVICES REQUIRED AT SINK, REFER TO FIXTURE
CONNECTION SCHEDULE-LP-001
LG
LABORATORY GAS
LV
LABORATORY VACUUM
DESIGNATES CUP SINK(FURNISHED UNDER DIVISION 11 - U.O.N. REFER TO PLANS)
LW
LABORATORY WASTE
DESIGNATES TYPES OF PLUMBING SERVICES REQUIRED AT CUPSINK, REFER TO FIXTURE
CONNECTION SCHEDULE-LP-001
PW
PURIFIED WATER
SG1
SPECIAL GAS 1 (ARGON)
SKA
CSA
IHW
IHW
PW
LG
LA
LV
CA
GPM
GPM
GPM
GPM
GPM
sCFH
sCFM
sCFM
sCFM
DESIGN FLOW
3
3
3
184
1.01
PIPE SIZE (IN)
3/4
3/4
3/4
NEW CHME RESEARCH LAB
289
2.01
DESIGN FLOW
23
PIPE SIZE (IN)
1 1/4
NEW CHME RESEARCH LAB
289
2.02
DESIGN FLOW
10
5
PIPE SIZE (IN)
1
3/4
280 / 289
2.03
NEW CHME RESEARCH LAB
289
2.04
GLASSWARE/AUTOCLAVE
282
2.05
BSL-2 ROOM / NEW CHME
RESEARCH LAB
284 / 289
2.06
NEW CHME RESEARCH LAB
289
2.07
LASER ROOM / NEW CHME
RESEARCH LAB
286 / 289
2.08
NEW CHME RESEARCH LAB
289
2.09
NEW CHME RESEARCH LAB
289
2.10
Construction
Documents
1/2
4
24
4
6
*
3/4
1/2
1 1/4
2
4
1
1
*
1/2
1/2
3/4
DESIGN FLOW
23
2
1.5
PIPE SIZE (IN)
1 1/4
1/2
1/2
DESIGN FLOW
9
1.5
32
6
8
PIPE SIZE (IN)
1
1/2
3/4
1/2
1 1/4
DESIGN FLOW
10
8
8
1
PIPE SIZE (IN)
1
1
*
1/2
1/2
DESIGN FLOW
23
1.5
1.5
1
1
1
PIPE SIZE (IN)
1 1/4
1/2
1/2
*
1/2
3/4
DESIGN FLOW
9
3
2
32
6
8
PIPE SIZE (IN)
1
3/4
*
3/4
1/2
1 1/4
DESIGN FLOW
1
4
15
PIPE SIZE (IN)
1/2
1
1/2
DESIGN FLOW
6
3
PIPE SIZE (IN)
3/4
3/4
DESIGN FLOW
23
PIPE SIZE (IN)
1 1/4
1/2
1/2
4
12
2
3
*
1/2
1/2
1
B
NOTES:
1. FLOW RATES REPRESENT DESIGN PEAK LABORATORY LOADS USED FOR PIPE SIZING AT POC.
2. TW- TEPID WATER FOR SAFETY SHOWER/EYEWASH SIZED FOR INSTANTANEOUS/INCIDENTAL USE.
DESIGNATES SERVICE FITTING STATION
(FURNISHED UNDER DIVISION 11 - U.O.N. REFER TO PLANS)
3. * PROVIDE MINIMUM 3 fps CIRCULATION VELOCITY IN LABORATORY PW LOOP. SYSTEM STATIC PRESSURE SHOULD NOT EXCEED 60 psig.
VALVED SERVICE CONNECTION PER LP SCHEDULES AND DETAILS.
DESIGNATES TYPES OF PLUMBING SERVICES REQUIRED, REFER TO SERVICE FITTING
SCHEDULE-LP-001
TEPID WATER
TW
ICW
SECOND FLOOR
INDUSTRIAL HOT WATER
LABORATORY WASTE VENT
TW
POC NO.
FIRST FLOOR
DESCRIPTION
LWV
1/2
PIPING POINT OF CONNECTION SCHEDULE
PIPING LEGEND
IHWR
1/2
* BUILDING PW WATER SIZE
NOTES:
1. BUILDING PW WATER LOOP TO EACH SERVICE DROP PER LP-SERIES DRAWINGS.
B
IHW
N
GI 9/11/15
Jett Hall and Jett Annex
Renovations and
Additions
*
1/2
ANALYTICAL/INSTRUMENTATION /
NEW CHME RESEARCH LAB
ICW
N AL E N
New Mexico State
University
SG1
5
26. SEAL ALL PIPING PENETRATIONS THROUGH RATED WALLS WITH UL APPROVED SYSTEM. SEE ARCHITECTURAL & PLUMBING
DETAILS.
INDUSTRIAL COLD WATER
CA
3/4
7
ABOVE FINISHED FLOOR
S IO
1/2
3
DRENCH HOSE (EYEWASH)- TEPID WATER
(FITTING FURNISHED UNDER DIVISION 11 & INSTALLED UNDER
DIVISION 22)
A.F.F.
ES
SERVICE DROP SCHEDULE
PIPE SIZE IN INCHES
C
20. ALL PLUMBING VENTS SHALL EXTEND SIX INCHES ABOVE FLOOD LEVEL RIM OF FIXTURE SERVED BEFORE CHANGING FROM
VERTICAL TO A HORIZONTAL POSITION UNLESS OTHERWISE NOTED FOR SPECIAL VENTING ARRANGEMENTS.
W
18351
4
19. PROVIDE MINIMUM SIZE OF 2" LABORATORY WASTE & 1-1/2" VENT RISER WHERE
LABORATORY WASTE POINTS OF
CONNECTION SYMBOL IS INDICATED ON DRAWINGS. WASTE PENETRATIONS AT LABORATORY SINKS & CUPSINKS MAY REQUIRE
OFFSET TO AVOID STRUCTURAL BEAMS AND JOISTS. REFER TO DETAIL #3/LP-301.
R. LEMES
L
U
M EXI
PROJECT
DETAIL REFERENCE BUBBLE
COORDINATES PLAN WITH DETAIL SHEETS
CYLINDER MANIFOLD
W
SG
1/2
2
18. PROVIDE STAINLESS STEEL ESCUTCHEON PLATES FOR ALL EXPOSED PIPE PENETRATIONS IN WALLS AND CEILINGS.
COMPRESSED AIR (100 pisg)
CA
NOTES:
1. BUILDING PW WATER LOOP TO EACH EQUIPMENT PER LP-SERIES DRAWINGS.
2. CONNECTION TO SERVICE PER LP-SERIES DRAWINGS.
DROP NUMBER NO.
17. INSULATE PIPING IN ACCORDANCE WITH DIVISION 22 SPECIFICATIONS. INSULATION TO INCORPORATE ENTIRE LENGTH OF PIPE
FROM POINT OF CONNECTION TO POINT OF USE.
PW
CO
SERVICE DROP NUMBER - COORDINATES PLAN WITH SERVICE
DROP SCHEDULE
1
D
PIPE SIZE IN INCHES
F
14. FITTING/FIXTURE INLET SIZE MAY VARY. PROVIDE APPROPRIATE CONNECTORS.
EQUIPMENT CONNECTION SCHEDULE
** 50-80 PSIG (VERIFY WITH MANUFACTURER)
POINT OF CONNECTION NUMBER - COORDINATES PLAN WITH
POINT OF CONNECTION SCHEDULE
1
1/2
P RO
13. REFER TO THE LABORATORY PLUMBING DETAILS FOR TYPICAL PIPE ROUTING BELOW AND WITHIN THE CASEWORK. THE QUANTITY,
SIZE AND MATERIAL OF PIPE WILL VARY IN ACCORDANCE WITH THE TYPE OF SERVICES. INSTALL IN ACCORDANCE WITH THE PIPING
ARRANGEMENT AND ORIENTATION SHOWN ON PLANS.
