OXYGEN € 2016-2017.EX THE BREATHING RADIATOR: Intelligent and healthy ventilation Jaga Oxygen is not a traditional ventilation system, but an intelligent and energy efficient fresh air system. Oxygen Hybrid Solutions are ready-touse devices (Plug and Play) for ventilation and for heating and cooling. The Oxygen Air Refresh units can be installed separately or integrated into existing Low-H2O radiators. Both the Hybrid Solutions and the Air Refresh Units can be operated via the integrated control unit or via the intelligent central control Green Wire system, developed by Jaga in collaboration with GE. All technical information see www.theoxygenradiator.com 304 € EX - 09/06/16 09/06 9/0 /16 € EX - 09/06/16 305 THE BREATHING RADIATOR: INTELLIGENT AND HEALTHY VENTILATION DIRECT AIR A unique feature is that the incoming air is drawn-in directly from the outside. There is no central supply ducting that branches off to different rooms. Such ducting can be difficult to clean and collects dirt, bacteria and germs. Thanks to a filter system and the intelligent balanced exhaust of stale air, Jaga Oxygen ensures a clean indoor climate. The range of filters ensures that dust and pollen cannot enter. Odours, dust and bacteria are neutralised or removed. Moreover, the built-in sound attenuation stops noise from the outside getting into the room. SAVING ADDITIONAL ENERGY WITH HEAT RECOVERY Heat recovery can be integrated into the system by means of a heat pump that recovers the heat from the extracted polluted air. Jaga also offers a solution for decentralised heat recovery: the Hybrid WTW (WTW = Heat Recovery) contains the Low-H2O heating technology and an Air Refreshing unit with integrated heat recovery. The CO2 sensor and the operating controls are also integrated. The Jaga Hybrid WTW is an easy to install energyefficient appliance for rooms with low occupancy. SAVE ENERGY THROUGH DEMAND CONTROLLED VENTILATION IN EACH ROOM The Jaga Oxygen system ensures perfectly-controlled ventilation. Integrated or zone-specific CO2 sensors and/or humidity meters continuously measure the composition of your indoor air. The smart system determines how much air is drawn in or extracted, and when. Instead of using a standard setting for the whole building, it operates flexibly, according to the requirement of each room. JAGA HYBRID SOLUTIONS: VENTILATION, HEATING AND COOLING IN ONE RADIATOR. Jaga Hybrid Solutions comprises a range of ready-to-use climate radiators for ventilation and heating. The energy-efficient Low-H2O heating technology and Air Refresh units are an ideal combination, providing fresh air and a pleasant temperature without draughts all through the year. The radiator can also be supplemented with a cooling system. All technical information see www.theoxygenradiator.com 306 | jaga Top Performers € EX - 09/06/16 EFFICIENT BOOST FOR HIGH-SPEED VENTILATION the ideal indoor air quality, always and everywhere INTELLIGENT Jaga Oxygen operates fully automatically and actively anticipates measures the air quality and automatically goes into operation whenever required indoor air quality. The system accurately analyses the air quality in the room and the built-in fan quietly draws in the precise AESTHETIC amount of air required to correct the air quality. With the boost invisibly built into your Low-H2O radiator function extra fresh air can be drawn in when required. COMFORTABLE FREE NIGHT COOLING Eliminates draughts almost silently During the warm summer months, the boost function can also HEALTHY be used to draw in cool air at night. This free night cooling does no polluting central supply channels, but direct airflow into each room not have the power of an air conditioner, but refreshes the air in the room in a pleasant manner. The thermal mass of the building SAVING absorbs this cool air and acts as a fridge as the temperature controlled by room, no more unnecessary ventilation begins to rise, and with no active air conditioning, energy cost is much lower. EASY TO USE simple control by room or centrally controlled FREE NIGHT COOLING switching to the boost function in the evening will draw plenty of cold outside air into the room EASE TO INSTALL with individual or central control OXYGEN CAMPUS WITH CENTRAL HEAT RECOVERY 4 1 2 3 1 CO2 sensor measures the air quality 3 The air is uniformly distributed throughout the room using displacement ventilation. 