Gas-insulated switchgear Flexible combination, reliability, availability and economy are the attributes that make it easy for our clients in industry and utilities to decide in favor of products from the ZX series. Together with complete conventional solutions, the use of digital protection and control technology, sensor systems and plug-in connections makes ZX systems unrestrictedly fit for the future, and the primary function of reliable power distribution is fulfilled with no ifs and buts. This is ensured by ABB’s uncompromising approach to quality, which leaves no customer’s wishes unfulfilled. - Systems in metal-enclosed design - Hermetically sealed pressure systems – gas-tight for life! - SF6 insulating gas for guaranteed dielectric strength - Metal partitioning between functions where necessary - Plug-in technology for cables, busbars and voltage transformers - Enclosures in stainless steel - Vacuum circuit-breakers - Factory tested quality A strong family for all situations in life. Aligned to each need, the members of the ZX family offer a solution for each requirement. In over 70 countries the customers rely on gas-insulated switchgears from ABB. Contact us ABB AG Calor Emag Medium Voltage Products Oberhausener Strasse 33 40472 Ratingen, Germany Phone: +49(0)21 02/12-0 Fax: +49(0)21 02/12-17 77 Email: [email protected] ABB AG Calor Emag Medium Voltage Products Petzower Strasse 8 14542 Werder (Havel) OT Glindow, Germany Phone: +49(0)21 02/12-0 +49(0)21 02/12-17 77 Fax: Email: [email protected] Note: We reserve the right to make technical changes or modify the contents of this document without prior notice. With regards to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights to this document and in the subject matter and illustrations contained therein Any reproduction – in whole or in parts – is forbidden without ABB’s prior written consent. DEABB 2435 E (03.09-1000-AMC) ZX-Family Gas-insulated medium voltage switchgear Copyright© 2009 ABB AG All rights reserved. www.abb.com/mediumvoltage ZX-Family Gas-insulated medium voltage switchgear ZX-Family Gas-insulated medium voltage switchgear Your ZX benefit Minimum overall costs Your ZX benefit Safety first 1 14 13 2 12 3 4 10 ZX offers maximum economy ZX ensures maximum operator safety The compact design of the panels reduces the space required and therefore the size of the station. Freedom from maintenance is achieved by constant conditions in the high voltage compartments in conjunction with the selection of suitable materials. As a rule, therefore, isolation of the switchgear to perform maintenance work is not required. The panels are designed for an expected service life of over 40 years. Thanks to the plug-in technology applied in the areas of the busbars, cables and secondary systems, extremely short installation times are possible. No gas work is required as a rule at site. All live components are enclosed to prevent accidental contact. As the high voltage compartments are independent of external influences (degree of protection IP65), the probability of a fault during operation is extremely low. As evidenced by arc fault testing, our switchgear systems are notable for maximum operator safety. A further enhancement can be achieved by providing pressure relief to outside the switchgear room. 9 1 17 16 9 5 8 6 7 Circuit-breaker panel 1250 A 2 3 4 5 15 14 13 Main components of ZX1.2 1 Plug-in voltage transformer 2 Isolating system for voltage transformers 3 Density sensor 4 Circuit-breaker operating mechanism 5 Multifunctional protection and control unit 6 Three-position disconnector operating mechanism 7 Three-position disconnector 8 Busbars 9 Pressure relief disk 10 Pressure relief duct 11 Cable connector 12 Cable socket 13 Measuring sockets for capacitive voltage indicator system 14 Test socket 15 Vacuum circuit-breaker 16 Combined current and voltage sensor or current transformer 17 Plasma diverter 12 ZX0 elements at a glance 1 Multifunctional protection and control unit 2 Measuring sockets for capacitive voltage indicator system 3 Three position disconnector mechanism 4 Circuit-breaker