- Hartmann Controls Corp.

Installation Example
D
A
QR Code for POE-ODM
Controller
A POE-ODM
C
Outputs
H
POE-ODM
B
C
D
Quick Start Guide
I
G
R1
9
8
7
HARTMANN
6
5
4
0
NN
MA
RT
HA
R2
Auto Door Opener
Extra Loud Buzzer*
Inputs
G Handicap Open
H Door Contact
I Emergency Alarm
3
2
1
Electric Strike
J
B
J
R1
R2
Doorbell
Inside Reader
Outside Reader
*Optional Internal Extra Loud Buzzer
Part Number
Motion Sensor
Color
POE-ODM-MB
POE-ODM-XB
Yes
No
Black
Black
POE-ODM-MW
POE-ODM-XW
Yes
No
White
White
Networking Examples
: POE Powered
: Normal
1 Controller - POE Injector - PC (Direct)
Package Contents
In Ou
t
POE-ODM x 1
2
2P Connector x 4
3P Connector x 2
Controller - POE Injector - Router - PC
6P Connector x 2
In Ou
t
LAN
Supervisor Input
Resistor(1K ) x 8
Cover screw x 2
INTERNET
Wall screw x 4
* LAN or Internet
UL 294 / S319 Compliance Notices
3
Controllers - POE Router - PC
This product complies with the following UL294 Access Control Performance Levels when installed as part of the Listed
Protector.Net system :
Endurance Level IV (100,000c)
Line Security Level I
Wiring methods shall be in accordance with the National Electrical Code (ANSI/NFPA70), CSA C22.1, Canadian Electrical Code,
Part I, Safety Standard for Electrical Installations, Part I, local codes, and the authorities having jurisdiction. All interconnecting
devices must be UL Listed, low-voltage Class 2 power limited. The minimum permissible wire size to be used shall not be less than
26 AWG (0.24 mm2).
Products have been evaluated for “Indoor Use” only, and to be installed within the “protected” or “restricted” area. This product is
not intended for outside wiring as covered by Article 800 in the National Electrical Code, NFPA 70. Products are not intended to be
installed or mounted in air-handling spaces. Products are intended to be installed by manufacturer trained service installers only.
LAN
INTERNET
All recommended connected peripherals such as power supplies, UPS/battery backups, PoE switches, electrified strikes, readers
require to be UL Listed.
Please refer to the Protector.Net UL Reference document for more comprehensive information available via the installation USB
drive or downloadable from our website. Hard copy of the Protector.Net UL Reference Manual document is available – call for
pricing.
HARTMANN CONTROLS Corp
Part Number : 8001-05-0098-01-02 Rev 09.16
* LAN or Internet
www.hartmann-controls.com
Networking Examples
: POE Powered
(Continued)
Readers & Usage Example
Wiring Specification
: Normal
Ground
Power (12V DC)
LED
Buzzer
Data 1
Data 0
4 Controllers - POE Switch - Router - PC
LAN
Black and shield wires
1
Red wire
2
Brown wire
3
Blue wire
4
White wire
5
Green wire
6
1
2
3
4
5
6
7
8
9
0
HARTMANN
LAN
INTERNET
* LAN or Internet
5
1
1
2
2
3
3
4
4
5
5
6
6
Controllers - POE Switch (at doors) - Router - PC
* At door
LAN
HARTMANN
* Can be wireless
Note : Reader Test
LAN
INTERNET
1
Get in Tools Menu Mode
by pressing
keys in order.
2 Select Reader Test menu.
(
3 Scan a card or press numbers and #
( keypad reader only ). LCD shows
the data infomation.
Reader : 1, Bit:40
33, 13532
Input Test
Reader Test
* LAN or Internet
Outputs & Usage Example
Inputs & Usage Example
Specification
P1 (Relay1, Lock power)
P8 (12V DC out)
P6 (Relay2)
P7 (Relay3)
Enter keys )
Specification
P2 1-2 Pin (Input1)
P2 2-3 Pin (Input2)
P3 1-2 Pin (Input3)
P3 2-3 Pin (Input4)
Lock power relay, 1 GND, 2 12V DC 500mA
12V DC output, 1 GND, 2 12V DC 200mA
24V DC 500mA limit
24V DC 500mA limit
* All the relay outputs are configurable.
For example, Relay2 can be configured to a door strike.
2 Common (GND)
1 Input
2 Common (GND)
3 Input
1 Input
2 Common (GND)
2 Common (GND)
3 Input
* All the inputs are configurable.
For example, Input1 can be configured to a doorbell.
PUSH
TO
EXIT
Request to Exit
1
Door Strike
2
1
2
1
1
2
2
3
3
Door Contact
Optional Internal Extra Loud Buzzer
1
2
1
External Motion Sensor
2
Automatic Door Opener
Emergency Alarm
Note : Output Test
1
Get in Tools Menu Mode
by pressing
keys in order.
Note : Input Test
2 Select Output Test menu.
(
Enter keys )
Output Test
Input Test
HARTMANN CONTROLS Corp
3 Toggle selected relay by pressing Enter.
( Select change :
0 = Off, 1 = On )
keys,
R1 R2 R3
1 0 0
Part Number : 8001-05-0098-01-02 Rev 09.16
1
Get in Tools Menu Mode
by pressing
keys in order.