1/2
E
TR
POINT OF CONNECTION TO VALVED AND CAPPED SERVICES
(VALVES AND CAP PROVIDED UNDER DIVISION 22 P-SERIES
DRAWINGS)
1/2
MECHANICAL/ELECTRICAL ENGINEER
Bridgers & Paxton Consulting Engineers
4600-C Montgomery Blvd. NE
Albuquerque, NM 87109
Phone 505-883-4111
PA
POINT OF CONNECTION TO 1-1/2" LABORATORY WASTE VENT RISE
@ 6"A.F.C. (U.O.N.)
(REFER TO P-SERIES DRAWINGS FOR CONTINUATION)
STRUCTURAL ENGINEER
Stubbs Engineering, Inc.
277 E. Amador Ave. Suite 200
Las Cruces, NM 88001
Phone 575-993-5228
3/4
SF4
POINT OF CONNECTION TO 2" LABORATORY WASTE @ 6"A.F.F. &
1-1/2" LABORATORY WASTE VENT RISE @ 6"A.F.C. - U.O.N.
(REFER TO P-SERIES DRAWINGS FOR CONTINUATION)
SG1
1/2
SF3
PIPE ELBOW UP (OR) TEE UP & DOWN
B. WHERE SERVICE DROPS ARE INDICATED, THE SERVICE DROP SCHEDULE SHALL GOVERN THE DROP AS WELL AS EACH
ASSOCIATED BRANCH. THESE SERVICES SHALL EXTEND TO BELOW BENCH AND RUN HORIZONTALLY UNDIMINISHED IN SIZE UP
TO THE LAST TEE SERVICING DIFFERENT FITTINGS.
C. THE FIXTURE, SERVICE FITTING & EQUIPMENT CONNECTION SCHEDULE SHALL INDICATE THE SIZE FOR THE FINAL SECTION
OF PIPING.
CIVIL ENGINEER
Lilley Engineering, Inc.
5160 Calle Bellisima
Las Cruces, NM 88011
Phone 575-521-0006
1 1/4
SF2
PIPE CAPPED
V
LABORATORY CONSULTANT
RFD - Research Facilities Design
3965 Fifth Ave. Suite 400
San Diego, CA 92103
Phone 619-297-0159
NOTES:
1. BUILDING PW WATER LOOP TO EACH FIXTURE PER LP-SERIES DRAWINGS.
2. CONNECTION TO SERVICE PER LP-SERIES DRAWINGS.
3. ALL SERVICES TO FUME HOOD TO BE PRE-PIPED TO SINGLE POINT OF CONNECTION BY DIV. 11.
FUME HOOD SERVICE FITTING LOCATION MAY VARY, REFER TO LF PLANS.
SERVICE FITTING NO.
PIPING BELOW FLOOR
A. THE POINT OF CONNECTION SCHEDULE INDICATES PIPE SIZE ENTERING EACH LABORATORY. THE SIZE SHALL EXTEND
UNDIMINISHED UP TO THE LAST TEE BRANCH OF THE CEILING DISTRIBUTION PIPING.
CONSULTANTS
PIPE SIZE IN INCHES
PIPING BELOW BENCH
W
2428 Baylor Dr SE Albuquerque, NM 87106
Tel 505-247-9955 Fax 505-247-1826
E-mail [email protected]
Web Site www.vhgarchitect.com
E
1 1/2
PIPE ELBOW DOWN
CA
LW(P-TRAP)
1 1/2
10. INSTALL WATER HAMMER ARRESTORS ON LINES SERVING FIXTURES OR EQUIPMENT WITH QUICK CLOSING VALVES.
PIPING/ABBREVIATION
SG
CSA
THE FOLLOWING GUIDELINES SHALL GOVERN THE PIPE SIZES:
D
SK*
PROVIDE REDUCERS ON POINT OF CONNECTION WHERE SIZES SHOWN ON P-SERIES DRAWINGS ARE LARGER THAN INDICATED
ON LP-SERIES DRAWINGS. PROVIDE ADAPTERS/REDUCERS WHERE NECESSARY FOR CONNECTION TO PIPING SERVICES OR
WASTE LINES.
Van H. Gilbert Architect PC
PIPE SIZE IN INCHES
SKA
PIPE LINES ENTERING LABORATORIES ARE SHOWN WITH WIDE SEPARATION FOR CLEAR IDENTIFICATION PURPOSES ONLY.
MAINTAIN A TIGHT AND ORDERLY GROUPING OF PIPES WITHIN EACH LABORATORY. LOCATION, ROUTING AND SUPPORT OF
LABORATORY PIPING SHALL BE COORDINATED WITH THE INSTALLED EQUIPMENT, OVERHEAD SERVICE CARRIERS, PIPE DROP
ENCLOSURES, BUILDING STRUCTURAL ELEMENTS, DUCTWORK, ELECTRICAL CONDUITS, POWER PANELS AND LIGHT FIXTURES.
7.
6
FIXTURE CONNECTION SCHEDULE
ABBREVIATION DESCRIPTION
SS
3.
5
R
GENERAL NOTES
4
EE
3
EW
E
2
NE
1
EQ1
GAL
PW WATER HOURLY CONSUMPTION
30
PW WATER 4-HOUR CONSUMPTION
120
A
14400
RI
Checked By
BS/PL
Copyright ©
GPM
PW WATER PEAK FLOW RATE
September 11, 2015
Drawn By
ESTIMATED PW WATER CONSUMPTION AND PEAK LOAD
DESIGNATES TYPES OF PLUMBING SERVICES REQUIRED, REFER TO EQUIPMENT
CONNECTION SCHEDULE-LP-001
Description
Project Number
6. IHW HARDNESS SHOULD NOT TO EXCEED 120 MG/L (PPM) TO LABORATORY EQUIPMENT.
DESIGNATES EQUIPMENT STATION
(FURNISHED UNDER DIVISION 11 AND/OR OFOI. REFER TO PLANS)
Date
Date
5. IHWR CIRCULATED INSIDE LABORATORY AS SHOWN ON PLANS. DESIGN FLOW PER P-SERIES DRAWINGS.
SF1
A
Mark
4. COMPRESSED AIR DISTRIBUTED AT 100 psig TO LABORATORY POC. PROVIDE PRESSURE REGULATORS AS SHOWN ON PLANS FOR LOWER
PRESSURE SERVICES.
VAN H. GILBERT ARCHITECT PC
SHEET TITLE
LAB PLUMBING GEN.
NOTES, LEGENDS &
SCHEDULES
6
LP-001
1
2
3
4
5
6
SHEET
1
99
OF
187
6
1
2
3
4
5
6
Van H. Gilbert Architect PC
ARCHITECTURE • INTERIORS • PLANNING
DN
DN
E
2428 Baylor Dr SE Albuquerque, NM 87106
Tel 505-247-9955 Fax 505-247-1826
E-mail [email protected]
Web Site www.vhgarchitect.com
E
CONSULTANTS
LABORATORY CONSULTANT
RFD - Research Facilities Design
3965 Fifth Ave. Suite 400
San Diego, CA 92103
Phone 619-297-0159
A
E
MAIL
ME/AE OFFICE
104B
SEMINAR
ME/AE OFFICE
ME/AE OFFICE
ME/AE OFFICE
ME/AE OFFICE
116
114
112
110
108
104A
LOBBY
H100
CHME OFFICE
CHME OFFICE
CHME OFFICE
CHME OFFICE
CHME OFFICE
CHME OFFICE
CHME OFFICE
CHME OFFICE
CHME OFFICE
150
152
154
156
158
160
162
164
166
CIVIL ENGINEER
Lilley Engineering, Inc.
5160 Calle Bellisima
Las Cruces, NM 88011
Phone 575-521-0006
CHME OFFICE
168
ME/AE OFFICE
106
ME/AE
DIRECTORS
OFFICE SUITE
104
STRUCTURAL ENGINEER
Stubbs Engineering, Inc.