mechanism 5 Cable connector 6 Ring-type current transformer 7 Voltage transformer 8 VT isolating system 9 Pressure relief plate 10 Outer cone 11 Vacuum circuit-breaker 12 Three-position disconnector 13 Busbars 14 Plug-in busbar voltage transformers 11 Your ZX benefit Maximum availability 11 6 7 8 10 9 Feeder 2000 A Easy, simple and fast 10 The plug-in busbar technology without screw couplings permits simple and therefore safe assembly. In spite of the extremely low failure probability of the ZX switchgear systems, replacement of components in the gas compartments and therefore a rapid return to service after repairs is possible. In gas-insulated switchgear, earthing of switchgear sections is performed by a high quality vacuum circuit-breaker. The circuit-breaker can close onto a short-circuit significantly more frequently and reliably than a positively making earthing switch. 1 9 7 8 6 5 13 14 3 10 9 4 15 12 11 2 Double busbar panel for 2000 A ZX0 ZX1.2 ZX2 Compact system for distribution applications in two basic versions: block and individual panel design. Installation against a wall. Both local manual operation and remote control are facilitated. Together with vacuum circuit-breakers, there are switch-disconnectors with and without fuses. Metal partitioned single busbar system for transformer and distribution substations with raised cable terminations for ultra-simple cable installation from the rear. All switching devices can be remote controlled and optionally mechanically interlocked. Metal partitioned single or double busbar system for all applications – even with the highest parameters. Cables accessible from the rear. All switching devices can be remote controlled and optionally mechanically interlocked. Both combined protection and control devices and pure protection devices are used. IEC Ratings Maximum operating voltage kV 12 Test voltages kV 28/75 Rated frequency Hz 50/60 50/60 Rated busbar current A ...1250 ...1250 ...1250 Rated busbar current Rated current of feeder with CB A ...1250 ...1250 ...1250 Rated current of feeder Rated current of feeder with load break switch A ...630 ...630 ...630 Rated peak withstand current kA Rated peak withstand current kA ...62.5 ...62.5 ...62.5 Rated short-time current, 3s kA Rated short-time current, 3s kA ...25 ...25 ...25 Internal Arc Classification IAC AFL 25 kA 1s 50/60 1) 17.5 IEC Ratings kV 1) 12 Rated voltage Rated voltage kV 17.5 24 Maximum operating voltage kV 17.5 24 36 40.5 38/95 50/125 Test voltages kV 38/95 50/125 70/170 85/185 Rated frequency Hz 50/60 50/60 50/60 50/60 A …2500 …2500 …2500 …2500 A 630 12/17.5 1250 ...2500 630 62.5 …80 62.5 25 …31.5 Internal Arc ClassificationIAC AFLR 31.5 kA 1s 1) acc. to IEC 62271-200 | 2) 25 24 Special Ratings 24 1250 ...2500 …80 …31.5 36 1250 ...2500 …80 …31.5 ZX2 key elements 1 Plug-in voltage transformer - busbar 2 Plug-in voltage transformer - outgoing feeder 3 Density sensor 4 Circuit-breaker operating mechanism 5 Multifunctional protection and control unit 6 Three-position disconnector operating mechanism 7 Three-position disconnector 8 Busbars 9 Pressure relief disk 10 Pressure relief duct 11 Cable connector 12 Cable socket 13 Measuring sockets for capacitive voltage indicator system 14 Vacuum circuit-breaker 15 Combined current and voltage sensor or current transformer IEC Ratings Rated voltage kV 12/17.5 24 Special Ratings 36 Maximum operating voltage kV Test voltages kV Rated frequency Hz 50/60 50/60 50/60 50/60 A …2500 …2500 …2500 …2500 Rated busbar current 2) A 630 24 36 40.5 50/125 70/170 85/185 1250 ...2500 630 1250 . ..2500 …80 Rated peak withstand curren kA 62.5 …100 62.5 …100 …100 …100 …31.5 Rated short-time current, 3s kA 25 …40 25 …40 …40 …40 1250 ..2500 Rated current of feeder 2) 17.5 38/95 Internal Arc ClassificationIAC AFLR 40 kA 1s 1) 2) with pressure relief duct 1) 1250 ...2500 1250 ...2500 1) acc. to IEC 62271-200 | 2) Single busbar systems up to 4000 A on request acc. to IEC 62271-200 ZX-Family Gas-insulated medium voltage switchgear ZX-Family Gas-insulated medium voltage switchgear ZX-Family Gas-insulated medium voltage switchgear Your ZX