HSP10-47C HyPerformanceTM Spool, 4-Way

ELECTRO-PROPORTIONAL VALVES—FLOW CONTROL
HSP10-47C HyPerformanceTM Spool, 4-Way,
DESCRIPTION
U.S. Patent
8,253,063
A solenoid-operated, 4-way, 3-position, direct-acting, spool-type, closed center, screwin hydraulic cartridge valve for use in high pressure applications.
OPERATION
When de-energized, the HSP10-47C blocks flow to all ports. When coil #1 is energized, flow is allowed from 3 to 4, and from 2 to 1. When coil #2 is energized, flow is
allowed from 3 to 2, and from 4 to 1.
Manual Override Option: The manual override feature is intended for emergency
use, not continuous operation. For normal valve operation (neutral) the manual override pin must be seated in the center detent groove (ID groove on knob is in-line with
top of coil nut). To shift the valve manually from neutral to activate the S1 coil, push
the knob down slightly, rotate 90 degrees counterclockwise, then pull. To detent in
this position, rotate the knob an additional 90 degrees counterclockwise to lock in the
upper detent groove. To shift manually to activate the S2 coil, push the knob down all
the way. To detent in this position, rotate the knob 90 degrees clockwise to lock in the
lower detent groove.
FEATURES
• Industry-common cavity.
• Efficient wet-armature construction.
• Continuous-duty rated coils.
• Waterproof E-Coils rated up to IP69K.
• Patented high strength solenoid tube.
• All HyPerformance™ products are tested to NFPA specification T2.6.1,
and are tested at a verification level of 90% and an assurance of 99%.
ISO SYMBOL
RATINGS
PERFORMANCE
11.0/160
PRESSURE VS. FLOW
32 sCt oil at 40°C (104°F)
Port 3 to 4
Port 2 to 1
Port 3 to 2
Port 4 to 1
PRESSURE bar/psi
9.7/140
8.3/120
6.9/100
5.5/80
4.1/60
2.8/40
1.4/20
3.8
1.0
7.6
2.0
11.4 15.9
3.0 4.0
18.9 22.7 26.5
5.0 6.0 7.0
FLOW lpm/gpm
FLOW VS. CURRENT
Performance with HEC10-32-160
Pressure Compensating Valve
(Work Ports Looped)
11 bar (160 psi) Compensated
5.5 bar (80 psi) Compensated
Top Coil Energized 3-2 Bottom Coil Energized 3-4
Operating Pressure: 350 bar (5075 psi); 10% Cycle Life: 420 bar (6090 psi)
Note: All HyPerformance™ products are tested for 900K cycles at 350 bar and
100K at 420 bar.
Proof Pressure: 690 bar (10,000 psi)
Burst Pressure: 1380 bar (20,000 psi)
Flow Rating: Up to 26.5 lpm (7 gpm); see performance curves
Maximum Control (Threshold) Current: 1.2 amps for 12 VDC coil
Threshold Current (Nominal) for 12 VDC coil: 0.40 amps
Maximum Internal Leakage: Ports 3 to 1: 10 cu. in./minute (164 ml/min) at 350 bar
(5000 psi) de-energized
Dither Frequency: 100 Hz
Hysteresis: <10% of flow rating between 3.8 to 20.8 lpm (1 to 5.5 gpm)
Temperature: -54° to 107°C (-65° to 225°F) with urethane seals
Fluids: Mineral-based or synthetics with lubricating properties at viscosities
of 7.4 to 420 cSt (50 to 2000 sus); See Temperature and Oil Viscosity, page 9.060.1
Filtration: See page 9.010.1
Installation: No restrictions. See page 9.020.1
Cavity: HVC10-4; See page 9.110.1
Cavity Tool: HCT10-4XX; See page 8.600.1
Seal Kit: SK10-4U-0; See page 8.650.1
Coil Nut: Part No. 4553800
30.3/8
26.5/7
FLOW lpm/gpm
22.7/6
18.9/5
15.9/4
11.4/3
7.6/2
3.8/1
0
1.2
0.8
0.4
0
0.4
0.8
1.2
CURRENT (amps)
2.112.3
®
HYDRAFORCE.com
HYDRAFORCE
®
3-Position, Closed Center
HSP10-47C
DIMENSIONS
PERFORMANCE
U.S. Patent 8,253,063
COIL MUST BE
INSTALLED WITH
LETTERING UP
2.00
50.8
Knob:
FLOW lpm/gpm
Manual Override
Option
"M"
1.62
41.1
1.84
DIA.
46.7
1.50
38.1
1.26
32.0
Option
"B"
5.95
151.1
2.56
65.0
0.75
19.1
ACROSS FLATS
TORQUE:
4–5 ft-lbs
(5.4–6.8 Nm)
Max.
26.5/7
22.7/6
PRESSURE COMPENSATION
Inlet to Work Port (Work Ports Looped)
3-2, S2 Energized
3-4, S1 Energized
18.9/5
15.9/4
1.0
11.4/3
0.8
7.6/2
A
A
0.6 A
3.8/1
60
1000
138
2000
207
3000
276
4000
345
5000
PRESSURE bar/psi
4.57
116.0
1.06
26.9
ACROSS
FLATS
TORQUE
75-85 ft. lbs.
(102-115 Nm)
0.0
0.75
19.1
180
-1.0
3.38
85.7
ORIFICE DISC CANNOT
BE USED WITH THIS PRODUCT
due to HyPerformanceTM Cavity.
Typical Frequency Response Curves
34 bar (500 psi) Inlet Pressure
DC Current, Ports 2 & 4 Looped
S1
S2
-0.5
MAGNITUDE (dB)
2.51
63.8
E-Coil
View
-1.5
135
-2.0
-2.5
90
-3.0
-3.5
-4.0
H-Seris Ductile
Iron Body Shown
45
-4.5
PHASE ANGLE (degrees)
E-Coil
View
-5.0
-5.5
-6.0
TO ORDER
MATERIALS
Cartridge: Weight (without coil and
nut): 0.28 kg. (0.61 lbs.); Steel with
hardened work surfaces. Zincplated exposed surfaces. Urethane
seals without back-up rings
standard.
Ported Body: Weight: 3.97 kg.
(8.75 lbs.); H-series ductile iron
standard. Rated to 345 bar
(5000 psi). See page 8.010.1.
10-Size E-Coil: Weight: 0.41 kg. (0.9
lbs.); Perfect wound, fully encapsulated with rugged external
metal shell. Rated up to IP69K with
integral connectors.
See page 3.400.1.
Option
None(Blank)
Manual Override
Manual Override
with Knob
40.0
0
Voltage
0 Less Coil**
12 12 VDC
24 24 VDC
M
B
**Includes Std. Coil Nut
Consult factory for
additional voltage options.
Porting
Cartridge Only 0
SAE 8 8HT
Seals
PPDI Urethane
Consult factory for
additional seal options.
HYDRAFORCE.com
1.0
10.0
FREQUENCY (Hz)
Signal 50% + 25%
HSP10-47C __ - __ __ __ - __ - __ __ __ __ __
®
0.1
Coil Termination
Deutsch DT04-2P
Metri-Pak 150
Dual Lead Wires
Amp Jr. Timer
DIN 43650
U
ER (IP69K)
EY (IP69K)
EL (IP69K)
EJ (IP67)
EG (IP65)
For Coils with Zener Diode, add “/Z”
to option code. For example: “ER/Z”.
Not available on all models.
See coil option info. on page 3.400.1
2.112.4