277 E. Amador Ave. Suite 200
Las Cruces, NM 88001
Phone 575-993-5228
B
CHME OFFICE
163
UNISEX
R101
SUPPORT
CHME OFFICE
SUITE
117D
159
C
MECHANICAL/ELECTRICAL ENGINEER
Bridgers & Paxton Consulting Engineers
4600-C Montgomery Blvd. NE
Albuquerque, NM 87109
Phone 505-883-4111
CHME OFFICE
159G
BREAK ROOM
105A
VESTIBULE
H117
STOR
S117B
ME /AE
GRADUATE
STUDENT
OFFICE
ME/AE
SEMINAR
115
113
DATA ROOM
T165
ME/AE
SEMINAR
CLASSROOM
111
109
MEN
WOMEN
OFFICE
105
R153
R151
CHASE
CHME OFFICE
103B
STOR
D
CHME OFFICE
159B
CHME OFFICE
S117A
159C
DN
CHME OFFICE
159D
159E
DN
159F
D
D
17
22
10
16
14
11
26
ELECTRICAL
ROOM
4
7
E167
6
1
R. LEMES
L
U
M EXI
CO
W
E
TR
DN
13
8
PA
20
23
CHME OFFICE
NE
OFFICE
117C
CHME OFFICE
159A
F
ES
EE
P RO
R
18351
DN
MECHANICAL
ROOM
CHME
COMPUTER
LAB
M198
177
S IO
N AL E N
N
GI 9/11/15
PROJECT
CHME
STUDENT
PROJECT/STUDY
AREA
CORRIDOR
New Mexico State
University
178
H103
STORAGE
S180
Jett Hall and Jett Annex
Renovations and
Additions
ME/AE
WELDING
182
KITCHEN
179
STUDENT
PROJECTS
CENTER
C
C
196
CHME
MINATURE
CHEMICAL
PILOT PLANT
LP-111
ME/ AE
STORAGE
184
ME/ AE
OFFICE
S196B
ME/AE LAB
ME/AE LAB
191A
191
Construction
Documents
196A
ME/AE
ROBOTICS
LAB
191C
ME/AE LAB
191B
B
B
ME/ AE
HYDRAULICS
LAB
C:\Users\rilao\Documents\LP-NMSU-JETT HALL-2015_romelrfd.rvt
194
CHME
UNDERGRADUATE
LAB
193
KEY PLAN
ME/ AE
OFFICE
194A
LAB
193A
Mark
Description
Date
DN
DN
September 11, 2015
Project Number
14400
Drawn By
A
A
RI
Checked By
BS/PL
Copyright ©
FLOOR PLAN
1 FIRST
Scale: 3/32" = 1'-0"
0'
2'
4'
VAN H. GILBERT ARCHITECT PC
SHEET TITLE
Project
North
9/14/2015 1:27:05 PM
Date
LAB PLUMBING FIRST
FLOOR KEYPLAN
8'
LP-101
1
2
3
4
5
6
SHEET
100
OF
187
6
1
2
3
4
5
6
Van H. Gilbert Architect PC
ARCHITECTURE • INTERIORS • PLANNING
23
22
20
17
16
14
13
11
10
26
8
7
6
4
1
E
2428 Baylor Dr SE Albuquerque, NM 87106
Tel 505-247-9955 Fax 505-247-1826
E-mail [email protected]
Web Site www.vhgarchitect.com
E
CONSULTANTS
LABORATORY CONSULTANT
RFD - Research Facilities Design
3965 Fifth Ave. Suite 400
San Diego, CA 92103
Phone 619-297-0159
A
CLASSROOM
216
CHME OFFICE
CHME OFFICE
CHME OFFICE
CHME OFFICE
CHME OFFICE
CHME OFFICE
204
250
252
254
256
258
260
E
CHME OFFICE
MEETING/WAITING
ROOM
CHME OFFICE
262
264
268
CIVIL ENGINEER
Lilley Engineering, Inc.
5160 Calle Bellisima
Las Cruces, NM 88011
Phone 575-521-0006
CLASSROOM
CLASSROOM
208
CLASSROOM
ME/ AE
DIRECTORS
OFFICE
206
210
B
STRUCTURAL ENGINEER
Stubbs Engineering, Inc.
277 E. Amador Ave. Suite 200
Las Cruces, NM 88001
Phone 575-993-5228
CORRIDOR
H201
STOR
S257
C
CHME OFFICE
263
ME/ AE
OFFICE
JAN
JAN
201A
J255
CHME OFFICE
CHME
CONFERENCE
ROOM
265
274
217A
DATA
VESTIBULE
CLASSROOM
H217
CLASSROOM
MEN
T203
207
CLASSROOM
215
CLASSROOM
213
MECHANICAL/ELECTRICAL ENGINEER
Bridgers & Paxton Consulting Engineers
4600-C Montgomery Blvd. NE
Albuquerque, NM 87109
Phone 505-883-4111
259
R253
WOMEN
R201
STOR
S217B
D
D
D
DN
ELECTRICAL
ROOM
ELECTRICAL
ROOM
E301
E267
PA
CO
W
E
TR
R. LEMES
L
U
M EXI
NE
PENTHOUSE
M301
F
ES
EE
P RO
BIOMASS
THERMOCHEMICAL
PROCESSING
LAB
R
18351
S IO
N AL E N
N
GI 9/11/15
278
PROJECT
New Mexico State
University
LP-112A
C
Jett Hall and Jett Annex
Renovations and
Additions
C
ANALYTICAL /
INSTRUMENTATION
CHME RESEARCH
LAB BUILD-OUT
ALTERNATE #1
(REFER TO DIVISION 1
SPECIFICATIONS)
280
GLASSWARE /
AUTOCLAVE
282
Construction
Documents
BSL-2 ROOM
284
CHME RESEARCH
LAB BUILD-OUT
ALTERNATE #2
(REFER TO DIVISION 1
SPECIFICATIONS)
LASER ROOM
286
CHME
RESEARCH
LAB
289
B
MICROSCOPE
ROOM
LP-112B
B
V
288
EQUIP. ROOM
9/14/2015 1:27:56 PM
C:\Users\rilao\Documents\LP-NMSU-JETT HALL-2015_romelrfd.rvt
290
THIN FILMS
LAB
KEY PLAN
292
LAB
MANAGER
OFFICE
295
Mark
Date
Description
Date
September 11, 2015
Project Number
Drawn By
Project
North
A
14400
A
RI
Checked By
BS/PL
Copyright ©
FLOOR PLAN
1 SECOND
Scale: 3/32" = 1'-0"
0'
2'
4'
VAN H. GILBERT ARCHITECT PC
SHEET TITLE
8'
LAB PLUMBING
SECOND FLOOR
KEYPLAN
LP-102
1
2
3
4
5
6
SHEET
2
101
OF
187
6
1
2
3
4
5
6
Van H. Gilbert Architect PC
ARCHITECTURE • INTERIORS • PLANNING
E
2428 Baylor Dr SE Albuquerque, NM 87106
Tel 505-247-9955 Fax 505-247-1826
E-mail [email protected]
Web Site www.vhgarchitect.com
E
CONSULTANTS
LABORATORY CONSULTANT
RFD - Research Facilities Design
3965 Fifth Ave. Suite 400
San Diego, CA 92103
Phone 619-297-0159
CIVIL ENGINEER
Lilley Engineering, Inc.
5160 Calle Bellisima
Las Cruces, NM 88011
Phone 575-521-0006
STRUCTURAL ENGINEER
Stubbs Engineering, Inc.
277 E. Amador Ave. Suite 200
Las Cruces, NM 88001
Phone 575-993-5228
MECHANICAL/ELECTRICAL ENGINEER
Bridgers & Paxton Consulting Engineers
4600-C Montgomery Blvd. NE
Albuquerque, NM 87109
Phone 505-883-4111
W
CO
1
(TYP.)
