Tmax DOC. N.° 1SDH000549R0001 - L7947 Sganciatori PR222DS/P e PR222DS/PD-A T4-T5-T6 UL Release PR222DS/P and PR222DS/PD-A T4-T5-T6 UL Auslöser PR222DS/P und PR222DS/PD-A T4-T5-T6 UL Dèclencheur PR222DS/P et PR222DS/PD-A T4-T5-T6 UL Relé PR222DS/P y PR222DS/PD-A T4-T5-T6 UL A Autoalimentati per corrente monofase >18% In. Self-powered for single-phase current >18% In. Selbstversorgt durch einphasigen Strom > 18 % In. Autoalimentés pour courant monophasé >18% In. Autoalimentados por corriente monofase >18% In. ( ) I1max=In 3s 6s 9s max Test/Prg t1 I=6I1 In x ( I4= ) In x I 0 0 0 0 0 0 0 0 0 S I3= 0.05s 0.1s 0.25s 0.50s t2 I=8In PR222DS/PD-A MAN ELT ) G ON 100 % I>I2 ( 0.2 0.2 5 0.5 5 In x 0 0 0 I2= 1.5 2.5 3 5 ) 0 0 0 0 0.0 2 0.0 4 0.0 8 0.1 6 0.3 2 I1= Test Inx(0.4+ 0.6 1.2 2.4 5.8 B OFF 50 0.1s 0.2s 0.4s 0.8s t4 N MAN Settaggio di default manuale Manual default setting Manuelle Default-Einstellung Configuration par défaut manuelle Ajuste de default manual ELT ( I3= ) In x I1max=In t1 3s 6s 9s max Test/Prg 0.05s 0.1s 0.25s 0.50s I=6I1 I4= ) In x t2 I=8In MAN ON 100 ) ELT t4 0.1s 0.2s 0.4s 0.8s % I>I2 ( G 0 0 0 0 I 0 0 0 0 0 0 0 0 0 S ( 0.2 0.2 5 0.5 5 In x 0 0 0 I2= ) 1.5 2.5 3 5 0.0 2 0.0 4 0.0 8 0.1 6 0.3 2 I1= Test Inx(0.4+ 0.6 1.2 2.4 5.8 C OFF 50 Esempio - Example - Beispiel - Exemple - Ejemplo In = 100A I1 = 100x(0,4+0,08+0,32)=80A t1 = 9s @ 480A (6I1) N PR222DS/PD-A 0.0 2 0.0 4 0.0 8 0.1 6 0.3 2 I1= ) 0 0 0 0 0 Inx(0.4+ In(A) T4 100 150 250 T5 300 400 600 T6 600 800 L Alarm I1>I2 or I2>I3 WINK (PR222DS/PD-A version only) L Prealarm I1(In) 0,4 40 60 100 120 160 240 240 320 0,42 42 63 105 126 168 252 252 336 0,44 44 66 110 132 176 264 264 352 … … … … … … … … … 0,96 96 144 240 288 384 576 576 768 ) Test/Prg t1 I=6I1 ( I4= ) In x I 0.05s 0.1s 0.25s 0.50s t2 I=8In MAN ELT ) G ON 100 % I>I2 ( OFF 50 0.1s 0.2s 0.4s 0.8s I2= t4 In x ( 0.05s 0.1s 0.25s 0.50s In (A) T4 100 150 250 T5 300 400 600 T6 600 800 I2(In) 0,6 60 90 150 180 240 360 360 480 1,2 1,8 2,4 3 120 180 240 300 180 270 360 450 300 450 600 750 360 540 720 900 480 720 960 1200 720 1080 1440 1800 720 1080 1440 1800 960 1440 1920 2400 ) S N PR222DS/PD-A I=6I1 0 0 0 0 3s 6s 9s max In x 0 0 0 0 0 0 0 0 0 S I1max=In I3= 0.2 0.2 5 0.5 5 ( t1 Esempio - Example - Beispiel - Exemple - Ejemplo In = 100A I2 = 100x(0,6+2,4)=300A t2 (I2t=ON) = 0,1s @ 800A (8In) 0 0 0 In x 1.5 2.5 3 5 I2= 0 0 0 0 ) 0.6 1.2 2.4 5.8 0.0 2 0.0 4 0.0 8 0.1 6 0.3 2 I1= 3s 6s 9s max t1 1 