PSKOVGEOCABLE 1 2 3 КG 1х0,75-30-180 4 № Name of construction Diameter, mm/in Material 1 Conductor Copper, AWG 18, 7х0.37mm (0.75 mm2), Water blocked 1.11/0.04 2 Insulation Tefzel 280 , ∆=0.92 mm (DUPONT trademarks) 2.95/0.118 3 Inner armor 4 Outer armor Steel galvanized wire 12x0.89 mm, grade 190 kg/mm2, water and gas blocking seal Steel galvanized wire 18x0.89 mm, grade 190 kg/mm2, water and gas blocking seal 4.57/0.18 6.35/0.25 MECHANICAL СHARACTERISTIC METRIC ENGLISH Weight in Air Weight in Water Breaking Strength Max Working load @ 60% strain Temperature Rating (Maximum) Suggested Minimum Sheave: Stretch Coefficient (Nominal) 180,2 kg/km 147,5 kg/km 30 kN 18 kN 180˙ C 300 mm 0.5 m/km/kN 120,7 lb/kft. 99 lb/kft 6750 lbf 4050 lbf 356 ˙ F 11,8 “ 2,25 ft/kft/klb dia. Outside Diameter +0,19mm 6.35 mm −0,13mm +0,008" 0.25 " −0,005" ELECTRICAL СHARACTERISTIC Voltage Rating 660VDC D.С Сonductor Resistance 25,5 Ω /km D.С Armor Resistance 10 Ω/km Capacitance @ 1kHz Conductor to Armor 164 pF/m Insulation Resistance (Minimum) @ 500 VDC20000 MΩ*km 660VDC 7.65 Ω/kft 3 Ω/kft 49,2 pF/ft 6500 MΩ*kft www.pskovgeokabel.ru