LP-301
R. LEMES
L
U
M EXI
E
TR
PA
D
NE
D
R
F
ES
EE
P RO
1.01
CA
18351
TW
ICW
IHW
PRV
S IO
N AL E N
N
GI 9/11/15
PROJECT
W
SKC
LG
CHME MINATURE
CHEMICAL PILOT
PLANT
LA
IHW
LG
ICW
LA
New Mexico State
University
TW
LG
7
LA
1
LP-303
Jett Hall and Jett Annex
Renovations and
Additions
184
SF7@+54"
C
LG
LA
C
5
LP-302 (TYP.)
LG
LA
LA
LG
SF7@+54"
Construction
Documents
Project
North
FLOOR PLAN - PILOT PLANT
1 FIRST
Scale: 1/4" = 1'-0"
0'
2'
4'
8'
C:\Users\rilao\Documents\LP-NMSU-JETT HALL-2015_romelrfd.rvt
B
B
KEY PLAN
Mark
Date
Description
Date
September 11, 2015
Project Number
14400
Drawn By
A
A
RI
Checked By
BS/PL
Copyright ©
VAN H. GILBERT ARCHITECT PC
9/14/2015 1:27:57 PM
SHEET TITLE
LAB PLUMBING FIRST
FLOOR
LP-111
1
2
3
4
5
6
SHEET
102
OF
187
6
1
2
3
4
5
6
Van H. Gilbert Architect PC
ARCHITECTURE • INTERIORS • PLANNING
E
2428 Baylor Dr SE Albuquerque, NM 87106
Tel 505-247-9955 Fax 505-247-1826
E-mail [email protected]
Web Site www.vhgarchitect.com
E
CONSULTANTS
1 1/2" TW
1 1/4" IHW
1/2" IHWR
2" ICW
1" PW
1 1/4" LG
2" LV
3/4 CA
LG SOLENOID
VALVE
LG SOLENOID VALVE
SWITCH
LABORATORY CONSULTANT
RFD - Research Facilities Design
3965 Fifth Ave. Suite 400
San Diego, CA 92103
Phone 619-297-0159
TW
D
IHW
TW
ICW
LA
LV
IHW
PW
LG
CA
ICW
IHW
IHWR SHUT- OFF
& BALANCE
VALVE
PW
W
LG
PA
PW
W
ES
PW
F
CA
CSA
R
LV
18351
P RO
CSA
CO
1
W
1
R. LEMES
L
U
M EXI
E
TR
W
W
PW
2
LP-302 (TYP.)
D
ICW
1
ICW
W
IHWR
CSA
W
SKA
IHW
IHW
PW
TW
PW
LA
PW
LV
D
MECHANICAL/ELECTRICAL ENGINEER
Bridgers & Paxton Consulting Engineers
4600-C Montgomery Blvd. NE
Albuquerque, NM 87109
Phone 505-883-4111
278
PW
CSA
LG
E267
LG
CA
LV
BIOMASS
THERMOCHEMICAL
PROCESSING LAB
7
LP-301
(TYP.)
EE
LA
PW
ICW
IHW
LG
LA
LV
PW
PRV
1
LG
LV
ELECTRICAL
ROOM
LG
PW
ICW
ICW
IHW
SF1
2.01
PW
2.02
STRUCTURAL ENGINEER
Stubbs Engineering, Inc.
277 E. Amador Ave. Suite 200
Las Cruces, NM 88001
Phone 575-993-5228
NE
PW
W
PW
PW
W
IHWR
SKA
SKA
PW
W
CIVIL ENGINEER
Lilley Engineering, Inc.
5160 Calle Bellisima
Las Cruces, NM 88011
Phone 575-521-0006
S IO
N AL E N
N
GI 9/11/15
1
ICW
1
LG
IHW
LV
LA
PW
ICW
W
PW
LV
LA
LG
IHW
PROJECT
ICW
CSA
IHW
CSA
New Mexico State
University
LV
LG
LA
IHW
ICW
ICW
IHW
PW
SKA
1
W
CSA
Jett Hall and Jett Annex
Renovations and
Additions
CSA
C
W
289
CSA
IHW
TW
W
IHWR
CSA
CSA
2.04
LA
LG
LV
LG
LV
IHW
CSA
PW
3
LP-302
1
1
W
PW
9/14/2015 1:28:13 PM
B
IHWR
IHW
ICW
LV
CSA
CA
1
LG
ICW
CSA
LA
LV
LV
LA
ICW
TW
1
LG
GLASSWARE /
AUTOCLAVE
IHW
282
ICW
IHW
PW
PW
CA
CA
PW
ICW
IHWR
CSA
7
LP-302
W
2.05
IHW
ICW
PW
W
W
MATCHLINE
CA
LV
1
Mark
EQ2
LG
MATCHLINE
LP-112B
PW
8
LP-302
PW
CSA
KEY PLAN
EQ1
PW
PW
IHW
ICW
ICW
LG
W
CA
1
W
SKA
LV
LA
C:\Users\rilao\Documents\LP-NMSU-JETT HALL-2015_romelrfd.rvt
CSA
PW
6
LP-301 (TYP.)
LG
W
SKA
PW
B
W
PW
1
W
SF2
@+84"
ICW
W
PW
IHWR
CSA
LV
PW
IHW
LG
280
W
TW
ICW
ANALYTICAL /
INSTRUMENTATION
PW
PW
IHW
ICW
PW
SKA
LA
1
Construction
Documents
CA
LG
PRV
ICW
ICW
LA
ICW
TYP.
PW
1
ICW
2
LP-301
PW
1
LV
1
LP-301 TYP.
PW
CSA
LV
PRV
ICW
W
LA
IHWR
1
W
W
1
ICW
1
IHWR SHUT- OFF &
BALANCE VALVE
ICW
IHW
IHWR
PW
PW
LG
TW
IHW
W
SF1
ICW
2.03
IHW
CHME RESEARCH
LAB
PW
W
1
C
CSA
IHWR
W
Description
Date
September 11, 2015
Project Number
LP-112B
14400
Drawn By
A
A
Project
North
FLOOR PLAN - EAST WING - NORTH
1 SECOND
Scale: 1/4" = 1'-0"
Date
RI
Checked By
BS/PL
Copyright ©
VAN H. GILBERT ARCHITECT PC
SHEET TITLE
0'
2'
4'
LAB PLUMBING
SECOND FLOOR NORTH
8'
LP-112A
1
2
3
4
5
6
SHEET
3
103
OF
187
6
1
2
3
4
5
6
Van H. Gilbert Architect PC
ARCHITECTURE • INTERIORS • PLANNING
LP-112A
ICW
CSA
SF1
TW
2.06
ICW
PW
1
2
LP-301 LP-301
LA
LV
2.07
CA
4
SF4@+54"
LV
LA
LA
LG
LG
1
CA
ICW
LV
(TYP.)
CSA
LA
SF4
SF4
LG
ICW
LA
LV
LV
LA
CA
LG
W
ICW
18351
P RO
1
W
R. LEMES
L
U
M EXI
CO
ICW
LV
LA
LA
E
TR
LV
LG
W
SF5
@+54"
PA
LG
1
D
4
W
CA
1
6
LP-302
ES
F
W
R
LV
CSA
SKA
IHWR
SHUT- OFF
& BALANCE
VALVE
2.08
LA
CSA
CSA
D
CA
289
W
W
TW
1
286
IHW
CHME RESEARCH
LAB
(TYP.)
MECHANICAL/ELECTRICAL ENGINEER
Bridgers & Paxton Consulting Engineers
4600-C Montgomery Blvd. NE
Albuquerque, NM 87109
Phone 505-883-4111
LASER ROOM
IHWR
1
W
1
W
SF5
@+54"
PW
ICW
LV
3
LP-302
SF4
SF4
IHW
PW
LA
CSA
STRUCTURAL ENGINEER
Stubbs Engineering, Inc.