max 100 18 150 18 250 18 300 18 400 18 600 10,5 600 18 800 18 0,98 98 147 245 294 392 588 588 784 D Test Inx(0.4+ I1max=In (1 Hz) (0.33 Hz) (4 Hz) 0.6 1.2 2.4 5.8 Normal status 3,6 360 540 900 1080 1440 2160 2160 2880 4,2 420 630 1050 1260 1680 2520 2520 3360 5,8 580 870 1450 1740 2320 3480 3480 4640 t2 I=8In 6,4 640 960 1600 1920 2560 3840 3840 5120 I>I2 7 700 1050 1750 2100 2800 4200 4200 5600 * I2 max T5 600= 9.5 In 7,6 760 1140 1900 2280 3040 4560 4560 6080 8,2 820 1230 2050 2460 3280 4920 4920 6560 8,8 880 1320 2200 2640 3520 5280 5280 7040 9,4 940 1410 2350 2820 3760 5640 5640 7520 10 1000 1500 2500 3000 4000 5700* 6000 8000 ( ) 3s 6s 9s max Test/Prg t1 0.05s 0.1s 0.25s 0.50s I=6I1 ( ) In x t2 ( I=8In MAN ON 100 0.1s 0.2s 0.4s 0.8s % I>I2 ) G 0 0 0 0 I 0 0 0 0 0 0 0 0 0 S I1max=In In x ELT OFF 50 t4 I3= N PR222DS/PD-A Esempio - Example - Beispiel - Exemple - Ejemplo In = 100A I3 = 100x(1,5+3)=450A In x 1 .5 2 .5 3 5 In x I4= 0.2 0.2 5 0.5 5 ) I3= 0 0 0 Test Inx(0.4+ I2= 1.5 2.5 3 5 0.0 2 0.0 4 0.0 8 0.1 6 0.3 2 I1= 0.6 1.2 2.4 5.8 E ( ) 0 0 0 0 I I3(In) In(A) 1,5 T4 100 150 150 225 250 375 T5 300 450 400 600 600 900 T6 600 900 800 1200 2,5 250 375 625 750 1000 1500 1500 2000 3 300 450 750 900 1200 1800 1800 2400 4 400 600 1000 1200 1600 2400 2400 3200 4,5 450 675 1125 1350 1800 2700 2700 3600 5 500 750 1250 1500 2000 3000 3000 4000 5,5 550 825 1375 1650 2200 3300 3300 4400 6,5 650 975 1625 1950 2600 3900 3900 5200 7 700 1050 1750 2100 2800 4200 4200 5600 7,5 750 1125 1875 2250 3000 4500 4500 6000 8 800 1200 2000 2400 3200 4800 4800 6400 9 900 1350 2250 2700 3600 5400 5400 7200 9,5 10,5 12 950 1050 1200 1425 1575 1800 2375 2625 3000 2850 3150 3600 3800 4200 4800 5700 5700* 5700* 5700 6300 7200 7600 8400 8400** * I3 max T5 600= 9.5 In ** I3 max T6 800= 10.5 In ) 3s 6s 9s max I=6I1 PR222DS/PD-A ( I4= ) In x I 0.05s 0.1s 0.25s 0.50s t2 I=8In MAN ELT ) G ON 100 % I>I2 ( OFF 50 0.1s 0.2s 0.4s 0.8s N t4 I4= In x ( ) G 0 0 0 Test/Prg t1 In x 0 0 0 0 0 0 0 0 0 S I1max=In I3= 0.2 0.2 5 0.5 5 ( 0.2 0.2 5 0.5 5 In x Esempio - Example - Beispiel - Exemple - Ejemplo In = 100A I4 = 100x(0,2+0,25)=45A t4 = 0,2s 0 0 0 I2= 1.5 2.5 3 5 ) 0 0 0 0 0.0 2 0.0 4 0.0 8 0.1 6 0.3 2 I1= Test Inx(0.4+ 0.6 1.2 2.4 5.8 F 0.1s 0.2s 0.4s 0.8s In(A) T4 100 150 250 T5 300 400 600 T6 600 800 I4(In) 0,2 0,25 0,45 0,55 0,75 0,8 20 25 45 55 75 80 30 37,5 67,5 82,5 112,5 120 50 62,5 112,5 137,5 187,5 200 60 75 135 165 225 240 80 100 180 220 