benefit Minimum overall costs Your ZX benefit Safety first 1 14 13 2 12 3 4 10 ZX offers maximum economy ZX ensures maximum operator safety The compact design of the panels reduces the space required and therefore the size of the station. Freedom from maintenance is achieved by constant conditions in the high voltage compartments in conjunction with the selection of suitable materials. As a rule, therefore, isolation of the switchgear to perform maintenance work is not required. The panels are designed for an expected service life of over 40 years. Thanks to the plug-in technology applied in the areas of the busbars, cables and secondary systems, extremely short installation times are possible. No gas work is required as a rule at site. All live components are enclosed to prevent accidental contact. As the high voltage compartments are independent of external influences (degree of protection IP65), the probability of a fault during operation is extremely low. As evidenced by arc fault testing, our switchgear systems are notable for maximum operator safety. A further enhancement can be achieved by providing pressure relief to outside the switchgear room. 9 1 17 16 9 5 8 6 7 Circuit-breaker panel 1250 A 2 3 4 5 15 14 13 Main components of ZX1.2 1 Plug-in voltage transformer 2 Isolating system for voltage transformers 3 Density sensor 4 Circuit-breaker operating mechanism 5 Multifunctional protection and control unit 6 Three-position disconnector operating mechanism 7 Three-position disconnector 8 Busbars 9 Pressure relief disk 10 Pressure relief duct 11 Cable connector 12 Cable socket 13 Measuring sockets for capacitive voltage indicator system 14 Test socket 15 Vacuum circuit-breaker 16 Combined current and voltage sensor or current transformer 17 Plasma diverter 12 ZX0 elements at a glance 1 Multifunctional protection and control unit 2 Measuring sockets for capacitive voltage indicator system 3 Three position disconnector mechanism 4 Circuit-breaker mechanism 5 Cable connector 6 Ring-type current transformer 7 Voltage transformer 8 VT isolating system 9 Pressure relief plate 10 Outer cone 11 Vacuum circuit-breaker 12 Three-position disconnector 13 Busbars 14 Plug-in busbar voltage transformers 11 Your ZX benefit Maximum availability 11 6 7 8 10 9 Feeder 2000 A Easy, simple and fast 10 The plug-in busbar technology without screw couplings permits simple and therefore safe assembly. In spite of the extremely low failure probability of the ZX switchgear systems, replacement of components in the gas compartments and therefore a rapid return to service after repairs is possible. In gas-insulated switchgear, earthing of switchgear sections is performed by a high quality vacuum circuit-breaker. The circuit-breaker can close onto a short-circuit significantly more frequently and reliably than a positively making earthing switch. 1 9 7 8 6 5 13 14 3 10 9 4 15 12 11 2 Double busbar panel for 2000 A ZX0 ZX1.2 ZX2 Compact system for distribution applications in two basic versions: block and individual panel design. Installation against a wall. Both local manual operation and remote control are facilitated. Together with vacuum circuit-breakers, there are switch-disconnectors with and without fuses. Metal partitioned single busbar system for transformer and distribution substations with raised cable terminations for ultra-simple cable installation from the rear. All switching devices can be remote controlled and optionally mechanically interlocked. Metal partitioned single or double busbar system for all applications – even with the highest parameters. Cables accessible from the rear. All switching devices can be remote controlled and optionally mechanically interlocked. Both combined protection and control devices and pure protection devices are used. IEC Ratings Maximum operating voltage kV 12 Test voltages kV 28/75 Rated frequency Hz 50/60 50/60 Rated busbar current A ...1250 ...1250 ...1250 Rated busbar current Rated current of feeder with CB A ...1250 ...1250 ...1250 Rated current of feeder Rated current of feeder with load break switch A ...630 ...630 ...630 Rated