277 E. Amador Ave. Suite 200
Las Cruces, NM 88001
Phone 575-993-5228
LV
LV
CSA
W
CIVIL ENGINEER
Lilley Engineering, Inc.
5160 Calle Bellisima
Las Cruces, NM 88011
Phone 575-521-0006
SF3
@+98"
SKA
PRV
ICW
(TYP.)
EE
LG
LV
LA
NE
LV
ICW
LA
LV
PW
LG
LV
LA
LA
LA
LABORATORY CONSULTANT
RFD - Research Facilities Design
3965 Fifth Ave. Suite 400
San Diego, CA 92103
Phone 619-297-0159
IHW
PW
ICW
LG
1
PW
PW
PW
2
LP-302
(TYP.)
ICW
PW
1
4
LP-302
LV
W
W
CONSULTANTS
BSL-2 ROOM
284
(TYP.)
CA
3
PW
PRV
LV
CSA
CSA
1
LG
W
E
W
IHW
PW
PW
CSA
2428 Baylor Dr SE Albuquerque, NM 87106
Tel 505-247-9955 Fax 505-247-1826
E-mail [email protected]
Web Site www.vhgarchitect.com
MATCHLINE
SKB
W
W
W
PW
E
1
PW
1
IHWR
MATCHLINE
IHW
TW
LP-112A
S IO
N AL E N
N
GI 9/11/15
CSA
ICW
ICW
LV
LA
1
W
W
CSA
CSA
PW
W
Jett Hall and Jett Annex
Renovations and
Additions
PW
ICW
LG
LA
1
LG
ICW
LV
LG
288
IHWR
LA
New Mexico State
University
IHW
1
LV
MICROSCOPE
ROOM
TW
CSA
PROJECT
C
LG
EQUIP. ROOM
290
LV
CSA
C
6
(TYP.)
LP-301
CSA
W
1
CA
1
PW
LV
PW
ICW
SKA
W
LG
IHW
LA
2
SF6
SF6
IHW
IHWR
PW
PW
PW
SG1 DEWAR
MANIFOLD
PW
LV
LV
W
SKA
W
LA
PW
1/2"ø
SG1
9
LP-302
ICW
PW
LG
SF2
@+84"
IHWR
IHW
LG
CA
LA
PRV
SKA
ICW
Construction
Documents
IHWR SHUT- OFF &
BALANCE VALVE
2.09
PW
ICW
SF6
PW
SF6
LG SOLENOID
VALVE
SWITCH
(TYP.)
7
LP-301
W
THIN FILMS LAB
292
2.10
TW
SF1
5
9/14/2015 1:28:28 PM
C:\Users\rilao\Documents\LP-NMSU-JETT HALL-2015_romelrfd.rvt
B
B
LAB MANAGER
OFFICE
295
KEY PLAN
Mark
Date
Description
Date
September 11, 2015
Project Number
14400
Drawn By
A
A
Project
North
FLOOR PLAN - EAST WING - SOUTH
1 SECOND
Scale: 1/4" = 1'-0"
RI
Checked By
BS/PL
Copyright ©
VAN H. GILBERT ARCHITECT PC
SHEET TITLE
0'
2'
4'
LAB PLUMBING
SECOND FLOOR SOUTH
8'
LP-112B
1
2
3
4
5
6
SHEET
4
104
OF
187
6
1
2
3
4
5
6
Van H. Gilbert Architect PC
ARCHITECTURE • INTERIORS • PLANNING
1
WALL
SHUT-OFF VALVES
BY DIVISION 22
P-SERIES DRAWINGS
2
LABORATORY PLUMBING
PIPE SERVICE, SIZES PER
POINT OF CONNECTION
SCHEDULE, REFER TO LP-002
PIPE SERVICES PER
P-SERIES DWGS.
WATER BY-PASS SHUT-OFF VALVE
(NORMALLY CLOSED)
MAX. DISTANCE BETWEEN
FITTINGS SHALL BE THREE
PIPE DIAMETERS
3
SHUT-OFF VALVES
TW
ICW
IHW
IHWR
POINT OF CONNECTION TO 1-1/2"
LABORATORY WASTE VENT AT 6"
ABOVE FINISHED CEILING REFER TO
P-SERIES DRAWINGS
NOTE:
WASTE PENETRATION OFFSETS
MAY OCCUR AT HOODS, WALL,
ISLAND, AND PENINSULA BENCH
LABORATORY SINKS AND/OR
CUPSINKS. LOCATIONS VARY TO
AVOID STRUCTURAL BEAMS AND
JOISTS. REFER TO PLANS.
1
POINT OF CONNECTION TO 2"
LABORATORY WASTE AT 6" ABOVE
FINISHED FLOOR, REFER TO P-SERIES
DRAWINGS
2428 Baylor Dr SE Albuquerque, NM 87106
Tel 505-247-9955 Fax 505-247-1826
E-mail [email protected]
Web Site www.vhgarchitect.com
E
CONSULTANTS
LABORATORY WASTE OFFSET,
MAINTAINED WITHIN TOE KICK SPACE
OF BASE CABINET REFER TO P-SERIES
DRAWINGS FOR CONTINUATION
LABORATORY CONSULTANT
RFD - Research Facilities Design
3965 Fifth Ave. Suite 400
San Diego, CA 92103
Phone 619-297-0159
WALL
PW
BOTTOM
OF PIPE
6"-12"
PW
PW
LG
CA
LV
PCWS
PCWR
LA
-
CEILING
CIVIL ENGINEER
Lilley Engineering, Inc.
5160 Calle Bellisima
Las Cruces, NM 88011
Phone 575-521-0006
WATER SHUT-OFF VALVE
(NORMALLY OPEN) - TYP
PRESSURE
REGULATING
VALVE
UNISTRUT PIPE
SUPPORT, REFER TO
DETAIL #8/LP-301
CORRIDOR
LAB
ELEVATION
STRUCTURAL ENGINEER
Stubbs Engineering, Inc.
277 E. Amador Ave. Suite 200
Las Cruces, NM 88001
Phone 575-993-5228
3
NOTES:
1. PROVIDE REDUCERS WHERE PIPE
SIZES ON THE LABORATORY
PLUMBING SIDE IS SMALLER THAN
THE POINT OF CONNECTION SIZE
NOTED ON THE P-SERIES DRAWINGS.
PLAN VIEW
2. LOCATE VALVES IN READILY
ACCESSIBLE CEILING SPACE.
3. SERVICES MAY VARY, REFER TO
PLANS & POC SCHEDULE.
2
LW
LAB
MECHANICAL/ELECTRICAL ENGINEER
Bridgers & Paxton Consulting Engineers
4600-C Montgomery Blvd. NE
Albuquerque, NM 87109
Phone 505-883-4111
3
REFER TO PLUMBING DRAWING
(P-SERIES) FOR PIPING UPSTREAM
OF THIS POINT
FINISHED FLOOR
PLAN
PW
CORRIDOR
A
PW
PW
E
ALIGN
VALVES
LOCATE AS CLOSE
AS PRACTICAL TO
LAB WALL
LWV
ALIGN
VALVES
REFER TO LAB PLUMBING DRAWINGS
(LP-SERIES) FOR PIPING
DOWNSTREAM OF THIS POINT
D
D
SECTION A
1 PW WATER SUPPLY VALVES AT POC
2 WASTE OFFSET AT SINK LOCATION
1" = 1'-0"
3
R. LEMES
L
U
M EXI
W
CO
PA
3" = 1'-0"
NE
1/2" = 1'-0"
E
TR
TYPICAL POINT OF CONNECTION PIPING AT LAB ENTRY DOORS
2
SERVICE FITTINGS AS SHOWN
ON LF-SERIES DRAWINGS. REFER TO
SCHEDULE DRAWING LP-001
3
1-1/2 "P" TRAP
4
POINT OF CONNECTION TO 1-1/2"
LABORATORY WASTE VENT AT
6" ABOVE FINISHED CEILING
REFER TO P-SERIES DRAWINGS
5
LABORATORY WASTE POINT OF
CONNECTION TO SINK TAILPIECE
6
1/2" DIAMETER FLEXIBLE CONNECTORS
7
FIXTURE SUPPLY STOP VALVE WITH
KEY & ESCUTCHEON PLATE AT
CABINET BACK RAIL. MOUNT AT
HEIGHT ACCESSIBLE FROM SINK
CABINET(TYP.)