2 Oxygen Campus draws exactly the right amount of fresh air and mixes it with the heated air 4 The heat pump recovers energy from the polluted air and sends it back to the Oxygen radiators. jaga Top Performers € EX - 09/06/16 | 307 A RANGE OF SOLUTIONS FOR HIGH OR LOW OCCUPANCY Jaga Oxygen utility solutions are designed for rooms with high occupancy. These systems have a high ventilation rate, especially for classrooms and offices. The solutions for homes and care homes provide comfortable ventilation in rooms with lower occupancy. All technical information see www.theoxygenradiator.com HIGH OCCUPANCY OXYGEN CAMPUS OXYGEN OFFICE A classic example of demand-controlled ventilation A reliable system with low operating costs The indoor climate in schools has long been an impact issue. A good indoor climate in offices is essential for good work Adequate supply of fresh, clean outside air and removal of efficiency and to reduce absenteeism. Jaga Oxygen Office contaminated indoor air is necessary. Jaga Oxygen Campus combines heating and ventilation functions in a single housing. maintains the CO2 concentration below 1200 ppm (or any level This leads to a significant energy saving. The Green Wire control you choose), while maintaining a low noise level. It is generally system adjusts air quality, humidity and temperature to the installed with a Jaga building management system that actual conditions in each room. It is fully automatic, but users measures and automatically regulates the entire indoor climate. in each room can also easily adjust it. The system can also be All rooms are managed individually. The radiators for educational extended to provide (passive) cooling. and training institutions can be provided with a protective bottom grille. 3 1 1 Air quality measurement in the room. CO2 sensor 2 Air removal of used indoor air. Exhaust unit 3 Air supply of fresh filtered external air Air Refresh unit or Hybrid 4 Control 4 2 308 | jaga Top Performers € EX - 09/06/16 3 LOW OCCUPANCY OXYGEN HOME & CARE With an emphasis on comfort and health 1 In well-insulated care institutions, an excess of CO2 is a common cause of a poor indoor 4 climate. For care institutions, Jaga places the emphasis on comfort and health, with a system that goes beyond mere energy savings. Using Low-H2O technology, the radiators always have a safe contact temperature and provide better heat distribution throughout the room. The ventilation section supplies fresh outside air without draughts, since the fresh air is 1 Air quality measurement in the room. CO2 sensor 2 Air removal of used indoor air. Exhaust unit 3 Air supply of fresh filtered external air Air Refresh unit or Hybrid 4 Control pre-heated to room temperature. CO2 sensors take control and remove the need for manual setting. The system works fully automatically so the residents and staff do not have to learn to operate it. 2 OXYGEN HYBRID WTW Stand-alone ventilation system with heat recovery and Low-H2O radiator. The Jaga Hybrid WTW is a unique combination of a stand-alone ventilation system with heat recovery, and a Low-H2O radiator. The Hybrid WTW is positioned against an outside wall in which two holes are made. The extracted used air transfers its heat to the clean filtered incoming air. This limits the energy loss to an absolute minimum. The radiator is simply connected to the central heating circuit like any other radiator, and the ventilation section is connected to a mains electrical contact. The smart sensors for CO2, humidity and indoor and outdoor temperature measure the air quality and determine the amount NEW COMING SOON of ventilation required. The operation can be adjusted according to personal preferences using the easy-to-understand operation panel. jaga Top Performers € EX - 09/06/16 | 309 Tel.: +32 (0)11 29 41 16 Fax: +32 (0)11 29 41 60 [email protected] The information in this price list is correct at the time of printing. Jaga reserves the right to change product specification at any time in line with our policy of continuous improvement and innovation. All prices in Euro, exclude VAT. Prices valid from 1st August 2016. Replaces all existing price lists. 090616 - JAGA N.V. Jaga International Verbindingslaan z/n B-3590 Diepenbeek
© Copyright 2026 Paperzz