peak withstand current kA Rated peak withstand current kA ...62.5 ...62.5 ...62.5 Rated short-time current, 3s kA Rated short-time current, 3s kA ...25 ...25 ...25 Internal Arc Classification IAC AFL 25 kA 1s 50/60 1) 17.5 IEC Ratings kV 1) 12 Rated voltage Rated voltage kV 17.5 24 Maximum operating voltage kV 17.5 24 36 40.5 38/95 50/125 Test voltages kV 38/95 50/125 70/170 85/185 Rated frequency Hz 50/60 50/60 50/60 50/60 A …2500 …2500 …2500 …2500 A 630 12/17.5 1250 ...2500 630 62.5 …80 62.5 25 …31.5 Internal Arc ClassificationIAC AFLR 31.5 kA 1s 1) acc. to IEC 62271-200 | 2) 25 24 Special Ratings 24 1250 ...2500 …80 …31.5 36 1250 ...2500 …80 …31.5 ZX2 key elements 1 Plug-in voltage transformer - busbar 2 Plug-in voltage transformer - outgoing feeder 3 Density sensor 4 Circuit-breaker operating mechanism 5 Multifunctional protection and control unit 6 Three-position disconnector operating mechanism 7 Three-position disconnector 8 Busbars 9 Pressure relief disk 10 Pressure relief duct 11 Cable connector 12 Cable socket 13 Measuring sockets for capacitive voltage indicator system 14 Vacuum circuit-breaker 15 Combined current and voltage sensor or current transformer IEC Ratings Rated voltage kV 12/17.5 24 Special Ratings 36 Maximum operating voltage kV Test voltages kV Rated frequency Hz 50/60 50/60 50/60 50/60 A …2500 …2500 …2500 …2500 Rated busbar current 2) A 630 24 36 40.5 50/125 70/170 85/185 1250 ...2500 630 1250 . ..2500 …80 Rated peak withstand curren kA 62.5 …100 62.5 …100 …100 …100 …31.5 Rated short-time current, 3s kA 25 …40 25 …40 …40 …40 1250 ..2500 Rated current of feeder 2) 17.5 38/95 Internal Arc ClassificationIAC AFLR 40 kA 1s 1) 2) with pressure relief duct 1) 1250 ...2500 1250 ...2500 1) acc. to IEC 62271-200 | 2) Single busbar systems up to 4000 A on request acc. to IEC 62271-200 ZX-Family Gas-insulated medium voltage switchgear ZX-Family Gas-insulated medium voltage switchgear ZX-Family Gas-insulated medium voltage switchgear Your ZX benefit Minimum overall costs Your ZX benefit Safety first 1 14 13 2 12 3 4 10 ZX offers maximum economy ZX ensures maximum operator safety The compact design of the panels reduces the space required and therefore the size of the station. Freedom from maintenance is achieved by constant conditions in the high voltage compartments in conjunction with the selection of suitable materials. As a rule, therefore, isolation of the switchgear to perform maintenance work is not required. The panels are designed for an expected service life of over 40 years. Thanks to the plug-in technology applied in the areas of the busbars, cables and secondary systems, extremely short installation times are possible. No gas work is required as a rule at site. All live components are enclosed to prevent accidental contact. As the high voltage compartments are independent of external influences (degree of protection IP65), the probability of a fault during operation is extremely low. As evidenced by arc fault testing, our switchgear systems are notable for maximum operator safety. A further enhancement can be achieved by providing pressure relief to outside the switchgear room. 9 1 17 16 9 5 8 6 7 Circuit-breaker panel 1250 A 2 3 4 5 15 14 13 Main components of ZX1.2 1 Plug-in voltage transformer 2 Isolating system for voltage transformers 3 Density sensor 4 Circuit-breaker operating mechanism 5 Multifunctional protection and control unit 6 Three-position disconnector operating mechanism 7 Three-position disconnector 8 Busbars 9 Pressure relief disk 10 Pressure relief duct 11 Cable connector 12 Cable socket 13 Measuring sockets for capacitive voltage indicator system 14 Test socket 15 Vacuum circuit-breaker 16 Combined current and voltage sensor or current transformer 17 Plasma diverter 12 ZX0 elements at a glance 1 Multifunctional protection and control unit 2 Measuring sockets for capacitive voltage indicator system 3 Three position disconnector mechanism 4 Circuit-breaker mechanism 5 Cable connector 6 Ring-type current transformer 7 Voltage transformer 8 VT isolating system 9 Pressure relief plate 10 Outer cone 11 Vacuum circuit-breaker 