A
2' - 2 1/4"
3
-
TW
LWV
TW
ICW
PW
PW
LWV
IHW
IHWICW
IHW
ICW
8
TW(EW)
2. PIPE CLAMPS AND ASSEMBLIES
PROVIDED BY PIPING AND CONDUIT
INSTALLERS.
LV
PW
PW
1. SERVICES & SIZES VARY, REFER
TO LABORATORY PLUMBING
PLANS & DETAILS.
LG
4 1/4"
2 3/8"
LWV
LV
1 7/8"
LA
NOTES:
2
2
WALL BENCH CONDITION
1
1
PIPE DROP ENCLOSURE PER
DIVISION 11
PW
C
2
LA
WALL
H
UNISTRUT P4000 ANCHORED TO
WALL PER DIV. 22
3
LG
ONE OR TWO PIECE PIPE/CONDUIT CLAMP
WITH ELASTOMERIC ISOLATION MATERIAL.
SIZE TO FIT PIPE/CONDUIT BEING
SUPPORTED. "STRUT" TYPE CHANNEL
BRACKET (BY DIVISION 11)
11
℄
NOTES:
1. SERVICES AND ARRANGEMENT
MAY VARY REFER TO LABORATORY
PLUMBING PLANS
7
18"
LW
8
"STRUT" TYPE BRACKET
ANCHORED TO WALL
5
9
8 FT. HIGH PRESSURE REINFORCED
PVC HOSE, INSTALL WITH COIL LOOP
IN SINK CABINET, FREE OF CONTACT
AND BINDING WITH OBJECTS
7
10
BACK FLOW PREVENTER BY DIV 11,
CLAMPED ON THE BACK BOARD BY
DIV. 22
11
1/2" PW BALL VALVE BY DIV 22
10
3
LW
ICW
ONE OR TWO PIECE PIPE/CONDUIT
CLAMP WITH ELASTOMERIC
ISOLATION MATERIAL. SIZE TO FIT
PIPE/CONDUIT BEING SUPPORTED.
4
6
9
LW
IHW
C
BELOW BENCH SUPPORT RACK
1 1/2" = 1'-0"
4 TYPICAL WALL PIPE DROP ENCLOSURE
3" = 1'-0"
SECTION A
C
Construction
Documents
2. REFER TO DETAIL #9/LP-301
FOR PW VERTICAL PIPING LOOP
AT LABORATORY SINK
5 TYPICAL PIPING AT LABORATORY SINK
1" = 1'-0"
6
B
B
2
1-1/4" TW SUPPLY
3
SAFETY SHOWER SUPPLIED PER
DIV. 11 INSTALLED PER DIV. 22
4
1 1/2" P-TRAP CONNECTED TO
WASTE AND VENT SYSTEM.
PROVIDE ACCESS PANEL FOR
P-TRAP.
84"A.F.F.
3
4
PW
TW
ICW
8
4
2
1/2" TW SUPPLY TO EYEWASH
4
1
LV
1" TW SUPPLY TO SAFETY SHOWER
IHWR
7
IHW
REMOVABLE SHOWER VALVE
ACCESS PANEL
ICW
6
℄
PW
RECESSED EYEWASH AT WALL SUPPLIED
PER DIV. 11 INSTALLED PER DIV. 22
7
2
A
6"
2
LA
3
1
LG
5
6
-
PW
10
5
TW
1
15
9
INSTANT ACTION BALL VALVE
IHWR
5
4
8
10
ESCUTCHEON
PW
11
1-1/2" P-TRAP CONNECTED TO WASTE
AND VENT SYSTEM. PROVIDE ACCESS
PANEL FOR P-TRAP.
PW
9
12
1
LA
REMOVABLE DRAIN ACCESS PANEL
3" SPACING
BETWEEN
PIPES, TYP.
LV
13
DRAIN PAN
6
A
12
15
11
POINT OF CONNECTION TO 2"
LABORATORY WASTE AT 6" ABOVE
FINISHED FLOOR, REFER TO
P-SERIES DRAWINGS
CONNECTION TO PW SERVICE
MINIMIZE DEAD LEG
4
SERVICE FITTING MOUNTED
ON FIXED SIDE OF PIPE
DROP ENCLOSURE BY
DIVISION 11/12 (REFER TO
PLANS FOR LOCATIONS)
Mark
2
UNISTRUT PIPE SUPPORT
3
PIPE INSULATION
℄
2
6
2
4
PURIFIED WATER PIPING LINEAR SUPPORT
1/2" FEMALE NPT X 3/8"
O.D. COMPRESSION
ADAPTOR
7 POC PIPING SUPPORT DETAIL
3
3/4" = 1'-0"
4
Description
Date
September 11, 2015
Project Number
14400
Drawn By
3/8" O.D. COMPRESSION X
3/8" O.D. COMPRESSION
ELBOW ADAPTOR
A
NOTE:
FLOOR PW LOOP DROPPED IN
PIPE DROP ENCLOSURE PER
DIV. 22 P-SERIES DRAWINGS.
ELEVATION
3/4" = 1'-0"
Date
RI
Checked By
BS/PL
Copyright ©
NOTES: SERVICES MAY VARY, REFER TO
PLANS & POC SCHEDULE.
NOTE:
DETAIL IS SHOWN DIAGRAMMATICALLY.
PIPING SHALL BE MAINTAINED WITHIN
WALL AND CEILING SPACE.
2
3
5
14
1
PW SHUT OFF VALVE, INSTALL
WITHIN SINK CABINET FOR
ACCESS
3
LABORATORY PLUMBING PIPE SERVICE,
SIZES PER POINT OF CONNECTION
SCHEDULE, REFER TO LP-001
PLAN VIEW
POINT OF CONNECTION TO 1-1/2"
LABORATORY WASTE VENT AT 6"
ABOVE FINISHED CEILING REFER TO
P-SERIES DRAWINGS
PIPING AT SAFETY SHOWER/RECESSED EYEWASH UNIT
2
18"
14
SERVICE FITTING AS SHOWN
ON LF-SERIES DRAWINGS.
REFER TO SCHEDULE
DRAWING LP-001
ELEVATION
4
LG
5
13
1
PW
IHW
-
C:\Users\rilao\Documents\LP-NMSU-JETT HALL-2015_romelrfd.rvt
2
SINGLE PIPE HANGER TO
STRUCTURE ABOVE
PW
1
9/14/2015 1:28:37 PM
N
GI 9/11/15
Jett Hall and Jett Annex
Renovations and
Additions
NOTES:
1. SERVICES MAY VARY, REFER
TO PLANS & SCHEDULES
ELEVATION
N AL E N
New Mexico State
University
1
2. COORDINATE PIPING INSTALLATION
WITH DIVISION 11 SHOP SUBMITTALS
S IO
PROJECT
4
4
ES
F
POINT OF CONNECTION TO 2"
LABORATORY WASTE AT 6"
ABOVE FINISHED FLOOR, REFER
TO P-SERIES DRAWINGS
EE
P RO
1
R
18351
5
SHEET TITLE
LAB PLUMBING
DETAILS
SECTION A
8 PIPING PW VERTICAL PIPING LOOP AT LABORATORY SINK
1" = 1'-0"
6
VAN H. GILBERT ARCHITECT PC
9
LP-301
SHEET
5
105
OF
187
6
1
2
3
4
5
6
Van H. Gilbert Architect PC
ARCHITECTURE • INTERIORS • PLANNING
6
2
2
4
WALL
WALL
5
1
1
2
POINT OF CONNECTION TO 2"
LABORATORY WASTE AT 6" ABOVE
FINISHED FLOOR. REFER TO
P-SERIES DRAWINGS.
