Valmet LC Cs (PV) = Elec. T = Status = Valmet Optical Low Consistency Transmitter – Menu structure & key functions 2abc - Output1: Range, damping time, alarm current 3def - Output2: Range, damping time, alarm current 4ghi - Flush time/Meas. time/ Sample wait/ Water meas./Damping 5jkl - Check sensor/TCU type, serial # & SW revisions 7pqr - Set correct date & time to transmitter 8tuv - Set HART or Profibus PA address Valmet LC Optical Low Consistency Transmitter Esc 2abc 3def 1 = Recipe 2 = Sample history 3 = Calibrate 4 = Calib. history 1 - Select recipe 1-4 2abc - Select recipe 1-4 - Enter lab. values - View stored samples 3def - Select recipe 1-4 - Select sample(s) for calculating calibration values 4ghi - Select recipe 1-4 - Shows calibration date & time, constants, calibr. type Calibration Guide 1 = Logs 2 = Diag limits 3 = Water values 4 = Meas values 5 = LED 6 = Current output 1 - Event log - Config trend - Clear logs 2abc - Diagnostic limits 3def - LED values in water 4ghi - Measured values 5jkl - LED current 6mno - mA loop test - Trim mA - Tag no. / Temp unit / Cs unit 6mno = 12.97mA = 8.01 mA K12345 V1.1 EN © Valmet Automation Inc., May 2015. All rights reserved. 1 = Configuration 2 = Calibration 3 = Diagnostics 1 = Recipe selection 2 = Output signal1 3 = Output signal2 4 = Measurement 5 = User settings 6 = Device info 7 = Set clock 8 = Address - Select recipe 1-4 - Remote recipe control mA PV mA SV Enter Esc 1 1 Recipe 1 1.251 %Cs 34.50C OK [1] Edit Save Enter Esc 1 = Configuration 2 = Calibration 3 = Diagnostics Move to next value, scroll function C - Enter lab. values to sensor 1 = Recipe 2 = Sample history 3 = Calibrate 4 = Calib. history Main Menu Move up in menu structure Scroll in display, change values Sample 0 Calibrating: Start editing, change values, save changes 2abc Store values for calibration ... 9wxyz Select menus, edit values 1 = Recipe 2 = Sample history 3 = Calibrate 4 = Calib. history 2abc Calibration Menu A - Select recipe B - Collect lab. sample C - Enter lab. values (Sample history) D - Calculate new calibration (Calibrate) E - Document the calibration values 1 = Configuration 2 = Calibration 3 = Diagnostics 1 Main Menu 1 = Recipe selection 2 = Output signal1 3 = Output signal2 4 = Measurement 5 = User settings 6 = Device info 7 = Set clock 8 = Address Current recipe = 2 1 Output 1 = Cs LRV (4mA) = 0 URV (20mA) = 0.5 Damping = 1 s Alarm curr. = 3.7 mA - Select recipe number: 4ghi 1–4 Edit Save Edit Save Sample Sample Esc -Set measurement and flushing sequence Edit - Save , change value, move to next value with Enter Esc Calibration Menu 3def -Select recipe 1–4 (* indicates active recipe) =1 = 1.0000 = 0.0000 Sample Valmet LC Cs (PV) = Elec. T = Status = Recipe 1 1.251 %Cs 34.50C OK [1] Recipe 1 Press Sample key.. CS = 0.251 Status : WAITING Press Sample key to stop sampling CS = 0.251 Status : SAMPLING Ready 03-05-13 12:35 Average Cs = 0.251 Min: 0.222 Max: 0.264 Sample dev 0.038 Calibration Menu 1 = Recipe 2 = Recipe 3 = Recipe 4 = Recipe - Select recipe 1–4 -[1/2] = one or two point calibration possible -[1] = one point calibr. only -[–] = cannot be calibrated 1 2 3 4 [1/2] * [1] [-] [-] Recipe 1 calibration Select sample 2: Single-point calib. No sample 2. Measurement display -Sample = activate P1 = 1.00 P2 = 0.019 Enter = Accept values Esc = Reject values - Waiting for sampling -Sample = start sampling - Stores average values during sampling -To save: Enter Esc -Find first sample: -Press Enter -For one-point calibration press Enter or - Find second sample: -For two-point calibration press Enter -To accept press Enter - To reject press Esc E - Document -Collect samples for lab. evaluation -Sample = stop sampling -Exit sampling menu: -Press Edit Save -Enter lab. values, save changes: Edit Save -Back to menu: Esc 1 = Recipe 2 = Sample history 3 = Calibrate 4 = Calib. history Recipe 1 calibration Select sample 1: 12.12.2012 15:15:45 Cs= 0.25 Lab= 0.27 B - Collect lab. sample Esc -Set 4mA & 20mA output signal limits and damping time Edit - Save , change value, move to next value with Enter Edit Save Flush time = 30 s Meas. time = 60 m Sample wait = 20 s Water meas. = 30 s Damping = 0.10 1 = Recipe1 * 2 = Recipe2 3 = Recipe3 4 = Recipe4 Recipe P1(gain) P2(offs) Edit Save 1 2abc 1 = Recipe 2 = Sample history 3 = Calibrate 4 = Calib. history -1/4 = sample X of X - Select sample with D - Calculate new calibration A - Select recipe Basic Settings: - Select recipe 1–4 -[X] = number of stored samples per recipe 1 = Recipe1 * 2 = Recipe2 3 = Recipe3 4 = Recipe4 Rec 1 1/4 19.01.2012 15:25:36 Cs = 0.251 %Cs Lab Cs = 0.27 %Cs Steps in Calibration: Calibration Menu 1 = Recipe 2 = Sample history 3 = Calibrate 4 = Calib. history 4ghi 1 = Recipe1 2 = Recipe2 3 = Recipe3 4 = Recipe4 [11] * [ 2] [ 0] [ 0] Calibration Menu - Select recipe 1–4 -Document all settings made for calibration
© Copyright 2026 Paperzz