12 Three-position disconnector 13 Busbars 14 Plug-in busbar voltage transformers 11 Your ZX benefit Maximum availability 11 6 7 8 10 9 Feeder 2000 A Easy, simple and fast 10 The plug-in busbar technology without screw couplings permits simple and therefore safe assembly. In spite of the extremely low failure probability of the ZX switchgear systems, replacement of components in the gas compartments and therefore a rapid return to service after repairs is possible. In gas-insulated switchgear, earthing of switchgear sections is performed by a high quality vacuum circuit-breaker. The circuit-breaker can close onto a short-circuit significantly more frequently and reliably than a positively making earthing switch. 1 9 7 8 6 5 13 14 3 10 9 4 15 12 11 2 Double busbar panel for 2000 A ZX0 ZX1.2 ZX2 Compact system for distribution applications in two basic versions: block and individual panel design. Installation against a wall. Both local manual operation and remote control are facilitated. Together with vacuum circuit-breakers, there are switch-disconnectors with and without fuses. Metal partitioned single busbar system for transformer and distribution substations with raised cable terminations for ultra-simple cable installation from the rear. All switching devices can be remote controlled and optionally mechanically interlocked. Metal partitioned single or double busbar system for all applications – even with the highest parameters. Cables accessible from the rear. All switching devices can be remote controlled and optionally mechanically interlocked. Both combined protection and control devices and pure protection devices are used. IEC Ratings Maximum operating voltage kV 12 Test voltages kV 28/75 Rated frequency Hz 50/60 50/60 Rated busbar current A ...1250 ...1250 ...1250 Rated busbar current Rated current of feeder with CB A ...1250 ...1250 ...1250 Rated current of feeder Rated current of feeder with load break switch A ...630 ...630 ...630 Rated peak withstand current kA Rated peak withstand current kA ...62.5 ...62.5 ...62.5 Rated short-time current, 3s kA Rated short-time current, 3s kA ...25 ...25 ...25 Internal Arc Classification IAC AFL 25 kA 1s 50/60 1) 17.5 IEC Ratings kV 1) 12 Rated voltage Rated voltage kV 17.5 24 Maximum operating voltage kV 17.5 24 36 40.5 38/95 50/125 Test voltages kV 38/95 50/125 70/170 85/185 Rated frequency Hz 50/60 50/60 50/60 50/60 A …2500 …2500 …2500 …2500 A 630 12/17.5 1250 ...2500 630 62.5 …80 62.5 25 …31.5 Internal Arc ClassificationIAC AFLR 31.5 kA 1s 1) acc. to IEC 62271-200 | 2) 25 24 Special Ratings 24 1250 ...2500 …80 …31.5 36 1250 ...2500 …80 …31.5 ZX2 key elements 1 Plug-in voltage transformer - busbar 2 Plug-in voltage transformer - outgoing feeder 3 Density sensor 4 Circuit-breaker operating mechanism 5 Multifunctional protection and control unit 6 Three-position disconnector operating mechanism 7 Three-position disconnector 8 Busbars 9 Pressure relief disk 10 Pressure relief duct 11 Cable connector 12 Cable socket 13 Measuring sockets for capacitive voltage indicator system 14 Vacuum circuit-breaker 15 Combined current and voltage sensor or current transformer IEC Ratings Rated voltage kV 12/17.5 24 Special Ratings 36 Maximum operating voltage kV Test voltages kV Rated frequency Hz 50/60 50/60 50/60 50/60 A …2500 …2500 …2500 …2500 Rated busbar current 2) A 630 24 36 40.5 50/125 70/170 85/185 1250 ...2500 630 1250 . ..2500 …80 Rated peak withstand curren kA 62.5 …100 62.5 …100 …100 …100 …31.5 Rated short-time current, 3s kA 25 …40 25 …40 …40 …40 1250 ..2500 Rated current of feeder 2) 17.5 38/95 Internal Arc ClassificationIAC AFLR 40 kA 1s 1) 2) with pressure relief duct 1) 1250 ...2500 1250 ...2500 1) acc. to IEC 62271-200 | 2) Single busbar systems up to 4000 A on request acc. to IEC 62271-200 ZX-Family Gas-insulated medium voltage switchgear ZX-Family Gas-insulated medium voltage switchgear ZX-Family Gas-insulated medium voltage switchgear Gas-insulated switchgear Flexible combination, reliability, availability and economy are the attributes that make it easy for our clients in industry and utilities