Endress+Hauser InDesign CS2 Template

Condensed Launch
EngyCal® RH33 BTU Meter and
EngyCal® RS33 Steam Calculator
Disclose waste of energy and reduce costs
EngyCal® RH33 and RS33 enable
• Transparency on energy consuming plants and processes
• Sustainability within the energy management
• Process stability through continuous monitoring
Reduce energy costs by up to 8%
with monitoring and analyzing energy
consumption based on reliable and accurate
calculation and measurement instruments.
Proven reduction potential without additional investment
just by an increased awareness and change in behavior.
Open and web based information
Access to information worldwide via the web browser free of charge!
Reduce costs for system integration and information transfer over the
complete life time!
The following information is available:
• measured values (temperature, pressure, mass flow)
• calculated values (energy, enthalpy, Delta T, …)
• alarm and limits
• device and value status
In addition the electronic name plate (showing serial number, tag, etc.)
can be obtained via the web server as well.
Information supply via Field Data Manager software
Consolidates the measured and calculated data,
visualizes the consumption, generates reports
automatically and delivers a tamper-proof
documentation.
Your benefits:
• Target-performance comparison and benchmarking
• Identify and monitor energy intensive process steps
• Create correlations between energy consuming
plants (heat exchanger for process heating) and
energy generators (like boilers)
• Validate invoices - monitor energy usage on
consumer side for comparison purposes
• Automatically create invoices in combination with an
ERP system
Highly accurate measurement technology – calculation according to IAPWS
Endress+Hauser offers a complete portfolio of devices and tools calculating
energy of water and steam according to the international standard IAPWS-97.
IAPWS delivers
an internationally accepted formulation for properties
• light and heavy steam,
• water and
• selected aqueous mixtures
in
• thermal power cycles and
• other industrial applications.
2
www.products.endress.com/energymanager
The BTU Meter EngyCal® RH33
measures the energy flow in a heating
or cooling circuit based on volumetric
flow and the temperatures at the input
and output (temperature difference) of a
heat exchanger.
Suitable for all fluids.
The Steam Calculator EngyCal® RS33
measures the mass and energy flow of
saturated and superheated steam based
on volumetric flow and the temperatures
and/or pressure.
The combination of Field Data Manager Software MS20 and
EngyCal® delivers data transparency and a solid basis for decision
making based on
• data and event visualization for Target-Performance-Comparison,
• tamper-proof documentation to validate invoices and
• identification of main consuming actors.
3
Endress+Hauser Wetzer
Endress+Hauser Wetzer GmbH & Co. KG
Obere Wank 1
87484 Nesselwang
Germany
Tel. +49 (0)8361 308 0
Fax +49 (0)8361 308 110
http://www.wetzer.endress.com
[email protected]
CP006R/09/en/07.10
71119867
INDD CS2
Flow
+
• RSG40
• RMS621/RMC621
• EngyCal® RH33
• EngyCal® RS33
• Prowirl 72
• DP Flow: DO / DP
• Prosonic 92F
• Prowirl 72
• DP Flow: DO / DP
• Prosonic 92F
• Promag
• Promag
• DP Flow: DO / DP
• Prowirl 72
• Prosonic 92F
Water
• DP Flow: DO / DP
• Prowirl 72/73
Steam
• TMT111/112 (DIN rail), TMT181 (head)
• Special products
Water de-mineralized
• TAF12S / TC6x-Family
• TR10 / TR11 / TR15
TC up to 1700 °C / 3092 °F
• Cerabar S (up to +/-0.075 % (0.05 % platinum) accuracy)
à 3rd party products
à System integration
à Automation solutions
à Application engineering
à Know how transfer / training
à Customer device training
à Pre-configuration of devices
à Commissioning & software installations
à Re-calibration and sensor verification
(also for custody transfer applications)
à Customer specific sensor calibration
à W@M - Life Cycle Management
Services / Life Cycle Management:
• Cerabar M (up to +/-0.15 % (0.075 % platinum) accuracy)
• Cerabar T (up to +/-0.5 % accuracy)
Multiple
measurement
points
Manager Software
• Field Data
Single
measurement
point
RTD up to 600 °C / 1112 °F
+
Energy
Manager
+
Software
• eSight
Fluids / Mixtures
+
Pressure
(for steam
applications)
Temperature
à Passive barrier
RB223 (if sensor is
installed in Ex zone)
à Power supply RN221N
- separated power supply
for each sensor & Ex separation
à Surge arrester HAW569
(field instruments) or
HAW562 (DIN rail)
Supply and protection for the sensors:
Integrated Offering