Condensed Launch EngyCal® RH33 BTU Meter and EngyCal® RS33 Steam Calculator Disclose waste of energy and reduce costs EngyCal® RH33 and RS33 enable • Transparency on energy consuming plants and processes • Sustainability within the energy management • Process stability through continuous monitoring Reduce energy costs by up to 8% with monitoring and analyzing energy consumption based on reliable and accurate calculation and measurement instruments. Proven reduction potential without additional investment just by an increased awareness and change in behavior. Open and web based information Access to information worldwide via the web browser free of charge! Reduce costs for system integration and information transfer over the complete life time! The following information is available: • measured values (temperature, pressure, mass flow) • calculated values (energy, enthalpy, Delta T, …) • alarm and limits • device and value status In addition the electronic name plate (showing serial number, tag, etc.) can be obtained via the web server as well. Information supply via Field Data Manager software Consolidates the measured and calculated data, visualizes the consumption, generates reports automatically and delivers a tamper-proof documentation. Your benefits: • Target-performance comparison and benchmarking • Identify and monitor energy intensive process steps • Create correlations between energy consuming plants (heat exchanger for process heating) and energy generators (like boilers) • Validate invoices - monitor energy usage on consumer side for comparison purposes • Automatically create invoices in combination with an ERP system Highly accurate measurement technology – calculation according to IAPWS Endress+Hauser offers a complete portfolio of devices and tools calculating energy of water and steam according to the international standard IAPWS-97. IAPWS delivers an internationally accepted formulation for properties • light and heavy steam, • water and • selected aqueous mixtures in • thermal power cycles and • other industrial applications. 2 www.products.endress.com/energymanager The BTU Meter EngyCal® RH33 measures the energy flow in a heating or cooling circuit based on volumetric flow and the temperatures at the input and output (temperature difference) of a heat exchanger. Suitable for all fluids. The Steam Calculator EngyCal® RS33 measures the mass and energy flow of saturated and superheated steam based on volumetric flow and the temperatures and/or pressure. The combination of Field Data Manager Software MS20 and EngyCal® delivers data transparency and a solid basis for decision making based on • data and event visualization for Target-Performance-Comparison, • tamper-proof documentation to validate invoices and • identification of main consuming actors. 3 Endress+Hauser Wetzer Endress+Hauser Wetzer GmbH & Co. KG Obere Wank 1 87484 Nesselwang Germany Tel. +49 (0)8361 308 0 Fax +49 (0)8361 308 110 http://www.wetzer.endress.com [email protected] CP006R/09/en/07.10 71119867 INDD CS2 Flow + • RSG40 • RMS621/RMC621 • EngyCal® RH33 • EngyCal® RS33 • Prowirl 72 • DP Flow: DO / DP • Prosonic 92F • Prowirl 72 • DP Flow: DO / DP • Prosonic 92F • Promag • Promag • DP Flow: DO / DP • Prowirl 72 • Prosonic 92F Water • DP Flow: DO / DP • Prowirl 72/73 Steam • TMT111/112 (DIN rail), TMT181 (head) • Special products Water de-mineralized • TAF12S / TC6x-Family • TR10 / TR11 / TR15 TC up to 1700 °C / 3092 °F • Cerabar S (up to +/-0.075 % (0.05 % platinum) accuracy) à 3rd party products à System integration à Automation solutions à Application engineering à Know how transfer / training à Customer device training à Pre-configuration of devices à Commissioning & software installations à Re-calibration and sensor verification (also for custody transfer applications) à Customer specific sensor calibration à W@M - Life Cycle Management Services / Life Cycle Management: • Cerabar M (up to +/-0.15 % (0.075 % platinum) accuracy) • Cerabar T (up to +/-0.5 % accuracy) Multiple measurement points Manager Software • Field Data Single measurement point RTD up to 600 °C / 1112 °F + Energy Manager + Software • eSight Fluids / Mixtures + Pressure (for steam applications) Temperature à Passive barrier RB223 (if sensor is installed in Ex zone) à Power supply RN221N - separated power supply for each sensor & Ex separation à Surge arrester HAW569 (field instruments) or HAW562 (DIN rail) Supply and protection for the sensors: Integrated Offering
© Copyright 2026 Paperzz