300 320 120 150 270 330 450 480 120 150 270 330 450 480 160 200 360 440 600 640 1 100 150 250 300 400 600 600 800 t4 I1max=In 3s 6s 9s max Test/Prg t1 I=6I1 MAN ON 100 0.1s 0.2s 0.4s 0.8s % ELT I>I2 OFF 50 t4 I1max=In 3s 6s 9s max Test/Prg ( ) t1 I=6I1 I3= In x ( MAN I4= ) In x I 0.05s 0.1s 0.25s 0.50s t2 I=8In MAN ELT ) G ON 100 % I>I2 ( 0.2 0.2 5 0.5 5 In x OFF 50 0.1s 0.2s 0.4s 0.8s t4 N PR222DS/PD-A ON 100 % ELT OFF 50 Esempio - Example - Beispiel Exemple - Ejemplo Ne=ON; 50% N Settaggio di default elettronico Electronic default setting elektronische Default Einstellung Configuration par défaut électronique Ajuste de default electrónico TEST DI INTERVENTO SGANCIATORE TRIP TEST AUSLÖSEPRÜFUNG DES AUSLÖSERS TEST DE DÉCLENCHEMENT DÉCLENCHEUR PRUEBA DE ACTUACIÓN DEL RELÉ PRESET THIS TEST CAUSES THE BREAKER TRIP SACE TT1 PRESET THIS TEST CAUSES THE BREAKER TRIP Intervento Trip Auslösung Déclenchement Actuación TRIP TEST READY SACE TT1 TRIP TEST POLARITY + - POLARITY + - CLACK! READY I I2= S N 1 x In Max Off 4 x In Off ) 0 0 0 I1= Test Inx(0.4+ ) 1.5 2.5 3 5 ( G 0 0 0 0 t2 I=8In 0.05s 0.1s 0.25s 0.50s PR222DS/PD-A L t1 S I G I4= ) In x I 0 0 0 0 0 0 0 0 0 S ( 0 0 0 0 In x 0 0 0 0 I3= ) 0.0 2 0.0 4 0.0 8 0.1 6 0.3 2 ( 0 0 0 0 0 In x 0.2 0.2 5 0.5 5 I2= 0 0 0 ) 1.5 2.5 3 5 0.0 2 0.0 4 0.0 8 0.1 6 0.3 2 I1= Test Inx(0.4+ 0.6 1.2 2.4 5.8 H 0.6 1.2 2.4 5.8 G Carica - Charge - Ladung - Alimentation Alimentación L Programmazione e Test con Unità PR010/T Programming and test with PR010/T Programmierung und Test mit Einheit PR010/T Programmation et Test avec Unité PR010/T Programación y Test con Unidad PR010/T ) I2= In x ( ) I1max=In 3s 6s 9s max Test/Prg For more information please contact: ABB S.p.A. ABB SACE Division Via Baioni, 35 24123 Bergamo - Italy Phone: +39 035 395 111 Fax: +39 035 395 306 - 433 © Copyright 2005-2014 ABB. All rights reserved. www.abb.com t1 I=6I1 PR222DS/PD-A In x ( I4= ) In x I 0 0 0 0 0 0 0 0 0 S I3= 0.05s 0.1s 0.25s 0.50s t2 I=8In MAN ELT ) G ON 100 % I>I2 ( 0.2 0.2 5 0.5 5 0.0 2 0.0 4 0.0 8 0.1 6 0.3 2 I1= Test Inx(0.4+ 0 0 0 1. 1.5 2.5 3 5 1. 0 0 0 0 1. 1. posizione leva TRIP oppure OFF per TEST con PR010/T C.B. position TRIP or OFF for TEST whit PR010/T Position Hebel TRIP oder OFF für TEST mit PR010/T position du levier TRIP ou bien OFF pour TEST avec PR010/T posición palanca TRIP o bien OFF per TEST con PR010/T 0.6 1.2 2.4 5.8 1. OFF 50 N 0.1s 0.2s 0.4s 0.8s t4
© Copyright 2026 Paperzz