4
1
5
1
POINT OF CONNECTION TO PREPIPED HOOD SERVICES.
3
1
4
HOOD PLAN VIEW
1
2
3
LV
LA
LG
ICW
HOOD PLAN VIEW W/ 3" CHASE SPACE
PRE-PIPED WET & DRY SERVICE SUPPLIES TO HOOD
SERVICES MAY VARY, REFER TO PLANS FOR TYPES.
5
LABORATORY WASTE AND VENT RISER LOCATED
WITHIN WALL.
PIPED SERVICES LOCATED IN WALL TO FEED
ADJACENT BENCH SERVICE FITTINGS. REFER TO
PLANS FOR WHERE OCCURS.
4
POINT OF CONNECTION TO CUP
SINK TAILPIECE.
POINT OF CONNECTION TO 1-1/2"
LABORATORY VENT @ 6" ABOVE
FINISHED CEILING.
5
1-1/2" P-TRAP.
6
LABORATORY WASTE AND VENT
RISER BEHIND HOOD IN 3" CHASE
OR IN WALL. REFER TO PLANS
FOR LOCATIONS.
LV
LA
LG
ICW
POINT OF CONNECTION TO 2"
LABORATORY WASTE AT 6" ABOVE
FINISHED FLOOR. REFER TO
P-SERIES DRAWINGS.
2
POINT OF CONNECTION TO
PRE-PIPED HOOD SERVICES
3
POINT OF CONNECTION TO
CUPSINK TAILPIECE
CONSULTANTS
LABORATORY CONSULTANT
RFD - Research Facilities Design
3965 Fifth Ave. Suite 400
San Diego, CA 92103
Phone 619-297-0159
CIVIL ENGINEER
Lilley Engineering, Inc.
5160 Calle Bellisima
Las Cruces, NM 88011
Phone 575-521-0006
4
POINT OF CONNECTION TO
1-1/2" LABORATORY VENT @ 6"
ABOVE FINISHED CEILING
5
1-1/2" P-TRAP
6
WASTE AND VENT RISER BEHIND HOOD
6
STRUCTURAL ENGINEER
Stubbs Engineering, Inc.
277 E. Amador Ave. Suite 200
Las Cruces, NM 88001
Phone 575-993-5228
LV
LA
LG
ICW
2
NOTES:
2. REFER TO SCHEDULES FOR PIPE
SIZES. REFER ALSO TO DETAIL #1/LP-302
3
1
5
3. PIPING SHOWN DASHED IS PART
OF PRE-PIPED FUME HOOD PER
DIVISION 11.
PIPED SERVICES BEHIND HOOD IN 3" CHASE TO FEED
ADJACENT BENCH SERVICE FITTINGS. REFER TO
PLANS FOR WHERE OCCURS.
1. SERVICES MAY VARY, REFER TO PLANS
LV
LA
LG
MECHANICAL/ELECTRICAL ENGINEER
Bridgers & Paxton Consulting Engineers
4600-C Montgomery Blvd. NE
Albuquerque, NM 87109
Phone 505-883-4111
2. REFER TO SCHEDULES FOR PIPE
SIZES. FOR TYPICAL HOOD TOP PLAN,
REFER TO DETAIL #1/LP-302
4. PIPING SHOWN SOLID TO BE
PROVIDED UNDER DIVISION 22.
3. PIPING SHOWN DASHED TO BE
PROVIDED UNDER DIVISION 11
NOTE:
WASTE PENETRATION LOCATIONS MAY REQUIRE
OFFSET TO AVOID STRUCTURAL BEAMS,
REFER TO P-SERIES DRAWINGS.
4. PIPING SHOWN SOLID TO BE PROVIDED
UNDER DIVISION 22
5. P-TRAP, P-TRAP ARM AND ELBOW BENDS
TO CUPSINK TO BE LOCATED WITHIN SIDE
PANEL OF FLOOR MOUNTED HOOD
D
1 TYPICAL PIPING AT CHEMICAL FUME HOOD
SCALE: NTS
2 TYPICAL PIPING AT FLOOR MOUNTED HOOD
1/2" = 1'-0"
3
R. LEMES
L
U
M EXI
W
CO
PA
SCALE: NTS
D
E
TR
TYPICAL PIPING AT CHEMICAL FUME HOOD - PLAN
1
2
5
LOCATION OF LABORATORY WASTE AND VENT RISER
LOCATED BEHIND HOOD IN 3" CHASE. REFER TO
PLANS FOR WHERE OCCURS.
6
E
NOTES:
1. SERVICES MAY VARY, REFER TO PLANS.
3
3" FILLER PANEL/CHASE PROVIDED PER DIVISION 11.
REFER TO LF PLANS FOR LOCATIONS.
4
6
LV
LA
LG
ICW
NE
3
1
6"
E
LV
LA
LG
ICW
2428 Baylor Dr SE Albuquerque, NM 87106
Tel 505-247-9955 Fax 505-247-1826
E-mail [email protected]
Web Site www.vhgarchitect.com
F
ES
EE
P RO
R
18351
S IO
N AL E N
N
GI 9/11/15
PROJECT
4
2
98" A.F.F.
1
1
BIOLOGICAL SAFETY CABINET.
2
BSC WALL MOUNTED
POINT OF CONNECTION
SHUT-OFF VALVE
3
4
1
3
SERVICE FITTINGS AS SHOWN
ON LF-SERIES DRAWINGS.
REFER TO SCHEDULE DRAWING
LP-001
2
1
1
CABLE TRAY BY DIVISION 11
2
LOCATE PIPES TO DROP ON CABLE
TRAY BEARING SURFACE
3
SERVICE FITTINGS AS SHOWN ON
LF-SERIES DRAWINGS. REFER TO
SCHEDULE DRAWING LP-001
"A"
PIPING WITHIN BIOLOGICAL
SAFETY CABINET CHASE TO
SERVICE FITTING
2
FINISHED WALL
FLEX PIPE CONNECTOR
3
FLAT BRACKET SECURED TO
WALL STRUCTURE, SOLDER PIPE
TO BRACKET
54" TYP. - U.O.N.
C
2
1
3
NOTES:
1. NUMBER OF SERVICES
MAY VARY, REFER TO PLANS.
4
New Mexico State
University
Jett Hall and Jett Annex
Renovations and
Additions
UNISTRUT PIPE CLAMPS
NOTE:
SERVICES & ARRANGEMENTS
MAY VARY REFER TO PLANS &
SCHEDULES
NOTE:
SERVICES & ARRANGEMENTS
MAY VARY REFER TO PLANS
& SCHEDULES
C
"A"
PLAN VIEW
2. OFOI BSC MAY NOT BE
PRE-PIPED.
FINISHED FLOOR
Construction
Documents
4
3
SECTION
ELEVATION
1" = 1'-0"
4 PIPING AT WALL MOUNTED FITTING
1" = 1'-0"
5 PIPING @ OVERHEAD SERVICE CARRIER WITH CABLE TRAY
6
B
3
2
1
14
PW
CA
1
IHW SUPPLY
2
3
UNION (TYPICAL)
MPS
5
7
STEAM GENERATOR DRAIN.
ROUTE TO FLOOR SINK
8
INTEGRAL STEAM GENERATOR
FLOOR SINK
SEE P-DRAWINGS
7
15
2
CHANGEOVER ENCLOSURE W/
HEATER AND ANNUNCIATOR
3
HIGH PRESSURE HEADER
4
BANK SHUT-OFF VALVE, TYP.