2 Select Input Test menu.
(
Enter keys )
Input Test
Reader Test
3 LCD displays current input states.
( 0 = Off, 1 = On, 2 = Short,
3 = Disconnected )
I1 I2 I3 I4
1 0 2 3
www.hartmann-controls.com
Dimensions
Input Types
Specification
260 mm (10.236”)
Digital*
Supervised*
Off(DO), On(DC)
Off(SO), On(SC), Short(DC), No connection(DO)
* Software selectable
59.3 mm
(2.335”)
1 Digital Input States
Input1
Common
Off
1
2
3
Input1
Common
On
1
2
88 mm
(3.465”)
3
2
Supervised Input States
Input1
Common
Off
1
*
*
2
3
Input1
Common
38 mm
(1.496”)
On
1
2
3
Input1
Common
129.3 mm (5.090”)
Short
1
4.5 mm Dia.
25 mm
2
3
Input1
Common
50 mm
(1.968”)
No connection
1
58 mm
(2.283”)
7 mm
2
3
* 1K
Resistor
240 mm (9.449”)
Board I/O and Connections
1
2
1
1
2
2
3
3
1
4
4
2
5
5
6
6
1
2
1
2
1
1
2
2
3
3
LEDs
Connectors
D1
System heart beat
P1
Relay1, DC 12V wet contact
D2
Server log on/off state
Key pressed
P2
Input1, Common, Input2
P3
Input3, Common, Input4
P4
Reader1
P5
Reader2
P6
Relay2
P7
Relay3
P8
DC 12V out
P11
Sensor module
P21
Expansion
P22
Expansion
J1
Ethernet
D3
On: Server log off
Blink: Server log in
D4
Green: Motion detected
Red: Door Opened
D5
Relay2 on
D6
Relay3 on
D7
Relay1 on
D8
Reader1 data flow
D9
Reader2 data flow
D17
POE power
D24
CPU power
LINK
Ethernet linked
ACT
Ethernet Activity
HARTMANN CONTROLS Corp
S1
D4
Setup Menu View Mode
D3
Get in
Press and hold Esc
(beeps after 2 sec)
Get out
Move cursor
Select menu
Exit menu
Esc
Up(Right),Down(Left)
Enter
Esc
Keys
SW1
SW2
SW3
SW4
Left( ), down( )
Right( ), up( )
Enter, get in
Get in
Press and hold Enter
(beeps after 2 sec)
Enter password**
Toggle cursor
Enter
White blink: move
Black blink: edit
Esc, exit
Etc
LS1
S1
BZ1
P20
VR1
Setup Menu Edit Mode*
Tamper sensor
Get out
Esc
Motion sensor
Move cursor
Up(Right),Down(Left)
Select menu
Enter
Exit menu
Esc
Embedded buzzer
LCD display
LCD contrast
Part Number : 8001-05-0098-01-02 Rev 09.16
Note
* For the first time installation, get in this
mode and do following tests.
Output Test : Toggle relays with Enter
Input Test : Shows input states
Reader Test : Shows scaned card info
** Factory default password is 0000.
Toll Free: 1-877-411-0101
www.hartmann-controls.com
Cable Requirements
Motion Sensor
Specification
Sensor Type
Detection Range
Detection Angle
Detection Zone
Name
PIR
5m
H: 94 , V: 82
64 zones
Maximum
Distance
Cable Type
Code
POE Cable**
100 m (328’)
twisted pair, 4 pairs
Cat5 100BASE-T or better
Reader Cable
152 m (500’)
6 conductor stranded not twisted,
24 AWG or thicker,
100% overall shielded
Belden 9537 or equivalent
Door Strike Cable
152 m (500’)
2 conductor stranded 18 AWG
Belden 9740 or equivalent*
Output Cable
152 m (500’)
2 conductor stranded 22 AWG
Belden 8740 or equivalent*
Input Cable
152 m (500’)
2 conductor stranded 22 AWG,
shielded
Belden 8723 or equivalent*
* Unless otherwise specified by manufacturer.
** Recommended the following T568B wiring for both ends.
94
T568B (TIA/EIA568B) Wiring
2.2 m
(86.61”)
1 2 3 4 5 6 7 8
1
2.55 m
(100.39”)
5.8 m
(228.35”)
White/Orange
2
Orange
3
White/Green
4
Blue
5
White/Blue
6
Green
7
White/Brown
8
Brown
Single Door Typical
(with motion, single reader, door contact, auto door opener)
1
2
1
1
2
2
3
3
1
4
4
2
5
5
6
6
1
2
1
2
1
1
2
2
3
3
C
G
Outputs
F
A
C
R1
2
1
5
4
8
7
3
6
9
Wet Lock Power (12V DC 500mA)
Auto Door Opener (dry)
Inputs
F Door Contact (dry)
G Handicap Button (dry)
R1 Outside Reader
0
NN
MA
RT
HA
A
HARTMANN CONTROLS Corp
Part Number : 8001-05-00 98-01-02 Rev 09.16