to decide in favor of products from the ZX series. Together with complete conventional solutions, the use of digital protection and control technology, sensor systems and plug-in connections makes ZX systems unrestrictedly fit for the future, and the primary function of reliable power distribution is fulfilled with no ifs and buts. This is ensured by ABB’s uncompromising approach to quality, which leaves no customer’s wishes unfulfilled. - Systems in metal-enclosed design - Hermetically sealed pressure systems – gas-tight for life! - SF6 insulating gas for guaranteed dielectric strength - Metal partitioning between functions where necessary - Plug-in technology for cables, busbars and voltage transformers - Enclosures in stainless steel - Vacuum circuit-breakers - Factory tested quality A strong family for all situations in life. Aligned to each need, the members of the ZX family offer a solution for each requirement. In over 70 countries the customers rely on gas-insulated switchgears from ABB. Contact us ABB AG Calor Emag Medium Voltage Products Oberhausener Strasse 33 40472 Ratingen, Germany Phone: +49(0)21 02/12-0 Fax: +49(0)21 02/12-17 77 Email: [email protected] ABB AG Calor Emag Medium Voltage Products Petzower Strasse 8 14542 Werder (Havel) OT Glindow, Germany Phone: +49(0)21 02/12-0 +49(0)21 02/12-17 77 Fax: Email: [email protected] Note: We reserve the right to make technical changes or modify the contents of this document without prior notice. With regards to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights to this document and in the subject matter and illustrations contained therein Any reproduction – in whole or in parts – is forbidden without ABB’s prior written consent. DEABB 2435 E (03.09-1000-AMC) ZX-Family Gas-insulated medium voltage switchgear Copyright© 2009 ABB AG All rights reserved. www.abb.com/mediumvoltage ZX-Family Gas-insulated medium voltage switchgear ZX-Family Gas-insulated medium voltage switchgear Gas-insulated switchgear Flexible combination, reliability, availability and economy are the attributes that make it easy for our clients in industry and utilities to decide in favor of products from the ZX series. Together with complete conventional solutions, the use of digital protection and control technology, sensor systems and plug-in connections makes ZX systems unrestrictedly fit for the future, and the primary function of reliable power distribution is fulfilled with no ifs and buts. This is ensured by ABB’s uncompromising approach to quality, which leaves no customer’s wishes unfulfilled. - Systems in metal-enclosed design - Hermetically sealed pressure systems – gas-tight for life! - SF6 insulating gas for guaranteed dielectric strength - Metal partitioning between functions where necessary - Plug-in technology for cables, busbars and voltage transformers - Enclosures in stainless steel - Vacuum circuit-breakers - Factory tested quality A strong family for all situations in life. Aligned to each need, the members of the ZX family offer a solution for each requirement. In over 70 countries the customers rely on gas-insulated switchgears from ABB. Contact us ABB AG Calor Emag Medium Voltage Products Oberhausener Strasse 33 40472 Ratingen, Germany Phone: +49(0)21 02/12-0 Fax: +49(0)21 02/12-17 77 Email: [email protected] ABB AG Calor Emag Medium Voltage Products Petzower Strasse 8 14542 Werder (Havel) OT Glindow, Germany Phone: +49(0)21 02/12-0 +49(0)21 02/12-17 77 Fax: Email: [email protected] Note: We reserve the right to make technical changes or modify the contents of this document without prior notice. With regards to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights to this document and in the subject matter and illustrations contained therein Any reproduction – in whole or in parts – is forbidden without ABB’s prior written consent. DEABB 2435 E (03.09-1000-AMC) ZX-Family Gas-insulated medium voltage switchgear Copyright© 2009 ABB AG All rights reserved. www.abb.com/mediumvoltage ZX-Family Gas-insulated medium voltage switchgear ZX-Family Gas-insulated medium voltage switchgear
© Copyright 2026 Paperzz