5
PIGTAIL
6
CHECK VALVE
7
GAS CYLINDERS OFOI
8
CYROGENIC CYLINDER - OFOI
9
1"ø MANIFOLD RELIEF EXHAUST PIPE, CONNECTED
TO LABORATORY EXHAUST DUCTWORK
10
CYLINDER RESTRAINT BY DIV. 11
11
POWER SOURCE (IF REQUIRED)
12
ANNUNCIATOR
13
THREADED CONNECTOR ON END
OF RELIEF EXHAUST PIPE
14
THREAD-O-LET FITTING WELDED
TO EXHAUST DUCT
9
3
IHW ISOLATION VALVE
4
DRAIN TO FLOOR SINK.
REFER TO LP AND PLUMBING PLANS
5
GLASSWARE WASHER
6
WATER GAUGE
7
ICW ISOLATION VALVE
VENT TO DUCT CONNECTION DETAIL
2
6
11
7
8
TO DISTRIBUTION
SYSTEM
12
11
1
4
CA SUPPLY W/ ISOLATION VALVE
2
3
9
PW PIPING LOOP BY DIV. 22.
REFER TO LP-SERIES DWG FOR CONTINUATION
10
PW SUPPLY W/ ISOLATION VALVE
11
WATER PRESSURE REGULATOR
5
5
6
WATER HAMMER ARRESTER.
4
NOTES:
1. ICW & IHW SOURCE SUPPLIES PROVIDED
FROM BACK FLOW PROTECTED WATER
SYSTEM.
6
7
8
FLOOR SINK
SEE P-DRAWINGS
3
6
11
3
FLOW DIAGRAM
2. PIPE SIZES, SERVICES AND LOCATIONS
OF CONNECTIONS MAY VARY. REFER TO
PLANS, SCHEDULES AND
MANUFACTURER'S REQUIREMENTS.
SCALE: NTS
2
Mark
3
SCALE: NTS
4
15
September 11, 2015
14400
Drawn By
RELIEF EXHAUST PIPE CONNECTOR SCREWED
INTO THREAD-O-LET. PROVIDE TEFLON TAPE ON
CONNECTOR THREADS
A
RI
Checked By
BS/PL
Copyright ©
NOTES:
1. NOT ALL MANIFOLD COMPONENTS ARE SHOWN.
REFER TO DIVISION 22 SPECIFICATIONS.
8 CYLINDER MANIFOLD AT CRYOGENIC CYLINDERS
5
Description
Project Number
LAB PLUMBING
DETAILS
SCALE: NTS
6
VAN H. GILBERT ARCHITECT PC
SHEET TITLE
3. NUMBER OF CYLINDERS MAY VARY,
REFER TO PLANS.
7 PIPING AT GLASSWARE WASHER
Date
Date
2. PROVIDE MOUNTING/BRACKETING HARDWARE
FOR AFFIXING UNIT TO WALL.
3. ROUTE STEAM RELIEF VALVE TO FLOOR
SINK.
PIPING AT AUTOCLAVE
1
1
ICW
5
CHAMBER DRAIN. ROUTE TO FLOOR SINK
5
6
WATER HAMMER ARRESTER
9
IHW
PRESSURE REGULATOR (TYPICAL)
9
2
STRAINER (TYPICAL)
4
6
PIPE UNION (TYPICAL)
PRESSURE GAUGE (TYPICAL)
10
8
SYSTEM SHUT-OFF VALVE
13
PW
8
SHUT-OFF VALVE (TYPICAL)
1
60"A.F.F.
9
CA SUPPLY
A
1
EXHAUST DUCT
ICW SUPPLY
C:\Users\rilao\Documents\LP-NMSU-JETT HALL-2015_romelrfd.rvt
3/4" = 1'-0"
9
4
9/14/2015 1:28:40 PM
SECTION "A"-"A"
3
PIPING AT BIOLOGICAL SAFETY CABINET
B
ELEVATION
9
LP-302
SHEET
6
106
OF
187
6
1
2
3
4
5
6
Van H. Gilbert Architect PC
ARCHITECTURE • INTERIORS • PLANNING
8
7
1
LABORATORY GAS POINT OF CONNECTION
2
LABORATORY GAS DISTRIBUTION FROM
POINT OF CONNECTION
3
GAS DISTRIBUTION PIPING TO LABORATORY
SERVICES (REFER TO PLANS FOR ROUTING)
1
1
E
2
FINISHED WALL
5
5.5" WIDE x 5.5" TALL VISION PANEL
6
WALL BOARD FRAME
7
16 GAUGE STEEL VALVE BOX, BAKED
WHITE ENAMEL FINISH, 12"x12"x4" DEEP
5
2-PIECE BRASS BALL VALVE WITH BRASS
TRIM AND THREADED ENDS. UL LISTED AND
AGA/CGA CERTIFIED FOR NATURAL GAS
SERVICE. VALVE HANDLES TO BE INSTALLED
HORIZONTAL TO EXTEND OUT OF VALVE BOX.
9
PIPE & VALVE TO BE MOUNTED IN CENTER
OF VALVE BOX.
10
SMALL PADDLE HANDLE, NON-LOCKING
11
ENGRAVED PLASTIC LABEL. WHITE
LETTERING ON BLACK LABEL.
℄
8
LABORATORY GAS CONTROL VALVE
CLOSE ONLY IN EMERGENCY
10
9
40"
11
FINISHED FLOOR
MOUNTING BRACKET
3
SERVICE FITTING PER DIVISION 11
3
CMU WALL
E
CONSULTANTS
LABORATORY CONSULTANT
RFD - Research Facilities Design
3965 Fifth Ave. Suite 400
San Diego, CA 92103
Phone 619-297-0159
4
CIVIL ENGINEER
Lilley Engineering, Inc.
5160 Calle Bellisima
Las Cruces, NM 88011
Phone 575-521-0006
(24"A.F.F.@ ICW FITTING)
8
6
2
2428 Baylor Dr SE Albuquerque, NM 87106
Tel 505-247-9955 Fax 505-247-1826
E-mail [email protected]
Web Site www.vhgarchitect.com
2
54" TYP.-U.O.N.
3
PIPES BRACKETED TO WALL
3
4
4
PLAN VIEW
1
STRUCTURAL ENGINEER
Stubbs Engineering, Inc.
277 E. Amador Ave. Suite 200
Las Cruces, NM 88001
Phone 575-993-5228
MECHANICAL/ELECTRICAL ENGINEER
Bridgers & Paxton Consulting Engineers
4600-C Montgomery Blvd. NE
Albuquerque, NM 87109
Phone 505-883-4111
NOTES:
ALL EXPOSED PIPING TO BE FREE OF
DEBRIS, OVER SPRAY PAINT AND PIPE DOPE
FOR A NEAT APPEARANCE.
FINISHED FLOOR
ELEVATION
D
SECTION
1 PIPING AT WALL MOUNTED FITTING (EXPOSED)
1" = 1'-0"
2
NOT USED
R. LEMES
L
U
M EXI
W
CO
PA
1" = 1'-0"
E
TR
PIPING AT GAS SHUT-OFF VALVE
NE
D
F
ES
EE
P RO
R
18351
S IO
N AL E N
N
GI 9/11/15
PROJECT
New Mexico State
University
Jett Hall and Jett Annex
Renovations and
Additions
C
C
Construction
Documents
NOT USED
NOT USED
NOT USED
C:\Users\rilao\Documents\LP-NMSU-JETT HALL-2015_romelrfd.rvt
B
B
Mark
Date
Description
Date
A
A
September 11, 2015
Project Number
14400
Drawn By
Author
Checked By
Checker
Copyright ©
VAN H. GILBERT ARCHITECT PC
9/14/2015 1:28:41 PM
SHEET TITLE
LAB PLUMBING
DETAILS
NOT USED
NOT USED
1
2
LP-303
NOT USED
3
4
5
6
SHEET
107
OF
187
6